MANUFACTURING PROCEDURE SPECIFICATION INSPECTION TEST PLAN

Similar documents
Magnetic Particle Procedure TABLE OF CONTENTS

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

Employer s Unit of Competence Magnetic particle testing of materials, products and plant

Standard Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation 1

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

BVM CORPORATION TYPE AAX TONG 55,000 FT/LBS. TORQUE Part number: Serial Number:

Liquid Penetrant Procedures TABLE OF CONTENTS

Technical Standard. API6D Ball & Plug Valve. Inspection & Test Procedure

QUALITY ASSURANCE SPECIFICATION NONDESTRUCTIVE EXAMINATION PAGE 1 OF 7

INSPECTION OF RECOVERY BOILERS

REVISIONS. App Thom. App PC. App Sud PB 2012/01/18 PB 2012/11/22 KLR 2015/06/17

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Annex G (normative) Requirements for Nondestructive Examination

Guided Wave Testing (GWT)

PIP PNE00012 Piping Examination and Leak Test Guide

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

HYDROSTATIC LEAK TEST PROCEDURE

Telefon (+45) Telefax (+45)

Regulated Oil and Gas Companies under National Energy Board Jurisdiction

Subpart E. Pressure Testing

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

SECTION PRESSURE TESTING OF PIPING

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

Installation, Operation and Maintenance Instructions

VALVE MANUFACTURERS ASSOCIATION API 622 API 624

A guide to Part 10 of the

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

DGZfP-Proceedings BB 90-CD Lecture 4 EWGAE 2004

Ontario ENGINEERING STANDARD SPECIFICATION 1.0 PURPOSE

Ground Release Shackle

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

High Pressure Iron (HPI) Recertification Guidelines & Procedures

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

This document is a preview generated by EVS

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Outline for Safety Performance Supervisory Inspection of Boiler and Pressure Vessel Products

Eaton Filtration, LLC

WIKA INSTRUMENT CORPORATION

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

HEALTH AND SAFETY PROGRAM 201 HOT TAP PERMIT/FILLET WELD REPAIRS

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

Life Extension of Mobile Offshore Units

SAFEHOLD RPL SERIES. Installation, Operation and Maintenance Instructions MJ-2304A

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP:

Company Profile.. About Sammi Machinery

CURI Pierside Stainless Diesel Tank

Guide for Evaluating Your Hose Assembly Supplier

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Pipeline Systems PIP PLSC0019 Specification for Pressure Testing HDPE Plastic Pipeline Systems

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

TECH TIPS: ROPE DEFECTS

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General...

Wire ropes condition monitoring: conception and embodiment

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions

DVS Technical Codes an Bulletins

Accreditation for In-Service Inspection of Pressure Systems/Equipment

Limited quantities of compressed gases.

1 Exam Prep. Tabs and Highlights

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

Instruction Manual Contact Pressure Vacuum Gauge

LIQUID PENETRANT EXAMINATION OF NON-POROUS MATERIALS

Survey of Underwater NDT Technologies for Offshore Assets

CONTROL OF HAZARDOUS ENERGY

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Use this key to determine which sections of this Product Manual apply to your job.

Part 192 Subparts J & K. Testing & Uprating

Piped Air SCBA Refilling System Standard

The purpose of this task is to prevent damage from occurring to the pipe or it s coating when backfilling an exposed pipeline.

Paper #: POWER

Operating Procedures for 10 through 24 GripTight MAX High Pressure Test Plug

CORESTA RECOMMENDED METHOD N 6

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180:

Biological Safety Cabinet Guidelines

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

A fresh initiative on the use of daylight magnetic particle inspection for the inspection of underwater steel structures

Guidelines for Certification - Pressure Equipment Inspectors. DOCUMENT No PRO-CER-08

DeZURIK. KSV Knife Gate Valve. Safety Manual

WHEATLEY Series 822/820 Swing Check Valve

i) Filtration machine, measuring equipment and other related machinery

API-510 PRESSURE VESSEL INSPECTOR

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

Installation, Operation and Maintenance Instructions

NONDESTRUCTIVE INSPECTION OF HULL WELDS

THE PROCESS OF JOINT INTEGRITY

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Standard Test Method for Ammonia Colorimetric Leak Testing 1

General Accreditation Guidance. User checks and maintenance of laboratory balances

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

Liquefied gas cargo tanks and process pressure vessels

Transcription:

TEST PLAN 1.0 SCOPE The purpose of this work instruction is to establish and maintain documented procedure to ensure that the magnetic particle inspection of bend body over extrados and intrados is carried out to get desired quality of hot pulled induction bend. 2.0 APPLICABLE CODE & STANDARDS API 5L 45th Edition 2012 Specification for Line Pipe ISO 15590-1:2009 Petroleum and natural gas industries Induction bends, fittings and flanges for pipeline transportation systems Part 1: Induction bends MSS-SP-75-2008 Specification for high test, wrought, butt welding fitting. ASME B 16.49:2007 Factory-Made, Wrought Steel, Butt welding Induction Bends for Transportation and Distribution Systems ISO 9712 Qualification and certification of personnel 3.0 RESPONSIBILITY Personnel performing Magnetic Particle Examination shall be responsible for interpretation & evaluation of indications during the examination & preparation of examination reports. An ASNT LEVEL III shall be responsible for overall supervision. 4.0 PERSONNEL QUALIFICATION NDT personnel shall be qualified as per WCL written practice & Vision examination shall be as per applicable SNT TC 1A. 1) NDT L-III shall be responsible for overall supervision. 2) NDT L-II personnel shall set up the equipment; perform tests and reports the results. 5.0 STAGE OF EXAMINATION The Magnetic Particle Examination shall be carried out on bend after beveling. 6.0 METHOD OF EXAMINATION Magnetic Particle Examination shall be carried out using Continuous method, YOKE -type 7.0 TECHNIQUE PAGE 1

TEST PLAN Wet - Non-Fluorescent/ Fluorescent 8.0 APPARATUS YOKE type, make - MAGNAFLUX /K-ELECTRONICS. 9.0 TYPE OF : Red/Black/Gray magnetic powder for Wet MPI. 10.0 SYSTEM PERFORMANCE / SENSITIVITY CHECK 11.0 MAGNETIC FIELD INDICATOR (PIE FIELD INDICATOR) The Magnetic field indicator shall be used to verify the presence and approximate Direction of magnetic field. A suitable field strength is indicated when a clearly defined lines of magnetic particles forms across the copper face of the indicator when the magnetic particles are applied simultaneously with the magnetizing force. PAGE 2

TEST PLAN 12.0 LIFTING CAPACITY OF YOKE The lifting capacity of yoke shall be checked as mentioned below. In AC current, an electromagnetic yoke shall have a lifting power of 10 lb. (4.5 Kg.) at maximum pole spacing that will be used. 13.0 SYSTEM PERFORMANCE / SENSITIVITY CHECK FREQUENCY The sensitivity shall be performed at: The beginning of each normal inspection shift, Every four hours of the running system. When there is malfunctioning of the inspection equipment found. The equipment shall be recalibrated if any of the parameters which were used during the initial calibration are changed. End of the production run. End of inspection Before any planned shutdown of the magnetic equipment during production and every time the running of the system gives raise to doubt about in its efficiency. 14.0 EXAMINATION AREA Light Intensity for examination PAGE 3

TEST PLAN Magnetic indications found using non fluorescent magnetic particles are examined under visible light. The intensity of visible light at the surface of the part Undergoing examination should be a minimum of 100 foot candles (1000 lux). The intensity of black (ultraviolet) light at the surface of the part undergoing examination should be a minimum of 1000 μw cm². Test Surface Preparation: The examined surface shall be free of scale, dust, oil & dirt. 15.0 DETERMINING BATH CONCENTRATION A bath concentration is determined by measuring its settling volume through the use of a pear-shaped centrifuge tube. Take a 100 ml portion of the non Fluorescent suspension from the nozzle and allow it to settle for minimum 30 minutes with water based suspension before reading. The recommended settling volume is 1.2 to 2.4 ml per 100 ml of Suspension as per ASME Sec. V, Article 7. For fluorescent particles- The required settling volume is from 0.1 to 0.4 ml in a 100 ml bath sample Concentration check shall be performed at the start of each shift. 16.0 EXAMINATION PROCEDURE PAGE 4

TEST PLAN Place the pie field indicator between the legs of the yoke on test surface and apply the bath spray to confirm the magnetic field direction and strength of magnetic field. The examination shall be carried out in two direction way with simultaneous application of bath spray to test the bend body over an arc of 900 both sides from extrados of bend. 17.0 INTERPRETATION OF INDICATION All indications formed by magnetic particle examination are the result of magnetic leak fields. Indications may be relevant (16.1), non-relevant (16.2) or false indication (16.3). Relevant Indications Relevant indications are produced by leakage fields, which are the result of discontinuities. Relevant indications required evaluation with regard to the acceptance standards. Non relevant Indications Non relevant indications can occurred singly or in patterns as a result of leakage field created by conditions that require no evaluation such as changes in section, inherent material properties (like the edge of a bimetallic weld), magnetic writing etc. False Indication - False indications are not the result of magnetic forces, those may be particles held mechanically or by gravity in shallow depressions or particles held by rust, scale on the surface 19.0 DEMAGNETIZATION Measurement shall be made on test surface of the bend. The residual magnetism at the test surface shall not exceed 30 gauss & no single reading shall exceed 35 gauss. The residual magnetism is measured by using calibrated Gauss Meter/Hall effect gauss meter. If residual magnetism found more specified above, demagnetization shall be carried out. After demagnetization the residual magnetization shall be measured again. 19.0 ACCEPTANCE CRITERIA Laminar imperfections 6,4 mm (0.25 in) in the circumferential direction shall be classified as defects If any relevant linear indications are found (i.e. crack, Lamination etc.) during MPI, the bend end shall be re beveled, and again the re beveled end shall be retested 20.0 DISPOSITION OF BEND CONTAINING DEFECTS The section of bend containing defect shall be cut off with in the applicable for length. If bend length is not in length tolerance, bend shall be rejected /degraded. PAGE 5

TEST PLAN 21.0 DOCUMENTATION Test results shall be recorded on Bendco Form: 22.0 SAFETY PRECAUTION DO S Only authorized personal is authorized to operate the machine. Precaution should be taken during pipe movement to ensure that nobody is standing in front of pipe. Always use spray gun/bottle for spraying wet particle on the pipe. While using fluorescent method, check UV filter frequently for any damage. Maintain good housekeeping. Use recommended PPE s. DON TS Do not cross the barricading. Do not touch the pipe with bare hands. PAGE 6