IP65 Air Differential Pressure Switch

Similar documents
Air Differentail Pressure Switch

SPD310/SPD360 Air Differential

Pressure Transmitters 36 F-27839

Electro Controls. Pressure WattsIndustries.co.uk

Installation and Operation Manual

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

Ventam 85 Installation & Commissioning Instructions

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Datasheet PDCSY-PL-625. Technical Overview. Features. Product warranty and total quality commitment. Static Pressure Switch

Compact pressure switches for gas and air

Electromechanical pressure switches

Pneumatic spool valve islands

Further technical information is available on

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Position switches FP series

Installation, operating and maintenance Instructions for Seemag bypass level indicator

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

Instruction Manual Contact Pressure Vacuum Gauge

Model 130M Pneumatic Controller

GM Series Dual-Block Multi-Function Gas Control Valves

Z, Y, and X PURGE INDICATORS / CONTROLLERS

[Instruments for vacuum measurement, checking and adjustment] 3

Operator: Save these instructions for future use!

CFSW. Hinges with built-in safety multiple switch

Electro Controls. Level WattsIndustries.co.uk

VMR VMR-OTN VMR 6 bar

NEW TYPE M PRESSURE RELIEF DEVICE

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)

GM-7000 Series CE Approved Gas Control Valve

C645A-E Pressure Switches

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Automatic Isokinetic Sampler. ST5 Evo

INSTRUCTION MANUAL Pressure Relief Device LPT

PyroCouple Series Operators Guide

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

ALF400 to 900, ALT-5/-9

Model 601CV. Mass Flow Controller. Product Features:

Infrared Linescanners

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Relative and differential pressure module type 698

Dual Solenoid Gas Valve Installation

Glass tube flowmeters Series 2000

Electromechanical pressure switches

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Pressure switches for air and water CS

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Installing ASI Umbilical Delivery Systems

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Precision Pressure Regulators

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

36H SERIES Combination Gas Valve

Description Pressure range Connection thread Device Page

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

TECHNICAL DESCRIPTION

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Operator: Save these instructions for future use!

Aquavar SOLO 2 Frequently Asked Questions

G92 Series BASOTROL Automatic Pilot Gas Valve

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

AutoChanger Installation & User Guide Issue 2

RC 195 Receiver-Controller

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

SPECIFICATIONS CAPACITY

Operator: Save these instructions for future use!

HS653 Negative Pressure Ventilation Controller

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

MoveRoll Conveyor Operating and Maintenance Manual

INSTALLATION GUIDELINES

Operating instructions Pressure sensor. PN422x / / 2013

Pneumatic valve islands

Genie Supreme Model 123 Installation & Operation Instructions

Proportional pressure regulators VPPE

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Genie Supreme TM Model 123HP Installation & Operation Instructions

RPS900W Redundant Power Supply. Installation Guide.

Bourdon tube pressure gauges for chemical applications EN 837-1

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Operating Manual VSA100A. tina29e1 ( )

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

RLP100F910, F916, F918: Dual-channel volume flow controller

Transcription:

Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw needed for housing cover Technical Overview The PA-DPS-9x range, are high sensitivity air differential pressure switches for low differential pressure switching applications. Suitable for use in air conditioning systems to provide an indication of fan status or 'filter dirty' condition. The switching knob is mounted under the cover to avoid tampering. The scale is individually laser etched for high accuracy.

Page 2 of 5 Specification: Operating ranges: Type PA-DPS-90W PA-DPS-91W PA-DPS-92W PA-DPS-94W Max. operating pressure Pressure connections Electrical rating Connections Dimensions Housing material Fixing Protection Ambient range Installation category Origin Adjustment range 20-300Pa 50-500Pa 100-1000Pa 500-2000Pa 50 mbar (5000Pa) 6mm ID push-on tubing P1 = Hi P2 = Lo 5A(0.8A)/230Vac or 2A@30Vdc Screw terminals 81mm dia. x 52mm Plastic moulding Metal mounting bracket IP65-30 C to +85 C IEC 664 Category II Switzerland Part Codes: PA-DPS-90W 20 to 300Pa Air DP switch PA-DPS-91W 50 to 500Pa Air DP switch PA-DPS-92W 100 to 1000Pa Air DP switch PA-DPS-94W 500 to 2000Pa Air DP switch Accessories DFK TEE Duct Fixing Kit Tee-Piece (pack of 10) PA-TUBE-8MM PVC Tube 8mm o/d x 1.5mm Wall, 30m Reel The products referred to in this data sheet meet the requirements of 2006/95/EC -DPS-9x, consisting of 2m of 5mm i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws (see page 4).

Page 3 of 5 Installation: 1. The PA-DPS-9x should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the PA-DPS-9x. 3. 1. It is recommended that the unit be mounted vertically, with the pressure ports pointing downwards (Fig. 1). If the unit is mounted horizontally (Fig. 2) with the cover uppermost, the switching points will be 11Pa higher than the scale reading. If the unit is mounted horizontally (Fig. 3) with the cover facing downwards, the switching points will be 11Pa lower than the scale reading. Fig.1 Fig. 2 Fig. 3 4. If mounted externally, it is recommended that the unit be mounted with the cable entry at the bottom. If the cable is fed from above then into the cable gland at the bottom, it is recommended that a rain loop be placed in the cable before entry into the housing. 5. Remove the cover by unscrewing the single screw and terminate as required and set the desired switching pressure on the setting knob using a screwdriver. Replace the cover and tighten the single screw. Switching point adjustment 2 N/C Contact 1 Common 3 N/O Contact 1 2 3 Factory set, do not adjust 6. Push the pressure tubing onto the pressure ports on the unit. Ensure that the Hi and Lo ports have been correctly identified. P1 (+) High pressure P2 (-) Low pressure CAUTION The PA-DPS-9x will be damaged if subjected to excessive pressure. Do NOT test the unit by blowing into the inlet ports.

Page 4 of 5 Applications: If the switch is to be used for filter status monitoring, the pitot tube ends should be cut square. If the switch is to be used for fan status monitoring, the ends of the pitot tube should be cut at an angle of 45 Fan status monitoring: The switch can be used across a fan to provide proof of air flow and hence fan status. Fig. 1 shows how to connect the High and Low pressure ports: Filter status monitoring: The switch can be used across a filter to provide dirty filter status. Fig. 2 shows the connections for this application. Fig. 1 Fig. 2 - + + - Low port Fan High port High port Low port Filter Duct Fixing Kit: -DPS-9x, consisting of 2m of 5mm i/d plastic tubing, 2 x pitot tubes and 4 x fixing screws. Pitot tube dimensions; 6.3mm (0.25") 78mm (3.07") Ø 25.5mm (1") 59mm (2.32") Ø3mm (0.12") Ø 3.3mm (0.13") 45

Page 5 of 5 Dimensions: Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.