combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Similar documents
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Model EXAxt AV550G. Averaging Oxygen Analyzer

Autocalibration Systems For In Situ Oxygen Analyzers

PRODUCT CONFORMITY CERTIFICATE

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Zirconia Oxygen Analyzer Systems

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Autocalibration Systems for In Situ Oxygen Analyzers

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

FAS-W. Features. Applications. Automatic condensation hygrometer

FLAMMABLE GAS SENSOR/TRANSMITTER

BUBBLER CONTROL SYSTEM

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Infrared Linescanners

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Oxygen Flue Gas Analyzer BA 2000

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

SonoMeter 30 Energy Meters

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

BUBBLER CONTROL SYSTEM

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Technical Data Sheet MF010-O-LC

HumiSys HF High Flow RH Generator

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

CONTENTS OVERVIEWS PRODUCT INFORMATION

Type2 Oxygen probe system for Nexus NX6100 and PPC6000

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ISM-3 User Manual PBI D 04/2013

RAM Operation Manual

Laser Gas Analyzer LG2000. The Laser Technologies

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Pressure measurement is a family affair

Operation & Maintenance Manual GDS-68XP

High-performance submersible pressure transmitter For level measurement Model LH-20

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Precision pressure sensor Basic version Model CPT6020

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Your local gas generation partner. Precision series Modular gas generation solution for GC.

C-Flow Coriolis Mass Flow Meters

Pressure switch Type BCP

Pneumatic high-pressure controller Model CPC7000

RAM 4021-DPX Operation Manual

Mass Flowmeters. Mass Flowmeters for Gases

We measure it. For gas and water installers. testo hpa. bar

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Instruction Manual. Biogas Analyzer InCa Bio 04

Oxymax COS61/COS61D. Technical Information

Pneumatic high-pressure controller Model CPC7000

Flow Measurement SITRANS F C

For the highest operational safety around the clock

How to specify a product. Process Sensors and Mechanical Instruments

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Installation and Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

780S Ultra High Purity Series

Royce Interface Level Analyzer and Sensors

Porter Analytical & Industrial Products

Mass Flow Meter (MFM) for Gases

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Oxygen & Binary Gas Measurement and Analysis

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

High-performance submersible pressure transmitter For level measurement Model LH-20

Mass Flow Controller (MFC) for Gases

Protec P3000 (XL) Helium Sniffer Leak Detector

Series Environmental Chambers

RAM 4021 Operation Manual

GasSense NDIR User Manual

EPP4 Pressure Regulator Basic G 1/4"

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

with O 2 Controller Instruction Manual

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Mass Flow Controller (MFC) for Gases

Features. Description

Instruction Manual. Analyser AMS for AMS ZrO 2 - Probes

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

process measurement solutions The level solutions catalogue

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Transcription:

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company

Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen within boilers and furnaces. The wide range of products available have the measurement capability, performance and quality to meet most industrial applications. Features & Benefits Simple installation and operation - 4-key user interface controls all functions Outstanding sensor reliability - Robust design with large surface area and rigid bonding High product confidence - 24 month complete probe warranty Proven performance - TÜV approved Service and maintenance carried out on-site - All parts are field replaceable Straightforward integration in plant control system - Modbus communications capability Measurement systems for most applications - Wide range of product options available Simple User Interface Simple push-button operation combined with a clear LED display enable complete electronic control of the probe functions. Full setup and diagnostic information is also accessible through the user interface. Serial Communications Genesis probes can communicate using the RS485 modbus protocol, for straightforward integration into the plant DCS. There are also both 4-20 ma analog and relay outputs.

Analyzers the world s first fully-integrated stand-alone, flue gas oxygen analysis system Unique Flexibility Genesis uniquely mounts the user interface onto the probe itself. This enables complete local control at the measurement location and reduces installation costs. Alternatively, the user interface can be detached and located for remote operation. Rugged Sensor design The sensor is manufactured to the highest possible standards - allowing a minimum 2 year warranty. The sensor design gives a large surface area and an excellent bond between the zirconia and stainless steel holder. Probe filter assembly The probe filter simply fits in place with 4 retaining screws, and maintains the integrity of the probe. Flame arrestors are also available. Versatile probe and mounting Genesis oxygen probes are available in various lengths with a range of mounting flange options. Universal compatibility The universal control unit is fully compatible with all genesis oxygen probes. It provides remote control, operation and displays readings for the measurement probe. In addition, the universal control unit is fully compatible with existing zirconia sensor oxygen probes from most manufacturers.

Product Range General Purpose Flue Gas Temperature Reading Probe Type Control Unit Type Display Low Temperature 0-600 C/ 32-1112 F Integrated Genesis g1200 Integral with probe Low Temperature 0-600 C/ 32-1112 F Remote Genesis g1210 Genesis g1220 High Temperature 600-1400 C/ 1112-2552 F Remote Genesis g1230 Genesis g1220 g1200 Stand-alone, Low Temperature Fully-integrated Probe The g1200 is the world s first fully-integrated oxygen analysis probe. The g1200 combines the measurement probe with the control unit into a single, fully integrated system. For applications where probe access is straightforward, the g1200 is the ideal choice as it reduces both installation time and costs. g1210 Low Temperature Probe The g1210 measurement probe is capable of direct, in-situ measurement in all combustion processes up to 600 C/1112 F. Display of measurement readings and probe diagnostics is made remotely from the Universal Control Unit (g1220). The g1210 is ideally suited where normal access to the probe is restricted or environmentally hostile. g1230 High Temperature Probe The g1230 measurement probe is capable of in-situ oxygen measurement in higher temperature combustion processes (such as furnaces and process heaters) up to 1400 C/2552 F. The probes come in varying lengths, with a choice of protection sheaths for specific temperature ranges. Display of measurement readings is made remotely using the Universal Control Unit (g1220). g1220 Universal Control Unit The universal control unit has identical functionality to the control module of the g1200, but is mounted in the plant control room or other accessible location for easy access. Control, display and diagnostics information Simple user interface with LED display User programmable for maximum flexibility Automatic fault detection Modbus communications Small and compact IP65/NEMA 4 protection

Applications Combustion Efficiency Combustion Control Excess Air Measurement Pollution Control Specifications g1200 and g1210 Low Temperature Probes Measuring Range: 0 to 5, 0 to 25 % Vol O 2 selectable Accuracy: ±1 % of full scale Repeatability: ±0.5 % of full scale on analog outputs Response Time: 90 % of full scale within 5 seconds Measuring Method: Zirconia oxide sensor Flue Gas Temp Range: 0 to 600 C/32 to 1112 F Probe Lengths Options: 0.4/1.0/1.5/2.0 m/1.3/3.3/4.9/6.6 ft Weight: (g1200) 8.8 to 15.1 kg/19.4 to 33.3 lb Weight: (g1210) 6.8 to 13.1 kg/15 to 28.9 lb g1230 High Temperature Probe Measuring Range: 0 to 5, 0 to 25 % Vol. O 2 selectable Accuracy: ±1 % of full scale Repeatability: ±0.5 % of full scale on analog outputs Response Time: 90 % of full scale within 5 seconds Measuring Method: Zirconia oxide sensor Flue Gas Temp. Range: Type R - 600 to 1400 C* / 1112 to 2552 F* Type K - 600 to 900 C /1112 to 1652 F Probe Lengths Options: 0.6 or 1.0 m/ 24 or 40 inch Weight: 2.5 kg (600 mm probe) - 5.51 lb (23.6 " probe) 2.8 kg (1000 mm probe) - 6.2 lb (39.4 " probe) Operating Temperature: -10 C to +80 C / 14 F to 176 F *Reduced probe life may result if operated above 1250 C / 2282 F g1200 Probe Control Unit/g1220 Universal Control Unit Display Type: Parameters: Single-line 4 digit LED O 2 concentration; Calibration Gas Concentration; Cell Temperature; Fault Messages; Cell/Thermocouple Information Analog Outputs: Single channel isolated 0 to 10; 0 to 20; 2 to 20; 4 to 20mA menu selectable Ranges: Selectable range 0 to 5; 0 to 25% v/v O 2 Serial Output: RS485 Modbus protocol (2-wire, half-duplex) Alarm Relays: Single pole changeover 7A at 30 V d.c./250 V a.c. Alarms: High/Low customer selectable; System Fault; Maintenance/Cal. in Progress Fault Indication: LED indication and error codes Calibration: Option to track or hold Calibration Types: Manual; *Automatic; *Remote Trig. Power Supply: 85 to 264 V a.c.; 48 to 62 Hz Power Rating: 250 W *Requires optional Automatic Calibration Gas Control Unit Compatibility: All Genesis type probes Other zirconia type oxygen probes Max. Distance to Probe: 300 m/ 985 ft EMC: Conforms to EN 50 081, EN 50 082 Safety: Conforms to EN61010-1 Weight: (g1220) 2.7 kg/5.95 lb Operating Temperature: -20 C to +70 C / -4 F to 158 F Continuous product development may make it necessary to change these details without notice 115/4.53 Industries Bio-fuel Boilers Package Boilers Power Generation CCGT Petrochemicals Process Industries Pharmaceuticals Incineration Furnaces g1200 Probe g1210 Probe g1230 Probe 125.5/4.94 126/5 125/4.92 g1220 Control Unit 126/5 475/18.7 400/15.8 255/10 0.4 m/1.3 ft 200/7.9 0.4 m/1.3 ft 62/2.5 122/4.80 556 or 953/ 5/0.2 21.9 or 37.5 7/0.28 ø62/2.5 ø62/2.5 ø62/2.5 All dimensions are given in mm/inches except where stated ø62/2.4 1.0/1.5/2.0 m 3.3/4.9/6.6 ft 1.0/1.5/2.0 m 3.3/4.9/6.6 ft 131/5.1 27.5/1.08

Further Information UK Land Instruments International Ltd Dronfield, Derbyshire, S18 1DJ Tel: +44 (0) 1246 417691 Supplied & serviced by : Fax: +44 (0) 1246 290274 E-Mail:combustion.info@landinst.com Web: www.landinst.com Q Instrument Services Limited, Cork. USA Ametek LAND, Inc. 10 Friends Lane Phone : 086-8129925 Newtown, PA 18940-1804 Tel: +1 215 504 8000 Fax: +1 215 504 0879 Fax : 021-4341218 E-Mail:combsales@landinstruments.net Web: www.landinstruments.net Email : info@qlimited.com Poland Land Instruments Sp z o.o. www.qlimited.com ul. Michalowskiego 5/2 31-126 Krakow Tel: +48 (0) 12 632 82 62 Fax: +48 (0) 12 632 24 74 E-Mail:land@land.com.pl Web: www.land.com.pl Italy Land Instruments SRL Via dell Industria, 2 20037 Paderno Dugnano MI Tel: +39 02 9904 0423, 9108 0020 Fax: +39 02 99 04 0418 E-Mail: comb.info@landinst.it Web: www.landinst.it France Land Instruments Sarl 7 Parc des Fontenelles 78870 Bailly Tel: +33 (0) 1 30 80 89 20 Fax: +33 (0) 1 30 80 89 21 E-Mail: info-combustion@landinst.fr Accessories g1270 Automatic Calibration Unit To help with compliance, as well as reducing maintenance and increasing accuracy, this unit automatically controls the calibration gas (both zero and span) to the Genesis probe at programmed intervals. The g1270 functions are controlled (as with the probe) by the control unit. Specifications Genesis g1270 Automatic Calibration Unit Dimensions: 300x200x155 mm/11.8x7.9x6.1 in (HxWxD) Weight: 6 kg/13.2 lb Operating Temp: 0 to 50 C/32 to 122 F Enclosure Rating: IP65/NEMA4 Power Supply: 110 V or 240 V a.c. 50-60 Hz 10 VA Supply Tolerance: -10 % +20 % Gas Inlet Pressure: 1.7 to 2.0 bar/25-30 psi Gas Outlet Flow: 3.0 litres/min. for g1200 & g1210 0.8 to 1.0 litres/min. for g1230 Pressure Switch: 1 bar/15 psi trip pressure Slave Relays: 2- galvanically isolated changeover contacts Continuous product development may make it necessary to change these details without notice Reference Air Supply Units To achieve the best measurement performance it is essential that reference air with 20.9 % Oxygen is present at the measurement cell. Land have two options for providing reference air: an air regulator system or an electric air pump. Mexico Land Instruments International Av. Horacia 1132 Planta Baja B Col. Polanco 11550 MEXICO D.F. Tel + 52 55 5281 1165 Fax + 52 55 5281 5364 E-Mail:ventas@landinstruments.net www.landinst.com Land has a comprehensive range of Combustion and Environmental Monitoring Instrumentation. An Company TÜV approved Copyright 2000-2006 Land Instruments International Approval applies to products designed and manufactured in the UK Approval applies in the USA PDS181/08/06