Electrically Held Lighting Contactors.1 Product Description....................................... Application Description.................................... Standards and Certifications................................ Additional Reference...................................... V10-T- V10-T- V10-T- V10-T- Mechanically Held Lighting Contactor Catalog Number Selection.................................. Enclosures.............................................. Cover Control............................................ Operation............................................... Accessories............................................. Wiring Diagrams......................................... V10-T-3 V10-T-3 V10-T- V10-T-8 V10-T-1 V10-T-13 Type 1 Electrically Held Lighting Contactors Type 1 Non-Combination Lighting Contactors Volume 10 Enclosed Control CA0810001E November 01 www.eaton.com V10-T-1
.1 Lighting Contactors Contents Description Catalog Number Selection................ Enclosures............................ Cover Control.......................... Product Selection.................... Operation Non-Combination Contactors............ Combination Contactors............... Accessories........................... Wiring Diagrams....................... Page V10-T-3 V10-T-3 V10-T- V10-T-5 V10-T-8 V10-T-10 V10-T-1 V10-T-13 Product Description Eaton s lighting contactors are designed to provide a safe, convenient means for local or remote switching of tungsten (incandescent filament) or ballast (fluorescent and mercury arc) lamp loads. They are also suitable for other loads such as low pressure and high pressure sodium lamp loads and other non-motor (resistive) loads. They are not recommended for most sign flashing loads. These lighting contactors are designed to withstand the large initial inrush currents of tungsten lamp loads without contact welding. They are fully rated and do not require derating. Application Description Loads: Ballast Lamps Fluorescent, mercury vapor, metal halide sodium vapor, quartz 600V maximum. Filament Lamps Incandescent, infrared, heating 80V maximum, line to line; 77V maximum line to neutral. Resistance Heating Radiant and convection heating, furnaces and ovens. Standards and Certifications Note: See Tab 17 for additional information on Standards and Certifications that apply to all Enclosed Control products. UL Listed cul Listed ABS Type Approved OSHPD Certified (OSP-0015-10) Additional Reference Accessories...................... V10-T-1 and Tab 15 Cover Control............................. V10-T- Dimensions.............................. Tab 1 Accessories and Modifications............... Tab 15 Technical Data and Specifications............. Tab 17 V10-T- Volume 10 Enclosed Control CA0810001E November 01 www.eaton.com
.1 Catalog Number Selection Enclosed Lighting Contactors Design L = CN35 or A0 lighting contactor C = C30CN lighting contactor Class Page 03 = Non-combination electrically held lighting contactor V10-T-5, V10-T-6 0 = Non-combination ly held/magnetically latched lighting contactor 1 = Combination electrically held lighting contactor fusible disconnect 13 = Combination magnetically latched lighting contactor fusible disconnect 1 = Combination electrically held lighting contactor thermal magnetic circuit breaker 15 = Combination magnetically latched lighting contactor thermal magnetic circuit breaker A = 10A B = 0A C = 30A Enclosures Lighting contactors are available open or mounted in Type 1, 3R,, X, 1 or 7/9 enclosures. Type 1 is for indoor, general purpose for personal protection. Knock-outs are provided in the top and bottom for conduit entry. Type 3R is for outdoor applications and rated for rain, sleet and external ice buildup. Type 3R enclosures have knockouts in the bottom and provisions for a hub in the top. 1 C30CN available in 30A only. For normally closed poles see Tab 15. Ampere Size 1 D = 60A E = 100A F = 00A V10-T-5, V10-T-8 V10-T-10 V10-T-10 V10-T-11 V10-T-11 G = 300A H = 00A J = 600A Enclosure Types 1 = Type 1 General purpose = Type 3R Rainproof 3 = Type Watertight (painted) = Type X Watertight (30-Grade stainless steel) 6 = Type 7/9 Explosion proof 8 = Type 1 Dust-tight 9 = Type X Watertight (316-Grade stainless steel) EC L 1 D 1 A 3 E - X Type and X are for mounting indoor or outdoor and provide protection from splashing water, hosedirected water and windblown dust. Watertight conduit hubs are provided in the top and bottom of Type X enclosures. The standard Type X enclosures are made of 30-Grade stainless steel, providing corrosion protection. 316-Grade stainless steel construction is available as an upgrade option. A = None B = 30A/50V R C = 30A/600V R D = 60A/50V R E = 30A/600V R F = 100A/50V R G = 100A/600V R H = 00A/50V R A = None D = 0A E = 30A Type 1 enclosures are for indoor mounting and protect from dripping liquids, falling dirt and dust. No knockouts or hubs are provided with Type 1 enclosures. Modification Codes (See V10-T- and Tab 15) Disconnect Fuse Clip Ratings J = 00A/600V R K = 00A/50V R L = 00A/600V R M = 600A/50V R N = 600A/600V R P = 800A/600V R T = By description Thermal-Magnetic Breaker Ratings F = 60A G = 100A H = 00A Number of Poles 1,, 3,, 5, 6, 7, 8, 9 = Poles required A = 10 poles B = 1 poles C = 0 poles Combination Devices = Three-pole only A = 10/60 110/50 B = 0/60 0/50 C = 80/60 0/50 D = 600/60 550/50 E = 08/60 G = 550/50 H = 77/60 J = 08 0/60 Coil Voltage K = 0/50 L = 380/50 M = 15/50 P = 1 Vdc Q = Vdc R = 8 Vdc S = 15 Vdc J = 300A K = 00A L = 600A T = /60 U = /50 V = 3/50 W = 8/60 X = 10 10/60 Y = 8/50 Z = By description M = 800A T = By description Type 1, 3R, and 1 enclosures are painted with a polyester urethane powder coat paint meeting UL requirements and the color is ANSI 61 gray. Type 1 enclosures have knockouts for cover controls. All the other types have holes plugged, ready for cover controls. Type 7/9 is also available for explosion proof applications. Please contact the factory for additional details. Volume 10 Enclosed Control CA0810001E November 01 www.eaton.com V10-T-3
.1 Lighting Contactors Cover Control Cover Mounted Pilot Devices Description For Use with Lighting Contactor 1 For use with non-combination units (box sizes 1 ). Add code letter from table below to catalog number for voltage in place of _. Factory Installed Cover Control Type 1, 3R, X and 1 Type 7/9 Type 1 1 Modification Code Suffix Modification Code Suffix 3 For use with Type 1 combination units as well. Selector switch. 5 With three-position selector switch, Mod C0 (two-wire control relay) must be used with magnetically latched contactor (ECL0, ECL13, ECL15). Field Installation Kits Catalog Number Type 3R, X, 1 Combination and Non-Combination 3 Catalog Number ON/OFF pushbuttons Electrical P8 P8 C00GK18 C00T three-wire C30CN; CN35; A0 P8P3 P8P3 C00GK19_ With red RUN/GREEN off lights P8P3P5 P8P3P5 C00GK1A_ ON/OFF Pushbuttons Mechanical P8 P8 C00GK C00T01 three-wire C30CN P8P3 P8P3 C00GK8_ With red RUN/GREEN off lights P8P3P5 P8P3P5 C00GK9_ ON/OFF pushbuttons P8 P8 C00GK5 C00T1 two-wire C30CN; P8P3 P8P3 C00GK5_ With red RUN/GREEN off lights CN35; A0 P8P3P5 P8P3P5 C00GK55_ Start/stop pushbuttons Mechanical P7 P7 C00GK7 C00T00 three-wire C30CN P7P3 P7P3 C00GK7_ With red RUN/GREEN off lights P7P3P5 P7P3P5 C00GK75_ Start/stop pushbuttons P7 P7 C00GK6 C00T13 two-wire C30CN P7P3 P7P3 C00GK6_ With red RUN/GREEN off lights P7P3P5 P7P3P5 C00GK65_ HAND/OFF/AUTO cover control S3 S3 5 C00GK3 C00T1 two-wire C30CN; S3P3 S3P3 5 C00GK3_ With red RUN/GREEN off lights CN35; A0 S3P3P5 S3P3P5 5 C00GK35_ Red RUN pilot light All P3 P3 C00GK_ C00T9_ Green OFF pilot light P5 P5 C00GK1_ C00T10_ Red RUN/green OFF pilot light P3P5 P3P5 C00GK6_ C00T11_ Rating Code Letter Rating Code Letter Rating Code Letter V 60 Hz T 0V 60 Hz B 80V 60 Hz C 10V 60 Hz A 77V 60 Hz H 600V 60 Hz D 08V 60 Hz E 380V 60 Hz L V10-T- Volume 10 Enclosed Control CA0810001E November 01 www.eaton.com
.1 Product Selection Two-Wire and Three-Wire Control Wiring Options Two-Wire Control Standard Class ECC03 Non-Combination Electrically Held Lighting Contactor Two or Three-Wire Control Component Number Type 1 Type 3R Type X Type 7/9 Type 1 Contactor (Open) of Poles Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Continuous Amps 30 ECC03C1_A ECC03C_A ECC03C_A ECC03C6_A ECC03C8_A C30CNE0_0 3 ECC03C1_3A ECC03C_3A ECC03C_3A ECC03C6_3A ECC03C8_3A C30CNE30_0 ECC03C1_A ECC03C_A ECC03C_A ECC03C6_A ECC03C8_A C30CNE0_0 5 ECC03C1_5A ECC03C_5A ECC03C_5A ECC03C6_5A ECC03C8_5A C30CNE50_0 6 ECC03C1_6A ECC03C_6A ECC03C_6A ECC03C6_6A ECC03C8_6A C30CNE60_0 7 ECC03C1_7A ECC03C_7A ECC03C_7A ECC03C6_7A ECC03C8_7A C30CNE70_0 8 ECC03C1_8A ECC03C_8A ECC03C_8A ECC03C6_8A ECC03C8_8A C30CNE80_0 9 ECC03C1_9A ECC03C_9A ECC03C_9A ECC03C6_9A ECC03C8_9A C30CNE90_0 10 ECC03C1_AA ECC03C_AA ECC03C_AA ECC03C6_AA ECC03C8_AA C30CNE100_0 1 ECC03C1_BA ECC03C_BA ECC03C_BA ECC03C6_BA ECC03C8_BA C30CNE10_0 Class ECC0 Non-Combination Mechanically Held Lighting Contactor Two-Wire Control 3 Component Number Type 1 Type 3R Type X Type 7/9 Type 1 Contactor (Open) of Poles Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Catalog Number 1 Continuous Amps 30 ECC0C1_A ECC0C_A ECC0C_A ECC0C6_A ECC0C8_A C30CNM0_ 3 ECC0C1_3A ECC0C_3A ECC0C_3A ECC0C6_3A ECC0C8_3A C30CNM30_ ECC0C1_A ECC0C_A ECC0C_A ECC0C6_A ECC0C8_A C30CNM0_ 5 ECC0C1_5A ECC0C_5A ECC0C_5A ECC0C6_5A ECC0C8_5A C30CNM50_ 6 ECC0C1_6A ECC0C_6A ECC0C_6A ECC0C6_6A ECC0C8_6A C30CNM60_ 7 ECC0C1_7A ECC0C_7A ECC0C_7A ECC0C6_7A ECC0C8_7A C30CNM70_ 8 ECC0C1_8A ECC0C_8A ECC0C_8A ECC0C6_8A ECC0C8_8A C30CNM80_ 9 ECC0C1_9A ECC0C_9A ECC0C_9A ECC0C6_9A ECC0C8_9A C30CNM90_ 10 ECC0C1_AA ECC0C_AA ECC0C_AA ECC0C6_AA ECC0C8_AA C30CNM100_ 1 ECC0C1_BA ECC0C_BA ECC0C_BA ECC0C6_BA ECC0C8_BA C30CNM10_ 1 For first open position (coil voltage), use the table below. The catalog numbers listed in the Type X column are for Type X 30-Grade stainless steel, as indicated by the seventh digit. Example: ECC03CAA. To order Type X 316-Grade stainless steel, change that digit to 9. To order Type painted steel, change that digit to 3. To order non-metallic, change that digit to 5. For details on these alternate enclosures, see Tab 13. Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage A 10/60 or 110/50 D 600/60 or 550/50 T /60 B 0/60 or 0/50 E 08/60 V 8/60 or /50 C 80/60 or 0/50 H 77/60 or 0/50 X 37/60 3 Add C18 modification code for three-wire control. To get the C30CN lighting contactor with normally closed power poles, see Tab 15, for modification codes. Volume 10 Enclosed Control CA0810001E November 01 www.eaton.com V10-T-5