Circulating Lubrication Systems (Oil)

Similar documents
Circulating Lubrication Systems (Oil)

Oil+Air Systems. for the lubrication of spindles, linear guides, rack pinions. Functional principle and application

Control Units for Oil+Air Lubrication

Accessories for Progressive Systems

for the lubrication of spindles, linear guides, rack pinions, chains, assembly processes

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Fixed Displacement Pump KFA for commercial vehicles in open circuits

OWNER S TECHNICAL MANUAL

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Controllers DR, DP, FR and DFR

Hand lever valves VHER

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Self-operated Pressure Regulators for special applications

Pressure and Flow Control Valves DBGM, German and European Patents

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

HERZ-Motorised flow controler

Old documentation - Only for your information! Product is not available anymore!

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

4/2 way Pneumatic Solenoid Valve

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Air service units series K G1/8, G1/4

Air preparation units

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Technical Data Sheet TI-F50 Locking Units series KFH

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

Type 4708 Supply Pressure Regulator

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Pressure reducing valve, pilot operated, Model 3DR

Fixed Displacement Motor A4FM

PLD 03 T A CASAPPA S.p.A.

ALF400 to 900, ALT-5/-9

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Operating and maintenance manual Filter and reducing station Series / 1.0

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Flow control valves Series RFU - RFO 2/

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Series K Air service units G 1/8, G 1/4

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Type 4708 Supply Pressure Regulator

Pressure Relief Valves. SPV, SPVF direct operated

Product Sheet Spraymist Unit

Mass Flow Meter (MFM) for Gases

Description Pressure range Connection thread Device Page

The number of test stands can be adapted to the special requirements.

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Pressure-controlled shut-off valve type CNE

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

WATER PRESSURE REDUCER (SBD)

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Installation, Operation and Maintenance Manual for Back Pressure Regulator

VACUUM REGULATORS CONTENTS

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Fixed Displacement Plug-In Motor A2FE

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure Reducing Valve DMV 755

ALF400 to 900, ALT-5/-9

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

F l o w c o n T R o l v a l v E S

GM Series Dual-Block Multi-Function Gas Control Valves

Pressure reducing valve, pilot operated

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

ALF400 to 900, ALT-5/-9

Installation and commissioning instructions 255 series and 256 series

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Pressure Relief Valve DHV 718

PRO SINK -R 1 and 2. Dilution system CONTENTS

Spare parts list ( ) Spare parts list HDS 990

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Fixed Displacement Motor A4FM

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Full-Vacuum Chlorinator C 2212 MB / 1

PVQ 13 A2 R SE 1 S 20 C-11 D

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

TF- & DM-Series. Turbineflowmeter

Pressure Reducing Valve DMV 750 set range: bar

Spare parts list ( ) Spare parts list HD 1090 WS *

Two-stage valve type NE

D62 - D63 Directional Control Valve l/min

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

VB85/ Pressure regulating valve (Unloader)

Transcription:

Circulating Lubrication Systems (Oil) 1-5006-US Screw-in Restrictors, Metering Valve Distributors, Flow Volume Dividers Screw-in restrictor Metering valve distributor Flow volume divider SP/SMT (cf. 1-5017-US) A continuous flow oil is often necessary for the lubrication or cooling of machines or systems requiring large amounts of oil. This flow is produced by gear, gerotor, vane and piston pumps and then distributed to meet the needs of the individual lube points. The system is very simple if there is only one lube point to be supplied. But if the lubricant is to be delivered to a of lube points in equal quantities or certain proportions, there are several possibilities entailing different expenses and effects. If must be remembered that circulating lubrication systems require an oil return line from the lube points to the oil reservoir. Adequate filtering of the oil must be provided for. Restrictors, especially for small amounts of oil, are sensitive to dirt. Layout of a circulating lubrication system (printing machine) with progressive feeders MQUALITY MANAGE www.vogelag.com ENT

Circulating Lubrication Systems (Oil) 1-5006-US 2 Distribution systems System description 1a Restrictor tubes 1b Screw-in restrictors and adjust. metering valve distributors A pump supplies a network of lines connected to all the lube points via manifolds and branch lines. The quantity is apportioned in inverse proportion to the resistance of the restrictor tubes, screw-in restrictors or metering valve distributors. Screw-in restrictors can be installed on manifolds (cf. leaflet 1-0103-US or screwed directly into the threads of the lube points. 1 1c 1c Flow monitors with choke System similar to 1b, but the interchangeable metering valve is installed upstream of a flow monitor in which an electrical contact is actuated by a piston moved by the oil flow. The contact returns to its neutral position when there is oil pressure without a simultaneous flow of oil. See leaflet 1-1704-US Progressive feeders 2 The flow from the pump is divided up by a feeder. The flow from this master feeder can be further divided up for up to a total of some 100 lube points by way of downstream progressive feeders. See leaflet 1-0107-1-US 3 Multi-circuit pumps Multi-circuit pumps (e.g. 2, 4, 5, 8, 10, 20 zones) supply the lube points direct with prespecified quantities of oil that correspond to the pumps' delivery rates. It is possible to work with or without priming pressure, depending on the operating pressures and accuracy requirements to be expected. Subdistribution of the individual zones is possible in accordance with systems 1 and 2. See leaflet 1-1204-US Auxiliary equipment for systems 1a and 1b is specified in this leaflet. Flow volume divider, type SP/SMT for circulating lubrication systems (oil) cf. leaflet 1-5017-US.

Circulating Lubrication Systems (Oil) 1-5006-US 3 Volumetric flow per lube point Permissible operating pressure [bars] Max. of lubrication points Monitoring General remarks and criteria 1a a few ccm to several l/min Screw-in restrictors: 0.2-230 ccm/min Metering valve distributors 0-2000 ccm/min 2-20 2-20 0-10 Unlimited in practice. Tubing cross sections and pump have to be adapted. No monitoring of individual points, pressure can only be monitored in the main line. For an even distribution of oil provide for the most symmetric layout possible. Lay tubing with the largest possible cross sections from the pump to the junctions. When individual points require different amounts of oil, change the lengths or cross sections of the restrictor tubes to obtain the respectively needed quantity. Inexpensive, reliable, insensitive to dirt. Planning is complicated when extensive, asymmetric systems with different oil needs are involved. 1b 1c Restrictors can clog up when unfiltered oil is used. It is therefore necessary to install a microfilter upstream in the systems, preferably with a dirt indicator. Planning and quantity regulation easy. The pressure losses in the tubing have to be taken into account when the system is designed. 0.05-14 l/min 5-25 Oil flow is monitored. An alarm is triggered if the flow drops below the bottom limit of the range for the flow monitor selected. 1a 1b 1c Metering imprecise with fluctuating and varying back pressures. Often of no importance in circulating lubrication systems not used for cooling purposes at the same time. The systems do not depend on the viscosity. a few ccm to 1 l/min 5-200 Pressure should not exceed 100 bars in circulating lubrication systems. 2 to roughly 100 Central monitoring of functions of all distributors easy since system-related. Pulsating oil current. Very exact apportioning of quantities, even with back pressures. Planning complicated, especially changes at a later date. The systems depend on the viscosity. Easy to plan. 0.015-1.2 l/min per outlet 20 or 80 depending on pump 2, 4, 5, 8, 10, 20 zones per pump Monitoring of one or more strings of lines with flow monitors or the like possible. A monitored string of lines already shows the pump is operating and lubricant is available. The lower the pressure difference between the priming pump and distributing pump the more even the delivery rates are in relation to each other.

Circulating Lubrication Systems (Oil) 1-5006-US 4 Screw-in restrictors Screw-in restrictors are used to deliver relatively small amounts of oil to the lube points. The sizes are identified by s. The diagrams show the flow rates of the individual sizes as a function of the pressure and as measured with an operating viscosity of the oil amounting to 140 mm 2 /s. The flow rate varies with the viscosity. Depending on the position of the embossed direction arrow, the restrictors can either be combined (cf. leaflet 1-0103-US) and fitted to manifolds (types A and D) or directly screwed into the ports of the individual lube points (types B and C). Special attention must be paid to the use of clean oil, the recommended filter size being 10 µm. Screw-in restrictors of types C and D additionally contain one check valve each that can help to prevent leaks, for instance. The scope of delivery also covers union nuts and tapered rings when types C or D are ordered. Type A Type B for tube Code Order No. diam. VD1-102 2 VD1-103 3 VD1-104 4 VD1-105 4 5 VD1-106 6 VD1-107 7 VD1-108 8 VD1-109 9 Washer, order No. 504-019 for tube Code Order No. diam. VD2-102 2 VD2-103 3 VD2-104 6 4 VD2-105 5 VD2-109 9 Washer, order No. 504-019 flow rate [ccm/min] 30 20 10 5 4 3 2 Durchflussmenge [cm 3 /min] 0 0 1 2 3 4 5 6 1 2 3 4 5 6 pressure [bars] pressure [bars] 250 200 150 100 50 9 8 7 6 Port tapped for solderless tube connection. SW = width across flats Type C Type D 3 2 for tube Code Order No. diam. VD3-099 00 VD3-100 4 0 VD3-101 1 VD3-102 2 Tube connection acc. to DIN 2353 for tube Code Order No. diam. VD4-099 4 00 VD4-100 0 Washer, order No. DIN7603-A8x11.5-CU flow rate [ccm/min] 2 1 1 0 00 0 1 2 3 4 5 6 pressure [bars]

Circulating Lubrication Systems (Oil) 1-5006-US 5 Connecting piece with restrictor (complete with washer) Code No. Code No. Nomograph for determination of restrictor size for tube Connection Code Order No. diam. thread 1 ) No. GD60 60 GD61 61 GD62 62 4 M12x1.5 GD63 63 GD64 64 GD65 65 GD80 80 GD81 81 GD82 82 GD83 83 GD84 84 6 M14x1.5 GD85 85 GD86 86 GD87 87 GD88 88 GD89 89 1) Ports tapped for solderless tube connection to DIN 2353 (cutting sleeve) Determining the restrictor size 1. Draw a straight line along the index lines through point Q eff. 2. Determine the point at which p intersects with this line, resulting in D. 3. Select the restrictor closest to point D. D must be inside the white field, i.e. small amounts cannot be apportioned and monitored with the unit. Operating viscosity ν eff.[mm 2 /s] Lubricant quantity Q [ccm/min] Code No. min. system pressure Pressure p [bars] Example 1 required: Q = 36 ccm/min, given: ν eff = 280 mm 2 /s, p = 7 bars Result: restrictor size No. 60 (borderline case) Example 2 required : Q = 260 ccm/min, given : ν eff = 480 mm 2 /s, p = 8 bars Result: restrictor size No. 80 Operating viscosity ν eff.[mm 2 /s] Lubricant quantity Q [ccm/min] min. system pressure Pressure p [bars]

Circulating Lubrication Systems (Oil) 1-5006-US 6 Metering valve distributors These metering valve distributors are used If an infinitely variable adjustment of the flow rate per lube point is required even at a later date. In the case of type A for flow rates within the drop-feed range knurled lock nuts and knurled screws are provided for adjustment purposes. It is necessary to provide for a sufficiently large drain-off in order to maintain a free fall of drops in the sight glass. In the case of types B and C, the continuous flow rate is adjusted after the upper hexagonal lock nut is loosened. Spring-loaded metal pins in sight glasses indicate that oil is flowing when they move away from the mark. B spacer Characteristic values of the metering valve distributors operating pressure............... 10 bars viscosity range.......... 10 to 1000 mm 2 /s temperature range............ 0 to +60 C mounting position.............. as shown Output range type A................. 0 to 10 ccm/min type B............... 10 to 1000 ccm/min type C.............. 10 to 2000 ccm/min Indicating range for types B and C at 110 mm 2 /s commencement of indication... at 10 ccm/min end of indication.... at 1000 or 2000 ccm/min Number of Dimensions in mm Order No. lube points l1 l2 l3 242-024.00 2 49 17 242-034.00 3 66 17 34 242-044.00 4 83 34 51 242-054.00 5 100 51 68 242-064.00 6 117 68 85 242-104.00 10 185 136 153 242-124.00 12 219 170 187 Adapter for main tube: 6 mm diam. tube, order No. 406-162 8 mm diam. tube, order No. 408-162 10 mm diam. tube, order No. 410-162 Screw plug, order No. 408-211 Washer, order No. 508-215-CU for 6 mm diam. tube A C spacer spacer for 6 mm diam. tube for 10 mm diam. tube Number of Dimensions in mm Order No. lube points l1 l2 l3 242-016.00 1 32 242-026.00 2 49 17 242-056.00 5 100 51 68 242-146.00 14 253 204 221 Adapter for main tube: 6 mm diam. tube, order No. 406-162 8 mm diam. tube, order No. 408-162 10 mm diam. tube, order No. 410-162 Screw plug, order No. 408-211 Washer, order No. 508-215-CU Number of Dimensions in mm Order No. lube points l1 l2 l3 242-025.00 2 66 23 242-035.00 3 89 23 46 242-045.00 4 112 46 69 242-055.00 5 135 69 92 242-065.00 6 158 92 115 Adapter for main tube: 10 mm diam. tube, order 410-018 12 mm diam. tube, order 412-004 Screw plug, order No. 412-011 Washer, order No. DIN7603-A18x22-CU 1) Ports tapped for solderless tube connection

Circulating Lubrication Systems (Oil) 1-5006-US 7

Willy Vogel AG Motzener Strasse 35/37 12277 Berlin, Germany P.O.Box 970444 12704 Berlin Tel. +49 (0) 30-7 20 02-0 Fax +49 (0) 30-7 20 02-111 info@vogel-berlin.de www.vogelag.com Notice! All products from VOGEL may be used only for their intended purpose. If operating instructions are supplied together with the products, the provisions and information therein of specific relevance to the equipment must be observed as well. In particular, we call your attention to the fact that hazardous materials of any kind, especially the materials classified as hazardous by EC Directive 67/548/EEC, Article 2, Par. 2, may only be filled into VOGEL central lubrication systems and components and delivered and/or distributed with the same after consultation with and written approval from VOGEL. All products manufactured by VOGEL are not approved for use in conjunction with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1013 mbars) by more than 0.5 bar at their maximum permissible temperature. Willy Vogel AG 2. Industriestrasse 4 68766 Hockenheim Germany Tel. +49 (0) 62 05-27-0 Fax +49 (0) 62 05-27-132 info@vogel-berlin.de www.vogelag.com Vogel France SAS Rue Robert Amy, B.P. 130 49404 Saumur cedex France Tel. +33 (0) 241 404 200 Fax +33 (0) 241 404 242 info@vogelfrance.com www.vogelfrance.com Subject to change without notice! 0000 03/2003