Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Similar documents
Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Ultima. X Series Gas Monitor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

HART Communications Board

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Hydro-Control V User Guide

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

How to specify a product. Process Sensors and Mechanical Instruments

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Device Description User Manual Logix 520MD Positioners

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Differential Pressure Transmiter

Installation and Operation Manual

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

DTG - LCD Digital Temperature Gauge USER MANUAL

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Safety Manual VEGAVIB series 60

Description of Device Parameters Proline Prowirl 200 HART. Vortex flowmeter. Products Solutions Services. Main menu Language.

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

BAPI Pressure Line of Products - FAQs

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

Datasheet: K-30 ASCII Sensor

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Model EXAxt AV550G. Averaging Oxygen Analyzer

Safety Manual VEGAVIB series 60

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Pneumatic high-pressure controller Model CPC7000

GasSense NDIR User Manual

RAM Operation Manual

AMS 6916 Board mount pressure sensor with ratiometric analog output

Special Documentation Proline Promass 80, 83

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

ACV-10 Automatic Control Valve

Vehicle- or rack-mounted liquefied gas meters, pump supplied

AMT-Ex Dewpoint Transmitter

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

For Multi-Parameter Meters see mvx

BUBBLER CONTROL SYSTEM

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Vehicle-mounted meters, pump supplied

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Scoreboard Operator s Instructions MPC Control

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

For Multi-Parameter Meters see mvx

Design Envelope Booster. Sequence of operation

Instruction Manual. BZ7002 Calibration Software BE

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

RAM 4021-DPX Operation Manual

Electronic gas volume corrector model DGVC-04

PTG100 Precision Test Gauge

86BSD Backside Digital Output

Features. Description

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

BUYER S GUIDE AQUAlogger 530WTD

G200 Analyzer Range. Operating Manual

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Location of CC Number if not located with the identification:

WHITEPAPER. Integrated process monitoring of dosing pressures

sitrans p Instruction Manual Edition 10/2003

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

Pneumatic high-pressure controller Model CPC7000

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

REASONS FOR THE DEVELOPMENT

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Instruction Manual Dräger MSI P7 and MSI P7 plus

A4s Operation Manual

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

PRODUCT CONFORMITY CERTIFICATE

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

4000 series (includes 4100, 4200 & 4900)

G200 RANGE G200 AND G210 OPERATING MANUAL

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

BUBBLER CONTROL SYSTEM

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

HEATEC TEC-NOTE Publication No Revised

Additel761 Series Firmware Updates

Transmitter CS 21 Operation Manual

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Programmable Submersible Level Transmitters

AHE58/59 AC Servo System

780S Ultra High Purity Series

Transcription:

www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp

LD302 - AssetView HMI LD302 - ASSETVIEW HMI LD302 Home Page This manual describes the pages developed for LD302 maintenance using AssetView. The figure below shows the LD302 initial page and its options: Figure 1. LD302 Home Page The following sub-sections will describe each one of the pages developed for the device maintenance. 3

User s Manual LD302 Identification Page This page displays relevant information to the pressure transmitter. The user can easily identify and specify the transmitter in the physical plant. Figure 2. Identification Page Device TAG DEVICE TYPE DEVICE SERIAL NUMBER DEVICE REVISION HARDWARE REVISION DEVICE ID MANUFACTURER MAIN BOARD SERIAL NUMBER FIRMWARE REVISION DD REVISION ORDERING CODE Indicates the tag associated to the transmitter in the physical plant. The tag can have up to 32 characters. Identifies the transmitter type for a specific manufacturer. Indicates the transmitter serial number. Indicates the transmitter revision. Indicates the transmitter hardware revision. Indicates the transmitter identification code. This code can have up to 32 characters. Identifies the transmitter manufacturer. Indicates the serial number of the transmitter main board. Indicates the transmitter firmware revision. Indicates the DD revision. Indicates the transmitter ordering code. Sensor SENSOR TYPE SENSOR FLUID SENSOR RANGE CODE SENSOR ISOLATION MATERIAL SENSOR SERIAL NUMBER Indicates the transmitter sensor type. Indicates the fluid of the transmitter s sensor. Indicates the range code of the transmitter s sensor. Indicates the sensor isolation material. Indicates the transmitter sensor serial number. 4

LD302 - AssetView HMI Flange FLANGE TYPE FLANGE MATERIAL DRAIN/VENT MATERIAL O-RING MATERIAL Indicates the flange type. Indicates the flange material. Indicates the drain/vent material. Indicates the o-ring material. Remote Seal NUMBER OF REMOTE SEALS REMOTE SEAL TYPE REMOTE SEAL FLUID REMOTE SEAL ISOLATION MATERIAL Indicates the number of remote seals. Indicates the remote seal type. Indicates the remote seal fluid. Indicates the remote seal isolation material. LD302 Configuration Page There are some parameters in the LD302 transducer block that can be used in the predictive and proactive maintenance. It is possible to detect the performance decreasing by comparing the current parameters with the standard values and then schedule the maintenance. The user can check the general status diagnostic in the LD302 Diagnostic Page (refer to the next section). This status is generated according to the user configuration in the LD302 Configuration Page. For example, the Sensor Failure diagnostic may be caused by an overpressure in the sensor. Figure 3. Configuration Page 5

User s Manual Device Operation Mode Indicates the operation mode for the device: OOS AUTO MAN If this mode is selected, the value of the Mode Block parameter will be Out of Service for the Resource, Transducer and Analog Output blocks. If this mode is selected, the value of the Mode Block parameter will be Auto for the Resource, Transducer, Display and Analog Output blocks. If this mode is selected, the value of the Mode Block parameter will be Manual for the Analog Output block, and Auto for the Resource, Transducer and Display blocks. Measured Type Select the type of the measured variable: LEVEL PRESSURE FLOW Indicates the transmitter is measuring level. Indicates the transmitter is measuring pressure. Indicates the transmitter is measuring flow. Measurement Configuration AUTO ZERO CHARACTERIZATION FUNCTION LOW CUT OFF Enables and disables the zero cutoff. Enables and disables the pressure characterization curve. Indicates the function that acts in the Primary Value: Linear or Table. Indicates the value of the pressure cutoff. If the pressure value is lower than the value indicated by Low Cut Off, zero ( 0 ) will be displayed. Engineering Variable UNIT Engineering unit. 0% Value of the pressure corresponding to 0%, in EU. 100% Value of the pressure corresponding to 100%, in EU. Process Variable UNIT LOWER RANGE UPPER RANGE Unit of the process variable. Lower limit of the process variable. Upper limit of the process variable. Alert Configuration MAXIMUM OFFSET DEVIATION OVERPRESSURE LIMIT MAXIMUM GAIN DEVIATION MAXIMUM NUMBER OF OVERPRESSURE Indicates the maximum offset deviation before an alarm is generated. Defines the maximum overpressure limit before an alarm is generated. Defines the maximum gain before an alarm is generated. Defines the maximum number of overpressure before an alarm is generated. 6

LD302 - AssetView HMI LD302 Diagnostics Page The user can check the general status diagnostic in the LD302 Diagnostic Page. Figure 4. Diagnostic Page Device Status MAXIMUM PRESSURE MEASURED MAXIMUM TEMPERATURE MEASURED CURRENT OFFSET CURRENT SPAN Indicates the maximum pressure measured. Indicates the maximum temperature measured. Indicates the current calibrated offset. Indicates the current calibrated span. Diagnosis This field shows the continuous diagnostic status for the device, including the function block condition, the mechanical module condition and the sensor condition. POWER UP SENSOR FAILURE MEMORY FAILURE OUT OF SERVICE DEVICE NEEDS MAINTENANCE SOON DEVICE NEEDS MAINTENANCE NOW CALIBRATION ERROR Indicates that the device has executed the initial operation procedure. Indicates a failure in the sensor, such as overpressure. Indicates an electronic failure according to the internal checking procedure, such as an incorrect checksum detected in the main memory. Indicates that the function block is out of service. The internal diagnostic according to the user configuration or device internal checking has detected that the device will need maintenance soon. This diagnostic is related to overpressure in the sensor. The internal diagnostic according to the user configuration or device internal checking has detected that the device needs maintenance. This diagnostic is related to the sensor calibration. Indicates that an error occurred during the device calibration, or a calibration error has been detected while operating the device. 7

User s Manual BLOCK CONFIGURATION ERROR DATA INTEGRITY ERROR SOFTWARE ERROR ELECTRONICS FAILURE GENERAL ERROR Indicates that there is an error related to the XD_SCALE parameter in the AI function block. Indicates that data stored in the system may be no longer valid, for example, because the checksum of the data in the RAM memory has failed when compared to the data in the non-volatile memory. The software has detected an error that may have been caused by a deviation of a service routine, an interruption, a lost pointer, etc. An electronic component has failed. A general error related to the device has been detected. LD302 Calibration Page This page displays configuration data used in the calibration procedures. Pressure Calibration Information CALIBRATION UNIT SENSOR LOWER RANGE LIMIT SENSOR UPPER RANGE LIMIT MINIMUM SPAN CURRENT LOW POINT CALIBRATION Figure 5. Calibration Page Indicates the unit for the pressure calibration procedure. Indicates the lower limit for the range s sensor. Indicates the upper limit for the range s sensor. Indicates the minimum value allowed between the lower and upper points of the calibration. Indicates the current lower point of the pressure calibration. 8

LD302 - AssetView HMI CURRENT HIGH POINT CALIBRATION FACTORY LOW POINT CALIBRATION FACTORY HIGH POINT CALIBRATION PRESSURE MEASURED TEMPERATURE MEASURED Indicates the current higher point of the pressure calibration. Indicates the factory s lower point of the pressure calibration. Indicates the factory s higher point of the pressure calibration. Indicates the pressure measured by the device. Indicates the temperature measured by the device. Temperature Calibration Information CALIBRATION UNIT CALIBRATION TEMPERATURE Calibration Methods Indicates the unit for the temperature calibration procedure. Indicates the value of the last temperature calibration. NOTE When the transmitter is installed, it is recommended to run the Lower Pressure Calibration procedure to minimize the mounting. Please refer to the transmitter manual for further details. LOWER PRESSURE CALIBRATION: This method is used when calibrating the lower pressure point. The user can select the calibration unit and type the value of the pressure applied as reference value to the transmitter, observing the sensor limits and the minimum span. When this method is selected, a message appears warning the user that this procedure must be executed when the process stops or the plant control is set to manual. Figure 6. Configuring the Mode Block Click Yes, apply the pressure and wait for the sensor stabilization. Figure 7. Stabilizing the Pressure Click OK and the pressure measured will be shown. Figure 8. Confirming the Value of the Pressure 9

User s Manual If the value is correct, click Yes to conclude this procedure. Otherwise, click No and type the pressure value: Figure 9. New Pressure Value Click OK to apply the new pressure value, and then click Yes to confirm the alteration, as shown in Figure 8. The calibration procedure will be concluded. UPPER PRESSURE CALIBRATION: This method is similar to the Lower Pressure Calibration procedure described above. It is used when calibrating the pressure with the user s reference instead of the manufacturer s reference. Figure 10. Configuring the Mode Block Click Yes, apply the pressure, and wait for the sensor stabilization. Figure 11. Stabilizing the Pressure Click OK and the pressure measured will be shown. Figure 12. Confirming the Value of the Pressure If the value is correct, click Yes to conclude this procedure. Otherwise, click No, and type the pressure value: Figure 13. New Pressure Value 10

LD302 - AssetView HMI Click OK to apply the new pressure value, and then click Yes to confirm the alteration, as shown in Figure 12. The calibration procedure will be concluded. SENSOR CHARACTERIZATION: This method is used to correct the sensor reading in several points. Use an accurate and stable pressure source to guarantee that the accuracy is at least three times better than the transmitter accuracy. Figure 14. Configuring the Mode Block Click Next and wait for the pressure stabilization before performing the trim. The characteristic curve of the sensor can be slightly nonlinear at a certain temperature and for some ranges. This nonlinearity can be corrected by the Characterization Trim. The user can characterize the transmitter with the desired operating range to obtain a better accuracy. The characterization is determined from two up to five points. Apply the pressure to the transmitter and waits the sensor stabilization. Figure 15. Configuring the First Point The pressure measured will be shown. Type the first point value, and click Next Point. Apply pressure to the second point click Next Point, and then, successively up to the last point. Up to five points can be inserted. Click Finish to conclude the procedure. NOTE When more than two and less than five points are used, after insert them, and clicking Next the following figure will appear. In the Curve Y (%) and Curve X (%) tabs only the calibrated points will appear before clicking the Next option. 11

User s Manual Figure 16. Finishing the Points Configuration Type the location when the Sensor Characterization procedure is executed, and click Submit. Click Finish to conclude the procedure. TEMPERATURE CALIBRATION This method is used to calibrate the temperature sensor. Figure 17. Stabilizing the Temperature If the value is correct, click Next. Otherwise, type the correct temperature value, click Submit, wait for the sensor stabilization, and then click Next. The following figure will appear. 12

LD302 - AssetView HMI Figure 18. New Temperature Value Type the location when the Temperature Calibration procedure is executed, and click Submit. Click Finish to conclude the procedure. LD302 Display Page The user can save the data shown in the device's display. Figure 19. Display Page 13

User s Manual Display BLOCK TAG PARAMETER SUB INDEX MNEMONIC INC DEC DECIMAL POINT NUMB ACCESS ALPHA NUM Shows the tags list of the available instantiated blocks. Shows the list of available parameters to be displayed in the LCD for the selected block in the Block Tag option. Indicates the sub-index of the selected parameter. Indicates the mnemonic of the selected parameter in the Parameter option. Indicates the value to be added or subtracted when acting the parameter via local adjustment. Indicates the number of digits after the decimal point that will be shown in the LCD. The user can select the access type of the selected parameter: monitoring or action. Indicates if the alphanumeric field will be used for mnemonic or for value. LD302 Device View Page The user can monitor the device's data opening the Device View page. Figure 20. Device View Page 14