Effect of 180 bends on gas/liquid flows in vertical upward and downward pipes

Similar documents
Numerical Analysis of Two Phase Flow Patterns in Vertical and Horizontal Pipes

EWGAE 2010 Vienna, 8th to 10th September

A REVIEW OF T-JUNCTION GEOMETRICAL EFFECT ON TWO-PHASE SEPARATION

The Nottingham eprints service makes this work by researchers of the University of Nottingham available open access under the following conditions.

Flow transients in multiphase pipelines

The Study of Bubbly Gas-Water Flow Using

Two-phase Flow Across Small Diameter Split U-type Junctions

EXPERIMENTAL INVESTIGATION OF LIQUID HOLDUP IN HORIZONTAL TWO- PHASE ANNULAR FLOW USING CONSTANT ELECTRIC CURRENT METHOD (CECM)

Experimental investigation of air-water two-phase flow through vertical 90 bend

STUDY OF SLUG CONTROL TECHNIQUES IN PIPELINE SYSTEMS

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

AIR FRACTIONS IMPACT OVER PRESSURE DROP IN AIR- WATER MIXTURE FLOW

PRESSURE DROP AND FLOW BEHAVIOUR OF REFRIGERANT TWO PHASE FLOW IN A SMOOTH HAIRPIN

Numerical simulation of an intermediate sized bubble rising in a vertical pipe

Free Surface Flow Simulation with ACUSIM in the Water Industry

Air entrainment in Dip coating under vacuum

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Akasison Flow phenomena of a siphonic roof outlet

Gas Injection for Hydrodynamic Slug Control

Baker, Glen (2003) Separation and control of gas-liquid flows at horizontal T-junctions. PhD thesis, University of Nottingham.

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Two phase discharge flow prediction in safety valves

ONSET AND SUBSEQUENT TRANSIENT PHENOMENA OF LIQUID LOADING IN GAS WELLS: EXPERIMENTAL INVESTIGATION USING A LARGE SCALE FLOW LOOP

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

ACCUMULATION OF HYDROGEN RELEASED INTO A VENTED ENCLOSURE - EXPERIMENTAL RESULTS

Multiphase Flow Prof. Gargi Das Department of Chemical Engineering Indian Institute of Technology, Kharagpur

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

AIR-WATER FLOW STRUCTURES AT AN ABRUPT DROP WITH SUPERCRITICAL FLOW

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Gas-Liquid Flow Distributions in Multipass Channels with Vertical Upward Branches

Experimental Analysis and CFD Simulation of Pressure Drop of Carbon Dioxide in Horizontal Micro Tube Heat Exchangers

Flow pattern, pressure drop and void fraction of two-phase gas liquid flow in an inclined narrow annular channel

Flow and Mixing in the Liquid between Bubbles

Two Phase Flow Measurement and CFD Analysis in an Air lift loop

DEVELOPMENTS IN PIPELINE FILLING AND EMPTYING EXPERIMENTATION IN A LABORATORY PIPELINE APPARATUS

THE EFFECT OF DRAG REDUCING AGENTS ON PRESSURE GRADIENT IN MULTIPHASE, OILIWATER/GAS VERTICAL FLOW. C. KANG AND W. P. JEPSON

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

Flow assurance in Oil-Gas Pipelines

Measurement and simulation of the flow field around a triangular lattice meteorological mast

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow

Development of High-speed Gas Dissolution Device

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

DETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK

NEW VERSAFLOW CORIOLIS

Application of CFD for Improved Vertical Column Induced Gas Flotation (IGF) System Development

Experimental investigation on air entrainment below impinging jets by means of video observations and image processing

International Journal of Multiphase Flow

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1

Irrigation &Hydraulics Department lb / ft to kg/lit.

Hydraulics analysis of the Heidrun offshore field

The Mechanism Study of Vortex Tools Drainage Gas Recovery of Gas Well

Measurement of both gas and liquid velocity profiles for bubble-induced turbulent flow

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Cover Page for Lab Report Group Portion. Head Losses in Pipes

EFFECT OF CORNER CUTOFFS ON FLOW CHARACTERISTICS AROUND A SQUARE CYLINDER

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Level MEASUREMENT 1/2016

CRYSTALLIZATION FOULING IN PACKED COLUMNS

AN EXPERIMENTAL INVESTIGATION OF SPILLING BREAKERS

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

Section 2 Multiphase Flow, Flowing Well Performance

World Academy of Science, Engineering and Technology International Journal of Chemical and Molecular Engineering Vol:7, No:12, 2013

Flow in a shock tube

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

A Study of Pressure Safety Valve Response Times under Transient Overpressures

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

Results and Discussion for Steady Measurements

Variation in Pressure in Liquid-Filled Plastic Film Bags Subjected to Drop Impact

Gas Lift Workshop Doha Qatar 4-88 February Gas Lift Optimisation of Long Horizontal Wells. by Juan Carlos Mantecon

PRELIMINARY NUMERICAL SIMULATION OF STEADY-STATE GAS-LIQUID FLOW IN HORIZONTAL T-JUNCTION

CIRCUMFERENTIAL NONUNIFORMITY OF WAVES ON LIQUID FILM IN ANNULAR FLOW WITHOUT LIQUID ENTRAINMENT

EFFECTS OF CHEMICAL ADDITIVES ON THE PRESSURE DROP IN THE PIPES

Offshore platforms survivability to underwater explosions: part I

Biography. Abstract. Keywords. Body box, garments, validation, calibration, clean garments, IEST-RP-CC003.3, garment. Introduction and Scope

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

Air-Water Ring in the Vaneless Gap of a Reversible Pump-Turbine Operating in Condenser Mode

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

In this third article of a three-part series, the results of

New power in production logging

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

Laboratory studies of water column separation

Air Eliminators and Combination Air Eliminators Strainers

Instrumentation & Data Acquisition Systems

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Visualization and research of gas-liquid two phase flow structures in cylindrical channel

Gas-liquid Two-phase Flow Measurement Using Coriolis Flowmeters Incorporating Neural Networks

WALL BOILING MODELING EXTENSION TOWARDS CRITICAL HEAT FLUX. ABSTRACT

Truck Unloading Air Eliminators

Two Phase Fluid Flow (ENGINEERING DESIGN GUIDELINE)

Cover Page for Lab Report Group Portion. Pump Performance

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Transcription:

Computational Methods in Multiphase Flow VII 435 Effect of 180 bends on gas/liquid flows in vertical upward and downward pipes A. Almabrok, L. Lao & H. Yeung Department of Offshore, Process and Energy Engineering, Cranfield University, UK Abstract Experimental investigation has been carried out on upward and downward vertical pipes with 180 bends to study gas-liquid two-phase flow behaviours in pipes with serpentine configuration. Wire mesh sensor (WMS) is installed at top and bottom positions of upward and downward sections in order to identify the void fraction distributions. Film thickness probes are employed to obtain circumferential profile of the liquid film thickness at different axial positions along both sections. Further features such as flow patterns are identified by examining the time trace and probability density function (PDF) data. All measurements are conducted for different superficial gas velocities, while superficial liquid velocity is fixed at 1.0 m/s. The study identified that the centrifugal force present in 180 bends caused a flow maldistribution in the adjacent straight sections. It is noted from the time trace and PDF results that the superficial gas velocity has obvious effects on the flow development along different positions of the pipes, where the flow regime varied over whole velocity ranges tested. These results are confirmed by the cross-sectional view and sliced stack images (longitudinal view) of the void fraction distributions. The results also showed that the flow behaviour in upward and downward pipes is affected by bends, although to varying degrees. Keywords: upward, downward, 180 bends, film thickness probes, WMS. 1 Introduction Gas-liquid two-phase flows in serpentine vertical pipes connected together by 180 bends are of great importance in a wide range of engineering practices. The development of many new technologies such as the design of offshore gas and doi:10.2495/mpf130361

436 Computational Methods in Multiphase Flow VII oil pipelines and the prediction of heat transfer characteristics for condensation/evaporation processes have been related to gas-liquid issues. Furthermore, in many industrial units such as a large cracking furnace in a refinery, the tubes are arranged in a serpentine manner and are relatively short. Thus, it is not clear how much effect the bends exert on the flow in the straight part of the tube. As flow negotiates round the 180 bend at the ends the generated centrifugal force could cause flow maldistribution creating local dry spots, where no steady liquid film formed on the pipe walls. As a result, events including coking, cracking and overheating of heat transfer surfaces, may occur and lead to frequent shutdown of the facilities. This could increase the operating costs and reduce production revenue. However, a large amount of investigations such as that of Alves [1], Oshinowo and Charles [2], Usui et al. [3], Azzi et al. [4], Azzi and Friedel [5], Spedding and Benard [6] and Shannak et al. [7] are available in a literature. These investigations are limited to upward flow with small diameter pipe ranging from 5 to 50 mm. Reported literature on two-phase flow in 180 bends in large diameter pipes is scarce. Abdulkadir et al. [8] carried out an experimental study into the churn-annular flow behaviour to measure mean film fraction of air-water mixture through a vertical 180 return bend using electrical conductance tomography sensor. The study is distinctive in that it is probably the first major study in open literature on 180 bends utilising a large internal diameter (i.d. =127 mm) pipe. They measured film fraction using conductance ring probes positioned before the bend, within the bend (at 45, 90, 135 angles) and after the bend. They noted that the average film fraction is higher in the straight pipes than in the bends and that at low liquid/higher gas flow rates, film break up occurs at the 45 bend due to gravity drainage. They also reported that the flow behaviour round the bend is affected due to existence of centrifugal and gravitational forces. The objective of the current work is to expand the understanding of flow behaviour in large diameter pipes connected together by 180 bends. The experimental investigation focused on the gas-liquid two-phase flow development in both upward and downward straight sections of pipes after a 180 bend. 2 Description of test facility and instrumentation The serpent test facility (Figure 1) is specially designed and built in the Flow Laboratory at Cranfield University. The test facility is divided into three sections: the fluid supply and metering section, the test section and the separation section. This facility is controlled by data acquisition system which includes Delta-V and Labview systems. Water and air at measured rates are mixed through a T-junction then fed through the test section and finally exit into the ventilation tank where the water and air are separated. After separation the water flows back to its storage tank while the air is vented into the atmosphere. The test section consists of a flow loop of about 20 m long in total and 101.6 mm bore size pipeline which includes four vertical upward and

Computational Methods in Multiphase Flow VII 437 V-33 V-34 3rd F Compressor Union F11 P6 P5 P2 F22 P1 2nd F GA55 GA75 To Relief Outlet V-26 OUTLET D250 Vent Tank V-24 BD1 V-37 T2 VF2 VF1 VC1 V-27 MIXER V-28 V-25 V-23 I-14 V-36 V-31 I-16 V-29 1st F Air Receiver V-39 F12 P4 P3 T1 F21 V-32 V-35 P-77 Water Tank V-30 V-38 PUMP I-18 GND Figure 1: Schematic of test facility. The liquid film probes are shown in green colour and the wire mesh sensor is shown in red colour. downward sections connected by three identical transparent 180 bends. The bend s centre line radius (CLR) is 203 mm. The locations of the liquid film probes are 4.91, 30.41 and 46.16 pipe diameters downstream and upstream of the top and bottom bends The film probes consist of four conductive sensors distributed circumferentially around the pipe, as shown in Figure 2. The sensing part of the conductivity film thickness probes compose of two stainless steel conductors arranged with the insulator between them. The end of the sensor is mounted flush with the inner surface of the pipe. Each conductor is electrically in contact with the liquid film when the liquid film flows over them so a conductive bridge is formed between them. The 32 32 capacitance WMS is installed at the top and bottom positions of downward and upward sections with axial distances 4.41 and 45.66 pipe diameters downstream and upstream of the top and bottom bends A more detailed description of this technique is presented by Da Silva et al. [9].

438 Computational Methods in Multiphase Flow VII (a) (b) Figure 2: Circumferential positions of the sensors in film thickness probes at downward section (a) and upward section (b). 3 Procedure of the tests The test section is first emptied and blown dry. The air flow is stopped to record the zero points of the instrumentation. The rig is then filled with water to record full scale output of liquid film probes. The water flow rate is adjusted to a predetermined value before air is introduced to the test section, and then the water flow rate is monitored and adjusted to keep it at the predetermined value while the air flow is slowly increased to the desired value. Finally, the test section is again emptied and blown dry to record the zero point of the instrumentation. 4 Results and discussion The results from air-water two-phase flow tests are for the void fraction distributions and liquid film thickness in upward and downward flows. These results are expected to provide more knowledge about the gas void fraction distributions and liquid film profiles along different parts of the vertical pipes. 4.1 Flow regime and its development In this study, the time trace, PDF and cross-sectional distributions of the void fraction are used to explore the effects of 180 bend on the flow regime and its development at various locations along the pipe. All results presented here are obtained at superficial gas velocities of 0.52 and 9.79 m/s, whilst the superficial liquid velocity is fixed at 1.0 m/s. 4.1.1 Downward flow The time trace data illustrated in Figure 3(a) shows that the characteristic of waves at the top position is not similar to the bottom position. This is because the significant effects of the top bend on the void fraction characterises the top position. A large fluctuation of the flow is identified at the top position, due to the action of centrifugal force that is present in the bend, while the flow regime at the bottom position is confirmed to be a slug flow accompanied by huge waves as shown in Figure 4(a). The PDF shape represented in Figure 3(b) shows that unstable flow with a broad base is formed at the top position, for superficial

Computational Methods in Multiphase Flow VII 439 Figure 3: stack image of the void fraction at the top position of downward, for superficial gas and liquid velocities of 0.52 and 1 m/s, Figure 4: stack image of the void fraction at the bottom position of downward, for superficial gas and liquid velocities of 0.52 and 1 m/s, gas velocity of 0.52 m/s and superficial liquid velocity of 1.0 m/s. Slug flow is observed at the bottom position for the same conditions, as illustrated in Figure 4(b). The difference between the flow regimes at the top and lower positions is due to the effect of the top bend on the void fraction distributions at the top position. This effect diminishes as the flow reaches the bottom position. Figure 3(c) and (d) represents the cross-sectional view and sliced stack images of the void fraction distributions respectively, that are identified at the top position. In all images, the liquid phase is shown in blue colour while the gas phase is shown in red colour. The present study used these images as another approach to

440 Computational Methods in Multiphase Flow VII interpret the flow regimes and its development along the pipe. It is important to mention that these images are applied to validate the time trace and PDF results. Figure 3(c) and (d) shows that an asymmetrical flow is identified at the top position, which is accompanied by a large number of liquid droplets entrained into the pipe centre (classified as wisps). This is due to the action of centrifugal force that acts to push the liquid phase into the outer curvature of the bend. On reaching the bottom position, the wisps become less and the flow is observed to be more symmetrical, as shown in Figure 4(c) and (d). By increasing the superficial gas velocity further to 9.79 m/s, the time trace data at the top position shows that the height of waves is very large compared with those identified at the bottom position, as illustrated in Figures 5(a) and 6(a) This is because at the top position more bubbles are trapped in the pipe centre due to the action of the top bend. The PDF characteristic for the top and bottom positions shows annular flow formation, as illustrated in Figures 5(b) and 6(b) These results are confirmed by analysis of the crosssectional view and sliced stack image of the void fraction distributions at both positions. Figure 5(c) and (d), confirmed that at the top position the annular flow is created with a large number of liquid droplets entrained into the pipe centre in the form of wisps. This is based on the fact that the centrifugal force present in the bend could cause a flow maldistribution in the adjacent straight sections, which is acting to push the liquid into the outer curvature of the bend. On the other hand, the flow becomes more uniformly distributed with less liquid entrainment when it has reached the bottom position, however it is still annular, as presented in Figure 6 (c) and (d). These observations are validated by the film thickness data obtained at the same position and for the same velocities, as shown in Figure 11(b). Figure 5: stack image of the void fraction at the top position of downward, for superficial gas and liquid velocities of 9.79 and 1 m/s,

Computational Methods in Multiphase Flow VII 441 Figure 6: stack image of the void fraction at the bottom position of downward, for superficial gas and liquid velocities of 9.79 and 1 m/s, 4.1.2 Upward flow Figures 7 and 8 present a comparison between the bottom and top positions respectively, for stack image of the void fraction. The comparison is made for superficial gas velocity of 0.52 m/s, whilst superficial liquid velocity is fixed at 1 m/s. Figures 7(a) and 8(a) show different signals between the time trace data obtained Figure 7: stack image of the void fraction at the bottom position of upward, for superficial gas and liquid velocities of 0.52 and 1 m/s,

442 Computational Methods in Multiphase Flow VII at the bottom and top positions The shape of PDF presented in Figure 7(b) confirms that the flow regime observed at the bottom position is bubbly to slug flow transition. The existence of large bubbles in a liquid phase contributed to the broad base. While, the shape of the PDF at top position is significantly different, which indicates a slug flow formation as presented in Figure 8(b). It can be noted from the cross-sectional view of the void fraction distribution and its sliced stack image shown in Figure 7(c) and (d) respectively, that the transition from bubbly to slug flow is confirmed at the bottom position. In contrast, Figure 8(c) and (d) shows that a slug flow accompanied by large bubbles (classified as Taylor bubbles) is formed at the top position. Figure 8: stack image of the void fraction at the top position of upward, for superficial gas and liquid velocities of 0.52 and 1 m/s, An examination of the time trace data at the bottom and top positions shows a similar tendency of the time trace signal when the superficial gas velocity is increased to 9.79 m/s, as illustrated in Figures 9(a) and 10(a) However, the time trace signal at the bottom position shows higher variations than that at the top position. The plots in Figures 9 (b) and 10(b) represent the PDF results obtained at the bottom and top positions It is clear from the plots that the PDF shapes did not show any discrepancies. Churn flow is observed for both positions with a broad base of void fraction values. These results are consistent with those obtained from the cross-sectional view and sliced stack image of the void fraction distribution. The flow profile at the bottom position is observed to be more evenly distributed than that at the top position. These results are in good agreement when compared with the circumferential distribution of liquid film, as shown in Figure 12(b).The film thickness at the bottom position is affected by the action of centrifugal force that exists in the bottom bend. On the contrary, the effect of this force is reduced when the flow reached the top position. This in turn led to create uniform liquid film profile around the cross section of the pipe.

Computational Methods in Multiphase Flow VII 443 Figure 9: stack image of the void fraction at the bottom position of upward, for superficial gas and liquid velocities of 9.79 and 1 m/s, Figure 10: stack image of the void fraction at the top position of upward, for superficial gas and liquid velocities of 9.79 and 1 m/s, 4.2 Circumferential distribution of the liquid film In this study, circumferential distribution of liquid film is investigated along different positions of the pipe. Figures 11 and 12 below show the plots of the liquid film distribution at the top, middle and bottom positions of downward and upward sections respectively, for superficial gas velocities of 1.32 and 9.79 m/s respectively, while a superficial liquid velocity is fixed at 1.0 m/s.

444 Computational Methods in Multiphase Flow VII 4.2.1 Downward flow It can be noted from the plots presented in Figure 11(a) and (b) that the liquid film thickness at 90 of the top position (corresponds to the sensor CT2 located in the outer curvature of the top bend) is thicker than other locations (0, 180 and 270 ) for the whole ranges of superficial velocities tested. This is due to the effect of the centrifugal force that observed to push the liquid into the outer curvature of the bend. The force effect diminishes when the flow reached the lower measuring positions. As a result, the liquid film profile at the middle and bottom positions are almost identical. It is worth mentioning that the top bend has no obvious effect on the middle and bottom positions even at higher superficial gas velocity, as shown in Figure 11(b). 180 o 5.00 4.00 3.00 2.00 1.00 Top Middle Bottom 180 o 4.00 3.00 2.00 1.00 Top Middle Bottom 90 o 0.00 270 o 90 o 0.00 270 o Figure 11: 0 o (a) Circumferential profile of the liquid film in downward at superficial gas velocities of 1.32 m/s (a) and 9.79 m/s (b), and superficial liquid velocity of 1 m/s. (Axes unit in all plots is mm). 0 o (b) 4.2.2 Upward flow Figure 12(a) shows that the film thickness distribution at the top, middle and bottom positions is systematically circumferentially uniform. However, the film thickness at the bottom position is notably thicker than those at the top and 90 o 180 o 6.00 5.00 4.00 3.00 2.00 1.00 0.00 270 o Top Middle Bottom 90 o 180 o 3.00 2.50 2.00 1.50 1.00 0.50 0.00 270 o Top Middle Bottom 0 o (a) (b) 0 o Figure 12: Circumferential profile of the liquid film in upward at superficial gas velocities of 1.32 m/s (a) and 9.79 m/s (b), and superficial liquid velocity of 1 m/s. (Axes unit in all plots is mm).

Computational Methods in Multiphase Flow VII 445 middle positions. This evidence suggested that, at these conditions the centrifugal force action on the liquid film distributions is insignificant for all positions. With increasing the superficial gas velocity to 9.79 m/s, the film profile for the bottom position is considerably affected by the centrifugal force that is present in the bottom bend, as illustrated in Figure 12(b). 5 Conclusions In this study, film thickness probes and WMS are applied to investigate the effects of 180 bends on behaviours of gas-liquid flows. The study found that the top and bottom bends have considerable impacts on the liquid film and void fraction profiles, to varying degrees. The action of these bends is highly dependent on the superficial gas velocity. The study also identified that the centrifugal force present in bends causes a flow maldistribution in the adjacent straight sections. From the time trace, PDF, cross-sectional view and sliced stack images of the void fraction distributions, it can be concluded that the superficial gas velocity has an obvious effect on the flow development along both orientations, where the flow regime varied over whole velocity ranges tested. References [1] Alves, G.E., Co-current liquid-gas flow in a pipeline contactor. Chemical Engineering Progress, 50, pp. 449 456, 1954. [2] Oshinowo, T. and Charles, M.E., Vertical two-phase flow Part 1: Flow pattern correlations. The Canadian Journal of Chemical Engineering, 52, pp. 25 35, 1974. [3] Usui, K., Aoki, S., and Inoue, A., Flow behaviour and phase distributions in two-phase flow around inverted U-bend. Journal of Nuclear Science and Technology, 20, pp. 915 928, 1983. [4] Azzi, A., Friedel, L., Kibboua, R. and Shannak, B., Reproductive accuracy of two-phase flow pressure loss correlations for vertical 90 degree bends. Forschung im Ingenieurwesen, 67, pp. 109 116, 2002. [5] Azzi, A. and Friedel, L., Two-phase upward flow 90 degree bend pressure loss model. Forschung im Ingenieurwesen, 69, pp. 120 130, 2005. [6] Spedding, P.L., and Benard, E., Gas-liquid two-phase flow through a vertical 90 degree elbow bend. Experimental Thermal and Fluid Science, 31, pp. 761 769, 2006. [7] Shannak, B., Al-Shannag, M., and Al-Anber, Z. A., Gas-liquid pressure drop in vertically wavy 90 bend. Experimental Thermal and Fluid Science, 33, pp. 340 347, 2009. [8] Abdulkadir, M., D. Zhao, Azzi, A., Lowndes, I. S. and Azzopardi, B. J., Two phase air-water flow through a large diameter vertical 180 return bend. Chemical Engineering Science,79, pp. 138 152, 2012. [9] Da Silva, M.J., Thiele, S., Abdulkareem, L., Azzopardi, B.J., and Hampel, U., High resolution gas-oil two-phase flow visualization with a capacitance wire mesh sensor. Flow Measurement and Instrumentation, 21, pp. 191 197, 2010.