PRODUCT DATA SHEET. Description

Similar documents
TECHNICAL DATA Q= C. Table 1 - Specifications

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

T208VR Series Tank Blanketing Vacuum Regulator

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

VBS-9263 Series. Application. Features. Applicable Literature

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Laboratory Flowmeters

GILMONT ACCUCAL FLOWMETERS

CSA Sample Draw Aspirator Adapter Operator s Manual

Air Eliminators and Combination Air Eliminators Strainers

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Table 1 - Specifications

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

VB-7263 Series. Application. Features. Applicable Literature

Constant Pressure Crude Oil Container Model CPCCP

shutoff valves 900 Series psig Manual Shutoff Valves

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

RCD - Ultra-Rugged Differential Pressure Flowmeter

RK-IR Sample Draw Aspirator Adapter Operator s Manual

MECHANICAL BULKMETERS BM Series

PX800 M E T A L PX800 PERFORMANCE WIL T-08

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

PX1 PX1 PERFORMANCE M E T A L WIL T-12

VB-7273 Series. Application. Features. Applicable Literature

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA CAUTION

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Avenger Model 33M Installation & Operation Instructions

Air Operated Hydraulic Pumping Systems to 50,000 psi

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

Types ACE95 and ACE95Sr Tank Blanketing Valves

Precision pressure sensor Basic version Model CPT6020

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Types ACE95 and ACE95Sr Tank Blanketing Valves

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

OPERATOR S MANUAL

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

V43 Pressure Actuated Water Regulating Valve

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Types ACE95 and ACE95Sr Tank Blanketing Valves

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

INSTALLATION & MAINTENANCE INSTRUCTIONS

DPC-30 DPC-100. Reference Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA CAUTION

Y692VB Series Vacuum Breaker

Multi-Probe Sampling System User Guide & Manual

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

TECHNICAL DATA. Q = C v P S

Full Range Pressure Compensating Variable Flow Control

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Mechanical Pressure Measurement

FloWash. Industrial Filter Cart

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

FOAM TANK (1/2) DATA SHEET

Liquid ring compressors

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

P.C. Flow Regulator Valve Series FR101. General Description

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Pneumatic Powered - Plunger Pumps

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

Series IRV1000/2000/3000

Installation Operation Maintenance

FILTER BYPASS CONTROL

2 I All-Flo Pump Co.

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

V248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure

ADAPTABILITY & PRECISION

RK LEL Sample Draw Aspirator Adapter Operator s Manual

1020 Industrial Drive, Orlinda, TN fax

CASH VALVE TYPE KP BACK PRESSURE VALVES

2 I All-Flo Pump Co.

TROUBLESHOOTING GUIDELINES

GEMS SENSORS & CONTROLS

TECHNICAL DATA. Q= Cv S

QBS Electronic Pressure Regulator

Digital Hydraulic Multimeters

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

PRO SINK -R 1 and 2. Dilution system CONTENTS

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

553 Series.

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Model Series 62 Constant Differential Relay

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Transcription:

PRODUCT DATA SHEET Series 820 Digital Flow Meter Description of Included Models Model Number 825 Description All the great standard features of the Sotera digital meters can be found on the model 825, which is equipped with 180 inlet and outlet ports - 1"NPT. Shipping Weight 3 lbs. 1.4 kgs. Available Options SAE threaded inlet/outlet ports available for both models. Accessories No accessories available for this meter at this time. Performance Recommended Flow Range Maximum Pressure Temperature Accuracy Units of Measure Range 2 to 20 GPM (7.6 to 75.7 LPM) 120 PSIG (8.2 Bars) at 70 F (21 C) 50 PSIG (3.4 Bars) at 130 F (54 C) Minimum Operating - 0 F (-17.8 C) Maximum Operating - 130 F (54.4 C) ±0.5% Using Calibration Factor ±0.2% Using Liquid Calibration Ounces, Pints, Quarts, Liters and Gallons. (Special options also available.) 9999 Current Total 10,000,000 Accumulated Total

Calibration Curve Note that the indicated factors are accurate with the original factory or a water. See the Parts and Service Guide that came packed with your meter, or available in the Reference Documents section of this page for a more extended discussion of and factors for common fluids.

Fluid Compatibility The 825 Digital Meter will handle most pesticides, automotive fluids (except gasoline) and mild acids. The 825 Digital Meters are NOT compatible with very strong acids. If in doubt about the compatibility of a specific fluid, contact the supplier of the fluid to check for any adverse reactions to the following wetted materials. Polypropylene Body Stainless Steel Screws/Shaft Fluorocarbon Seals Ryton Chamber Dimensions Repair To insure the ultimate performance, pumps must be set up according to the "INSTALLATION" section of the Owner's Manual packed with the pump and available below in the Reference Literature section. Warranty repairs on your meter should only be carried out according to the procedures specified in the Warranty Procedure outlined in the Reference Literature section.

Maintenance Meters are designed to operate maintenance free. Certain liquids can dry out while in the meter housing, preventing the meter from operating properly when next used. If this happens, the meter should be thoroughly cleaned by running a flushing fluid through the meter in the normal direction of fluid flow, without disassembly. If fluid cannot be "forced" through the meter with 50 PSIG fluid pressure and thus freed, the meter must be disassembled and thoroughly cleaned. Refer to the instructions in the ASSEMBLY/DISASSEMBLY section of the Parts and Technical Service Guide that was packed with your meter or is available below in the Reference Literature section for the procedure. Frequently Asked Questions 1. When I went to use my meter for the first time this year it was stuck. What can I do? Although your meter is designed to require little or no maintenance, the residual material left when a fluid dries in the meter can jam the close tolerance disc within the chamber. See the procedure recommended for cleaning the meter above and in the Guide referenced below and packed with the meter. Generally a thorough cleaning will restore the meter to full operation. 2. Is this meter approved for commercial use? This meter mechanism is capable of high accuracy, typically 0.5%, if operated under steady flow rate and calibrated at that rate. This capability however does not meet the requirements of the Weights and Measures Departments in most states and they therefore will not approve this meter for use for the resale of liquids. 3. What do you mean by a "positive displacement meter? A positive displacement meter allows a VERY specific volume of fluid to move through the meter with every rotation of the mechanism. Conversely if the mechanism of a positive displacement meter is held, there should be no flow through the meter. That VERY specific volume is determined by the designed size of the meter chamber and allows the rotating meter shaft to be tied to a counter which indicates the count of rotations as the volume of fluid passing through the meter. By varying the gear ratio tying the chamber to the counter, the same chamber can be used for two different units of measure, like gallons and liters.

4. How can I be sure my meter is operating properly? After zeroing the meter, fill a container of known volume and compare the indicated volume to the measured volume. As simple as this method seems it is used universally as the absolute means by all requiring accurate meter indication. A container used for this type is described as a "proving can" and the use of a proving can 5X the major unit of is recommended. In the case of the 800 meter, where gallon is the most common unit of measure, a five-gallon proving can is recommended and generally can be obtained from the dealer where your meter was purchased. 5. What limits the flow capacity of this meter? The forced flow of fluid through the meter results in a pressure differential measured across the meter, and the higher the flow through the meter, the higher that pressure drop across the meter. While the increase in pressure drop is close to linear with the increase of flow over a considerable range, that linearity is lost at the upper flow levels because of the physical size of the chamber and the ports into and out of the chamber. The upper limit where that linearity is lost is normally taken as the upper flow limit of allowed operation. In the case of the 800C that flow level is 20 GPM. 8825 Aviation Drive Fort Wayne, Indiana USA 46809 Tel 260/747-9060 Fax 260/747-3934