DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

for Cold-Formed Steel Framing Products

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145

WEDGE-ALL Wedge Anchors

for Cold-Formed Steel Framing Products

Now with SUPREME FRAMING SYSTEM! PRODUCT TECHNICAL GUIDE. Steel Stud Manufacturers Association

Submittal / Substitution Request

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Product Identification

INTRODUCTION. Disclaimer

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS.

Western Lumber SPAN TABLES. Western Wood Products Association. for Floor and Ceiling Joists and Roof Rafters. computed with

The first and only continuous tension holdown system.

CEILING JOISTS ROOF RAFTERS

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Mechanical Anchoring Systems HDA Undercut Anchor Product description. HDA-P Undercut Anchor Pre-Set Type

COLUMNS. Treated Glulam Column 1.9E Laminated Column Architectural Glulam Column

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Vertical and Horizontal Bladder Tanks

Code Compliance Research Report CCRR-0224

Model MTB-ASME Horizontal Bladder Tanks

Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Model MTB-ASME Vertical Bladder Tanks

Drop-In Internally Threaded Anchor (DIAB) Mechanical Anchors. Key features. Material: Carbon steel. Coating: Zinc plated

Anchor Component Material Standard Mechanical Properties

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

STRONGER THAN STEEL SṂ

STRONGER THAN STEEL SṂ

SECTION BUTTERFLY VALVES

Vertical Bladder Tanks

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

PFS Test Report TL-109

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

LiftAlloy TM Chain Slings

Effective Date: April 2018 Void After: April 2019

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor

Risk Control at United Fire Group

IAPMO IS PUBLIC REVIEW DRAFT Thrust Blocking for Rubber Gasketed and Solvent Cement Joints

Check with local zoning official for property line distance requirements.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install.

CHEMICAL. Straight cut rod is provided in the materials listed below and includes nuts / washers.

PUSH PIER SYSTEMS STABILITY. SECURITY. INTEGRITY. Push Pier Systems PN #MBPPT

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

L-header Testing, Evaluation and Design Methodology

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

Fall Protection Checklist. Guardrail System

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

Grading Plan - Drawing No. C-2 - Project Revision 1 dated January 30, 2018.

Piped Air SCBA Refilling System Standard

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS PSH HEAVY DUTY HYDRAULIC WALER RAIL SYSTEM. TABULATED DATA Effective December 10, 2013

HARDPOINT ASESSMENT FOR SUSPENSION BONDAGE

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS HEAVY DUTY HYDRAULIC WALER RAIL SYSTEM. TABULATED DATA Effective August 25, 2015

Continental Industries TRANSITION FITTINGS or FAX Visit

List of Figures. List of Tables

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

MSC Guidelines for Independent Fuel Tanks

Health & Safety Policy and Procedures Manual SECTION 25 RIGGING AND HOISTING EQUIPMENT

Roughneck TM Mesh Slings

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

TRUSS ANCHORING. A guide on the use of Howe and Fink truss anchors

Made in the USA. For Fall Protection Only. SafeLok Part Description

THE CORPORATION OF THE CITY OF BELLEVILLE BY LAW NUMBER

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

WSC Performance Standard and Recommended Installation Procedures for Sanitary Water Well. Pitless Adapters, Pitless Units, And Well Caps

A COMPLETE LISTING OF OUR WASHERS BY INNER DIAMETER STARTS ON PAGE D32

Hardened Steel Washers

BXUV.D935 - Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Section 6. Off-street Bicycle Space Regulations

TOWNSHIP OF DOURO-DUMMER BY-LAW NO

GENERAL GUIDELINES FOR PROPER RIGGING PRACTICES AND INSPECTION & REMOVAL CRITERIA FOR SLINGS PER OSHA

LOAD HUGGER CARGO CONTROL

THE CORPORATION OF THE TOWN OF GREATER NAPANEE BY-LAW NO

LiftAlloy Chain Slings

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141


3/4 SafeClaw Anchorage Connectors

TESTING APPLICATION STANDARD (TAS)

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Mini Channel & Fittings

MSC Guidelines for Compressed Air Systems

SPIRAL PIPE - OVAL SINGLE WALL

Standard Hangers and Adapters

SEI Certification Program Manual

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Residential Fence Tubing

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

THE CORPORATION OF THE TOWNSHIP OF PUSLINCH BY-LAW NUMBER A by-law to regulate enclosures for outdoor swimming pools

Transcription:

ITW BUILDING COMPONENTS GROUP INC. ITW ALPINE HANGERS AND ANCHORS CSI Section: 06 05 23 Wood, Plastic and Composite Fastenings 1.0 RECOGNITION ITW Alpine Hangers and Anchors recognized in this report has been evaluated for use as wood connectors. The structural performance properties of the ITW Alpine Hangers and Anchors complies with the intent of the provisions of the following codes and regulations: 2012, 2009 and 2006 International Building Code (IBC) 2012, 2009 and 2006 International Residential Code (IRC) 2.0 LIMITATIONS Use of the ITW Construction Hardware products described in this report is subject to the following limitations: 2.1 Products shall be manufactured, identified and installed in accordance with this report and manufacturer's installation instructions. A copy of the installation instruction shall be available at the jobsite at all times during installation. Where conflicts occur, the more restrictive shall govern. 2.2 Adjustment Factors for conditions noted in Section 3.2 of this report and applicable codes shall be considered and applied to allowable loads. 2.3 All fasteners and connected wood members shall comply with Sections 4.2.2 and 4.2.3 of this report. 2.4 Use of connector products and fasteners in contact with fire-retardant-treated or preservative-treated lumber shall comply with Section 2304.9.5 of the 2009 IBC or Section R317.3 of the 2009 IRC (2006 IRC Section R319.3), as applicable. The report holder or lumber treater shall be contacted for recommendations on minimum corrosion resistance and connection capacities of fasteners used with the specific proprietary preservative-treated or fireretardant treated lumber. 2.5 Prior to product installation, calculations and details demonstrating compliance with this report shall be submitted to the code official. The calculations and details shall be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. Design loads shall be less than the allowable loads as indicated in Tables 1 through 10 of this report. 2.6 Periodic special inspection shall be: 1. Conducted when the ITW Construction Hardware products are components within the main windforce-resisting system of structures constructed in areas listed in Section 1705.10 of the 2012 IBC (Section 1706.1 of the 2009 IBC and Section 1705.4 of the 2006 IBC). Special inspection requirements do not apply to structures, or portions thereof, that qualify for exception under the 2012 IBC Sections 1704.2, 1705.3, 1705.10.1 or 1705.10.2 (2009 IBC Sections 1704.1, 1704.4, 1706.2 or 1706.3 and Sections 1704.1 and 1704.4 of the 2006 IBC). 2. Conducted in accordance with the applicable 2012 IBC Section 1705.11 and 2009 and 2006 IBC Section 1707 when the product series are components within the seismic-force-resisting system of structures constructed in Seismic Design Category C, D, E or F. Special inspection requirements do not apply to structures, or portions thereof, that qualify for exception under 2012 IBC Sections 1704.2, 1705.3, 1705.11, 1705.11.2 or 1705.11.3 (2009 IBC Sections 1704.1, 1704.4, 1705.3, 1707.3 or 1707.4). 3. Optional and is not normally required for installations under the IRC. However, for an engineered design where calculations are required to be signed by a registered design professional, periodic special inspection requirements and exemptions are as stated in Sections 5.5.1 and 5.5.2, as applicable, for installations under the IRC. 3.0 PRODUCT USE 3.1 General: ITW Hardware Hangers and Anchors are used for connecting wood members together in accordance with Section 2304.9.3 of the IBC. Products may be used in structures regulated under the IRC when a design is submitted in accordance with Section R301.1.3 of the IRC. 3.2 Design: Products are designed for use in dry conditions in wood with a maximum moisture content of 19 percent (16 percent for engineered wood products), and where sustained temperatures do not exceed 100 F (37.8 C). Reductions may be required for wet service installations or sustained temperatures over 100 F (37.8 C). The product described in this Uniform Evaluation Service (UES) Report has been evaluated as an alternative material, design or method of construction in order to satisfy and comply with the intent of the provision of the code, as noted in this report, and for at least equivalence to that prescribed in the code in quality, strength, effectiveness, fire resistance, durability and safely, as applicable, in accordance with IBC Section 104.11. This document shall only be reproduced in its entirety. Copyright 2017 by International Association of Plumbing and Mechanical Officials. All rights reserved. Printed in the United States. Ph: 1-877-4IESRPT Fax: 909.472.4171 web: www.uniform-es.org 4755 East Philadelphia Street, Ontario, California 91761-2816 USA Page 1 of 19

3.3 Installation: General Installation shall be in accordance with the codes in Section 1.0 of this report, this report, and the manufacturer s installation instructions. Where conflicts occur, the more restrictive shall govern. 3.3.1 Installation General: The products in this report shall be properly installed and used in accordance with the installation instructions and design limits in this report and in the manufacturer's published installation instructions. In order to obtain the tabulated allowable loads in this report, all fasteners specified for attachment of the product shall be properly applied. A maximum of 1/8-inch gap may occur between the supported wood member and supporting wood member after attachment of joist hangers. 4.0 PRODUCT DESCRIPTION 4.1 Product information 4.1.1 HA Anchor Series: The HA anchor series is manufactured to attach metal plate connected trusses, framing members and wall members, made of solid sawn or structural composite lumber; to solid sawn or structural composite lumber wall members. The HA4 products shall be used in pairs on each side of the supported member and are available in a left (HA4L) and right (HA4R) style. The HA2.5 product shall be used in pairs on both sides for the supported member. The HA anchors resist upward load from the supported truss or framing member. Attachment is required to the lower portion of the supported truss or framing member, and the top plates of the supporting wall, or wall stud and anchored sill (bottom) plate(s). For HA anchor series Table 1 and Figure 1 of this report reference product dimensions, fastener schedule, wood species, allowable loads, and typical installations. 4.1.2 LS, LMS and MS Strap Series: The LS, LMS and MS Strap Series are manufactured to resist tension loads when attached to solid sawn or structural composite lumber metal plate connected trusses, I-Joist flanges, framing members and wall members. LS, LMS and MS Straps are 1-1/4 inches wide and available in lengths from 9-5/8 inches to 49-5/8 inches. Three fastener holes are located at 3/4 inches on center, in a diagonal pattern, at each end of the strap. Remaining holes are punched at 1-1/2 inches on center in a diagonal pattern. At mid length of each strap there is a 3-inch-long section with no holes. For LS strap series Table 2 and Figure 2 of this report reference product dimensions, fastener schedule, wood species, allowable loads, and typical installations. For LMS strap series Table 3 and Figure 3 of this report reference product dimensions, fastener schedule, wood species, allowable loads and typical installations. For MS strap series Table 4 and Figure 4 of this report reference product dimensions, fastener schedule, wood species, allowable loads, and typical installations. 4.1.3 LST Twisted Strap Series: The LST Twisted Strap Series is manufactured to resist tension load when attached to solid sawn or structural composite lumber metal plate connected trusses, framing members and wall members. LST Twisted Straps are 1-1/4 inches wide and available in lengths from 9-5/8 inches to 24-5/8 inches. Three fastener holes are located at 3/4 inch on center, in a diagonal pattern, at each end of the strap. Remaining holes are punched at 1-1/2 inches on center, in a diagonal pattern. At mid length of each strap is a 3-inch-long section with no holes and a ninety-degree bend extending across the width of the strap for 4-5/8 inches. For LST twisted strap series Table 5 and Figure 5 of this report reference product dimensions, fastener schedule, wood species, and allowable loads, and typical installations. 4.1.4 RS Rolled Strapping Series: The RS Rolled Strapping Series is manufactured to resist tension load when attached to solid sawn or structural composite lumber, metal plate connected trusses, framing members and wall members. RS Rolled Strapping is 1-1/4 inches wide with fastener holes punched at 1-1/4 inches on center, in a staggered pattern, as shown in Figure 6 of this report. Strapping is manufactured in continuous rolls of 250 feet for No. 20 gauge, 200 feet for No.18 gauge, and 150 feet for No. 16 gauge. For RS 150 Table 6, for RS 200 Table 7, and for RS 250 Table 8 of this report reference product dimensions, fastener schedule, wood species, and allowable loads. 4.1.5 TPA Anchor Series: The TPA anchor series is manufactured to resist uplift of the top plate(s) of solid sawn or structural composite lumber wall members from solid sawn or structural composite lumber wall stud members. TPA4 and TPA6 anchors resist upward load on nominal 2x4 and 2x6 respectively, solid sawn or structural composite lumber walls. The TPA anchor is applied over the top wall plate(s) at stud locations and fastener attachment is made into each side of the narrow face of the stud. For TPA anchor series Table 9 and Figure 7 of this report reference product dimensions, fastener schedule, wood species, and allowable loads, and typical installations. 4.1.6 LSC Load Share Clip Series: The LSC load share clip series is manufactured to transfer load between two truss or framing ply members made of solid sawn or structural composite lumber. LSC32 and LSC42 clips transfer downward load between nominal 3x2 and 4x2, respectively, solid sawn or structural composite lumber member plies. LSC32-2 and LSC42-2 clips transfer downward load between double stacked, nominal 3x2 and 4x2 respectively, solid sawn or structural composite lumber members. The LSC clip is applied under the load supporting member then bent over the top of the supporting Page 2 of 19

member as shown in Figures 8A to 8C of this report. Fastener attachment is made into the narrow face of the supported member and wide, top face of the supporting member. For LSC series Table 10 and Figures 8A-C of this report reference product dimensions, fastener schedule, wood species, and allowable loads, and typical installations. 4.1.7 TBR Bracer: The TBR Bracer is manufactured to provide permanent lateral support to the top chord, bottom chord and web members of metal plate connected wood trusses spaced at 24 inches on center. For TBR Bracer, Table 11 and Figure 9 of this report reference product dimensions, fastener schedule, wood species, allowable loads and installations. 4.2 Materials 4.2.1 Steel: The HA anchors are manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS Grade 60 or higher, No. 18 gauge with G90 or G185 Coating, with a minimum uncoated thickness of steel = 0.0428 inch, minimum F y = 60 ksi, and minimum F u = 70 ksi. The LS Straps are manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS or HSLAS Grade 55 or higher, No. 20 gauge with G90 or G185 coating, with a minimum uncoated thickness = 0.0330 inches minimum F y = 55 ksi, and minimum F u = 70 ksi. The LMS Straps are manufactured from mill certified steel coil manufactured to ASTM A653, SS or HSLAS Grade 60 or higher, No. 18 gauge with G90 or G185 coating, with a minimum uncoated thickness = 0.0451 inches, minimum F y = 60 ksi, and minimum F u = 70 ksi. The MS Straps are manufactured from mill certified steel coil manufactured to ASTM A653 SS Grade 50 Class 3 or higher, No. 16 gauge with G90 or G185 Coating with a minimum uncoated thickness of steel = 0.0520 inches, minimum F y = 50 ksi, and minimum F u = 70 ksi. The LST Twisted Straps are manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS Grade 50 Class 1 (Modified) or higher, No. 20 gauge with G90 or G185 Coating, with a minimum uncoated thickness of steel = 0.0329 inch, minimum F y = 50 ksi, and minimum F u = 65 ksi. The RS250 Rolled Strapping is manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS or HSLAS Grade 55 or higher, No. 20 gauge with G90 or G185 coating, with a minimum uncoated thickness = 0.0330 inches, minimum F y = 55 ksi, and minimum F u= 70 ksi. The RS200 Rolled Strapping is manufactured from mill certified steel coil manufactured to ASTM A653 SS or HSLAS Grade 60 or higher, No. 18 gauge with G90 or G185 coating, with a minimum uncoated thickness = 0.0451 inches, minimum F y = 60 ksi, and minimum F u= 70 ksi. The RS150 Rolled Strapping is manufactured from mill certified steel coil manufactured to ASTM A653 SS Grade 50 Class 3 or higher, No. 16 gauge with G90 or G185 Coating with a minimum uncoated thickness of steel = 0.0520 inches, minimum F y = 50 ksi, and minimum F u = 70 ksi. The TPA anchors are manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS Grade 50 Class 1 (Modified) or higher, No. 20 gauge with G90 or G185 Coating with a minimum uncoated thickness of steel = 0.0329 inch, minimum F y = 55 ksi, and minimum F u = 65 ksi. The LSC clips are manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS Grade 40 or higher, No. 18 gauge with G90 or G185 Coating with a minimum uncoated thickness of steel = 0.0428 inch, minimum F y = 40 ksi, and minimum F u = 55 ksi. The TBR Bracer is manufactured from mill certified steel coil manufactured to ASTM A653 or A1063, SS or HSLAS Grade 50 (Class 1) or higher, No. 24 gauge with G90 or G185 coating with a minimum uncoated thickness of steel = 0.0226 inch, minimum F y = 50 ksi, and minimum F u = 65 ksi. 4.2.2 Wood: Connections are designed for use with solid sawn or engineered wood products with a minimum specific gravity, as determined in accordance with the ANSI/AWC NDS for the species, as specified in the allowable load tables. Allowable load tables in this report are for a maximum moisture content of 19 percent for solid sawn lumber and 16 percent for engineered wood products. Wood members not meeting the minimum requirements for the load tables shall be reduced per ANSI/ AWC NDS specifications and calculations. 4.2.3 Fasteners: Fastener shank diameters and lengths for connections are specified in the allowable load tables. All fasteners specified in the allowable load tables in this report are common type nails with minimum yield strength (F yb) of 100,000 psi for 0.099 inch to 0.142-inch diameter fasteners, and 90,000 psi for 0.0142 inch to 0.177-inch diameter fasteners. Fasteners in contact with fire-retardanttreated or preservative-treated lumber shall comply with IBC Section 2304.9.5 or IRC Section 317.3, as applicable. The report holder or lumber treater shall be contacted for reduced capacities and minimum corrosion resistance. Page 3 of 19

5.0 IDENTIFICATION A die-stamp label bearing the name of the manufacturer, the model number, IAPMO ES Mark of Conformity and this evaluation report number (ER-176) identifies the products listed in this report. 8.0 STATEMENT OF RECOGNITION This evaluation report describes the results of research carried out by IAPMO Uniform Evaluation Service on ITW Hardware Hangers and Anchors to assess conformance to the codes shown in Section 1.0 of this report, and serves as documentation of the product certification. or IAPMO UES ER-176 6.0 SUBSTANTIATING DATA Data in accordance with IAPMO UES Evaluation Criteria for Joist Hangers and Miscellaneous Connectors (EC 002-2016), inclusive of tests and calculations. Test results are from laboratories in compliance with ISO/IEC 17025. Data analysis and calculations were performed in accordance with AISI S100 and ANSI/AWC NDS. 7.0 CONTACT INFORMATION Brian Gerber, P.E., S.E. Vice President, Technical Operations Uniform Evaluation Service Richard Beck, PE, CBO, MCP Vice President, Uniform Evaluation Service GP Russ Chaney CEO, The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.org or email us at info@uniform-es.org ITW Building Components Group Inc. 13825 W. Business Center Dr. Unit A Lake Forest, IL 60045 (800) 521-9790 www.alpineitw.com Page 4 of 19

TABLE 1: ALLOWABLE LOADS FOR HA Series Notes: 1. Allowable Load Capacities based on Species and as permitted by applicable building code. 2. Products shown in table are made of No. 18 gauge steel. 3. Products shall be installed in pairs on each side of the connected member for the HA2.5. 4. Four HA4 shall be installed, two on each face, to the connected member. Page 5 of 19

Figure 1- HA Typical Installation Page 6 of 19

TABLE 2: ALLOWABLE LOADS FOR LS STRAPS Overall Dimensions Common Nail Type Spruce-Pine-Fir (0.42 Specific Gravity) Allowable Upward Loads (lbs) Douglas Fir-Larch (0.50 Specific Gravity) Allowable Upward Loads (lbs) Southern Pine (0.55 Specific Gravity) Allowable Upward Loads (lbs) Product Product Width Length Fasteners at Each End Name Gauge Size Quantity 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 LS9 20 1.25 9.625 0.131"x2.5" 4 325 375 405 520 380 435 475 605 410 475 515 660 LS9 20 1.25 9.625 0.148"x1.5" 4 395 450 490 630 460 525 575 735 495 570 620 795 LS9 20 1.25 9.625 0.148"x3.0" 4 395 450 490 630 460 525 575 735 495 570 620 795 LS9 20 1.25 9.625 0.162"x3.5" 4 470 540 590 750 550 630 685 875 595 685 745 915 LS12 20 1.25 12.625 0.131"x2.5" 5 405 470 510 650 475 545 595 760 515 590 645 825 LS12 20 1.25 12.625 0.148"x1.5" 5 490 565 615 785 575 660 715 915 620 715 775 915 LS12 20 1.25 12.625 0.148"x3.0" 5 490 565 615 785 575 660 715 915 620 715 775 915 LS12 20 1.25 12.625 0.162"x3.5" 5 590 675 735 915 685 790 855 915 745 855 915 915 LS15 20 1.25 15.625 0.131"x2.5" 6 490 560 610 780 570 655 710 910 615 710 770 915 LS15 20 1.25 15.625 0.148"x1.5" 6 590 680 735 915 690 790 860 915 745 860 915 915 LS15 20 1.25 15.625 0.148"x3.0" 6 590 680 735 915 690 790 860 915 745 860 915 915 LS15 20 1.25 15.625 0.162"x3.5" 6 705 810 880 915 820 915 915 915 895 915 915 915 LS18 20 1.25 18.625 0.131"x2.5" 7 570 655 710 910 665 765 830 915 720 830 900 915 LS18 20 1.25 18.625 0.148"x1.5" 7 690 790 860 915 800 915 915 915 870 915 915 915 LS18 20 1.25 18.625 0.148"x3.0" 7 690 790 860 915 800 915 915 915 870 915 915 915 LS18 20 1.25 18.625 0.162"x3.5" 7 825 915 915 915 915 915 915 915 915 915 915 915 LS21 20 1.25 21.625 0.131"x2.5" 8 650 750 815 915 760 870 915 915 825 915 915 915 LS21 20 1.25 21.625 0.148"x1.5" 8 785 905 915 915 915 915 915 915 915 915 915 915 LS21 20 1.25 21.625 0.148"x3.0" 8 785 905 915 915 915 915 915 915 915 915 915 915 LS21 20 1.25 21.625 0.162"x3.5" 8 915 915 915 915 915 915 915 915 915 915 915 915 LS24 20 1.25 24.625 0.131"x2.5" 9 735 840 915 915 855 915 915 915 915 915 915 915 LS24 20 1.25 24.625 0.148"x1.5" 9 885 915 915 915 915 915 915 915 915 915 915 915 LS24 20 1.25 24.625 0.148"x3.0" 9 885 915 915 915 915 915 915 915 915 915 915 915 LS24 20 1.25 24.625 0.162"x3.5" 9 915 915 915 915 915 915 915 915 915 915 915 915 Notes: 1. Allowable load capacities are based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 20 gauge steel. Figure 2- LS Typical Installation Page 7 of 19

TABLE 3: ALLOWABLE LOADS FOR LMS STRAPS Figure 3- LMS Typical Installation Page 8 of 19

TABLE 4: ALLOWABLE LOADS FOR MS STRAPS Spruce-Pine-Fir (0.42 Specific Gravity) Allowable Upward Loads (lbs) Overall Dimensions Common Nail Type Allowable Upward Loads (lbs) Product Product Width Length Fasteners at Each End Name Gauge Size Quantity 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 MS21 16 1.25 21.625 0.131"x2.5" 8 690 790 860 1100 800 920 1000 1280 865 995 1080 1385 MS21 16 1.25 21.625 0.148"x1.5" 8 825 950 1030 1320 960 1100 1200 1535 1040 1195 1300 1660 MS21 16 1.25 21.625 0.148"x3.0" 8 825 950 1030 1320 960 1100 1200 1535 1040 1195 1300 1660 MS21 16 1.25 21.625 0.162"x3.5" 8 975 1125 1220 1565 1135 1305 1420 1765 1230 1415 1540 1765 MS24 16 1.25 24.625 0.131"x2.5" 9 775 890 965 1240 900 1035 1125 1440 975 1120 1215 1555 MS24 16 1.25 24.625 0.148"x1.5" 9 930 1065 1160 1485 1080 1240 1350 1725 1170 1345 1460 1765 MS24 16 1.25 24.625 0.148"x3.0" 9 930 1065 1160 1485 1080 1240 1350 1725 1170 1345 1460 1765 MS24 16 1.25 24.625 0.162"x3.5" 9 1100 1265 1375 1760 1280 1470 1600 1765 1385 1595 1730 1765 MS27 16 1.25 27.625 0.131"x2.5" 10 860 990 1075 1375 1000 1150 1250 1600 1080 1245 1350 1730 MS27 16 1.25 27.625 0.148"x1.5" 10 1030 1185 1290 1650 1200 1380 1495 1765 1300 1490 1620 1765 MS27 16 1.25 27.625 0.148"x3.0" 10 1030 1185 1290 1650 1200 1380 1495 1765 1300 1490 1620 1765 MS27 16 1.25 27.625 0.162"x3.5" 10 1220 1405 1525 1765 1420 1635 1765 1765 1540 1765 1765 1765 MS30 16 1.25 30.625 0.131"x2.5" 11 945 1085 1180 1515 1100 1265 1375 1755 1190 1370 1485 1765 MS30 16 1.25 30.625 0.148"x1.5" 11 1135 1305 1415 1765 1320 1515 1645 1765 1425 1640 1765 1765 MS30 16 1.25 30.625 0.148"x3.0" 11 1135 1305 1415 1765 1320 1515 1645 1765 1425 1640 1765 1765 MS30 16 1.25 30.625 0.162"x3.5" 11 1345 1545 1680 1765 1565 1765 1765 1765 1695 1765 1765 1765 MS33 16 1.25 33.625 0.131"x2.5" 12 1030 1185 1290 1650 1200 1380 1500 1765 1295 1490 1620 1765 MS33 16 1.25 33.625 0.148"x1.5" 12 1235 1420 1545 1765 1435 1655 1765 1765 1555 1765 1765 1765 MS33 16 1.25 33.625 0.148"x3.0" 12 1235 1420 1545 1765 1435 1655 1765 1765 1555 1765 1765 1765 MS33 16 1.25 33.625 0.162"x3.5" 12 1465 1685 1765 1765 1705 1765 1765 1765 1765 1765 1765 1765 MS36 16 1.25 36.625 0.131"x2.5" 13 1115 1285 1395 1765 1300 1495 1625 1765 1405 1615 1755 1765 MS36 16 1.25 36.625 0.148"x1.5" 13 1340 1540 1675 1765 1555 1765 1765 1765 1685 1765 1765 1765 MS36 16 1.25 36.625 0.148"x3.0" 13 1340 1540 1675 1765 1555 1765 1765 1765 1685 1765 1765 1765 MS36 16 1.25 36.625 0.162"x3.5" 13 1590 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 MS39 16 1.25 39.625 0.131"x2.5" 14 1205 1385 1505 1765 1400 1610 1745 1765 1515 1740 1765 1765 MS39 16 1.25 39.625 0.148"x1.5" 14 1445 1660 1765 1765 1675 1765 1765 1765 1765 1765 1765 1765 MS39 16 1.25 39.625 0.148"x3.0" 14 1445 1660 1765 1765 1675 1765 1765 1765 1765 1765 1765 1765 MS39 16 1.25 39.625 0.162"x3.5" 14 1710 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 Notes: 1. Allowable load capacities are based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 16 gauge steel. Douglas Fir-Larch (0.50 Specific Gravity) Allowable Upward Loads (lbs) Southern Pine (0.55 Specific Gravity) Figure 4- MS Typical Installation Page 9 of 19

Product Name Overall Dimensions Width TABLE 5: ALLOWABLE LOADS FOR LST STRAP Length Spruce-Pine-Fir (0.42 Specific Gravity) Common Nail Type Fasteners at Each End Allowable Upward Loads (lbs) Size Quantity 1 1.15 1.25 1.6 LS9T 1.25 9.625 0.148"x1.5" 3 295 340 370 475 LS12T 1.25 12.625 0.148"x1.5" 4 395 455 495 635 LS15T 1.25 15.625 0.148"x1.5" 5 495 570 620 795 LS18T 1.25 18.625 0.148"x1.5" 6 595 685 745 950 LS21T 1.25 21.625 0.148"x1.5" 7 695 800 865 1090 LS24T 1.25 24.625 0.148"x1.5" 8 795 910 990 1090 Product Name Douglas Fir-Larch (0.50 Specific Gravity) Overall Dimensions Common Nail Type Allowable Upward Loads (lbs) Fasteners at Each Width Length End Size Quantity 1 1.15 1.25 1.6 LS9T 1.25 9.625 0.148"x1.5" 3 345 400 435 555 LS12T 1.25 12.625 0.148"x1.5" 4 460 530 580 740 LS15T 1.25 15.625 0.148"x1.5" 5 580 665 720 925 LS18T 1.25 18.625 0.148"x1.5" 6 695 795 865 1090 LS21T 1.25 21.625 0.148"x1.5" 7 810 930 1010 1090 LS24T 1.25 24.625 0.148"x1.5" 8 925 1065 1090 1090 Product Name Southern Pine (0.55 Specific Gravity) Overall Dimensions Common Nail Type Allowable Upward Loads (lbs) Fasteners at Each Width Length End Size Quantity 1 1.15 1.25 1.6 LS9T 1.25 9.625 0.148"x1.5" 3 375 435 470 600 LS12T 1.25 12.625 0.148"x1.5" 4 500 575 625 790 LS15T 1.25 15.625 0.148"x1.5" 5 625 720 785 1005 LS18T 1.25 18.625 0.148"x1.5" 6 755 865 940 1090 LS21T 1.25 21.625 0.148"x1.5" 7 880 1010 1090 1090 LS24T 1.25 24.625 0.148"x1.5" 8 1005 1090 1090 1090 Notes: 1. Allowable Load Capacities based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 20 gauge steel. Page 10 of 19

Figure 5- LST Typical Installations Page 11 of 19

TABLE 6: ALLOWABLE LOADS FOR RS150 ROLLED STRAPPING (lbs) Product Name Strap Dimensions Width Minimum Length Common Nail Type Fasteners (Each End) Southern Pine (0.55 Specific Gravity) Douglas Fir-Larch (0.50 Specific Gravity) Spruce-Pine-Fir (0.42 Specific Gravity) 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 RS150 1 1/4 6-1/4 8-3/4 11-1/4 13-3/4 16-1/4 18-3/4 21-1/4 23-3/4 26-1/4 28-3/4 31-1/4 33-3/4 36-1/4 38-3/4 41-1/4 43-3/4 46-1/4 48-3/4 (2) 0.131"x1.5" 215 250 270 345 200 230 250 320 170 200 215 275 (2) 0.148"x1.5" 260 300 325 415 240 275 300 385 205 235 260 330 (2) 0.162"x2.5" 310 355 385 495 285 325 355 455 245 280 305 390 (3) 0.131"x1.5" 325 375 405 520 300 345 375 480 260 295 320 415 (3) 0.148"x1.5" 390 450 485 625 360 415 450 575 310 355 385 495 (3) 0.162"x2.5" 460 530 575 740 425 490 535 680 365 420 460 585 (4) 0.131"x1.5" 430 495 540 690 400 460 500 640 345 395 430 550 (4) 0.148"x1.5" 520 595 650 830 480 550 600 765 410 475 515 660 (4) 0.162"x2.5" 615 710 770 985 570 655 710 910 490 560 610 780 (5) 0.131"x1.5" 540 620 675 865 500 575 625 800 430 495 535 690 (5) 0.148"x1.5" 650 745 810 1040 600 690 750 960 515 595 645 825 (5) 0.162"x2.5" 770 885 960 1230 710 815 890 1135 610 700 765 975 (6) 0.131"x1.5" 650 745 810 1040 600 690 750 960 515 595 645 825 (6) 0.148"x1.5" 780 895 975 1245 720 825 900 1150 620 710 775 990 (6) 0.162"x2.5" 925 1060 1155 1480 850 980 1065 1365 735 845 915 1175 (7) 0.131"x1.5" 755 870 945 1210 700 805 875 1120 600 690 750 965 (7) 0.148"x1.5" 910 1045 1135 1455 840 965 1050 1340 720 830 900 1155 (7) 0.162"x2.5" 1080 1240 1345 1725 995 1145 1245 1590 855 985 1070 1370 (8) 0.131"x1.5" 865 995 1080 1385 800 920 1000 1280 690 790 860 1100 (8) 0.148"x1.5" 1040 1195 1300 1660 960 1100 1200 1535 825 950 1030 1320 (8) 0.162"x2.5" 1230 1415 1540 1960 1135 1305 1420 1820 975 1125 1220 1565 (9) 0.131"x1.5" 975 1120 1215 1555 900 1035 1125 1440 775 890 965 1240 (9) 0.148"x1.5" 1170 1345 1460 1870 1080 1240 1350 1725 930 1065 1160 1485 (9) 0.162"x2.5" 1385 1595 1730 1960 1280 1470 1600 1960 1100 1265 1375 1760 (10) 0.131"x1.5" 1080 1245 1350 1730 1000 1150 1250 1600 860 990 1075 1375 (10) 0.148"x1.5" 1300 1490 1620 1960 1200 1380 1495 1915 1030 1185 1290 1650 (10) 0.162"x2.5" 1540 1770 1925 1960 1420 1635 1775 1960 1220 1405 1525 1955 (11) 0.131"x1.5" 1190 1370 1485 1905 1100 1265 1375 1755 945 1085 1180 1515 (11) 0.148"x1.5" 1425 1640 1785 1960 1320 1515 1645 1960 1135 1305 1415 1815 (11) 0.162"x2.5" 1695 1950 1960 1960 1565 1795 1955 1960 1345 1545 1680 1960 (12) 0.131"x1.5" 1295 1490 1620 1960 1200 1380 1500 1915 1030 1185 1290 1650 (12) 0.148"x1.5" 1555 1790 1945 1960 1435 1655 1795 1960 1235 1420 1545 1960 (12) 0.162"x2.5" 1850 1960 1960 1960 1705 1960 1960 1960 1465 1685 1830 1960 (13) 0.131"x1.5" 1405 1615 1755 1960 1300 1495 1625 1960 1115 1285 1395 1790 (13) 0.148"x1.5" 1685 1940 1960 1960 1555 1790 1945 1960 1340 1540 1675 1960 (13) 0.162"x2.5" 1960 1960 1960 1960 1845 1960 1960 1960 1590 1825 1960 1960 (14) 0.131"x1.5" 1515 1740 1890 1960 1400 1610 1745 1960 1205 1385 1505 1925 (14) 0.148"x1.5" 1815 1960 1960 1960 1675 1930 1960 1960 1445 1660 1805 1960 (14) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1710 1960 1960 1960 (15) 0.131"x1.5" 1620 1865 1960 1960 1500 1720 1870 1960 1290 1485 1610 1960 (15) 0.148"x1.5" 1945 1960 1960 1960 1795 1960 1960 1960 1545 1780 1930 1960 (15) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1830 1960 1960 1960 (16) 0.131"x1.5" 1730 1960 1960 1960 1600 1835 1960 1960 1375 1580 1720 1960 (16) 0.148"x1.5" 1960 1960 1960 1960 1915 1960 1960 1960 1650 1895 1960 1960 (16) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1955 1960 1960 1960 (17) 0.131"x1.5" 1840 1960 1960 1960 1695 1950 1960 1960 1460 1680 1825 1960 (17) 0.148"x1.5" 1960 1960 1960 1960 1960 1960 1960 1960 1750 1960 1960 1960 (17) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 (18) 0.131"x1.5" 1945 1960 1960 1960 1795 1960 1960 1960 1545 1780 1935 1960 (18) 0.148"x1.5" 1960 1960 1960 1960 1960 1960 1960 1960 1855 1960 1960 1960 (18) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 (19) 0.131"x1.5" 1960 1960 1960 1960 1895 1960 1960 1960 1635 1880 1960 1960 (19) 0.148"x1.5" 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 (19) 0.162"x2.5" 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 1960 Notes: 1. Allowable load capacities are based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 16 gauge steel. 3. Overall length of rolled strap is 150 feet. Page 12 of 19

TABLE 7: ALLOWABLE LOADS FOR RS200 ROLLED STRAPPING (lbs) Product Name Width RS200 1 1/4 Strap Dimensions Minimum Length 6-1/4 8-3/4 11-1/4 13-3/4 16-1/4 18-3/4 21-1/4 23-3/4 26-1/4 28-3/4 31-1/4 33-3/4 36-1/4 38-3/4 41-1/4 Common Nail Type Fasteners (Each End) Southern Pine (0.55 Specific Gravity) Douglas Fir-Larch (0.50 Specific Gravity) Spruce-Pine-Fir (0.42 Specific Gravity) 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 (2) 0.131"x1.5" 210 245 265 340 195 225 245 310 165 190 210 270 (2) 0.148"x1.5" 255 290 320 405 235 270 295 375 200 230 250 320 (2) 0.162"x2.5" 305 350 380 485 280 320 350 445 240 275 300 385 (3) 0.131"x1.5" 315 365 395 505 290 335 365 465 250 290 315 400 (3) 0.148"x1.5" 380 440 475 610 350 405 440 560 300 345 375 485 (3) 0.162"x2.5" 455 520 570 725 420 480 525 670 360 415 450 575 (4) 0.131"x1.5" 420 485 525 675 390 450 485 625 335 385 420 535 (4) 0.148"x1.5" 510 585 635 815 470 540 585 750 405 465 505 645 (4) 0.162"x2.5" 605 695 755 970 560 640 700 895 480 550 600 765 (5) 0.131"x1.5" 525 605 660 845 485 560 610 780 420 480 525 670 (5) 0.148"x1.5" 635 730 795 1015 585 675 730 935 505 580 630 805 (5) 0.162"x2.5" 755 870 945 1210 700 805 870 1115 600 690 750 960 (6) 0.131"x1.5" 635 730 790 1015 585 670 730 935 500 575 625 805 (6) 0.148"x1.5" 760 875 955 1220 705 810 880 1125 605 695 755 965 (6) 0.162"x2.5" 910 1045 1135 1455 835 965 1045 1340 720 825 900 1150 (7) 0.131"x1.5" 740 850 925 1180 680 785 850 1090 585 675 730 935 (7) 0.148"x1.5" 890 1025 1110 1425 820 945 1025 1310 705 810 880 1125 (7) 0.162"x2.5" 1060 1220 1325 1560 975 1125 1220 1560 840 965 1050 1340 (8) 0.131"x1.5" 845 970 1055 1350 780 895 975 1245 670 770 835 1070 (8) 0.148"x1.5" 1015 1170 1270 1560 935 1080 1170 1500 805 925 1005 1290 (8) 0.162"x2.5" 1210 1395 1515 1560 1115 1285 1395 1560 960 1100 1200 1535 (9) 0.131"x1.5" 950 1090 1185 1520 875 1005 1095 1400 750 865 940 1205 (9) 0.148"x1.5" 1145 1315 1430 1560 1055 1215 1320 1560 905 1040 1130 1450 (9) 0.162"x2.5" 1365 1560 1560 1560 1255 1445 1560 1560 1080 1240 1350 1560 (10) 0.131"x1.5" 1055 1215 1320 1560 975 1120 1215 1555 835 960 1045 1340 (10) 0.148"x1.5" 1270 1460 1560 1560 1170 1345 1465 1560 1005 1155 1260 1560 (10) 0.162"x2.5" 1515 1560 1560 1560 1395 1560 1560 1560 1200 1380 1495 1560 (11) 0.131"x1.5" 1160 1335 1450 1560 1070 1230 1340 1560 920 1060 1150 1470 (11) 0.148"x1.5" 1400 1560 1560 1560 1290 1480 1560 1560 1105 1275 1385 1560 (11) 0.162"x2.5" 1560 1560 1560 1560 1535 1560 1560 1560 1320 1515 1560 1560 (12) 0.131"x1.5" 1265 1455 1560 1560 1170 1345 1460 1560 1005 1155 1255 1560 (12) 0.148"x1.5" 1525 1560 1560 1560 1405 1560 1560 1560 1210 1390 1510 1560 (12) 0.162"x2.5" 1560 1560 1560 1560 1560 1560 1560 1560 1435 1560 1560 1560 (13) 0.131"x1.5" 1370 1560 1560 1560 1265 1455 1560 1560 1085 1250 1360 1560 (13) 0.148"x1.5" 1560 1560 1560 1560 1525 1560 1560 1560 1310 1505 1560 1560 (13) 0.162"x2.5" 1560 1560 1560 1560 1560 1560 1560 1560 1555 1560 1560 1560 (14) 0.131"x1.5" 1475 1560 1560 1560 1360 1560 1560 1560 1170 1345 1465 1560 (14) 0.148"x1.5" 1560 1560 1560 1560 1560 1560 1560 1560 1410 1560 1560 1560 (14) 0.162"x2.5" 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 (15) 0.131"x1.5" 1560 1560 1560 1560 1460 1560 1560 1560 1255 1440 1560 1560 (15) 0.148"x1.5" 1560 1560 1560 1560 1560 1560 1560 1560 1510 1560 1560 1560 (15) 0.162"x2.5" 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 (16) 0.131"x1.5" 1560 1560 1560 1560 1555 1560 1560 1560 1340 1540 1560 1560 (16) 0.148"x1.5" 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 (16) 0.162"x2.5" 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 1560 Notes: 1. Allowable load capacities are based on the specie and load duration factor as permitted by applicable building code. 2. Products shown in table are made of 18 gauge steel. 3. Overall length of rolled strap is 200 feet Page 13 of 19

TABLE 8: ALLOWABLE LOADS FOR RS250 ROLLED STRAPPING (lbs) Notes: 1. Allowable load capacities are based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 20 gauge steel. 3. Overall length of rolled strap is 250 feet. Page 14 of 19

Figure 6 - RS - Rolled Strapping Page 15 of 19

Overall Dimensions Product Product Width Height Depth Nail Nail Name Gauge Size Quantity TABLE 9: ALLOWABLE LOADS FOR TPA STRAPS Common Nail Type Spruce-Pine-Fir Douglas Fir-Larch Southern Pine (0.42 Specific Gravity) (0.50 Specific Gravity) (0.55 Specific Gravity) Allowable Upward Loads (lbs) Allowable Upward Loads (lbs) Allowable Upward Loads (lbs) Duration of Load Factor Duration of Load Factor Duration of Load Factor 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 TPA4 20 3.5625 7.5625 1.25 0.131"x2.5" 2 165 190 205 265 190 220 240 305 210 240 260 330 TPA4 20 3.5625 7.5625 1.25 0.148"x3.0" 2 155 180 195 250 230 265 290 370 250 290 315 400 TPA4 20 3.5625 7.5625 1.25 0.131"x2.5" 4 330 380 410 475 385 440 475 475 415 475 475 475 TPA4 20 3.5625 7.5625 1.25 0.148"x3.0" 4 310 360 390 500 460 530 580 595 500 575 595 595 TPA4 20 3.5625 7.5625 1.25 0.131"x2.5" 6 495 565 615 790 575 660 720 920 625 715 780 995 TPA4 20 3.5625 7.5625 1.25 0.148"x3.0" 6 470 540 585 750 695 795 865 1110 755 865 940 1205 TPA4 20 3.5625 7.5625 1.25 0.131"x2.5" 8 655 755 820 1050 765 880 955 1225 830 955 1040 1295 TPA4 20 3.5625 7.5625 1.25 0.148"x3.0" 8 625 720 780 1000 925 1065 1155 1480 1005 1155 1255 1605 TPA6 20 5.5625 8.0625 1.25 0.131"x2.5" 2 165 190 205 265 190 220 240 305 210 240 260 330 TPA6 20 5.5625 8.0625 1.25 0.148"x3.0" 2 155 180 195 250 230 265 290 370 250 290 315 400 TPA6 20 5.5625 8.0625 1.25 0.131"x2.5" 4 330 380 410 525 385 440 480 610 415 480 520 685 TPA6 20 5.5625 8.0625 1.25 0.148"x3.0" 4 310 360 390 500 460 530 580 740 500 575 625 785 TPA6 20 5.5625 8.0625 1.25 0.131"x2.5" 6 495 565 615 790 575 660 720 920 625 715 780 995 TPA6 20 5.5625 8.0625 1.25 0.148"x3.0" 6 470 540 585 750 695 795 865 1110 755 865 940 1160 TPA6 20 5.5625 8.0625 1.25 0.131"x2.5" 8 655 755 820 1050 765 880 955 1225 830 955 1040 1330 TPA6 20 5.5625 8.0625 1.25 0.148"x3.0" 8 625 720 780 1000 925 1065 1155 1460 1005 1155 1255 1460 TPA6 20 5.5625 8.0625 1.25 0.131"x2.5" 10 820 945 1025 1315 955 1100 1195 1420 1040 1195 1300 1420 TPA6 20 5.5625 8.0625 1.25 0.148"x3.0" 10 780 900 975 1250 1155 1330 1445 1675 1255 1445 1570 1675 Notes: Allowable Load Capacities are based on the tabulated species and load duration factor. Figure 7- TPA Typical Installation Page 16 of 19

Product Name Width TABLE 10: ALLOWABLE LOADS FOR LSC SERIES Spruce-Pine-Fir (0.42 Specific Gravity) Overall Dimensions Common Nail Type Fasteners Allowable Downward Loads Quantity (lbs) Height Depth Size LSC32 3 1.5 2.5 LSC32-2 3 3 2.5 LSC42 3 1.5 3.5 LSC42-2 3 3 3.5 Product Name Overall Dimensions Width Height Depth LSC32 3 1.5 2.5 LSC32-2 3 3 2.5 LSC42 3 1.5 3.5 LSC42-2 3 3 3.5 Product Name Overall Dimensions Width Height Depth LSC32 3 1.5 2.5 LSC32-2 3 3 2.5 LSC42 3 1.5 3.5 LSC42-2 3 3 3.5 Supportin g Member Supported Member 1 1.15 1.25 1.6 0.131"x1.5" 3 3 565 565 565 565 Douglas Fir-Larch (0.50 Specific Gravity) Common Nail Type Fasteners Size Supportin g Member Quantity Supported Member Allowable Downward Loads (lbs) 1 1.15 1.25 1.6 0.131"x1.5" 3 3 770 770 770 770 Southern Pine (0.55 Specific Gravity) Common Nail Type Fasteners Size Supporting Member Quantity Supported Member Allowable Downward Loads (lbs) 1 1.15 1.25 1.6 0.131"x1.5" 3 3 900 900 900 900 Notes: 1. Allowable Load Capacities based on the tabulated species and load duration factor. 2. Products shown in table are made of No. 18 gauge steel. Page 17 of 19

FIgure 8A: Typical LSC Figure 8B: Typical LSC Load Application FIgure 8C: Typical LSC Installation Page 18 of 19

TABLE 11: ALLOWABLE LOADS FOR TBR BRACER Product Name Overall Dimensions Length L (in.) Width W (in.) Depth D Fasteners Per Bracer Total Type Load Type Allowable Loads (lb) Spruce-Pine-Fir Douglas Fir-Larch Southern Pine (0.42 Specific Gravity) (0.50 Specific Gravity) (0.55 Specific Gravity) 1 1.15 1.25 1.6 1 1.15 1.25 1.6 1 1.15 1.25 1.6 TBR24 (Reduced Nailing) 25-9/16 1-1/2 5/8 2 10dx1-1/2 Tension 175 175 175 175 225 225 225 225 230 230 230 230 TBR24 (Reduced Nailing) 25-9/16 1-1/2 5/8 2 10dx1-1/2 Compression 370 385 395 430 515 530 545 585 485 505 515 560 TBR24 25-9/16 1-1/2 5/8 4 10dx1-1/2 Tension 375 390 400 400 510 510 510 510 495 510 510 510 TBR24 25-9/16 1-1/2 5/8 4 10dx1-1/2 Compression 400 420 435 480 560 585 605 605 545 575 595 605 Notes: 1. TBR24 product is made of No. 24 gauge steel. 2. Allowable load capacities based on the tabulated species and load duration factor. 3. The required permanent lateral support for wood trusses shall be designed in accordance with Section 2303.4.1.5 of 2006 IBC or Section 2303.4.1.2 of 2009 IBC and 2012IBC. 4. To obtain reduced nailing bracer capacities in tension and compression, nails shall be installed at each end of the bracer on narrow face. 5. To obtain maximum bracer capacities in tension and compression, nails shall be installed at each end of the bracer on both narrow face and wide face. Figure 9: TBR BRACER Page 19 of 19