Instruction Manual BA90 Precision Barometer

Similar documents
Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Instruction Manual EMA 84 Digital Pressure Gauge

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Operating instructions Pitot Static Tube

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

EC214 EC215 - EC215R Bench Conductivity Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

High-performance submersible pressure transmitter For level measurement Model LH-10

700 SERIES BMS II BUBBLER MONITORING SYSTEM

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Precision pressure sensor Basic version Model CPT6020

Instruction Manual Contact Pressure Vacuum Gauge

User Manual PTW-DensiX. D / Di/Zi

Instruction Manual Differential Pressure Transmitter

C-Flow Coriolis Mass Flow Meters

BI-680 Online Dissolved Oxygen Controller Instruction Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

HI 2314 HI 2315 HI 23151

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Digital Melting Point Apparatus

Overview. Front Panel: Keypad and Display

KJL-205A. Operation Manual YOU MUST READ THIS MANUAL BEFORE USE

High-performance submersible pressure transmitter For level measurement Model LH-10

! Warning, refer to accompanying documents.

STAGE, STADIUM & X-TREME SHOT.

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

NovelBright LED Illuminator

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

In Vivo Scientific, LLC INSTRUCTION MANUAL

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Dual Solenoid Gas Valve Installation

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer

OEM Manual. MODEL ½ Digit DRUM SCALE

Operating Manual VSA100A. tina29e1 ( )

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Pressure maintenance valve SDV-P / SDV-P-E

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

DTG - LCD Digital Temperature Gauge USER MANUAL

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

AMS 2710 PCB pressure sensor module with V output

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

BGA158 Series CE Approved Class A Shutoff Gas Valve

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

RPS900W Redundant Power Supply. Installation Guide.

Pneumatic high-pressure controller Model CPC7000

GasSense NDIR User Manual

DIRECTIONS FOR USE / ASSEMBLING

Columbus Instruments

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Version-E E100930

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operation Manual. O2 Quickstick. Oxygen Analyzer

Instruction Manual Differential Pressure Transmitter

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

PRAHER PLC-MP AQUASTAR MANAUL 2009

Peak Pressure Indicator MSI-3

BGA158 Series CE Approved Class B Shutoff Gas Valve

Installation, operating and maintenance Instructions for Seemag bypass level indicator

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

User s Guide Temperature Sensor Converter TSC-599

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Operating Instructions Temperature Measuring System MF420-5T-100

ASDX Series Silicon Pressure Sensors

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

92831 TEL: (714) FAX:

Gas density monitor With integrated transmitter Model GDM-100-TI

Transmitter CS 21 Operation Manual

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Climatic Independent Level Sensor LAR

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY

AMS 6916 Board mount pressure sensor with ratiometric analog output

Pressure Switch for gas and air GGAO-A4

92831 TEL: (714) FAX:

Pneumatic high-pressure controller Model CPC7000

Installation and Operating Instructions Bypass Flow Meter DST

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

KERN EG/EW Version /02

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Declaration of Conformity as per Directive 97/23/EC

Endura AZ40 Sensor assembly Smart electronics PCB

Transcription:

Instruction Manual BA90 Precision Barometer halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com Internet: www.halstrup-walcher.com Document 7100.003534 Version 1.1 07/2007

Table of contents 1 Safety precautions... 4 1.1 Appropriate use... 4 1.2 Shipping, assembly, electrical connections and startup... 4 1.3 Troubleshooting, maintenance, repairs, disposal... 4 1.4 Symbols... 5 2 Instrument description... 6 3 Electrical connections... 6 4 Reducing display values... 7 5 Troubleshooting... 8 6 Technical data... 9 7 Dimension drawing... 10 8 Barometric pressure as function of sea level... 11 2

Purpose of this instruction manual This instruction manual describes the features of the BA 90 precision barometer and provides guidelines for its use. Improper use of this instrument or failure to follow these instructions may cause injury or equipment damage. All individuals responsible for operating this instrument must therefore be properly trained and aware of the hazards, and must carefully follow these operating instructions and the safety precautions detailed within. Contact the manufacturer if you do not understand any part of this instruction manual. Handle this manual with care: It must be readily available throughout the lifecycle of the instrument. It must be provided to any individuals who assume responsibility for operating the instrument at a later date. It must include any supplementary materials provided by the manufacturer. The manufacturer reserves the right to continue developing this instrument model without documenting such development in each individual case. The manufacturer will be happy to determine whether this manual is up-to-date. Conformity This instrument corresponds to the state of the art and meets all legal requirements set forth in EC directives as evidenced by the CE label. 2005 The manufacturer owns the copyright to this instruction manual. This manual contains data, instructions and drawings pertaining to the features and usage of this instrument; copying this manual in part or in full or distributing it to third parties is prohibited. 3

1 Safety precautions 1.1 Appropriate use The BA 90 precision barometer is used for measuring the prevailing barometric pressure at the location where it has been installed. Always observe the operating requirements particularly the permissible supply voltage indicated on the rating plate and in the Technical data section of this manual. The instrument may only be handled as indicated in this manual. Modifications to the instrument are prohibited. The manufacturer is not liable for damages caused by improper use or failure to follow these instructions. Such violations render all warranty claims null and void. 1.2 Shipping, assembly, electrical connections and startup Do not close the pressure inputs when shipping, as changes in barometric pressure could damage instruments with low measuring ranges. Only technical personnel who are appropriately trained and authorized by the operator of the facility may assemble the instrument and set up its electrical connections. The instrument may only be operated by appropriately trained individuals who have been authorized by the operator of the facility. Pressurized air or human breath is not to be used for performance tests, as this could damage instruments with low measurement ranges. Measurement errors may occur if the instrument is not kept protected from sunlight. Specific safety precautions are given in individual sections of this manual. 1.3 Troubleshooting, maintenance, repairs, disposal The individual responsible for the electrical connections must be notified immediately if the instrument is damaged or if errors occur that cannot be corrected as indicated in section 5. This individual must take the instrument out of service until the error has been corrected and ensure that it cannot be used unintentionally. Always unplug the power cord before opening the instrument! This instrument requires no maintenance. Only the manufacturer may perform repairs that require the housing to be opened. The electronic components of the instrument contain environmentally hazardous materials and materials that can be reused. For this reason the instrument must be 4

recycled in accordance with the environmental guidelines of the jurisdiction in question once it has been taken permanently out of service. 1.4 Symbols The symbols given below are used throughout this manual to indicate instances when improper operation could result in the following hazards: WARNING! This warns you of a potential hazard that could lead to bodily injury up to and including death if the corresponding instructions are not followed. WARNING: This warns you of a potential hazard that could lead to significant property damage if corresponding instructions are not followed. INFORMATION This indicates that the corresponding information is important for operating the instrument properly. 5

2 Instrument description The BA90 precision barometer measures the barometric pressure at the location where it has been installed; pressure range = 913.3 hpa to 1113.3 hpa. It is important to keep in mind that atmospheric pressure varies according to the altitude of the installment site. Meteorological measurements of barometric pressure, however, are adjusted to sea level values (SLP = Sea Level Pressure) using a process known as reduction. The BA90 allows operators to reduce the displayed value themselves. This requires knowing the height of the measuring station above sea level. (This information is often found in a building s floor plan.) The display values do not need to be reduced if installing the BA90 on the sea coast. Atmospheric pressure at higher altitudes is less than at sea level and varies according to an altitude-dependent formula. Typical variations in barometric pressure are in the area of +/- 30 hpa. 3 Electrical connections Terminals located on the rear wall of the instrument s housing are used for connecting the instrument to the power supply and analog output. Note that the instrument can accommodate three possible power supply options: every BA90 can be operated on 230 VAC, 115 VAC or 12-28 VDC by applying the desired supply voltage to the corresponding terminal. Do not connect anything to unused supply terminals! If using a 12-28 VDC power supply, the analog output and power supply should NOT be galvanically separated. The type of analog output (+/-2 V, 0...20 ma or 4...20 ma) must be indicated when placing the order, as this cannot be reset after the fact. Cable connectors: 3-pin screw terminal for power supply: Phönix, MC1.5/3-STF-5.08 4-pin screw terminal for DC power supply and analog output: MC1.5/4-STF-3.81 6

4 Reducing display values BA 90 Instruction Manual The reduction potentiometer (lower left) may be accessed by removing the front panel. reduction potentiometer The instrument is set to SLP at the factory (reduction potentiometer on left-hand block). - Allow the instrument to warm up for 5 hours - Look in the table to find the differential value (correction factor) corresponding to the altitude of the location where the barometer has been installed. Add this value to the displayed value. - Set the resulting new value on the display by the turning the reduction potentiometer to the right Example: Barometer location: Kirchzarten, 390 m above sea level Correction factor: 46.0 hpa Displayed value: e.g., 971.4 hpa Use reduction potentiometer to adjust display as follows: 971.4 hpa + 46.0 Pa = 1017.4 hpa Reduction can be performed for an altitude of up to 860 m above sea level. An analog output (voltage or current signal) which also shows the reduced display value is available if you wish to process the measured value further. 7

5 Troubleshooting Problem Cause Corrective Action Instrument does not work, Display does not light up No power Check to see if the electrical cord is plugged in properly Check to see if the supply Instrument does not work, Display does not light up Defective component voltage is available Send the instrument to the manufacturer for repair 8

6 Technical data Measurement data measurement ranges accuracy resolution reduction long-term drift 913.3 hpa to 1113.3 hpa 0.5 hpa with respect to sea level 0.1 hpa 0..850 m above sea level, via potentiometer 0.3 hpa / year Ambient conditions medium air operating temperature +10 C to +50 C storage temperature -10 C to +70 C temperature effect ±0.2 hpa/ C within a temperature range of 20 50 C calibration temperature 22 C relative humidity 0 80 % EMC standards EN 61000-6-3, EN 61000-6-1 conformity Declaration of conformity available upon request Electrical data power consumption supply voltage options electrical connections output signals 3 VA 230 VAC/115 VAC +6 %/ -15 % (50 60 Hz) 12 28 VDC Supply voltage may be selected by connecting to corresponding terminal Phönix screw terminals power supply: MC1.5/3-STF-5.08 DC power supply and analog output: MC1.5/4- STF-3.81-2 +2 V (RL 5 kω) or 0 20 ma (RL 250 kω) or 4 20 ma (RL 250 kω) (please indicate when placing order) display red, 7-segment LED display, h=14mm Physical data dimensions (w x h x d) 96 x 96 x 119 mm panel housing (DIN 43700) weight 0.8 kg operating position horizontal positional error ±0.1 hpa for every 10 of inclination 9

7 Dimension drawing 10

8 Barometric pressure as function of sea level Barometric pressure as funktion of sea level and difference to 1013,3 hpa (according to DIN ISO 2533) above sea level in meters difference in hpa above sea level in meters difference in hpa above sea level in meters difference in hpa 0 0,0 500 58,6 1000 114,5 10 1,2 510 59,8 1010 115,6 20 2,4 520 60,9 1020 116,7 30 3,6 530 62,1 1030 117,8 40 4,8 540 63,2 1040 118,9 50 6,0 550 64,4 1050 119,9 60 7,2 560 65,5 1060 121,0 70 8,4 570 66,6 1070 122,1 80 9,6 580 67,8 1080 123,2 90 10,8 590 68,9 1090 124,3 100 12,0 600 70,0 1100 125,4 110 13,1 610 71,2 1110 126,4 120 14,3 620 72,3 1120 127,5 130 15,5 630 73,4 1130 128,6 140 16,7 640 74,6 1140 129,7 150 17,9 650 75,7 1150 130,7 160 19,1 660 76,8 1160 131,8 170 20,3 670 77,9 1170 132,9 180 21,4 680 79,1 1180 134,0 190 22,6 690 80,2 1190 135,0 200 23,8 700 81,3 1200 136,1 210 25,0 710 82,4 1210 137,2 220 26,2 720 83,6 1220 138,2 230 27,3 730 84,7 1230 139,3 240 28,5 740 85,8 1240 140,4 250 29,7 750 86,9 1250 141,4 260 30,8 760 88,0 1260 142,5 270 32,0 770 89,1 1270 143,6 280 33,2 780 90,3 1280 144,6 290 34,4 790 91,4 1290 145,7 300 35,5 800 92,5 1300 146,7 310 36,7 810 93,6 1310 147,8 320 37,9 820 94,7 1320 148,8 330 39,0 830 95,8 1330 149,9 340 40,2 840 96,9 1340 151,0 350 41,3 850 98,0 1350 152,0 360 42,5 860 99,1 1360 153,1 370 43,7 870 100,2 1370 154,1 380 44,8 880 101,3 1380 155,2 390 46,0 890 102,4 1390 156,2 400 47,1 900 103,5 1400 157,3 410 48,3 910 104,6 1410 158,3 420 49,4 920 105,7 1420 159,4 430 50,6 930 106,8 1430 160,4 440 51,8 940 107,9 1440 161,4 450 52,9 950 109,0 1450 162,5 460 54,1 960 110,1 1460 163,5 470 55,2 970 111,2 1470 164,6 480 56,4 980 120,3 1480 165,6 490 57,5 990 113,4 1490 166,7 500 58,6 1000 114,5 1500 167,7 7100.003534_BA90_eng.doc 01.02.2018 ka/ze 11