ATM 322 Basic Pneumatics H.W.6 Modules 5 7

Similar documents
Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

Basic Pneumatics. Module 9: Time delay valve. Academic Services PREPARED BY. April 2012

Introduction to Pneumatics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Basic Pneumatics. Module 2: Direct Control of single acting cylinder PREPARED BY. IAT Curriculum Unit. January 2011

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Circuit building blocks

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Flow and check valves Logic valves series 551. Brochure

Industrial Pneumatics

The University of Jordan. School of Engineering. Mechatronics Engineering Department

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Time-Delay Electropneumatic Applications

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary.

[You may download this article at: ]

Hand lever valves VHER

TECHNOLOGICAL STUDIES. Intermediate 2. Mechanical Systems. Section 1. Outcome 1 Pneumatic Systems

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

Application of EN ISO in electro-pneumatic control systems

Learning System for Automation and Communications. Pneumatics. Workbook Basic Level

Hydraulics. Hydraulic Pressure Control

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

Model 130M Pneumatic Controller

Valves, manually operated

Pneumatic Grippers Swivel Modules

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Valves, manually operated

Oil connector 3/8NPT. usable oil Air inlet pressure max. operating Air consumtion. oil capacity capacity min. max.

EXH. Specifications. Descriptions. Min. working pressure MPa

Safety Beyond the Electrics

TRAINING SCHEDULE FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Panel-mounted valves Series T, Ø 22.5 mm

APPLICATION NOTE E SQUEEZE DELAY AND RETRACTION OPERATION

Pneumatics. ZF Marine Pneumatics

Lesson 6: Flow Control Valves

TECHNICAL INFORMATION

Introduction. Part one: Identify the Hydraulic Trainer Components

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

UNIVERSITY OF MAURITIUS FACULTY OF ENGINEERING

Pressure on Demand. Air Pressure Amplifiers

Priority (Swing) Motors Data and Specifications

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

VBX-160 Gripper Sensors

AUTOMATED INDUSTRIAL MACHINE, INC

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE

Valve Communication Solutions Axiom

Pressure regulators Manually operated Fine setting valves. Brochure

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

Application Note. Safety Sub-functions SSC Category 1, up to PL c PUS Category 1, up to PL c. Application Note SSC, PUS, Category 1, up to PL c STOP

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

OWNER S TECHNICAL MANUAL

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Gripping rotary modules

Pressure Automated Calibration Equipment

COSMO INSTRUMENTS CO., LTD.

AIR/OIL BOOSTER APPLICATIONS TECHNICAL DATA

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SWG. Application example. Pneumatic 2-Finger Angular Gripper Angular Gripper for Small Components. Sizes Gripping moment 0.01 Nm.. 2.

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION

Technical Data Sheet TI-F50 Locking Units series KFH

Phuel Modular Control Units

SERVICE MANUAL No. I-0043

Air preparation units

Study Unit. Pneumatics, Part 2. Thomas Gregory

Proportional pressure regulators VPPE

Float Operated Level Controllers

WORKHOLDING APPLICATION BOOKLET

Unit 24: Applications of Pneumatics and Hydraulics

Power Clamp Cylinder

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Pneumatics for Newbies Designing a Pneumatic Solution

SSL. Smart Valve Positioner.

The Ins and Outs of I/P Transducers

Max operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min

Ch 12 Homework. Name: Homework problems are from the Serway & Vuille 10 th edition. Follow the instructions and show your work clearly. 1.

CONTROL VALVE TESTING

FLOAT OPERATED LEVEL CONTROLLER

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Learning System for Automation and Communications. Hydraulics. Workbook Basic Level

RC 195 Receiver-Controller

Evaporative Emissions (EVAP) system, checking

FLOAT OPERATED LEVEL CONTROLLER

Pilot Operated Check Valves Catalog Quick Reference

(Refer Slide Time: 0:26)

Control Units for Oil+Air Lubrication

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Section 4: Sequence valve adjustments

Transcription:

ATM 322 Basic Pneumatics H.W.6 Modules 5 7 Name: Answer Key Mark: Question I: Write (T) for True and (F) for false sentences. A) For the time dependant process control; Step enabling conditions are generated via timers at constant speed. T B) For the process dependant process control; Step enabling conditions depend purely on the stroke dependant signals of the controlled systems. T C) The time delay valve returns to normal position via spring. T D) In the time delay valve; the delay time is generally 0 400 s. F E) The type of the time delay valve whether normally opened or closed depends on the one way flow control valve. F F) For the time delay valve; The time required for pressure to build up in the air reservoir is equal to the control time of the valve. T G) For the shuttle valve; if a compressed air signal is applied to input X or input Y, this will produce a signal at output Z. T H) For the Two Dual pressure valve; if one input signal is applied, there will be no output signal. T I) Sequence control is divided into two subgroups: Time dependant and speed dependant. F Question II: Draw the equivalent circuit to the AND function controlling a double acting cylinder.

Question III: Answer the questions shown below. [marks] A) Name and define the two types of sequence control. i) Time dependant sequence control: A sequence control where the switching conditions are dependent only on time. ii) Process dependant sequence control: A sequence control system where the switching conditions are dependent only on signals from the system being controlled. B) When do we use displacement step diagrams? We use displacement step diagrams when we want to represent the desired motion of all actuators in the case of multiple cylinder circuits. C) In case of multiple actuators, the representation of the desired motion of all actuators is described using displacement step diagram. D) Name the valves that are used to eliminate signal overlap. roller lever valves with idle return or toggle lever valves, time delay valves, reversing valves or sequencers. E) Draw the displacement step diagram for both actuators 1A and 2A; knowing that cylinder 1A starts first.

F) Draw the displacement step diagram for each of the following sequences. i) C+B+A+C-B-A- iii) C+C-B+B-A+A- G) Find the sequence of operation for the given displacement step diagram.

A+B+B-C+A-C- H) State the function of the time delay valve. Time delay valve is used to delay the output signal. I) The time delay valve consist of 3 parts, name them. Air reservoir, 3/2 DCV N/C or N/O, one way flow control valve. J) How can the delay time be extended? By using additional reservoirs. K) Explain how the time delay valve works. Label the ports (1,2,3,12) The compressed air is supplied to the valve at connection 1. The control air flows into the valve at 12 through a one way flow control valve and depending on the setting of the throttling screw, a greater or lesser amount of air flows per unit of time into the air reservoir, when the necessary control pressure has built up in the air reservoir, the pilot control of the 3/2 way valve is moved downwards. This blocks the passage from 2 to 3. The valve disc is lifted from its seat and thus air can flow from1 to 2 Question IV: Draw the ISO symbols for each of the following. Time Delay Valve N/C Time Delay Valve N/O Shuttle Valve Two Dual Pressure Valve

Pressure Regulating Valve Pressure Sequence Valve Question V: Draw the pneumatic circuit diagram for each of the following. A) 1-Double acting cylinder will extend when 3/2 way valve is actuated (Keep pressing) 2-The double acting cylinder will retract when push button is released.

B) 1- The cylinder has to be operated by operating the four valves at the same time. 2- Releasing any valve results in attracting the cylinder back to its initial position C) A double acting cylinder is used to press together glued components. Upon operation of a push button valve, the clamping cylinder (1A) extends. Once the fully advanced position is reached, the cylinder is to retract automatically to the initial position. The cylinder speed is to be adjustable. A new start cycle is only possible after the cylinder has fully retracted.

Question VI: Choose the correct answer. 1. The main purpose of the is to accept the pneumatic signals from two different locations. A. Shuttle Valve B. 3/2 Directional control valve N/C C. Quick Exhaust Valve D. One way Flow Control Valve E. 5/2 double pilot DCV 2. Which valve works as an AND gate? A. Two Dual Pressure Valve B. 3/2 Directional control valve N/C C. Quick Exhaust Valve D. One way Flow Control Valve E. 5/2 double pilot DCV

3. In the shuttle valve; if signals are present at both inputs, the signal reaches the output. A. With the higher pressure B. With the lower pressure C. Arriving last D. Arriving first None of the above