SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Similar documents
SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

MODEL RP050BMST RESPIRATORY PROTECTOR MANUAL

MODEL RP200C(_)-S1 RESPIRATORY PROTECTOR MANUAL

MODEL RP050BMST-S1 RESPIRATORY PROTECTOR MANUAL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

INSTRUCTION MANUAL & PARTS

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

BREATHING AIR PURIFIER

RAM 9025-XP Operation Manual

AIRLINE-SERIES HELMET AIR FILTER

PRODUCT OPERATING MANUAL

B-Series. breathing air systems flow capacity: scfm

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

PERSONAL AIR BREATHING UNIT

Technical Information

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

Product Information News

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Tsunami Breathable Air System

Advantage 4000 Abrasi-Blast Respirator

Operating Manual. Model BAC-30RT30/BAC-30DC

MODEL CALIBRATION GAS DELIVERY SYSTEM

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Instruction Manual Updated 7/26/2011 Ver. 2.2

TECHNICAL INFORMATION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

A. Evaluation of the written program

Yoke Block Instruction Manual

A Pocket Guide to Air-Line Systems

OPERATION MANUAL NTF-15

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

accidents which arise due to non-observance of these instructions and the safety information herein.

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Important: Keep these instructions for reference.

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

MMR Air Mask With. with Quick-Connect Hose

RAM 4021 Operation Manual

photo coming soon Product Family Respiratory Replacement Parts Canada (English) Page 1 of 17 Product Numbers & Ordering Information

CSA Sample Draw Aspirator Adapter Operator s Manual

A Pocket Guide to Air-Line Systems. Visit: Or for Sales & Service.

OPERATION MANUAL NTF-60 Plus

TECHNICAL INFORMATION

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

GREIG FILTERS, INC. OPERATION MANUAL

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Air Quality Test Kits Models: LP/HP-A4K and LP/HP-A445K

Yoke Block Instruction Manual

photo coming soon Product Family Respiratory Replacement Parts Corporate - English Page 1 of 23 Product Numbers & Ordering Information

Interface Devices, Inc. Hydraulic Mini Mule

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Protocol Switchover Station

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

200 PSI FAST-FILL AIR SOURCE KIT

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

RAM 4021-DPX Operation Manual

RAM Operation Manual

Model PSI Compressor with 3-Gallon Air Tank 12VDC

COMPRESSOR MANUAL. (888)

Breathable Compressed Air

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

JORDAIR/BAUER Service Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

Niltox Breathing Air Purifier Range

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

200 PSI HIGH-FLOW AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Advanced Fluid Handling Cart Owner s Manual

Model Air Caddy Orig TABLE OF CONTENTS

100C Air Compressor Kit

IMPORTANT SAFETY INSTRUCTIONS

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

SOTR Special Operations Tactical Respirator

1 DRIVE INDUSTRIAL IMPACT WRENCH

PRESSURISED PAINT CONTAINER

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Operating Manual. Appa. Models LP/HP-A4K & LP/HP-A445K Air Quality Test Kits Manual No. AIRTST01 (Rev 7 October 2008)

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

CF-SERIES HIGH FLOW REGULATORS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Transcription:

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05

GENERAL OPERATION MANUAL WARNING: The MST Breathing Air Panel Model BA600AMST-S1: 1) WILL NOT remove Carbon Monoxide. 2) SHOULD NOT be used when the air entering the filtering system is oxygen deficient. The MST Breathing Air Panel will not increase the oxygen content of the air. 3) SHOULD NOT be used in an Immediately Dangerous to Life and Health Atmosphere (IDLH) unless it is used in conjunction with a Back-Up Escape system or a supplied air Self- Contained Breathing Apparatus (SCBA), where applicable. 4) SHOULD NOT have air inlet pressure greater than 150 PSIG static (10.4bar). Personal injury could result. 5) SHOULD NOT have air outlet pressure that exceeds Manufacturers' Respirator/Hose Assembly pressure requirements. Personal injury could result. 6) CARBON MONOXIDE MONITOR will alarm if Carbon Monoxide levels exceed requirement for Grade D Breathing Air set forth by OSHA/CSA. If alarm should sound, remove respirator or activate SCBA and immediately move to safe breathable atmosphere. Have the proper qualified personnel examine the equipment and make the appropriate corrections before using again. The MST Breathing Air Panel is a Four Stage Filtration System designed to remove or reduce select contaminates found in compressed air lines. The Breathing Air Panel can be connected directly to shop air from a standard compressed air source to help provide breathing quality air to face masks, helmets, hoods and other supplied air breathing apparatus. 2

GENERAL FILTER SYSTEM DESCRIPTION (Refer to Figure No.1) Air entering the MST Breathing Air Panel at the inlet (A) is usually contaminated with oil, water, dirt, rust, scale and gaseous Hydrocarbons. As the air passes through the First Stage (B), particulate and liquid contaminates will be trapped-coalesced out (0.7 micron max solids and liquids down to 2.0 microns at an efficiency rating of 95%). The liquids are trapped and expelled through the Automatic Float Drain (C). The Differential Pressure Gauge (DPG) at (D) will indicate when element requires changing. The Second Stage (E) traps and retains particulate matter down to 0.3 microns. As air enters the Third Stage (F), liquid contaminates are coalesced down to 0.75 microns with an efficiency rating of 99.97% (meets Underwriters Laboratories Specification UL 586 for High Efficiency, Particulate, Air Filter Units). The liquids are trapped and expelled through the Automatic Float Drain (G). The DPG at (H) will indicate when element requires changing. The Fourth Stage (I) contains odor absorbing activated charcoal which collects various Hydrocarbons (such as oil fumes, benzene, etc.). Any liquids (should not be any) are trapped and expelled through Automatic Float Drain at (J). The DPG at (K) will indicate when all filters require replacement. The air is then passed through the Air Pressure Regulator (L), which is used to adjust the air pressure going to the respiratory system. A sample of the filtered air is taken at (M) and passed through the Carbon Monoxide Monitor (N). The Carbon Monoxide Monitor continuously checks the carbon monoxide levels per OSHA/CSA requirements and digitally displays the amount present in PPM (Parts Per Million). An audible and visual alarm will alert operators if levels of carbon monoxide exceed OSHA/CSA requirements. FIGURE NO.1 3

GENERAL INSTRUCTIONS The MST BA600AMST-S1 Breathing Air Panel, a compressed air purifier, when used in accordance with the following instructions, will remove or reduce selected contaminants from compressed air lines. WARNING: The MST Breathing Air Panel BA600AMST-S1 should not be used when the air entering the filter is oxygen deficient (air with a low oxygen content). The MST Breathing Air Panel will not increase the oxygen content of oxygen deficient air. MST, Inc. strongly recommends that a complete safety program be initiated to ensure that the respiratory air is in compliance with all OSHA standards and other applicable laws regulating the use of supplied air respiratory systems. MST, Inc. recommends that the air quality be tested upon installation and periodically re-tested to ensure that the minimum requirements for breathing air are maintained. WARNING: The MST Breathing Air Panel BA600AMST-S1 will not remove Carbon Monoxide. The Carbon Monoxide Monitor in the Breathing Air Panel Model BA600AMST-S1 is Certified Intrinsically Safe for Class 1, Div. I, Groups A, B, C & D Hazardous Locations when utilizing the two 9 volt batteries to power monitor. When the monitor is powered by the 120 VAC Adapter, the Intrinsically Safe Certification is void. Refer to the MST Monitor Model 5700 Information Manual for charging, calibration, and operating instructions. MST, Inc. will not assume any liability for accidents or personal injury resulting from the improper use of this equipment. Service on this equipment should only be performed by qualified personnel. This system is to be used only by trained qualified personnel in accordance with a respirator program as outlined in OSHA Regulation 29 CFR 1910.134(b). The air supply entering The MST Breathing Air Panel must meet the following criteria to ensure maximum efficiency of the MST filter system: 1) Temperature range should be between 35-150 o F (2-65 o C). Conditioning equipment may be necessary, prior to the filter, to achieve this temperature range. WARNING: Maximum pressure supplied to this unit IS NOT to exceed 150 PSIG. Personal injury could result. The Regulator 80432 is used to set the air pressure supplied to the breathing air system and to maintain the correct air exchange in the operators respirators. Consult instructions on your particular breathing mask or hood for pressure requirements per NIOSH. 4

WARNING: DO NOT Exceed mask and hose assembly manufacturer's requirements for outlet pressure. Personal injury could result. The filter cartridges used in the Breathing Air Panel Model BA600AMST-S1 have an average life expectancy of (6) six months, (depending on the quality of the air in your compressed air lines) under normal conditions. If liquid is being expelled out from the Fourth Stage Automatic Float Drain, MST, Inc. recommends changing all (3) filter cartridges. * WARNING: If the Monitor s alarm should sound, remove mask or hood immediately and move to a safe breathable atmosphere. Have a proper qualified personnel examine the equipment and make the appropriate corrections before using again. ** The Carbon Monoxide Alarm will sound to alert the operator that a problem has developed. The Monitor Alarm will sound due to one or more of the following conditions: A) Carbon Monoxide levels exceeding a pre-determined alarm set level is passing through the Breathing Air Panel. The Breathing Air Panel does not remove or reduce the Carbon Monoxide content in the compressed air. Examine the air compressor, the air compressor intake air quality, and the complete system. Have the proper qualified personnel make the appropriate corrections before using again. B) Monitor out of Calibration. Calibrate Carbon Monoxide Monitor as outlined in the MST Monitor Model 5700 Information Manual. C) The monitor s carbon monoxide sensor may be bad. See the MST Monitor Model 5700 manual for further maintenance on monitor. SERVICE INSTRUCTIONS (Refer to Figure No.2) WARNING: Always turn off air supply and bleed air pressure before disassembling unit or SERIOUS INJURY COULD RESULT. 5

To replace all or individual filter cartridges in the Breathing Air Panel Model BA600AMST-S1, follow these steps: 1. FIRST STAGE ELEMENT REPLACEMENT Element change is required when the Differential Pressure Gauge indicates a 6-10 PSID, 12 PSID max. A) First unscrew Bowl Assembly (1). A strap wrench may be required to break bowl, O-ring/manifold seal. Clean bowl ass y in mild soap and water and blow dry with low pressure air. B) Remove Coalescing Element (2) by unscrewing End Cap Retaining Nut (3). C) Inspect the Filter Manifold (4) for dirt/contaminates and clean as required. Inspect O-ring (5) for cuts etc. and replace if required. Clean and apply light film of petroleum jell on O-ring before re-installing. D) Install new Coalescing Element and tighten End Cap Retaining Nut. Be sure Element is seated squarely on Manifold s boss and End Cap. E) Apply light film of petroleum jell on Bowl s beveled edge and threads to provide good seal. HAND TIGHTEN ONLY to Manifold. F) Dispose of used Coalescing Element according to local, state and federal regulations. 2. PREFILTER SECOND/THIRD DUAL STAGE ELEMENT REPLACEMENT Prefilter Dual Stage Element change is required when the Differential Pressure Gauge indicates an 8-10 PSID. A) Replace the Prefilter Dual Stage Element (6) using the above First Stage Element replacement instructions. B) Dispose of used Prefilter Dual Stage Element according to local, state and federal regulations. 3. FOURTH STAGE ADSORBER ELEMENT REPLACEMENT The Adsorber Element change is required when the Differential Pressure Gauge indicates ANY PRESSURE DROP, or if any odor is detected by operator. NOTE: If any liquids are being expelled out of the Fourth Stage Auto Drain, replace All 3 Elements. A) Replace the Adsorber Element (7) using the above First Stage Element replacement instructions. B) Dispose of used Adsorber Element according to local, state and federal regulations. 6

4. FINAL CHECK A) Pressurize system and check for leaks. B) Flush system with compressed air for five (5) minutes. C) Calibrate Carbon Monoxide Monitor as outlined in MST Monitor Model 5700 Information Manuals. FIGURE NO.2 7

AIR SAMPLE TO MONITOR ADJUSTMENT WARNING : SERIOUS INJURY could result if the AIR SAMPLE METERING VALVE is not properly adjusted. Proper sample air flow to CO monitor is required for monitor to give correct CO level readout. AIR SAMPLE FLOWMETER ADJUSTMENT A) After pressurizing system and respirators air flow is set, adjust air sample regulator to 10-20 PSI pressure. B) Turn the flowmeter s adjustment knob counter-clockwise slowly until the black floating ball is within the GREEN BOXED AREA etched on flowmeter body. CAUTION: if adjustment knob is turned too quickly, the black floating ball may get stuck to the top of flowmeter scale. Damage to Monitor s Sensor may occur due to extremely high air flow to sensor, (not covered by sensor warranty). 8

RECORD KEEPING Record all periodical air quality checks, filter cartridge change intervals and any other service performed on the MST Breathing Air Panel. MST INC. SHALL NOT BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE, (DIRECT OR CONSEQUENTIAL), ARISING OUT OF THE USE OF OR THE INABILITY TO USE THIS PRODUCT, BEYOND THE REPLACEMENT Of DEFECTIVE MATERIALS OR WORKMANSHIP. USER OF SUPPLIED AIR RESPIRATORS SHOULD EVALUATE THEIR OWN PARTICULAR APPLICATION AND PERFORM THEIR OWN TESTS FOR AIR QUALITY TO DETERMINE THE SUITABILITY FOR USE OF THIS PRODUCT. For further information, or questions about service or maintenance care of this unit, contact your local distributor or MST, Inc. at (800) 542-6646. 9

MST, INC. SERVICE RECORD MODEL BA600AMST-S1 DATE OF SERVICE SERVICE PERFORMED 10

SPECIFICATIONS BREATHING AIR PANEL MODEL BA600AMST-S1 INLET PRESSURE (MAX.) RATED AIR FLOW (MAX.) OPERATING PRESSURE OUTLET PRESSURE RANGE 150 PSIG STATIC (10.4 BAR) 600 SCFM (283.2L/s) 100 PSIG DYNAMIC (6.9 BAR) 0-125 PSIG (0-8.6 BAR) OPERATING TEMP.RANGE 35-150 O F (2-65 O C) OUTSIDE DIMENSIONS 36"L X 36"W X 7"D (915mm X 915 mm X 178 mm) WEIGHT (INCLUDING MONITOR) 87 Lbs (39.5 kg.) REPLACEMENT FILTER ELEMENTS FIRST STAGE ELEMENT 80419 SECOND/THIRD STAGE ELEMENT 80420 FOURTH STAGE ELEMENT 80421 REPLACEMENT FILTER KIT (CONTAINS ALL ELEM ENTS) FB600 11

MODEL BA600AMST-S1 SYSTEM 12

BREATHING AIR PANEL MODEL BA600AMST-S1 PARTS 1) 80425,(1), 2" Ball Valve 17) S638-011, (1), 3/4" x ½" R. Bushing 2) S603-091,(5), BR Nipple 2" x 2 1/2" 18) S623-004, (1), ½" 90 o St. Elbow 3) 80414,(1), Coalescing-600 SCFM 19) S608-003, (2), 1/4" Hex Nipple 4) 80051,(3), Tube Locking Collar 20) S638-008, (1), ½" x 1/4" R. Bushing 5) S710-005,(3), Drain Tube 21) 80091, (1), Pressure Gauge, 0-160 psi 6) 80415,(1), Prefilter-600 SCFM 22) 80533, (1), 1/4" Regulator 7) 80416,(1), Adsorber-600 SCFM 23) 80138, (1), 14" x 1/8" Adapter 8) 80422,(3), Differential Pressure Gauge 24) S623-001, (1), 1/8" x 90 o St. Elbow 9) 80430,(2), Mount Bracket Ass y 25) 80213, (1), Flowmeter 10) 80431,(4), Mount Bracket Bolts 26) 80261, (1), Tube Lock Collar, 90 o 11) 80449,(1), Tee, 2" 27) 80432, (1), 2" Regulator 12) S638-018,(1), 2" x 1" R. Bushing 28) 80076, (1), Pressure Gauge, 0-160 psi 13) S638-012,(1),1" x 3/4" R. Bushing 29) 80189, (1), Mount Board 14) S608-009, (1), 3/4" Hex Nipple 30) 8008403, (1), Remote Alarm 15) 80067, (1), Tee, 3/4" 31) 80247, (1), 110 VAC Adapter 16) 80427, (1), 3/4" x 150 PSI, PRV 32) 80339, (1), Monitor Bracket 33) 80127, (1), MST CO Monitor 13