Glasgow City Council EDUCATION SERVICES. Technician Support Service

Similar documents
Glasgow City Council EDUCATION SERVICES. Technician Support Service

Health and Safety Guidance Note No 37

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Bauman Machine Inc. COMPRESSED GAS CYLINDER SAFETY

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

3/8" Dr. Air Butterfly Impact Wrench

Tri-Tech Medical Inc.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Working Environment Safety Assessment

Risk Management Department. Compressed Gas Safety

Types 749B and R130 Changeover Manifolds

Oxygen Usage Best Practice Guide

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

General Precautions for handling compressed gases

Protocol Switchover Station

Process Name Compressed Gas Cylinders Program

36H SERIES Combination Gas Valve

Chemical Injection Technologies Installation/Service Bulletin

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

PURPOSE OF THE POLICY

Model VR6 System. Installation, Operation & Maintenance

Oxygen Dialflow Meter. Instructions for Use

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

Micro Dial-Flowmeter. Instructions for Use

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Installation & Maintenance Manual. Economy Manifold

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

623 Series Dome Load Regulators

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Rejuvenation Instructions

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Pressure Regulators. Operating Instructions. Instrumentation

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

Installation & Maintenance Manual. C2 & C3 Manifolds

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

TOOL BOX 031- SERVICE OF CARTRIDGE EXTINGUISHERS

Manual Actuated Boiler Blowdown Valves

DRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Peninsula Dental Social Enterprise (PDSE)

Pressure Regulator. Instructions for Use

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

GAS STRUT SAFETY INFORMATION

1800C and 1800C-HC Series Service Regulators

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Oxygen Dialflow Meter. Instructions for Use

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

MEGR-1627 Instruction Manual

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Section 35 Brieser Construction SH&E Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

VERTICAL AIR COMPRESSORS

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

GM-7000 Series CE Approved Gas Control Valve

Class 2 Gases Learning Tool

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Compressed Gases and Cryogens

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Operating Instructions and Parts Manual 24529

CS150 CAP STAPLER OWNER S MANUAL

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

13kW Patio Heater. Assembly & User Instructions

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Operator: Save these instructions for future use!

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

1 DRIVE INDUSTRIAL IMPACT WRENCH

INSTALLATION INSTRUCTIONS for Filling and Transfer Kits including 2nd cylinder Connection Hose

ESSENTIAL SAFETY RESOURCES

USE OF RESIDUAL PRESSURE VALVES

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

Management Plan for Compressed Gas

ASSEMBLY & OPERATIONS MANUAL. Straight & Clean Torch Cuts. Every Time.

User Operation Manual and Safety Instructions

Medical Gas Control Panel

Operating instruction

PARTS, SERVICE & REPAIR BULLETIN

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Safety Procedures on Vacating Premises

Leader s Guide ERI Safety Videos

Model Air Caddy Orig TABLE OF CONTENTS

Operator: Save these instructions for future use!

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

Economy Manifold Alert -2. Installation and Maintenance Manual V1.6

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Transcription:

Glasgow City Council EDUCATION SERVICES Technician Support Service Technician Guidance Sheets TGS/10b Use & Inspection of Sulphur Dioxide Gas Cylinder & Associated Issued by Technician Support Service Date June 2015 Objectives: The objective of this Guidance Sheet is to instruct Senior Support Service Technicians and Support Service Technicians (Science) in the annual inspection and safe use of sulphur dioxide gas cylinder and associated regulator Persons responsible: Senior and Support Service Technicians (Science) USE & INSPECTION OF SULPHUR DIOXIDE GAS CYLINDER & ASSOCIATED REGULATOR GUIDANCE SHEET 10b

Sulphur Dioxide Gas Cylinders & s The purpose of this Guidance Sheet is to provide information on the safe use and inspection of sulphur dioxide gas cylinders and associated regulator. Anyone who examines, refurbishes, fills or uses a gas cylinder should be suitably trained and have the necessary skills to carry out their job safely. They should understand the risks associated with gas cylinders and their contents. (HSE Safe Use of Gas Cylinders 2004) The following notes are guidance concerning the handling, storage, and use of gas cylinders and inspection of gas regulators to ensure that they are safe for use. The two main sets of regulations covering gas cylinders/regulators are: The Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2004 The Pressure Equipment Regulations 1999 Control of Substances Hazardous to Health Regulations 2002 The law requires that all gas cylinders, which in the case of Glasgow schools are hired or purchased via a reputable supplier, are examined and tested by the company that supplies the cylinder. Sulphur Dioxide cylinders have a pressure of less than 6 bar and as such SO 2 regulators are not subject to the same 5 year inspection and certification that applies to 2 stage regulators as described in TGS10a. 2

General Inspections Only Support Service Technicians (Science) should carry out and record SO 2 gas cylinder and regulator inspections, this includes fitting and removal of regulator control valves. s Users should carry out and record an external visual examination of the gas regulator control valve 3 times per year. This will determine whether there are obvious signs of physical damage to the casing, coupling and threads. An external visual inspection should also be carried out on each occasion of use. Leak tests should be carried out on the following occasions - Annually After fitting a regulator control valve to the gas cylinder The results of these tests MUST be recorded on the record sheet provided. Please see appendix 1 In addition - Leak tests should be carried out if there is reason to suspect a leak and the results recorded in the additional comments section of the record sheet. The record sheet must be retained by the school for a minimum period of five years and made available to council safety officers and officers of the HSE as requested. Cylinders Gas cylinders, which in the case of Glasgow schools are purchased via a reputable supplier, are examined and tested by the company that supplies the cylinder. Gas should be added to TSS Chemical Inventory within 2 days of receipt. Users should carry out an external visual examination on each occasion of use of gas cylinder to determine whether there is obvious damage. Do not use and arrange special waste uplift as soon as practicable: If mounting threads are damaged If the regulator control valve doesn t seat properly If the cylinder control valve requires greater force than normal to turn on or off the supply Precautions Always double-check that the cylinder / gas is suitable for the intended use Do not use gas cylinders for any other purpose than the transport and storage of gas Do not use excessive force to open or close valves. If this appears necessary, return the cylinder to the supplier Sulphur dioxide cylinders should, at all times, be used in bracket provided, the cylinder should be secured to the bracket for secure storage Hydrocarbon Contamination Do not use oil, grease or other hydrocarbon substances on the cylinder valves for lubrication. If any cylinders do accidentally become contaminated, they should not be used but set aside and clearly labelled for special waste uplift SO2 cylinders gifted to the school must never be used 3

Storage Entry door(s) to storage area(s) must display Compressed Gases safety sign. See Science Safety File, Appendix 4 Sulphur dioxide cylinders must not be stored beside corrosive substances: a separate area of the chemical store will suffice Protect gas cylinders from external heat sources that may adversely affect their mechanical integrity. Do not store next to radiators or other heat sources Ensure the valve is kept shut on empty cylinders to prevent contaminants entering the cylinder Store gas cylinders securely when they are not in use, they should be properly in the bracket designed for this purpose. This will prevent them from falling over Gas cylinders must be clearly marked to show their contents and the associated hazards Store cylinders where they are not vulnerable to hazards caused by impact e.g. under shelves Handling Cylinders must be transported and securely stored in the bracket provided for this purpose Use gas cylinders in a vertical position, unless specifically designed to be used otherwise Cylinders of capacity greater than 450g must not be used in schools When required wear suitable safety shoes and other personal protective equipment when handling gas cylinders/regulators Do not use valves or regulators for lifting cylinders unless they have been designed and manufactured for this purpose Any cylinders involved in an incident must be withdrawn from service, set aside and clearly marked. The school should then contact TSS for further advice Cylinder Control Valve Cylinder Inlet Connection Control Valve 4

Installation of Only ever install the regulator in an operational fume cupboard Remove the protective cap from the cylinder, clean with a dry, lint free cloth to remove any debris. Do not use if any debris remains and return to supplier Under no circumstances, should sulphur dioxide cylinders be subject to snifting to remove any debris prior to fitting the regulator control valve. (Process of opening cylinder briefly to remove debris). See TGS10a for further information, if required Remove the protective cap from the regulator control valve, clean with a dry, lint free cloth to remove any debris. Retain the protective cap for use when regulator control valve is in storage Check for marks or damage on the thread, this may cause a loose fit and result in gas leakage. Any damaged cylinders must be removed from service and a special waste uplift arranged as soon as practicable Check the regulator control valve is in the closed (no flow) position Using a spanner, attach the regulator control valve to the cylinder, there is no need to over tighten the regulator connection Carry out a leak test and record the results on the inspection record see appendix 1 Producing a flow of gas Only ever use a sulphur dioxide cylinder in an operational fume cupboard Cylinder and regulator control valves should always be opened slowly Hammers, mallets or excessive leverage must never be used on a stiff or frozen valve. Contact TSS for further advice Open the two valves in sequence 1. Turn the cylinder control valve clockwise, this will introduce some gas to the regulator control valve 2. Slowly open the regulator control valve until the required flow rate is achieved, this can be achieved by bubbling the sulphur dioxide through a beaker of water see Fume Cupboard Monitoring Document appendix 2 Turning off Close the two valves in sequence 1. Close the regulator control valve and then close the cylinder control valve 2. Leave the closed sulphur dioxide cylinder in a switched on fume cupboard for a further 10 minutes to ensure remnants of SO2 are no longer present Removal of Make sure both cylinder control valve and regulator control valve are closed and any excess gas has been vented in an operational fume cupboard Use an adjustable spanner to remove the regulator Clean both regulator outlet connection and cylinder inlet connection with a clean dry, lint free cloth to remove any debris and replace protective caps If the cylinder is empty, mark empty and arrange uplift with special waste as soon as practicable Inspection Record The Senior Support Service Technician should maintain a record of inspections, using the record sheet provided. Any faults detected on receipt of the regulator control valve or the gas cylinder should be reported to the supplier immediately and recorded under additional comments on the record sheet. Inspection records should be made available to Health and Safety Officers, TSS Staff and any Officer of the Council if so requested. Records of completed inspections must be retained, in a safe place, for minimum period of five years after the last entry. 5

APPENDIX 1 General Inspections The gas regulator must be checked for leaks by carrying out a simple Leak Test on the occasion of: Each assembly of regulator and cylinder On an annual basis, the results of which should be recorded If there is a suspected leak Leak Test Wear goggles or face visor for this test Leak tests on sulphur dioxide cylinders must be carried out in an operational fume cupboard. With the regulator fitted to the cylinder attach a short length of rubber tubing to the outlet and close the open end with a lab screw clip. See picture below With a paintbrush apply a 1% Teepol solution over the joints and the outside of the regulator. Other generic detergents should never be used due to the hydrocarbon content which may result in contamination Adjust the output pressure to a very low flow rate If any leaks are indicated by the appearance of small bubbles, attempt to tighten all connections then retest If a leak is still evident, remove the regulator control valve and check for damage to the valve threads or cylinder seating. Contact TSS if any damage is apparent. Otherwise, re-seat the regulator control valve and re-test If a leak is still evident, contact TSS for further guidance Once leak test is complete please ensure that you remove any remaining Teepol solution with a damp cloth and dry the regulator Ensure all connections and valves are closed before returning to storage References have been made to: SSERC Bulletin 205 SSERC Bulletin 227 SSERC Hazardous Chemicals Safe Use of Gas Cylinders HSE 2004 Safe Guards in the school laboratory 11 th Edition 6

Glasgow City Council EDUCATION SERVICES Technician Support Service Gas Cylinder Inspection TGS/10b Gas : Inspection Date Visual Inspection Physical damage Yes/No Leak test Date of Purchase: Comments Signed Gas : Inspection Date Visual Inspection Physical damage Yes/No Leak test Date of Purchase: Comments Signed Gas : Inspection Date Visual Inspection Physical damage Yes/No Leak test Date of Purchase: Comments Signed Additional Comments: 7