ECD Low Pressure Micro Bubble Ceramic Diffuser - User Instruction Manual

Similar documents
ECD High Pressure Ceramic Micro Bubble Diffuser - User Instruction Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

OWNER S MANUAL. Table of Contents

Installation & Instruction Manual For Portable Series R.O. units:

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Installation, Operation and Maintenance Manual

453 Series Steam Heated Vaporizing Regulator

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

4-in-1 Professional Inflator Kit

Nitrogen Supply System

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

D Series Air and Water Kit Part# 02550

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

J Air and Water Kit Instructions Part# 02584

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Accu-Tab PowerBase 3012AT by Axiall Corporation

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

92831 TEL: (714) FAX:

Yoke Block Instruction Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Model Series 62 Constant Differential Relay

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Installation Instructions JATCO Environmental Protection Tank Model J-7000

OPERATION MANUAL NTF-15

Accu-Tab PowerBase 3070AT by Axiall Corporation

MODEL CALIBRATION GAS DELIVERY SYSTEM

OPERATION MANUAL NTF-60 Plus

ENERGY BLADE 3K4. Energy Blade Installation Instructions

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

92831 TEL: (714) FAX:

OWNER S MANUAL FOR THE FOAM MARKER FM24. In-Ex PO Box Harts Road, Tiritea Palmerston North Ph: Fax:

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

CSA Sample Draw Aspirator Adapter Operator s Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

ROPV R40 E Series User Manual

Installation, Operation, and Maintenance Manual

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

CLEANING AUTO CELL OWNERS HANDBOOK

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Diffused Aeration Systems Installation Operating Maintenance Guidelines

Yoke Block Instruction Manual

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Cocoa Patio Pond with Lit Spillway

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTALLATION & MAINTENANCE INSTRUCTIONS

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Geotech 1.66 Auto-Reclaimer Installation and Operation

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

RG3100 and RG3100Ice Regulator System

1020 Industrial Drive, Orlinda, TN fax

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Diffused Aeration Systems. Installation Operating Maintenance Guidelines

RAM 4021 Operation Manual

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

KJ1000 Operating Instructions & Parts Manual NSN

GILMONT ACCUCAL FLOWMETERS

V-24 OXYGEN LANCE VALVE

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

aeration and mixing systems

ACCU-MIX 1200 / / 26270

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

User Operation Manual and Safety Instructions

Swimming Pool IAQUALINK WEB CONNECT

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Installation and Operating Instructions

PM105 PRESSURE METER USER S MANUAL

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Instructions for use Compressed air injector with water trap

Installation and commissioning instructions 255 series and 256 series

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

G7S Hand Pump Owner s Manual

Alkylphosphines. Storage and Handling Recommendations

Model Portable Eyewash

SINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS. Certified ISO 9001

Pressure Relief Valve Instruction Manual

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Liquid Thin Film Technology

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

MANIFLEX System. 52B Series 52C Series 52S Series INSTALLATION AND OPERATION INSTRUCTIONS

IMPROVING PLANT AERATION USING GAS INFUSION TECHNOLOGY

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Operation and Maintenance Manual

Transcription:

Enviro Ceramic Ltd Carrigbawn House, Drinagh, co.cork, P47 C678 Ireland Tel: (+353) 874533821 info@enviroceramic.com www.enviroceramic.com ECD Low Pressure Micro Bubble Ceramic Diffuser - User Instruction Manual IMPORTANT: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your diffuser. Please keep it in a safe place so that it is easily available for future reference, for you or any other person not familiar with the operation of this diffuser. Description: The Enviro Ceramic Diffuser (ECD) consists of a high-tech gas diffusion ceramic membrane for efficient micro bubble transmission into water or other suitable liquids. The engineered ceramic membrane is made from ultra-fine nano porous aluminium oxide, sintered at high temperature before being encapsulated in tough PU filled resin with marine grade stainless steel fittings. Ultra-fine mist of micro bubbles appear quickly at low pressures of only 20-40 kpa (3-6 psi) and the unique patented design allows an airlift principle to move anaerobic water from the tank floor through the centre, thereby increasing efficient gas transfer. The novel antimicrobial ceramic also aids in preventing biofouling of the diffuser. Page 1 of 6

Application: Koi Ponds: The mist of air bubbles created optimises Koi Pond aeration and the brown ceramic and resin camouflages the diffuser visibly from disruptions of seeing your beautiful fish. Water circulation pump failure or high summer temperatures can lead to decreased oxygen levels that can cause fish dying, diffusers aid in avoiding this. It is also recommended to supplement oxygen levels during the night. The diffuser is also used effectively for the safe transportation of fish. Hydroponics/Aquaponics: In a Deep Water Culture (DWC) hydroponic system it is vital to have sufficient oxygen levels because the roots are submerged. For optimal growth it is recommended to diffuse 1.5 L/min of air into 50 litres (130 gallons) of cooled nutrient solution to maintain Dissolved Oxygen (DO) levels of 8-9 ppm. Be aware to adjust ph levels over time and keep the water temperature around an optimum of 22 C (72 F). Other systems require less oxygen, only to maintain aerobic conditions from the perpetual motion the diffuser creates with its tiny bubbles and airlift principles. Marine Tanks: These diffusers are most suitable for supplementing oxygen in sea water with increased fish stock densities and as an emergency back-up device. Waste Water Treatment: The supply of oxygen for aeration is the single largest energy consumer at an activated sludge wastewater treatment plant. Due to the higher efficiency of ECD diffusers, compared to membrane diffusers or bubbly hoses, the ECD s are effectively used for reducing biochemical oxygen demand (BOD) and chemical oxygen demand (COD) in ponds, channels and larger pipes as well as aiding aerobic bacteria for digesters. Gasses to be used: The ECD ceramic diffuser is made for use with gasses such as oxygen, carbon dioxide, nitrogen and air. Please contact us about ozone or any other gas applications. It is important that the gas and especially compressed air supply is completely oil and dust free by using suitable recommended filters (minimum 5 micron). This will aid in preventing internal blockages of the ceramic pores. When using compressed air in an aquatic system, please be aware of the possibility of causing gas bubble disease from dissolved nitrogen gas. Page 2 of 6

Specification: Classification: Model Number: Low Pressure Ceramic Diffuser ECD 200 Black Diffusing Area: 200 cm 2 / 31 in 2 Recommended Operating Range: Nett Weight: Size/Dimensions: Packaging of 10 units: Maximum Operating Pressure: Bubble Size: 1.5-3 L/min@20-40 kpa 3.2-6.4 ft 3 /hr@ 3-6 psi 1.2 kg 2.65 lbs Ø225 x 40 mm high 13 kg, 26x26x70 cm, 47 L Do not exceed 100 kpa (14.5 psi) Measured with a high speed camera at 400 mm height, they average 100 to 300 µm at 20-40 kpa in fresh water. Efficiency: Depends totally on conditions. Approximately 20-70 % is achievable. Gas inlet connection Fittings: Materials of manufacture: Due to different installations, we do not supply hose connections. Use a 1/8 NPT thread male fitting for your gas hose connector. Inert nano porous ceramic and PU filled resin with 316L grade stainless steel fittings. Installation & Operation: When using an Air Pump please ensure it can supply sufficient pressure and flow rate for the required application. We recommend using a small Compressor pump. When using higher pressure rated Bottled Gas or Compressors use a suitable quality Pressure Regulator. This should be set at a maximum of 100 kpa (14.5 psi). A gas filter must be fitted to remove any dust particles or oil (<5 micron) that may come from the supply line to the diffusers, especially when using a compressor. This dust or oil may block the fine pores inside the ceramic on the long term and cannot be removed. Fit a pressure relief valve set at 1 bar on the gas supply line, this protects the diffusers and rotameters from damage if over pressurized. Fit a needle valve and rotameter (flow meter) after the air pump or regulator/filter. It is recommended to use one for each diffuser mounted on a manifold, this ensures control of optimum gas flow rates. Connect your choice of 1/8 NPT male fittings for your gas supply hose connection (usually Ø 6-8 mm hose) to the diffuser. Do not over tighten connections but ensure there are no leaks. Use PTFE tape or a suitable sealant on the threads if required. BSP 1/8 threads may also be used if NPT is not available. Page 3 of 6

Any number of diffusers can be connected to a common supply line as long as they each have a needle valve rotameter connected, otherwise the last diffusers in line could get no gas. Avoid using other manufacturer s diffusers on the same common supply line, unless a needle valve rotameter is used, as they function at different flow rates and pressures. There are 6 mounting holes (Ø8mm) on the diffuser resin base to secure it to a frame or tank floor as required. The deeper the diffuser is underwater, the better the efficiency will be, as the bubbles take longer to rise. A minimum depth of 50 cm is recommended. A sideway current over the diffuser will increase the efficiency as bubbles drift sideways and take longer to rise. Always seat the diffuser horizontally, without obstructions, to avoid rising bubble coalescence. The higher the flow rate deviates from the recommended range, the larger the bubbles will become and the gas transfer efficiency will decrease accordingly. Due to the unique design of the ECD, the diffuser should always be lifted at least 10 mm off the tank floor in order to create the motion needed to move water through the diffuser centre (airlift principle) that increases gas transfer efficiency. Start Up: Ensure the supply pressure will not exceed 1 bar (14.5 psi) on the regulator and open it to the set pressure. Open the needle valve on the flow meter slowly to the fully open position. If the diffuser was submerged for a while, there will be a small delay before start up. It can take up to 2 minutes for the flow rate to stabilise and push out all the water from the diffusers air plenum. Now reduce the flow rate with the needle valve to its recommended operating flow rate, this will supply you with its ideal gas absorption performance. Where necessary, monitor the oxygen levels with an optical DO Meter (we recommend the optical DO sensor from www.gryf.eu/en ) and adjust the diffuser flow rates to the optimum requirements accordingly. A diffuser produces the best bubbles when wetted. A dry diffuser will show bigger and irregular bubbles. Soak diffusers for 1 hour before testing for best results. Page 4 of 6

Do not contaminate the ceramic surface with any hydrophobic materials (i.e. oils, fats or greases) as these repel water and cause large bubble formation. High lipid content water will also reduce performance due to bubble coalescence. Avoid physical shock as this may cause defects or breakages, always handle with care. Do not subject the diffuser to freezing temperatures, the water inside the plenum may freeze and expand and this can cause the ceramic or resin to crack. Do not expose the diffusers to temperatures above 60 C as it will weaken the resin. Health & Safety: Gasses under pressure can be dangerous. All diffusers are tested to 2 bar for safety. Avoid over pressurizing and exposure to oxidizing agents and always operate diffusers only submerged under water. All health and safety issues relating to gasses, cleaning chemicals and other equipment should be strictly adhered to according to the supplier s recommendations. Cleaning & Maintenance: The ECD s are developed with an inert anti-microbial ceramic that prevents algae growth and biofouling on the ceramic surface and inside the pores. However, with time and adverse waters, the gas flow rate may decrease (i.e. higher pressure is needed to achieve the same gas flow rate) and periodic checks are required to ensure the surface is still performing effectively. Frequency: A routine monthly check and quick wipe clean with a soft sponge and fresh water is recommended. Cleaning will be more frequent with high turbidity or foul water. To remove algae build up, soak the semi dry diffuser in a 6% solution of hydrogen peroxide or diluted bleach (5 % solution). Soak for five minutes or longer as required. Rinse thoroughly with fresh water to remove all traces of the cleaning solution. Repeat the cleaning process if required. The hydrogen peroxide / bleach also sterilises and disinfects the diffuser. To remove metallic salts (ferric and carbonate salts), wipe surface with diluted citric or acetic acid. Rinse thoroughly with fresh water to remove all traces of the acid. Only use diluted acid as the metal fittings may corrode if used incorrectly. Do not use soap or detergents as they may block the ultrafine pores. Diffusers taken out of service must be cleaned, sterilised and dried before storing in a dust free dry environment at room temperature. Warranty & Limits of Liability: EnviroCeramic warrants its diffusers under normal use as set out in the documentation against defects from the date of purchase/invoice/conformance certificate for a period of one year. Any failure resulting from defective parts or faulty workmanship, as determined during evaluation by EnviroCeramic, will be repaired or replaced under warranty. EnviroCeramic s obligation under the warranty is conditional upon: 1 Such diffuser is being installed, consistently used and maintained in accordance with EnviroCeramic s written instructions, specifications and safeguards as outlined in this latest revised document or otherwise specified in writing by EnviroCeramic. 2 The defect (s) not being the result of misuse, neglect, accident Page 5 of 6

or improper application nor of any user attempts at modification or repair. 3 The purchaser reporting to EnviroCeramic any defect within five days of its occurrence. 4 EnviroCeramic may request that the diffuser in question be returned to EnviroCeramic s premises in its original or suitable packaging. EnviroCeramic may also require a written report and photos by the purchaser of the circumstances in which the defect occurred. 5 For goods returned outside the EU there will be a returned goods delivery charge at cost price. 6 The purchaser certifies acceptance of the warranty as set out. EnviroCeramic s obligations specifically exclude any liability whatsoever for claims by the purchaser or user or any other persons or parties: 7 In respect of merchantability or fitness for a particular purpose. 8 For any special, indirect, incidental or consequential damages resulting from the use, or as a result of a malfunction of the diffuser. 9 For personal injury or any medical or disability claims or for compensation arising therefrom. 10 This warranty and the conditions, limitations and exclusions are accepted by the purchaser as the only authorised and applicable warranty and that there are no other warranties or conditions, oral or written, expressed or implied. 11 EnviroCeramic is continuously improving its products and services and therefore reserves the right to change specifications and designs as and when needed without prior notice. We manufacture according to strict quality systems and management principles and each hand crafted diffuser has a unique traceable batch number displayed. Each diffuser is also tested for pressure compliance and flow rate conformance. We aim to continually improve our diffusers by research and development in conjunction with customer needs and recommendations. We deliver worldwide and have strategic partners/agents on all continents for further support. PLEASE CONTACT US FOR SALES AND SERVICE AT: info@enviroceramic.com Page 6 of 6