COMPRESSED AIR TEXTILES ENERGY EFFICIENCY

Similar documents
Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Optimizing Compressed Air Storage for Energy Efficiency

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

Ingersoll Rand. X-Series System Automation

Understanding Centrifugal Compressor Capacity Controls:

QGV Series. Quincy QGV Series. Rotary Screw Air Compressors hp

FACT SHEET 1. Compressed Air System Selection and Efficient Production. How to save energy, reduce costs and help the environment

Net$ync II. Net$ync II. System Controllers

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Screw Compressors 11-22kW

COMPRESSED AIR SYSTEMS AND ENERGY SAVINGS

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

MARITIME PROTECTION NITROGEN SYSTEM

TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM

Which compressed air system design is right for you?

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

ENS-200 Energy saving trainer

COMPRESSED AIR DISTRIBUTION SYSTEMS

Introduction. 1. Large oil-free screw compressor, Emeraude ALE series

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Advanced Pump Control for Irrigation Applications

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

Oil-injected rotary screw compressors GA (VSD + )

Optimization of Air compressor Motor speed for Reducing Power Consumption

Test Apparatus for Performance Evaluation of Compressed Air End-Use Applications

/ /

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

THE DELIVERY OF GAS SUPPLY

CHAPTER 3 : AIR COMPRESSOR

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 1 Compressors)

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

WORKHOLDING APPLICATION BOOKLET

ENERGY CONSERVATION IN PNEUMATIC SYSTEMS. Solutions That Save

Series 58 SAFETY VALVES 312

High Pressure Compressed Air and Gas Solutions

Vibration and Pulsation Analysis and Solutions

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

ON-SITE INDUSTRIAL GASES. Nitrogen & Oxygen Generators

REDUCING EMISSIONS WHEN TAKING COMPRESSORS OFF-LINE

Project Title: Pneumatic Exercise Machine

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

Process Control Loops

S-CO 2 Brayton Recompression Loop Design and Control

The table below shows the current operating parameters of the system.

Unit 24: Applications of Pneumatics and Hydraulics

Getting the Most for Your Money

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

Hydro Plant Risk Assessment Guide

CASE STUDY. Compressed Air Control System. Industry. Application. Background. Challenge. Results. Automotive Assembly

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

Reconfiguring mining compressed air networks for cost savings CHAPTER 4

The RCM Analyst - Beyond RCM

Industrial Compressor

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

COMPRESSORS AND COMPRESSED AIR SYSTEMS

Air Compressor Control System for Energy Saving in Manufacturing Plant

Understanding safety life cycles

Technical Information

Digester Processes. 1. Raw Sludge Pumping System

Single- or Two-Stage Compression

The Future of Hydraulic Control in Water-Systems

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

Benefits of Detailed Compressor Modeling in Optimizing Production from Gas-Lifted Fields. Manickam S. Nadar Greg Stephenson

THE BAKER REPORT HOW FINDINGS HAVE BEEN USED BY JOHNSON MATTHEY TO REVIEW THEIR MANUFACTURING OPERATIONS

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Reliability. Sistem Perawatan TIP FTP UB 1 -

SRL SEries. Oil Free Scroll Air Compressors hp kw

SEMEM SQA Unit Code HWAW 04 Carrying out maintenance activities on fluid power equipment

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN

Good things come in threes

Hydraulic and Economic Analysis of Real Time Control

OWNER S TECHNICAL MANUAL

MoveRoll Conveyor Operating and Maintenance Manual

Hermetic Compressor Manifold Analysis With the Use of the Finite Element Method

Nitrogen generation for modified atmospheric packaging

Pixel Thermographics Ltd. Compressed Air Leak Detection Survey SAMPLE REPORT. Pixel Thermographics Ltd

TECHNICAL INFORMATION

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

THE GUIDE TO MEMBRANE NITROGEN GENERATORS

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

ejector solutions Flare Gas Recovery & Zero Flare Solutions

Simplicity in VRU by using a Beam Gas Compressor

Air Amplifiers & SYSTEMS

Transcription:

TEXTILES ENERGY EFFICIENCY GUIDANCE NOTE 01 COMPRESSED AIR Compressed air often accounts for more than 10% of textile companies annual electricity use. It is referred to as the forgotten utility, as the true cost of generating compressed air is often not realised. Compressed air systems are usually only between 10% - 15% efficient. As a rule of thumb, for every one unit of compressed work output, eight units of energy input are required at the air compressor. As a result, it is important to design and install the system correctly from the outset. Given the inefficient way these systems use energy, small reductions in compressed air use can often result in large energy savings. This best practice guidance note provides some simple tips and real-world examples of how to design and use compressed air systems more efficiently within textiles plants. 1

There are two discrete steps which should be taken to realise the full energy saving potential of your compressed air system; 1. Are you using compressed air efficiently? The first step is to analyse your compressed air use. Often compressed air demand savings provide the greatest benefit with the lowest implementation costs. Because generating compressed air is such an inefficient process, small reductions in compressed air use will result in large energy savings. 2. Is your supply system optimised for your compressed air use? Once your compressed air demand side has been addressed and all initiatives implemented, you can look at the compressed air supply side, to ensure that your compressed air system is set up optimally to meet your plants demand. 1. Eliminate unnecessary compressed air use Unnecessary compressed air use can lead to higher demands and put strain on the network and supply of your compressed air system, causing follow-on inefficiencies in the system. If your facility s supply system is struggling to cope, rather than purchasing a new air compressor, you should investigate the demand side of the system before making any upgrades. Implementing compressed air demand savings will often only be a fraction of the cost of a new air compressor and will provide the additional benefit of reduced operating costs for your plant. Compressed Air Misuse As the true cost of it is often hidden, compressed air is frequently used as an easy means of solving a problem. Although the use of compressed air often has a small capital cost, the ongoing energy costs are much higher. The use of compressed air for product transportation, tank aeration, cooling and blow-down is not considered best practice and alternatives should be investigated. If the use of compressed air is deemed necessary, it should be done efficiently through the use of high efficiency nozzles and air knifes. As a rule of thumb these devices will often use half the amount of compressed air to accomplish the same task. Pressure Regulation All compressed air uses should be regulated down to the lowest possible working pressure. Reducing the operating pressure of compressed air devices reduces their compressed air use. Because many devices already have pressure regulators, optimising the pressure set points can often be done easily and with little cost. Pressure regulator adjustments save $9,056 per year A large manufacturing company had a number of pneumatic cylinders which were used in their processes. These cylinders were double acting, with compressed air used on both the out and in stroke. A high pressure was required to move product on the out stroke; however the return stroke did not require any great speed or force so the pressure could be greatly reduced. The cylinders already had return stroke pressure regulators; simply by optimising these, the site was able to save $9,056 per annum in energy costs. 2

Compressed air leaks Compressed air leaks commonly account for between 20% and 50% of a textiles sites total compressed air use. Repairing compressed air leaks often has a very short payback period and can serve as part of a preventive maintenance strategy, as badly leaking equipment may cease to function correctly. Textiles company identifies 31% of their compressed air use is due to leaks, costing $11,798 per year A North Island textiles company which has a large compressed air network historically spent very little effort on compressed air leak repair. The site identified that compressed air may be costing them more than necessary and as a result commissioned an ultrasonic air leak survey. The survey identified a total air leak rate of 2.76m3/min. This equated to 31% of the site s total compressed air use. Upon repairing all the compressed air leaks identified, the site would save $11,798 per year. Machine isolation If possible, when individual machines or parts of the plant are not in operation they should be isolated from the compressed air network. Normally this can easily be accomplished through the use of manual ball valves that are installed to isolate machines from the compressed air network when they are being worked on. 90% of compressed air leaks occur at the end use rather than on the supply network. Even with a rigorous compressed air leak prevention regime, it is impossible to completely eliminate all of a site s leaks. Isolating equipment will limit this air leak rate when this equipment is not in use. Manual machine isolation saves $3,842 per annum A New Zealand textiles company contained a number of knitting machines, each with a manual ball valve allowing them to be isolated from the compressed air network. Due to the large amount of pneumatic devices on the knitting machines and their complexity, staying on top of compressed air leaks was proving to be difficult. As each machine on average only operated 70% of the time, the company was able to isolate the knitting machines when they weren t in use, significantly reducing the effect of the compressed air leaks. A compressed air leak rate of 10% or below is considered best practice. Smaller sites should carry out routine audible air leak checks, while large sites may want to consider conducting ultrasonic leak surveys annually. Simply by ensuring that idle machines were isolated from the compressed air network, the company reduced their energy losses due to air leaks by $3,842 per annum. 3

2. Optimise your supply system Once all of your demand based compressed air initiatives have been implemented, you can optimise your supply side to meet your site s new demand. Although significant savings can be made through the acquisition of new technologies such as VSD (variable speed drive) / variable output air compressors, large energy savings can also be achieved by optimising your current compressed air technology often at very little cost. Compressor Room Operating Temperature In textiles plants, air compressors are often installed in plant service areas along with other services such as boilers, pumps and chillers. While keeping all of the plant services in one location may seem like a good idea, the energy input into plant service rooms generates a lot of heat. The higher the intake temperature, the less efficiently an air compressor will operate. As a rule of thumb, for every 3 C above ambient, the air compressor efficiency drops by 1%. It is not uncommon for compressor rooms to operate over 10 C above ambient temperature. This means that the air compressor efficiency will drop by more than 3%. Reducing the intake temperature of an air compressor is often easy, either by adding more ventilation into the compressor room, or by ducting the air compressor s intake air from outside. Compressor Supply Pressure Normally, compressed air devices are designed to operate at 6.0 bar(g). To ensure that the entire plant receives a pressure of 6.0 bar(g), an air compressor pressure set point of 6.5 bar(g) is recommended. This allows a total pressure drop of 0.5 bar over the dryer, filters and distribution. As a rule of thumb, for every 1 bar overpressure, the air compressor efficiency drops by 7%. It is common for facilities to have a supply pressure of between 7.0 bar(g) and 8.0 bar(g), resulting in an air compressor efficiency penalty of between 3.5% and 10.5%. Over-pressurisation can also result in increased air use through unregulated air users and compressed air leaks. If there are some small air users with specific compressed air pressure requirements, consider installing high pressure boosters or another compressed air system. Pneumatic pressure boosters save $5,464 per annum and improve machine reliability An Auckland manufacturing company had a compressed air system with a single pressure set point. Their system was operating at 8.0 bar(g) to ensure that there was an adequate pressure for their printing machines to operate. As these printing machines only required pressure and did not use much compressed air, pneumatic boosters were able to be used to boost the pressure of the air being supplied to the machines, allowing the system pressure to be dropped to 6.5 bar(g). Not only did the site improve its compressed air generation efficiency, the printing machines operated more reliably as they were constantly being held above their 8.0 bar(g) pressure requirement. This initiative saved the company $5,464 per annum. 4

Non-production energy use Many sites do not operate 24 hours per day, 7 days per week, yet their compressed air systems can operate continuously due to small demands which require compressed air when major plant is not in operation. Pressurising the entire compressed air network by running a large air compressor outside of production hours is not an efficient way of meeting this compressed air requirement. Instead, a smaller backup air compressor based where the air is required should be used with a non-return valve so that the compressor does not try to pressurise the entire network. This backup air compressor can be set at a lower pressure set point than the main air compressor so that it will start automatically when the main compressor shuts down. 2.2kW air compressor saves $2,633 per year on energy alone A South Island plant operates 24 hours per day, 5 days per week. Over weekends the plant leaves their compressed air system in operation so that one small machine can operate outside of production hours. Instead of operating the entire network, a small 2.2kW air compressor was purchased and installed. This air compressor saved $2,633 per annum on electricity as well as providing significant maintenance savings. Compressor capacity control There are many forms of compressor capacity control that vary in efficiency based on the type of air compressor and their turndown rate. Generally speaking, for rotary screw air compressors (which are the most common form of industrial compressor), inlet modulation is the least efficient form of control followed by load / unload control, with VSD and variable capacity being the most efficient. Compressed air audit finds $57,816 per annum energy saving through compressor replacement A company was operating a single compressed air network with a 160kW load/unload rotary screw air compressor meeting the plant s compressed air requirements. The air compressor was aging and its efficiency was dropping. Upon conducting a compressed air audit, it was discovered that the air compressor was no longer unloading correctly and was using significant amounts of energy when it was unload. Instead of spending money on repairing the aging compressor, it was recommended that a new VSD compressor be installed and the old compressor kept as a backup. This saved the company $57,816 per annum in electricity. Purchasing a new, efficient compressor to replace a working model is often not justified, due to the high upfront capital cost. However, when purchasing a new air compressor the most efficient model available should be selected to reduce a plant s ongoing costs. 5

Textiles Energy Efficiency Programme This information has been made available thanks to Textiles NZ and the Textile Care Federation working with EECA to deliver energy efficiency to New Zealand textiles companies. Textiles NZ membership comes from four contributing sectors: textiles, carpet, footwear and apparel. Textiles NZ works with companies to build a sustainable industry that can successfully compete in the international marketplace. Multiple compressor control Efficient multiple compressor control is essential on sites that have more than one air compressor. It is important to set the system up so that it supplies air as efficiently as possible over the required range of operating conditions. To ensure this, the most efficient air compressor at turndown, such as a VSD air compressor, should be set as the trim compressor. If the site has many air compressors and a wide compressed air demand range, a PLC air compressor controller should be considered. These units have the ability to manage multiple air compressors and ensure that the most efficient combination of air compressors is run to meet any particular demand. Textiles New Zealand P O Box 1785 Wellington 6140 New Zealand Phone: +64 27 295 0928 Email: elizabeth@textilesnz.org.nz 6