Section 2 Proportional Quick Exhaust

Similar documents
GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

QBS Electronic Pressure Regulator

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS

QBS Electronic Control Valve

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Model 4000 Pressure Controller

Design Features. General Description

INSTALLATION & MAINTENANCE INSTRUCTIONS QBX ETHERNET MODEL

Direct solenoid and solenoid pilot operated valves

86BSD Backside Digital Output

EPP4 Pressure Regulator Basic G 1/4"

Electropneumatic Transducer (I/P) Installation, Operation and

PRODUCT CATALOG ELECTRO-PNEUMATIC PRESSURE REGULATORS & FLOW CONTROLLERS PRESSURE FLOW FORCE TENSION POSITION TORQUE VACUUM

1200 Series Pressure Regulators

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

How to Order. Rc NPT 1/8 1/4 3/8 1/2

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

shutoff valves 900 Series psig Manual Shutoff Valves

RCD - Ultra-Rugged Differential Pressure Flowmeter

INSTRUMENT MANUAL VP50 PROPORTIONAL CONTROL VALVE

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Proportional pressure regulators VPPE

ERNG-X TESCOM Product Manual

ER3000 Explosion Proof Manual

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Direct solenoid and solenoid pilot operated valves

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

GAS FUEL VALVE FORM AGV5 OM 8-03

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

TR Electronic Pressure Regulator. User s Manual

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

PRO-50 Instrument Supply Regulator

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Pressure Independent Control Series

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Dynisco SPX Industrial (2280/2281) Series

VACUUM REGULATORS CONTENTS

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20.

Pilot Check Valve: Metal Body Type

Miniature Electronic Pressure Controllers. Precision Fluidics

Electro-Pneumatic Converter YT-940 SERIES

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

THE INSIDE STORY OF THE F-SERIES:

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Directional Control Valves Technical Information Model 1500

Model 106 DPI "Micro-switch" Installation and Operating Instructions

C-Flow Coriolis Mass Flow Meters

BD Series Back Pressure Regulators and Valves For Gas, liquid and mixed phase service

CASH VALVE TYPE KP BACK PRESSURE VALVES

2/ Port G1/4

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Air preparation units

SUPER PRECISION AIR RELAYS

Variable Area Flow Meters

RG2 Gripper Datasheet Version 1.6

The Ultimate. in Precision Pressure Control. Precision Back Pressure Regulators. GS Series Gas and Mixed Phase Service

SG1 Series Regulators - Pressure Reducing

Liquid Level Controllers

Booster Regulator/Air Tank

Operation Manual Air Saver Unit ASV5000 Series

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Model 10. Low-Medium Pressure Reducing Regulator

QBX QBT QBS ELECTRO-PNEUMATIC PRESSURE REGULATORS. On-Board Ethernet Option. Accurate & Repeatable. High Pressure Control. Up to 12 bar & 34 Lit/Min

Digital electro-pneumatic regulators Series ER100

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SG3 Series Regulators - Pressure Reducing

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Precision and Instrument Regulators 1/4" port size

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Pressure on Demand. Air Pressure Amplifiers

FAS-W. Features. Applications. Automatic condensation hygrometer

REASONS FOR THE DEVELOPMENT

Hand lever valves VHER

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PVQ 13 A2 R SE 1 S 20 C-11 D

SPCH/ Blowing block

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.


Additel 780 Series Pressure Controller

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

QBX QBS QBT ELECTRO-PNEUMATIC PRESSURE REGULATORS. On-Board Ethernet Option. Accurate & Repeatable. High Pressure Control. Up to 12 bar & 34 Lit/Min

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

SOLENOID VALVES AND PNEUMATIC VALVES

For Multi-Parameter Meters see mvx

Additel 780 Series Pressure Controller

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

Transcription:

V A L V E S Section 2 Proportional Quick Exhaust OPERATION OF THE PQE 1. The pilot operated regulator and the PPC5C are both fed from a common inlet. 2. The out port of the PPC5C sends pressure to the pilot port of the pilot operated regulator and to the 12 end of the 400 Series Quick Exhaust Valve. The secondary pressure of the pilot operated regulator is sent to the output port of the block and it is also sent to the 14 end and inlet of the 400 Series Quick Exhaust Valve. 3. The outlet pressure of the PPC5C along with the memory spring in the 400 Series valve will keep the valve in a closed state as the unit increases pressure. 4. To reduce pressure, drop the PPC5C s signal. This will lower the pressure on the 12 end of the 400 Series valve. The 14 end of the 400 Series valve now has higher pressure causing a snap-action shifting of the 400 Series valve which will quickly exhaust the downstream pressure to the new selected pressure. Note: Below 20 psi, the P.Q.E. has reduced exhausting capabilities due to the memory spring in the 400 Series Quick Exhaust Valve and modifications to the pilot operated regulator. OUT P2 REGULATED PRESSURE PILOT OPERATED REGULATOR INLET P1 LINE PRESSURE OUT PPC5C IN 14 12 PPC5C EXHAUST PATH 400 SERIES QUICK EXHAUST VALVE QUICK EXHAUST 65 Consult Precautions page 94 before use, installation or service of MAC Valves.

Proportional quick exhaust Port size Flow (Max) (Cv/Nl/min) Individual mounting Series 1/2-3/4 6.3/6300 analog OPERATIONAL BENEFITS 1. Accurate pressure control. 2. Fast response. 3. High flow. 4. Quick exhaust function. 5. Unaffected by change in line pressure. 6. Long life. 7. Designed to meet Nema 4 specifications. 8. Analog control. 9. Analog or TTL feedback. 10. Closed loop system. 6500 92 HOW TO ORDER PROPORTIONAL QUICK EXHAUST PQE 65 A - XX X X ( - 9) Indicates unit is to be assembled with PPC, which is ordered separately Regulator size (series) 65 6500 Series Sense AA Standard Gage port on regulator 1 No gage - gage port plugged 2 Include gage, filled *(List gage separately) * Gage part #24142-160 Port size & thread type C 1/2 NPTF (6500 Series) D 3/4 NPTF (6500 Series) G 1/2 BSPPL (6500 Series) H 3/4 BSPPL (6500 Series) L 1/2 BSPTR (6500 Series) M 3/4 BSPTR (6500 Series) EXAMPLE : PQE65A - AA1C - 9 PPC5C - AGB- AGEA - BBB - C0-9 NOTE : PPC5C must be ordered separately. Reference How to order for the analog PPC5C. PPC5C SERIES BASIC MODEL PPC5C X X X - X X X X - (X X X - X X) SIGNAL & CONNECTOR OPTIONS (SEE BELOW) Type Porting Feedback options Pressure range PSI/BAR Pressure reference Overall accuracy Flow Cv/Nl/min Fill Exh. A Analog G BOTTOM PORTS O-ring Mount B Single Xducer/ Ext. Sense (Pressure) A 100/6.7 B 60/4 C 30/2 E 50/3.3 F 80/5.3 J 75/5 K 117/7.8 M 150/10 P 90/6 G Gage Pressure E ± 2.5 % F.S. A 0.07/70 0.07/70 B 0.09/90 0.09/90 C 0.07/70 0.09/90 SIGNAL & CONNECTOR OPTIONS X X X - X X Command signal Analog monitor signal Logic monitor signal (10mA, MAX) Electrical connector Cable length B 0-10V Differential C 4-20mA 3-Wire D 4-20mA 4-Wire B 0-10V B TTL (Low = Pressure Achieved) C TTL (High = Pressure Achieved) D 24V (Low = Pressure Achieved) E 24V (High = Pressure Achieved) A 3 Pin Mini B 5 Pin Mini C 6 Pin Mini D 3 Pin Micro E 5 Pin Micro F 6 Pin Micro G 3 Wire Grommet H 4 Wire Grommet I 5 Wire Grommet J 6 Wire Grommet 0 No Cable B 3 Ft/0.9m D 6 Ft/1.8m E 12 Ft/3.6m IMPORTANT! READ NOTES BEFORE ORDERING For options 0 (no cable), choose electrical connector options A through F only. 69 Consult Precautions page 94 before use, installation or service of MAC Valves.

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS PPC TYPE Analog, single transducer external sense, bottom O-ring mount ELECTRICAL DATA PHYSICAL DATA Connector : Enclosure : Aluminum, sealed Mounting : Any plane Ambient temperature range : 0 to 50 C (32 F to 120 F) PNEUMATIC DATA Inlet pressure : Fluids : Lubrication : Filtration : *Output pressure : Overall accuracy : All ports : Flows : Output flow : Exhaust flow : **Output volume requirements : 120 PSI max Air or inert gases Not required. However, if used, a medium aniline point oil is recommended 40 micron 20 to 100 PSI 2.5% full scale 1/2, 3/4, NPTF, BSPPL, BSPTR 1/2 ports: Cv 5.3 3/4 ports: Cv 6.3 1/2 ports: Cv 1.5 3/4 ports: Cv 1.5 Port size Output volume at Minimum length end of output pipe of output pipe 1/2 100 Cu. in. and larger 78 50 to 99 Cu. in. 100 3/4 100 Cu. in. and larger 60 50 to 99 Cu. in. 90 * The quick exhaust portion of the PQE was not designed to be used at pressures below 20 PSIG. The PQE will exhaust below 20 PSIG but at a very reduced rate. Also, the minimum pressure change (from higher to lower) that will allow the quick exhaust to function is 3 PSIG. ** This is the minimum output volume and output piping required to keep the unit stable. Configurations below these minimums should be tested on a case by case basis. DIMENSIONS 87.90 6.0 6.0 57.85 154.2 3/4" or 1/2" PORTS TYP. (3) 61.5 23.0 OUT IN 101.60 26.5 27.0 32.0 111.95 18.85 212.0 5.20 DIA. THRU (2) MTG. HOLES 63.5 70 Consult Precautions page 94 before use, installation or service of MAC Valves.

Proportional quick exhaust Port size Flow (Max) (Cv/Nl/min) Individual mounting Series 1/2-3/4 6.3/6300 digital OPERATIONAL BENEFITS 1. Accurate pressure control. 2. Fast response. 3. High flow. 4. Quick exhaust function. 5. Unaffected by change in line pressure. 6. Long life. 7. Designed to meet Nema 4 specifications. 8. Digital control. 9. Analog or TTL feedback. 10. Closed loop system. 6500 92 HOW TO ORDER PROPORTIONAL QUICK EXHAUST PQE 65 A - XX X X ( - 9) Indicates unit is to be assembled with PPC, which is ordered separately Regulator size (series) Sense Gage port on regulator Port size & thread type EXAMPLE : PQE65A - AA1C - 9 PPC5C DGB- AGEA - AAA - 9 65 6500 Series AA Standard 1 No gage - gage port plugged 2 Include gage, filled *(List gage separately) * Gage part #24142-160 C 1/2 NPTF (6500 Series) D 3/4 NPTF (6500 Series) G 1/2 BSPPL (6500 Series) H 3/4 BSPPL (6500 Series) K 1/2 BSPTR (6500 Series) L 3/4 BSPTR (6500 Series) 6500 Series style regulator, standard sense, no gage, 1/2 NPTF ports. Digital PPC, bottom o-ring mount, external sense, 100 psi range, gage reference, 2.5% accuracy, with.07 flow (fill and exhaust), 4 bit sinking/positive command signal, no analog or logic signal, 6-pin mini connector, no cable. NOTE : PPC5C must be ordered separately. Reference How to order for the digital PPC5C. PPC5C SERIES BASIC MODEL PPC5C X X X - X X X X - (X X X - X X) SIGNAL & CONNECTOR OPTIONS (SEE BELOW) Type Porting Feedback options Pressure range PSI/BAR Pressure reference Overall accuracy Flow Cv/Nl/min Fill Exh. D Digital G BOTTOM PORTS O-ring Mount B Single Xducer/ Ext. Sense (Pressure) A 100/6.7 B 60/4 C 30/2 E 50/3.3 F 80/5.3 J 75/5 K 117/7.8 M 150/10 P 90/6 G Gage Pressure E ± 2.5 % F.S. A 0.07/70 0.07/70 B 0.09/90 0.09/90 C 0.07/70 0.09/90 SIGNAL & CONNECTOR OPTIONS X X X - X X Command signal Analog monitor signal Logic monitor signal (10mA, MAX) Electrical connector Cable length A 4-Bit Sinking/pos. B 4-Bit Sourcing/pos. C 8-Bit Sinking/pos. D 8-Bit Sourcing/pos. G 4-Bit Sinking/neg. H 4-Bit Sourcing/neg. J 8-Bit Sinking/neg. K 8-Bit Sourcing/neg. B 0-10V B TTL (Low = Pressure Achieved) C TTL (High = Pressure Achieved) D 24V (Low = Pressure Achieved) E 24V (High = Pressure Achieved) A 6 Pin Mini B 7 Pin Mini C 8 Pin Mini G 14 Wire 0 No Cable B 3 Ft/0.9m D 6 Ft/1.8m E 12 Ft/3.6m IMPORTANT! READ NOTES BEFORE ORDERING All connector options are available with the 4-Bit command signal. Options A, B and C can be supplied with or without a cable. Option G requires a cable. Select length from table. The 4-Bit command signal without the analog monitor signal (AMS) or logic monitor signal (LMS) requires a 6 Pin connector. For the AMS or LMS options, add one pin for each. The 8-Bit command signal can only use option G. Select cable length from table. 71 Consult Precautions page 94 before use, installation or service of MAC Valves.

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS PPC TYPE Digital, single transducer external sense, bottom O-ring mount ELECTRICAL DATA PHYSICAL DATA Connector : Enclosure : Aluminum, sealed Mounting : Any plane Ambient temperature range : 0 to 50 C (32 F to 120 F) PNEUMATIC DATA Inlet pressure : Fluids : Lubrication : Filtration : *Output pressure : Overall accuracy : All ports : Flows : Output flow : Exhaust flow : **Output volume requirements : 120 PSI max Air or inert gases Not required. However, if used, a medium aniline point oil is recommended 40 micron 20 to 100 PSI 2.5% full scale 1/2, 3/4, NPTF, BSPPL, BSPTR 1/2 ports: Cv 5.3 3/4 ports: Cv 6.3 1/2 ports: Cv 1.5 3/4 ports: Cv 1.5 Port size Output volume at Minimum length end of output pipe of output pipe 1/2 100 Cu. in. and larger 78 50 to 99 Cu. in. 100 3/4 100 Cu. in. and larger 60 50 to 99 Cu. in. 90 * The quick exhaust portion of the PQE was not designed to be used at pressures below 20 PSIG. The PQE will exhaust below 20 PSIG but at a very reduced rate. Also, the minimum pressure change (from higher to lower) that will allow the quick exhaust to function is 3 PSIG. ** This is the minimum output volume and output piping required to keep the unit stable. Configurations below these minimums should be tested on a case by case basis. DIMENSIONS 87.90 6.0 6.0 57.85 154.2 3/4" or 1/2" PORTS TYP. (3) 61.5 23.0 OUT IN 101.60 26.5 27.0 32.0 111.95 18.85 212.0 5.20 DIA. THRU (2) MTG. HOLES 63.5 72 Consult Precautions page 94 before use, installation or service of MAC Valves.