Constant Pressure Inlet (CCN) Operator Manual

Similar documents
INSTALLATION & MAINTENANCE INSTRUCTIONS

Cloud Condensation Nuclei (CCN) Counter

DPC-30 DPC-100. Reference Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

PS-425 Pitot-Static/Air Data Tester

DOC-0087 Rev B (DOC-0086 CCN Operators Manual)

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Model 130M Pneumatic Controller

Columbus Instruments

Digital Vacuum Regulator

Cover Page for Lab Report Group Portion. Pump Performance

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

Digital Vacuum Regulator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

HumiSys HF High Flow RH Generator

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

THE INSIDE STORY OF THE F-SERIES:

Chlorinator MODEL MK-I

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Miniature Electronic Pressure Controllers. Precision Fluidics

Instruction and Maintenance Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

! Warning, refer to accompanying documents.

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

1811G/H PITOT-STATIC TEST SET

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

RD(H)20/25 Pressure-Reducing Regulator User Manual

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Operating Manual. Model BAC-30RT30/BAC-30DC

QBS Electronic Pressure Regulator

T EK-SUB 4800C 19 mm Submersible Level Transmitter

The Ins and Outs of I/P Transducers

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

RAM 4021-DPX Operation Manual

Digital Vacuum Regulator

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

VACCUPERM Vacuum chlorine gas dosing systems

CAPITAL CONTROLS SERIES NXT3000

deltaflowc deltaflowc Venturi or Probe

Overview. Front Panel: Keypad and Display

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Installation and Operation Manual

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction Manual Model Borehole Pressure Cell

Marschalk Model # 94000

P06 & P012 Pitot-Static Probes

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

P8 to P60 Pitot-Static Probes

Model Description

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Model PDT Dewpoint Transmitter

RC 195 Receiver-Controller

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Instruction and Maintenance Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

INSTALLATION GUIDE Gas Rangetops

Pressure Independent Control Series

VACUUM REGULATORS CONTENTS

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

OPERATING INSTRUCTIONS

Laboratory Experiments No 1: Measuring the Number Distribution

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

User s Guide. Vacuum Controller for liquid delivery systems

INSTALLATION & MAINTENANCE INSTRUCTIONS QBX ETHERNET MODEL

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Agilent Auxiliary Gas Module AGM 2. User s Guide

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Long term stability tests of INO RPC prototypes

High-performance submersible pressure transmitter For level measurement Model LH-10

Manual Solvent Purification System. Innovative Technology, Inc.

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

User s Guide Temperature Sensor Converter TSC-599

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

RAM Operation Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Instruction Manual BA90 Precision Barometer

MPC1-D-1000/MPC1-D-3000 Manual Pressure Controller for Differential Pressure User s Manual

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I N C.

Copyright 2011 Droplet Measurement Technologies, Inc. 2545 CENTRAL AVENUE BOULDER, COLORADO, USA 80301-5727 TEL: +1 (303) 440-5576 FAX: +1 (303) 440-1965 WWW.DROPLETMEASUREMENT.COM All rights reserved. No part of this document shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Droplet Measurement Technologies, Inc. Although every precaution has been taken in the preparation of this document, Droplet Measurement Technologies, Inc. assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. Information in this document is subject to change without prior notice in order to improve accuracy, design, and function and does not represent a commitment on the part of the manufacturer. Information furnished in this manual is believed to be accurate and reliable. However, no responsibility is assumed for its use, or any infringements of patents or other rights of third parties, which may result from its use. Trademark Information All Droplet Measurement Technologies, Inc. product names and the Droplet Measurement Technologies, Inc. logo are trademarks of Droplet Measurement Technologies, Inc. All other brands and product names are trademarks or registered trademarks of their respective owners. Warranty The seller warrants that the equipment supplied will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase of the original buyer. The probe owner will pay for shipping to DMT, while DMT covers the return shipping expense. Consumable components, such as tubing, filters, pump diaphragms and Nafion humidifier are not covered by this warranty. DOC-0125 Rev J ii

C O N T E N T S 1.0 Introduction... 4 2.0 Theory of Operation... 4 3.0 Pre-Flight Set-up... 8 4.0 Concentration and Supersaturation Corrections... 10 Appendix A: Revisions to Manual... 11 Appendix B: Suggested Orifice Size for Specific Altitudes... 12 Appendix C: Schematic... 13 Appendix D: Wiring Diagram... 14 Appendix E: CCN Aircraft Inlet... 15 F i g u r e s Figure 1: Block Diagram of the Inlet Pressure Control Flow System... 5 Figure 2: Control Panel, Pressure Control Unit... 6 Figure 3: Inlet Tubing and T Attached to CCN-100 Inlet... 7 Figure 4: Inlet Tubing and T Attached to CCN-200 Inlet... 8 DOC-0125 Rev J 3

1.0 Introduction The supersaturation in the thermal gradient CCN counter can be disturbed by changes in pressure in the column. There is a slight influence of the column internal pressure on the supersaturation under stable conditions (Roberts and Nenes, Aerosol Science and Technology, 39, 206-221, 2005). With rapid changes in pressure, when an aircraft ascends or descends, the supersaturation in the column will drop and the CCN measurements will not be reliable until the pressure has stabilized. The CCN constant pressure inlet accessory provides constant pressure at the inlet of the CCN when the CCN is operated from an aircraft platform. A hose clamp pinching the inlet conductive tubing is used to provide a pressure drop, and the Inlet Pressure Controller provides a variable vacuum to maintain a constant pressure in the CCN instrument. The following details the specifications of the constant pressure inlet system: Power: Size: Weight: External Signals: 28 VDC, 2 A 30 cm long, 12 cm high, 20 cm wide 2.3 kg Valve voltage, system pressure 2.0 Theory of Operation The Inlet Pressure Controller (IPC) accessory for operating the CCN on an aircraft has been designed to reduce the pressure in the inlet manifold and operate the CCN at a constant reduced pressure. Figure 1 shows the schematic diagram of CCN inlet pressure controller installed in an aircraft environment in conjunction with a CCN counter. An Orifice on the conductive tubing at the inlet serves to reduce the pressure and the pressure control unit provides a vacuum in addition to that provided by the CCN counter. An analog feedback loop is used between the set point given by the potentiometer on the front of the control box and the pressure transducer. Appendix B shows the suggested orifice to use for a particular altitude. For instance, if 14,000 is the maximum expected altitude, the 0.20 orifice should be used. If flying at 15,000 or higher, the 0.017 diameter orifice should be used. DOC-0125 Rev J 4

From Aircraft Inlet Water Trap T Black Conductive Tubing Inlet CCN Orifice (select proper size) Outlet Absolute Pressure Sensor Poly Inlet Pump Poly Electronic Proportional Control Valve Constant Pressure Inlet Outlet T Exhaust Overboard Figure 1: Block Diagram of the Inlet Pressure Control Flow System DOC-0125 Rev J 5

Figure 2 shows the control panel on the front of the pressure control unit. A twoposition switch controls the readout of the panel meter. In the down position, the meter will read the control voltage to the proportional valve. In the up position, the panel meter readout will give the manifold pressure set-point in mb. The back panel of the IPC has BNC jacks for connection of the pressure readout and the valve voltage to an auxiliary data system, if desired. This connection is not part of the DMT standard PADS data system package. Figure 2: Control Panel, Pressure Control Unit The pressure drop to the inlet of the CCN is accomplished with an orifice on the black conductive tubing that is supplied with the inlet pressure controller. Figure 3 shows a typical inlet assembly connected to a CCN instrument DOC-0125 Rev J 6

Orifice From Aircraft Inlet To Pressure control inlet Figure 3: Inlet Tubing and T Attached to CCN-100 Inlet DOC-0125 Rev J 7

Figure 4: Inlet Tubing and T Attached to CCN-200 Inlet 3.0 Pre-Flight Set-up Setting the inlet manifold set-point involves selecting the correct orifice size..017 and.020 are provided. The minimum pressure in the inlet should correspond very closely to the maximum altitude expected for the aircraft. Appendix B gives a table of altitude (in feet) and standard atmospheric pressure. The true atmospheric pressure at any altitude will vary according to meteorological conditions and a pressure slightly lower than the lowest expected pressure should be chosen. 1. Install the CCN inlet pressure controller as shown in Figures 1 and 3 on the CCN. 2. Select the control pressure for the maximum altitude that measurements will be made from Appendix B. 3. Install.020 orifice into ¼ conductive tubing 4. Start the CCN counter DOC-0125 Rev J 8

5. Turn on the PUMP POWER and the SYSTEM POWER switches on the CCN inlet pressure control box. 6. Perform leak check of entire CCN/Constant pressure inlet plumbing a. Install Plug on inlet from aircraft, You can gently pinch the black conductive tubing or disconnect it from fitting to outside air and install plug b. Monitor inlet pressure, It should drop quickly and go below 400mb c. Turn off Pumps on CCN and Constant pressure inlet. d. Wait 30 seconds and verify leak rate is less than 5mb per second. e. If leak rate is more than 5mb sec, leak must be located and fixed before valid data will be attained. 7. Set the PRESSURE SET potentiometer on the front of the CCN inlet pressure control box to the pressure as determined in step 2. 8. Select Manifold pressure with the switch on the front panel 9. Verify that the manifold pressure is able to reach the desired pressure set by potentiometer in step 6. 10. If manifold pressure cannot reach set point, install the smaller size orifice and repeat steps. 11. If during flight the manifold pressure is not stable, a different orifice size may be needed. Contact DMT for further assistance It may be necessary to reset the sheath/sample flow ratio at the reduced pressure for the CCN. NOTE: This setup may not be able to keep the inlet pressure constant when flying at high altitudes. An orifice for low altitude and one for high altitude may be required to get the dynamic range. Contact DMT for further assistance. DOC-0125 Rev J 9

4.0 Concentration and Supersaturation Corrections Operating the CCN at constant pressure will affect the particle concentration. If the CCN pressure is reading 500 mb, and the ambient pressure is 500 mb, no correction to the CCN concentration is needed. If the pressure in the manifold is 500 mb, the aircraft is flying at a pressure altitude of 750 mb, and the CCN concentration is reading at 1000 particles/cc, the true concentration needs to be corrected by 750/500, or a factor of 1.5. The true particle concentration is then 1500 particles/cc. Using the constant pressure inlet system will require external recording of the ambient static pressure and post processing correction of the CCN concentration. There may be slight differences between the pressure measured using the pressure transducer in the CCN instrument and that measured by the IPC. The most accurate data will be obtained by using the pressure ratio based on the measurement in the CCN counter. The CCN is calibrated at ambient pressure in Boulder, Colorado, nominally 830 mb. DMT tests in our laboratory showed that the supersaturation will drop approximately 0.035% for each 100 mb change in pressure. You may want adjust your SS% appropriately to get your desired SS%. The CCN instrument does not automatically make adjustments for pressure. DOC-0125 Rev J 10

Appendix A: Revisions to Manual Rev. Date Rev No. Summary Section 3-11-10 H Reformatted manual Changed supersaturation drop relative to pressure change from 0.07 to 0.035% for each 100 mb 9-7-10 I Corrected example showing maximum expected altitude and corresponding orifice size 5-18-11 J Added photo of Constant Pressure Inlet attached to CCN-200 All sections 4.0 2.0 2.0 DOC-0125 Rev J 11

Appendix B: Suggested Orifice Size for Specific Altitudes Altitude (ft) Meter Standard Pressure (mb) Orifice Size for maximum altitude 0000 0000 1013.020 1000 305 977.020 2000 610 942.020 3000 915 908.020 4000 1219 875.020 5000 1524 843.020 6000 1829 812.020 7000 2134 782.020 8000 2438 753.020 9000 2743 724.020 10000 3048 697.020 11000 3353 670.020 12000 3658 644.020 13000 3962 619.020 14000 4267 595.020 15000 4572 572.017 16000 4877 549.017 17000 5182 527.017 18000 5486 506.017 19000 5791 485.017 20000 6096 466.017 DOC-0125 Rev J 12

Appendix C: Schematic DOC-0125 Rev J 13

Appendix D: Wiring Diagram DOC-0125 Rev J 14

Appendix E: CCN Aircraft Inlet DOC-0125 Rev J 15

DOC-0125 Rev J 16

DOC-0125 Rev J 17