Training Device Instructions

Similar documents
Parts identification:

Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Puffin Sport and Saco

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

AT Kelly Torso. Directions for Use

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

Skin and Vein Replacement Kit LF01122U (Light Skin) LF01123U (Dark Skin) LF01124U (Vein) Instruction Manual

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Puffin Sport Assembly and User Information

Port - Body in a Box User s Manual

Assembly Instructions. for. Puffin Saranac. ScanSport, Inc. P.O. Box 700 (234 May Street) Enfield, New Hampshire Phone: (603)

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

OFS LT1B Instruction Sheet Splice Organizer Comcode: D02AK0025 Installation

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

Inflatable Dock Slide Owner s Manual

Infant IV Leg LF03636U Instruction Manual

Ultrasound Guided Thoracentesis Simulator

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

PANACEA P100 LOW PRESSURE USER MANUAL

AT Kelly Torso. Directions for Use

Instant Garage 20' x 12' 3" x 8' 3"

INSTRUCTION MANUAL. January 23, 2003, Revision 0

CHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U

Study & Manipulative Training Guide

5/16 MAXFLOW SPOUTS 17/64 MAXFLOW SPOUTS. 5/16 black spout with barbs $0.25 $ /64 white spout without barbs. 5/16 white spout without barbs

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

Skin and Vein Replacement Kit LF01122 (White Skin) LF01123 (Black Skin) LF01124 (Vein)

INJECTABLE TRAINING ARM

CRiSis System Defibrillation Chest Skin LF03652U Instruction Manual

Instructions and User Guide. Ultrasound Musculoskeletal Training Model BPMSK-1000 Series. April 26, 2016 Rev 1.0

MODEL #7100X A-FRAME LADDER

Patient Sleep Test Hookup

M176-0~3 New Aged Simulation Suit S Size, M Size, L Size, LL Size

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

Vitrex Steriheel Baby Sterile Cutting Safety lancet

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Advanced IV Hand LF01139U & LF01146U Instruction Manual

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

3, 4 & 5m 3 Single Mast Systems User Guide

HoldUp Plus2. Safety Kit included: See additional instructions for installation. REAR WHEEL TRAY. BASE (1x) lock WASHER (1x) KEY (2x) SAFETY CLIP (1x)

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Nita Newborn Model 1800 User Manual

Ultrasound Guided Thoracentesis / Pericardiocentesis Simulator Full set

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Chester Chest Model 2400 User s Manual

Chester Chest Model 2400 User s Manual

CODE CODE DOZEN LENGHT SIZE

REDMAN SUIT ASSEMBLING AND PACKING INSTRUCTIONS

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Trampoline & Enclosure Assembly Instructions

Pontoon Slide Owner s Manual

Basic Flows in a Microfluidic Device

Dual Electronic Basketball System Owners Manual

Pole & Tree Climbers. Pole & Tree Climbers. 1972AR Series. Pole Climbers with 1-1/2" Gaffs Complete Set

Device-Related Pressure Ulcer/Injury Prevention Cervical Collar Recommendations and Guidance

Information for patients and nurses. Rocket Ambulatory Chest Drain

Pontoon Slide Owner s Manual

Child CRiSis Injectable Training Arm LF03612U Instruction Manual

Handle the film very carefully. As with aluminum foil, once creased, the film will remain creased.

Safety Huber Needles

SETTING THE HANDLE HEIGHT ON THE ROLLATOR

35 TON HYDRAULIC PUNCH WARNING

User manual STARLOCK. Careways International - Innovation Quality Performance

QUIK-jet Micro-Injection System

Installation Instructions

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

INSTALLATION INSTRUCTIONS

Peripheral Venous Catheter Placement Simulator

Parts of the Gun. Specifications XCR-C XCR-L. Optic Rail. Charging Handle. Sling Loop. Accessory Rails. Crane Stock. Flash Hider. Stock Pad.

Canine Endotracheal Intubation

CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL

Trilogy Theory of Operation

Speed control assembly model A-1

Shimano Di2 Installation on S5

CS CANNULATION. Step-by-Step Guide. This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY

PART NUMBER: E361SXA200 DESCRIPTION: KAYAK CARRIER

Pakboats PakCanoe Assembly Instructions

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

275 RID Assembly Instructions

USER MANUAL. you pedal, something amazing happens

Le Maitre Ltd. Co2 propelled Electric Air Cannon Instructions. & Loading instructions for Chinese Confetti, Streamers and Glitter

Airway Larry Airway Management Trainer Head LF03667U Instruction Manual

CVC Insertion Simulator

On the Go Swing System Instruction Manual

Patient Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Prop Racer System. User Guide V0210

Pontoon Slide Owner s Manual

extricare NPWT Foam Kit Instruction for Use

*******WARNING******

Trampoline & Enclosure Assembly Instructions

PRODUCT CATALOGUE OF

INDEX

Transcription:

Training Device Instructions May 2011 www.pyng.com 2011 Pyng Medical Corp.

Pyng Medical has developed two types of devices to aid in the training curriculum of the FAST1 : The FAST1 Training Device and The SimIO Training Device. FAST1 Training Device The FAST1 Training Device (also referred to as the Demo Introducer ) allows students to practice on a device very similar to the actual FAST1 and to become acquainted with proper deployment and safety procedures. As a training device, the FAST1 Trainer can be re-set and re-used multiple times. The FAST1 Training Device is used on simulated devices such as the SimStern, allowing students to get hands-on experience with a similar replicate of the device and get a feel for how the device really works. SimIO Simulator System The SimIO Training Device (also referred to as the SimIO Introducer ), a simulated FAST1 device, is used to practice the FAST1 Intraosseous Infusion System on volunteer patients and allows for realistic practice scenarios without needles. The SimIO Training Device duplicates all aspects of the FAST1, except for actual penetration of the skin or sternum by the Stabilizer Needles or Infusion Tube. The Stabilizer Needles and Infusion Tube have been replaced with a hook-sided Velcro patch that is attached to the end of the Infusion Tube. The SimIO Infusion Tube is held in place on the Target Patch by a Velcro loop-sided fastener. Since the SimIO Training Device does not contain any needles or sharps, it can be deployed on a live person in order to practice emergency scenarios. More information follows on how to use these devices, as well as how to reset them for repeated usage. Pyng Medical Corp. www.pyng.com 1

FAST1 TRAINING PRODUCT CATALOG FAST1 Training System RTR 01-0144 SimIO System, 01-0115 (see below for parts) Target Patch, 01-0026 Reset Tool, 01-0036 Demo Introducer, 01-0150 SimStern Thick Normal, 01-0051 SimStern Thin Normal, 01-0053 Demo Kit Spare Parts Pkg, 01-0157 Post-Use Sharps Plug, 01-0033 SimIO Infusion Tube, 01-0012 Stylet Supports, 02-0018 Infusion Tube, 01-0174 SimIO Accessories - 10 Pack, 01-0058 SimStern Marrow, 02-0098 Instructions for Use, 04-0057 Training System Carrying Case - Clear, 04-0085 Training DVD, 07-0104 FAST Poster, PM-026 SimIO System 01-0015 SimIO Patch, 01-0027 SimIO Introducer, 01-0047 Dome, 01-0104 SimIO Unit Package Label, 04-0090 SimIO Accessories (10 pack) 01-0058 Pyng Medical Corp. www.pyng.com 2

FAST1 TRAINING PRODUCT CATALOG SimIO Introducer (also referred to as SimIO Training Device ) 01-0047 SimIO Target Patch 01-0027 SimIO Infusion Tube 01-0012 Dome (also referred to as Protector Dome ) 01-0104 Demo Introducer (also referred to as FAST1 Training Device ) 01-0150 Infusion Tube 01-0174 Pyng Medical Corp. www.pyng.com 3

FAST1 TRAINING PRODUCT CATALOG Reset Tool 01-0036 SimSternal SimStern Marrow - 02-0098 SimStern Thick Normal - 01-0051 SimStern Thin Hard - 01-0052 SimStern Thin Normal - 01-0053 Target Patch 01-0026 Post-Use Sharps Plug (also referred to as Sharps Foam Plug ) 01-0033 Pre-Use Sharps Cap (also referred to as Sharps Protection Cap ) 02-0022 Stylet Supports (pair) 02-0018 Pyng Medical Corp. www.pyng.com 4

FAST1 TRAINING DEVICE INSTRUCTIONS DEPLOYMENT 1. Place Target Patch on a SimStern block (yellow foam with plastic over white foam). a. The clear, hard plastic represents the bone. b. The yellow foam represents the skin and fat tissue. c. The white Styrofoam represents the marrow. 2. Peel off tabs #1, then #2 and adhere to SimStern block. 3. Hold FAST1 Training Device in dominant hand (or as comfortable). 4. Remove the Sharps Protection Cap from the FAST1 Training Device. Pyng Medical Corp. www.pyng.com 5

5. Place Stablizer Needles in the Target Zone of the Target Patch, perpendicular to the SimStern block. 6. Press down with firm and increasing force until the Introducer releases. 7. Pull the FAST1 Training Device straight back to separate the Handle from the Infusion Tube, which is now inserted into the SimStern bone. 8. Push the Stabilizer Needles straight into the red Sharps Foam Plug and reattach Sharps Protection Cap. This is a one-handed procedure and the Sharps Foam Plug must remain on the table/ surface and NOT be picked up. Pyng Medical Corp. www.pyng.com 6

9. Remove BLUE cap and connect the Infusion Tube to the connector tubing attached to the Patch. Remove the WHITE cap from Luer fitting and connect IV tubing. 10. Secure Protector Dome to Target Patch. REMOVAL 11. Remove the Protector Dome. 12. Disconnect the IV line from the Connector Tube on the Target Patch and the friction fitting from the Infusion Tube. 13. To remove, grip as close to the lower end of the Infusion Tube as possible. Pull the Infusion Tube out from the SimStern bone. Note: Pull in one continuous motion (do not start/stop) until removed. Use the Tube to pull, not the Luer connection. It is normal for the tubing to stretch. Pyng Medical Corp. www.pyng.com 7

RESETTING THE FAST1 TRAINING DEVICE RESETTING THE STABILIZER NEEDLES 1. Remove the Sharps Protection Cap and/or Sharps Foam Plug. 2. Ensure that there is no Infusion Tube on the Stylet. 3. Reset the FAST1 Training Device using the Reset Tool. Insert the Reset Tool through the small hole in the distal end (opposite end from the Stabilizer Needles) of the FAST1 Training Device. 4. Hold the FAST1 Training Device in one hand and the Reset Tool in the other, so that the Reset Tool can be pushed while keeping the Stabilizer Needles pointed away from you and anyone else. Warning: When you reset the Training Device, its sharp Stabilizer Needles will snap forward into place. Keep fingers well away from this end. 5. Reset the FAST1 Training Device by pushing on the Reset Tool (as shown) until the Stabilizer Needles snap forward into place. Remove the Reset Tool. The Stabilizer Needles are now reset. Pyng Medical Corp. www.pyng.com 8

REPLACING THE INFUSION TUBE AND STYLET SUPPORTS Warning: The Stabilizer Needles are very sharp. Use caution when replacing the Infusion Tube and Stylet Supports. Use the Reset Tool to prevent needle stick injuries. 1. After the Stabilizer Needles have been reset, place the Infusion Tube into the center of the Stabilizer Needles. Ensure the Stylet enters the Infusion Tube. Be careful not to puncture the Tube with the Stylet tip. 2. Use the Reset Tool to seat the stainless steel bone portal tip on the tip of the Stylet. 3. Pick up one Stylet Support. Loosely place its bulb end into the bore of the Stabilizer Needles, on one side of the Infusion Tube. The bulb end must face into the Introducer. Pyng Medical Corp. www.pyng.com 9

4. Hold the Reset Tool as shown to push the Stylet Support gently into the bore until it clicks into place. The Reset Tool will slide between the needles. Once in place, the end of the Stylet Support should be approximately flush with the proximal face of the bone probe. Note: Holding the Reset Tool as shown prevents over-insertion of the Stylet Supports. 5. Repeat steps 3 and 4 with the second Stylet Support. Be careful to insert the second Stylet Support on the opposite side of the Infusion Tube from the first support. Ensure the Stylet Support is inserted bulb end first. 6. Replace the Sharps Protection Cap. The FAST1 Training Device is now reset and reloaded. It is ready to be used in the SimStern. Pyng Medical Corp. www.pyng.com 10

FAST1 SIMIO TRAINING DEVICE INSTRUCTIONS DEPLOYMENT 1. Have volunteer patient lay down on the floor in the supine position. Expose sternum and locate the sternal notch by placing index finger in the notch. 2. Place SimIO Target Patch on patient by removing the adhesive backing. Pull off tabs #1, then #2 and adhere. 3. Stand at the patients head and hold the SimIO Training Device in dominant hand (or as comfortable). Place the hook-sided Velcro Patch that is on the SimIO Training Device, on the Target Zone of the SimIO Target Patch (loop-side). Hold SimIO Training Device perpendicular to the manubrium. 4. Press down smoothly with increasing force until you hear the Infusion Tube separate from the SimIO Training Device. Pyng Medical Corp. www.pyng.com 11

5. Pull SimIO Training Device up, off of the SimIO Infusion Tube. 6. Remove BLUE cap and connect the SimIO Infusion Tube to friction fitting on tubing attached to the SimIO Target Patch. Remove WHITE cap from Luer fitting and connect IV tubing. 7. Secure Protector Dome to SimIO Target Patch.. Pyng Medical Corp. www.pyng.com 12

REMOVAL 8. Remove the Protector Dome. The SimIO Target Patch may have to be held down while the Dome is being removed. 9. Disconnect the IV line from the Connector Tube on the SimIO Target Patch and the friction fitting from the SimIO Infusion Tube. 10. Remove the SimIO Infusion Tube from the SimIO Target Patch by disengaging the Velcro fastening. 11. Remove the SimIO Target Patch. Pyng Medical Corp. www.pyng.com 13

RESETTING THE SIMIO TRAINING DEVICE 1. Reset the SimIO Training Device by using the Reset Tool. Insert the Reset Tool through the small hole in the distal end (opposite end from the Velcro Patch) of the SimIO Training Device. 2. Push the Reset Tool forward until the SimIO Foot snaps into place. Remove the Reset Tool. 3. Insert the SimIO Infusion Tube, Luer end first, into the SimIO Foot. The Foot is magnetized and will attach itself to the SimIO Infusion Tube. 4. The SimIO Training Device is now reset and reloaded, and is ready to be re-used.. Pyng Medical Corp. www.pyng.com 14