FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

Similar documents
VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

Closed Circuit Cooling Towers

BUTTERFLY VALVES Series 800

WHEATLEY Series 500 Swing Check Valve

Layout Guidelines. Overview

Series 3000 Layout Guidelines

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

GAS FUEL VALVE FORM AGV5 OM 8-03

NGP-250/500 Nitrogen Generator Quick Start Guide

Model PSI Compressor with 3-Gallon Air Tank 12VDC

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Vertical and Horizontal Bladder Tanks

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Related Products: Auto Drain Valve. Model/Specifications. Model

Distribution Transformer Instruction Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

FALL PROTECTION PLAN FALL PROTECTION PROGRAM

Horizontal Bladder Tanks

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

S Surge Arresters

TITAN FLOW CONTROL, INC.

Low Wind High Yields Series

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Types 749B and R130 Changeover Manifolds

Vertical Bladder Tanks

TECHNICAL DATA. Trimpac 256a. October 31, 2013

DESIGN AND PRE - INSTALLATION INFORMATION

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

MUELLER. Xp, & Lineseal 350 Butterfly Valves

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

453 Series Steam Heated Vaporizing Regulator

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

MANUAL. Sesame. Thermoplastic Tank Technologies

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

TECHNICAL DATA OBSOLETE

Model MTB-ASME Vertical Bladder Tanks

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Model MTB-ASME Horizontal Bladder Tanks

Installation, operation & maintenance manual - original version

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

GILMONT ACCUCAL FLOWMETERS

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Model MTB-ASME Vertical Bladder Tanks

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

Bermad Pressure Reducing. Model: 42T

Bermad Model:

Installation Instructions, Pressure Regulator Series

INSTRUCTION MANUAL. Gas Salamander

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

WKM Model 320F Floating Ball Valve

HYDROVEX TTT Membrane Flow Regulator

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

O&M Receiving and Inspection. Storage of Water Treatment Media

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

6301 TYPE CAST IRON SAFETY VALVES

VERTICAL BLADDER TANK

USER MANUAL. JET TST and JET TST S.

Tri-Tech Medical Inc.

2000 lb manual winch

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

Model: 43T. Bermad Pressure Relief Valve

Owner s Manual A VMAC Eliminator After-Cooler

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

OPERATION and MAINTENANCE Guide

TP1 and TP2 Temporary Cone Shaped Strainers

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

29 SERIES - SAFETY VALVE

Owner's Manual THAWLINE BUBBLER DE-ICING SYSTEM

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

INSTALLATION OPERATION MAINTENANCE

MP15 Jockey Pump Controller

Transcription:

FXT FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

FXT Cooling Towers should be rigged and assembled as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the actual rigging and assembly of the equipment to acquaint all personnel with procedures to be followed and to assure that all necessary equipment will be available beforehand. Be sure to have a copy of the certified drawing available for reference. If you do not have a copy of this drawing, or if you need additional information about this unit, contact your local BAC Representative whose name and telephone number are on a label adjacent to the access door. The model number and serial number of the unit are also located in this area.

Table of Contents RIGGING & ASSEMBLY INSTRUCTIONS» FXT COOLING TOWER 1 Introduction 2 Safety 2 Shipping 2 Pre-Rigging Checks 3 Unit Weights 3 Anchoring 3 Cold Weather Operation 3 Location 3 Warranties 2 Rigging & Assembly 4 Rigging 5 Top Inlet Piping Installation

1 FXT COOLING TOWER Introduction WARNING: In the event of extended lifts or where hazards exist, the lifting devices should be used in conjunction with safety slings placed under the unit. CAUTION: Only personnel qualified to do so should undertake operation, maintenance and repair of this equipment. Proper care, procedures and tools must be used in handling, lifting, installing, operating, maintaining and repairing this equipment to prevent personal injury and/or property damage. Safety Adequate precautions appropriate for the installation and location of these products should be taken to safeguard the equipment and the premises from damage and the public from possible injury. The procedures in this manual must be thoroughly reviewed prior to rigging and assembly. Read all warnings, cautions, and notes detailed in the margins. When the fan speed of the unit is to be changed from the factory set speed, including the use of a variable speed device, steps must be taken to avoid operating at or near the fan s critical speed which could result in fan failure and possible injury or damage. Consult with your local BAC Representative on any such applications. Shipping BAC Cooling Towers are factory assembled to assure uniform quality and minimum field assembly. All FXT models ship in one section per cell. For the dimensions and weights of a specific unit or section, refer to the certified drawings. Pre-Rigging Checks When the unit is delivered to the jobsite, it should be checked thoroughly to ensure all required items have been received and are free of any shipping damage prior to signing the bill of lading. The following parts should be inspected: Sheaves and Belts Bearings Bearing Supports Fan Motor(s) Fan(s) and Fan Shaft(s) Float Valve Assembly(s) Water Distribution System Fill Cold Water Basin Accessories Interior Surfaces Exterior Surfaces Air Intake Screens Optional Air Discharge Screens (when provided) Miscellaneous Items: All bolts, nuts, washers, and sealer tape required to assemble sections or component parts are furnished by BAC and shipped with the unit. A checklist inside the envelope marked Customer Information Packet indicates what miscellaneous parts are included with the shipment and where they are packed. This envelope will be attached to the side of the unit or located in a box inside the unit. 2 WWW.BALTIMOREAIRCOIL.COM

Unit Weights Before rigging any unit, the weight of each section should be verified from the unit certified drawing. Some accessories add additional weight as shown on the respective accessory drawings. Anchoring Five-eighths (5/8 ) diameter holes are provided in the bottom flange of the basin section for bolting the unit to the support beams. Refer to the suggested support location drawing included in the submittal for location and quantity of the mounting holes. The unit must be level for proper operation. Anchor bolts must be provided by others. Introduction Safety Shipping Pre-Rigging Checks Unit Weights Anchoring Cold Weather Operation Location Warranties Cold Weather Operation These products must be protected by mechanical and operational methods against damage and/or reduced effectiveness due to possible freeze-up. Please refer to the Common Operation and Maintenance Manual on www.baltimoreaircoil.com, or contact your local BAC Representative for recommended cold weather operation strategies. Location All evaporative cooling equipment must be located to ensure an adequate supply of fresh air to the unit air intakes. When units are located adjacent to walls or in enclosures, care must be taken to ensure the warm, saturated, discharge air is not deflected and recirculated back to the air intakes. Each unit should be located and positioned to prevent the introduction of discharge air into the ventilation system of any building. For detailed recommendations on BAC equipment layout, see our website at www.baltimoreaircoil.com or contact your local Representative. WARNING: Before an actual lift is undertaken, ensure no water, snow, ice, or debris has collected in the basin or elsewhere in the unit. Such accumulations will add substantially to the equipment s lifting weight. NOTE: Each unit must be located and positioned to prevent the introduction of discharge air into the ventilation systems of the building on which the unit is located and of adjacent buildings. Warranties Please refer to the Limitation of Warranties (located in the submittal package) applicable to and in effect at the time of the sale/purchase of these products. WWW.BALTIMOREAIRCOIL.COM 3

2 FXT COOLING TOWER Rigging & Assembly Rigging Refer to Table 1 and Figures 1 and 2 for the recommended vertical dimension H from the lifting device at the top of each unit to the lifting point. In the event of extended lifts or where hazards exist, the lifting devices should be used in conjunction with safety slings placed under the unit. Dimensions (for each cell) Model Number Section Min. H FXT-58 to 95 1 Section 8 FXT-115 to 257 1 Section 12 Table 1. Minimum Vertical Dimension and Spreader Bar Length Lifting Point Lifting Point Lifting Cables Lifting Cables Lifting Devices Lifting Devices H Spreader Bars H 4 WWW.BALTIMOREAIRCOIL.COM Figure 1. Rigging of Models FXT-58 and FXT-68 Safety Slings Figure 2. Rigging of All FXT Models Except for FXT-58 and FXT-68

Top Inlet Piping Installation Use the following drawings and notes when installing top inlet piping on FXT Cooling Towers. FXT Rigging Top Inlet Piping Installation NOTES: 1. All piping must be supported external to the cooling tower and restraint provided to insure no vertical or horizontal movement of the inlet piping. All piping and supports are to be furnished by others, refer to the certified drawing for details on the tower connection size, etc. 2. Inlet piping should rest on the flow divider located 7/8 inch below the top of the water distribution box. The piping that enters the opening must be of proper size (see Figure 3, Detail A). Refer to the certified drawing for details on the cooling tower connection size. 3. Flow control valves are recommended on multi-cell towers to insure proper water distribution and are to be furnished by others. 4. If vibration isolation rails are provided by others, the tower piping must be independently supported, since no provision has been made for the weight of the piping in the selection of the rails. 5. For units installed on vibration isolation rails (provided by others), flexible connections should be installed in the piping just before the tower perimeter. All Piping Supplied by Others Plan View Flow Divider Nozzles Detail A 7/8 M Fan Elevation Figure 3. Top Inlet Piping Installation WWW.BALTIMOREAIRCOIL.COM 5

COOLING TOWERS CLOSED CIRCUIT COOLING TOWERS ICE THERMAL STORAGE EVAPORATIVE CONDENSERS HYBRID PRODUCTS PARTS & SERVICES w w w. B a l t i m o r e A i r c o i l. c o m 7600 Dorsey Run Road, Jessup, MD 20794 Telephone: (410) 799-6200 Fax: (410) 799-6416 2012 Baltimore Aircoil Company R-252/1-A