MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer

Similar documents
NovelBright LED Illuminator

Digital Melting Point Apparatus

The Univentor 1250 Anaesthesia Unit

PPS PORTABLE POWER SUPPLY

Instruction Manual BA90 Precision Barometer

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

In Vivo Scientific, LLC INSTRUCTION MANUAL

EC214 EC215 - EC215R Bench Conductivity Meters

HI 2314 HI 2315 HI 23151

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Technical Data Sheet MF010-O-LC

Stirring Water Bath. Instruction Manual

KERN EG/EW Version /02

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

INSTALLATION & MAINTENANCE INSTRUCTIONS

OPERATION MANUAL FOR VP 710E-3HM SERIES ALLIGATOR TUMBLE STIRRERS *US Patent # 6,176,609

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

THE UNIVENTOR 400 ANAESTHESIA UNIT

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Operating Manual VSA100A. tina29e1 ( )

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

DIRECTIONS FOR USE / ASSEMBLING

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Instruction Manual EMA 84 Digital Pressure Gauge

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

MODEL NUMBER: AS18-2 USER GUIDE

8675/8677/8678 OWNER S MANUAL

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

BGA244 Binary Gas Analyzer

DIRECTIONS FOR USE / ASSEMBLING

TrekMill USER'S MANUAL MM5050

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Digital Vacuum Regulator

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

AIR INLINE METAL SHEAR

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Discovery HP-TGA 75/750. Site Preparation Guide

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Sample Concentrator SBH CONC/1 Instructions for use

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Advanced Test Equipment Rentals ATEC (2832)

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

A17W49_MASEM_F_EN MANUAL

Flamco Flamco-Fill STA Flamco-Fill STM

ATEX ATEX

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

User Manual PTW-DensiX. D / Di/Zi

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

DIRECTIONS FOR USE / ASSEMBLING

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

Safety instructions and operating manual

New AQF Filter Polymer Filtration System

12V MINI AIR COMPRESSOR

Pressure Relief Valve Instruction Manual

BGA158 Series CE Approved Class A Shutoff Gas Valve

USER MANUAL

Operating Instructions Temperature Measuring System MF420-5T-100

Hole cutter. Model 97194

SPS-5. Rate Computing Scale. Operation Manual

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

12V Mini Air Compressor

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Research Grade Blood Pressure Transducer User's Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

INSTRUCTIONS PARTS LIST

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Temperature gauge Installation Guide

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Portable oxygen concentrator

Installation, operating and maintenance Instructions for Seemag bypass level indicator

HAS2400 Hepa Air Scrubber

5 Channel Calibrator

Control units. Installation and operating instructions Series: DP-Control

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Level switches Series LD Vibrating fork level switch for liquids and solids

DPC-30 DPC-100. Reference Manual

GALISO SOAP OPTION FOR PCT-ADW-D

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Miris Ultrasonic Processor

USER MANUAL. JET TST and JET TST S.

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Heavy-Duty Hot Knife

ATEX installation and service instruction

Transcription:

MS-H-S10/MS-M-S10 Hotplate/Magnetic Stirrer User Manual MS-H-S10 10-Channel Analog Hotplate Magnetic Stirrer MS-M-S10 10-Channel Analog Hotplate Magnetic Stirrer Please read the User Manual and the related Video of this instrument on our website carefully before use, and follow all operating and safety instructions! The website www.scilogex.com Cat No.12300136

Contents Contents 1 Preface 2 Service 2 Warranty 2 1 Safety Instructions 3 2 Propervse 4 3 Inspection 4 3.1 Receiving Inspection 4 3.2 Listing of Items 4 4 Trial run 5 5 Control Elements 5 6 Operation 6 7 Faults 6 8 Maintenance and Cleaning 6 9 Associated Standards and Regulations 7 10 Technical Data 7 11 Products and Accessories 8 1

MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer Preface Welcome to the 10-Channel Analog Hotplate Magnetic Stirrer User Manual. Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument. Service When help needed, you can always contact the sevice department of manufacturer for technical support in the following ways: SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel:1- (860) 828-5614 Fax:1- (860) 828-5389 E-mail: info@scilogex.com Website:Http://www.scilogex.com Description of problem (i.e., hardware or software) Methods and procedures adopted to resolve the problems Your contact information Warranty You have purchased a scilogex instrument. This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation. For claims under the warranty please contact your local dealer. You may also send the instrument direct to our works, enclosing the invoice copy and by giving reasons for the claim. You would be solely liable for freight costs. Please provide the customer care representative with the following information: Serial Number(on the rear panel) 2

1 Safety Instructions Warning! Read the operating instructions carefully before using the instrument. Ensure that only trained staff work with the instrument. Forbid to heat the substances with lowburning point or easy-volatile(ms-h-s10) Risk of burn! Caution when touching the housing parts and the heating plate. The heating plate can reach temperatures of 120. Pay attention to the residual heat after switching OFF the instrument. Protective ground contact! Make sure that socket must be earthed (protective ground contact) before use. When work,wear the personal guard to avoid the risk from: - Splashing and evaporation of liquids - Release of toxic or combustible gases. Set up the instrument in a spacious area on an stable, MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer clean, non-slip, dry and fireproof surface, do not operate the instrument in explosive atmospheres, with hazardous substances or under water. Gradually increase the speed. Reduce the speed if : - The stirring bar breakaway because of too high speed - The instrument is not running smoothly, or container moves on the base plate. Temperature must always be set to at least 25 lower than the burning point of the media used. Beware of hazards due to: - Flammable materials or media with a low boiling temperature - Overfilling of media - Unsafe container Process pathogenic materials only in closed vessels. If the case of the stirrer bar is PTFE,please note: - Elemental fluorine, three fluoride and alkali metals will corrode the PTFE and Halogen alkanes make it expansion at room temperature - Molten alkali,alkaline earth metals or their solution, as well as the powder in second and third ethnic of the periodic table of elements will have chemical reaction with PTFE when temperature reaches 300 ~ 400. The voltage stated on the label must correspond to the main power supply. 3

MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer Ensure that the mains power supply cable does not touch the heating base plate. Do not cover the device. The instrument may only be opened by trained experts Keep away from high magnetic field. Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm). >100mm >100mm mentioned in Chapter 1. 3 Inspection 3.1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen during transport. If it happens, please contact manufacturer for technical support. Note: If there is any apparent damage to the system, please do not plug it into the power line. 3.2 Listing of Items 2 Proper use Figure 1 The instrument is designed for mixing and/or heating liquids in schools, laboratories or factories. This device is not suitable for using in residential areas or other constraints The packing includes the following items: Items Qty Main unit 1 Power cable 1 Stirrer bar 2 User manual 1 Table 1 4

4 Trial run Make sure the required operating voltage and power supply voltage match. Ensure the socket must be earthed. Ensure the power be off and the speed control knob and the temperature control knob at the lowest position Plug in the power cable,ensure the power be ON(Figure 3) Add the medium into the vessel with a stirring bar. Put the vessel above spots on the plate. Turn the speed control knob slowly to the ideal scale Turn the temperature control knob slowly to the ideal scale(ms-h-s10) Keep the temperature control knob and the speed control knob slowly to the lowest position to turn off the function. If these operations above are normal, the device is ready to operate. If these operations are not normal, the device may be damaged during transportation, please contact manufacturer for technical support. MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 5 Control elements Power LED Temperature control knob (MS-H-S10) Items Speed control knob Temperature control knob (MS-H-S10) Speed control knob Figure 2 Figure 3 working plate Stirring point Descriptions Set the rated rotary speed in the safe stirring range from 0 to 1100 rpm. The function Stirring is switched ON or OFF via the knob. Set the rated temperature in the safe temperature range from room temperature to 120. The function heating is switched ON or OFF via the knob. 5

MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer LED Power Mains switch 6 Operation When the device is switched ON, the LED power is lit. Switch ON or OFF. Table 2 Ensure the temperature control knob and the speed Control knob at the lowest position.put the device on the stable and safe place and plug in the mains power. Turn ON the power switch and LED power is lit. Turn the speed control knob to set the rated rotary speed in the safe speed limit from 0 to 1100 rpm. Turn the temperature control knob to set the rated temperature in the safe limit from room temperature to 120 (MS-H-S10). The device begins to work. 7 Faults Note: If there is any apparent damage to the system, please do not plug it into the power line. If a unit fault happens, please power down the instrument. Switch ON the unit again. The stirring function will continue to operate at the speed set point before the fault took place. The heating function will continue to operate at the set point before the fault took place. If the problem is not solved, please contact the technical service center. 8 Maintenance and Cleaning Proper use and maintenance can keep instruments working in a good state and lengthen its life time. Be careful not spray the cleanser into the instrument when cleaning. Unplug the power line when cleaning. Only use cleanser that we advised as below: Dyes Construction materials Cosmetics Foodstuffs Fuels Isopropyl alcohol Water containing tenside / isopropyl alcohol Water containing tenside / isopropyl alcohol Water containing tenside Water containing tenside Table 3 Other method,please contact manufacturer. Wear the proper protective gloves during cleaning of the instrument. 6

Before using other method for cleaning or decontamination, the user must contact the manufacturer ascertain that this method does not destroy the instrument. The instrument must be cleaned and put it into the initial packaging carton before sending to service for repair, avoiding the contamination of hazardous. Use the instrument in a dry clean room and temperature stable environment. 9 Associated standards and regulations Construction in accordance with the following safety standards: EN 61010-1 UL 3101-1 CAN/CSA C22.2(1010-1) EN 61010-2-10 Construction in accordance with the following EMC standards: EN 61326-1 Associated EU guidelines: EMC-guidelines: 89/336/EWG Machine guidelines: 73/023/EWG MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 10 Technical data Items Parameters Voltage [VAC] 200-240/100-120 Frequency [Hz] 50/60 Power [W] 20(MS-M-S10) 490(MS-H-S10) Stirring point position quantity 10 Max. stirring quantity of single stirring position(h 2 O) [L] 0.4 Stirring position interval [mm] 90 Single stirring position speed error [%] 5 Max. stirring quantity (H 2 O) [L] 4 Max. magnetic bar [mm] 30 Motor type External rotor brushless motor Motor rating input [W] 12 Motor rating output [W] 4 Speed range [rpm] 0 1100 Speed display Scale Heating Power[W] 470(MS-H-S10) Tempeature range[ ] RT~120(MS-H-S10) Temperature display[ ] Scale(MS-H-S10) 7

MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer Material of plate Silicone Films Dimension of plate [mm] 180 450 Dimensions (W D H) [mm] 182 552 65 Weight [kg] 3.2 Permitted ambient temperature[ ] 5-40 Permitted relative humidity 80% Protection class acc. to DIN 60529 IP42 Table 4 11 Products and Accessories Cat.No. Description 811321019999 M S - H - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer With Heat,Cn 811321029999 M S - H - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer With Heat,USA plug,110v/50hz/60hz 811321039999 M S - H - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer With Heat,Euro 811321049999 M S - H - S 1 0 1 0 - C h a n n e l A n a l o g M a g n e t i c S t i r r e r Wi t h H e a t, UK 811321089999 M S - H - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer With Heat,USA 811311019999 M S - M - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer Without Heat,Cn 811311029999 M S - M - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer Without Heat,USA plug,110v/50hz/60hz 811311039999 M S - M - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer Without Heat,Euro 811311049999 M S - M - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer Without Heat,UK 811311089999 M S - M - S 1 0 1 0 - C h a n n e l A n a l o g Magnetic Stirrer Without Heat,USA Accessories Cat.No Description 18900006 Stirring bars(10mm x 6mm),1pcs/pk 18900007 Stirring bars(15mm x 8mm),1pcs/pk 8

MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 18900008 Stirring bars(20mm x 8mm),1pcs/pk 18900009 Stirring bars(25mm x 8mm),1pcs/pk 12500005 Stirring bars(30mm x 6mm),1pcs/pk 18900011 Stirring bars(40mm x 8mm),1pcs/pk 18900015 Stirring bar mover,1pc Table 5 SCILOGEX, LLC 1275 Cromwell Ave. Suite C6 Rocky Hill, CT 06067 USA Tel: +1(860) 436-9221 Fax: +1(860) 436-9745 info@scilogex.com www.scilogex.com