D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Similar documents
Pressure Dump Valve Service Kit for Series 2300 Units

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Operating Instructions Models and Hydrostatic Test Pumps

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Miniature controls. Contactors. Overload relays. Starters. Control relays

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

K Page 1 of 48 Air Intake - Pg. 17

ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Pump On Demand. Skimmer System

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Security and confidence at height.

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

TECHNICAL DATA. Trimpac 257a. September 16, 2013

RESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Pressure and Vacuum Switches for Process Applications

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Pressure Dump Valve Service Kit for Series 3000 Units

REPLACEMENT PARTS LIST FOR MODELS:

GM Series Dual-Block Multi-Function Gas Control Valves

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Operating Instructions Model and Hydrostatic Test Pump

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

400C & 450C DUAL PERFORMANCE VALUE PACKS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Pressure switches for air and water CS

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

SPECIFICATIONS ATTENTION

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

High-performance submersible pressure transmitter For level measurement Model LH-10

Boxes & Mounting Accessories 10-1

Flow Measurement Equipment Armored Purge Meters

11. Spare Parts. applications since applications since

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TeSys protection components

IMPORTANT SAFETY INSTRUCTIONS

100C Air Compressor Kit

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

REPLACEMENT PARTS LIST FOR MODELS:

Level transmitter LT 100

444C DUAL PERFORMANCE VALUE PACK

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

MEDICAL EQUIPMENT CATALOG

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Encore PE 50-lb Feed Hopper

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

HORIZONTAL BLADDER TANK

ADAPTABILITY & PRECISION

Valve Proving System VDK 200 A S06*

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Lighting Contactors. 4.1 UL Rated AC Contactors

Aquavar SOLO 2 Frequently Asked Questions

Superstrut. Metal Framing. Surface Raceway and Lighting Systems

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

200 PSI COMPRESSORS - MODEL NUMBERS

HANGERS & SUPPORTS CLIP-IT CLIP-IT STUD STRAPS BAR JOIST CLIP CONDUIT HANGERS CLIP-IT

PVQ 13 A2 R SE 1 S 20 C-11 D

Specifications For Threaded and Butt Weld Hammer Unions

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

MaxSB - Low Voltage Switchboard

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

VERTICAL BLADDER TANK

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

DK ton, Double-acting, Die-type Crimping Tool

Operating Instructions Models and Hydrostatic Test Pumps

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

Operating Instructions Models and Hydrostatic Test Pumps

NHR Powder Feed Hopper

Budget Range Operators Handbook

XCE: Explosionproof Control Enclosures

Crest Heating Boilers FBN(L) Series &

Valve Proving System VDK 200 A S02

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

INSTALLATION INSTRUCTIONS

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Installation Instructions

Pressure switch for gas and air

Inert Air (N2) Systems Manual

Gas Pressure Switch for DMV safety shutoff valves

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

DBML-60/80 Squeeze Tool

Transcription:

. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces control box) LEVEL CONTROLS, WIE ANGLE, PIPE MOUNTE A 10/15

This page intentionally left blank B

Series Adapter Kits 2", 3", 4" and 6" ischarge 9-01000, 2" NPT ischarge 9-001970 9-01300, 2" NPT ischarge inches Includes a 2" NPT x 4" (102mm) Long Galvanized Pipe Nipple, a 1.5" (38mm) NH x 2" NPT Hose Adapter and a 2" NPT Galvanized Pipe Coupling. 9-20000, 2" NPT ischarge 9-250770 9-25000, 2" NPT ischarge 9-55000, 2" NPT ischarge 9-60000, 2" NPT ischarge Includes a 3" (76mm) Victaulic Coupling and a 2" NPT x 8" (203mm) Steel Reducer Nipple. 9-27000, 3" (76mm) ischarge 9-500770 9-35000, 3" (76mm) ischarge 9-50000, 3" (76mm) ischarge 9-60000, 3" (76mm) ischarge Includes a 3" (76mm) Victaulic Coupling and a 3" (76mm) Victaulic x 6" (152mm) Long Galvanized Nipple. 9-81000, 4" (102mm) ischarge 9-815770 9-81500, 4" (102mm) ischarge 9-60000, 4" (102mm) ischarge ESCRIPTION: In-Line suction and discharge is another advantage of PROSSER pumps. It permits series operation where the discharge of one pump is directly connected to the suction of another. The same small diameter casing can be utilized while effectively doubling the head at a given fl ow. Includes a Red 5" (127mm) x 4" (102mm) Victaulic Coupling, a 4" (102mm) x 6" (152mm) Long Galvanized Victaulic Nipple, Quantity of four 3/8-16 x 5.5" (140mm) Long Zinc Plated Cap Screws. 9-82500, 6" (152mm) ischarge 9-840770 9-85000, 6" (152mm) ischarge Includes a 6" (152mm) Cast Iron Victaulic Coupling, a 6" (152mm) x 6" (152mm) Long Galvanized Victaulic Nipple and Quantity of Five 1/2-13 x 5" (127mm) Long Zinc Plated Cap Screws. 1 7/05

Tools Impeller Puller and Seal Installation inches IMPELLER PULLER: PUMP ISCAHRGE SIZE... PART NO. 1.5" 9-100260 2" and 3" 9-500260 4" and 6" 9-840260 IMPELLER PULLER SEAL INSTALLATION Each kit includes a Seal Pusher and a Bullet SEAL BULLET SEAL PUSHER 9-01000 *TL-21354 9-20000 *TL-21355 9-30000 *TL-21355 9-50000 *TL-21355 9-55000 *TL-21357 9-61000 *TL-21357 9-69000 *TL-21356 9-70000 *TL-21356 9-81000 *TL-21357 9-82000 *TL-21358-25 9-85000 *TL-21358-50 (*) Consult Factory 2 7/05

Carrying Handles & Lift Cords inches CARRYING HANLES: 9-01000, *1.50 (38) 615085 9-01300, *1.50 (38) 615085 Includes one 4" Aluminum Handle (*) 1.50-9 American National Fire Hose Coupling Thd. CARRYING HANLE: PART NO. 615085 CARRYING HANLES: 9-20000 9-500771 9-25000 9-27000 9-35000 9-50000 9-55000 Includes one Steel Handle, one 1/2-13 x 2" (51mm) Zinc Plated Cap Screw, two 1/2" (13mm) Zinc Plated Flat Washer and one 1/2-13 Cad Plated Hex Nut. LIFT COR For lifting pumps from well casings, ditches, manholes and vaults. ⅜" Polypropylene yellow rope with SS Snap Ring braided to one end. 25' length..75-2.75hp 112869 CARRYING HANLE: PART NO. 9-500771 3 7/12

Galvanic Protection Kit & Mushroom Strainer Galvanic Protection Kits: For protection against electrolytic action, whether in saltwater or in other reactionary applications. These kits are proven method for protecting the pump against corrosion by using a Zinc Anode fi tted to the pump. PUMP HORSEPOWER...PART NO. 0.75 & 1.0 9-100572 2 thru 5 9-500572 10 thru 50 9-840572 Galvanic Protection Mushroom Strainer: Aluminum, For Series: 9-01000 & 9-01300 Pumps ONLY. 9-01000, 2" NPT ischarge 615058-1 9-01300, 2" NPT ischarge Both the.75hp and 1.0HP are easily fi tted with this strainer which will pump the water level down to within.25" (6mm) of level fl oor. Mushroon Strainer 4 7/05

Sludge Strainer Sludge Strainers: Strainers are Constructed of 300 series Stainless Steel. Strainer kits include, strainer and mounting hardware. PUMP SERIES HP STRAINER P/N A B 9-01000 3/4 9-100000-5XT 4.27 (109) 2.45 (62) 9-01300 1 9-100000-5XT 4.27 (109) 2.45 (62) 9-20000 2 9-500000-5XT 5.20 (132) 3.26 (83) 9-27000 2-3/4 9-500000-5XT 5.20 (132) 3.26 (83) 9-35000 3-1/2 9-500000-5XT 5.20 (132) 3.26 (83) 9-50000 5 9-500000-5XT 5.20 (132) 3.26 (83) 9-55000 5-1/2 9-500000-5XT 5.20 (132) 3.26 (83) 3/4 & 1HP Strainer: P/N: 9-100000-5XT Kit P/N: 9-100000-5XTK 2-5HP Strainer: P/N: 9-500000-5XT Kit P/N: 9-500000-5XTK 5 1/11

This page intentionally left blank 6

NEMA 4 Watertight Pump Control & ual Float Level Control for Standard-Line Pumps (Replaces Standard Pump Control) The combination pump and dual fl oat level control is in a NEMA 4 Watertight enclosure with Manual On-Off switch, circuit breaker with short circuit and overload protection, Magnetic contactor, transformer to reduce line voltage to 24 volt, Two level sensing fl oat switches with cable and fl oat override switch for manual operation. ENCLOSURE...NEMA 4 Watertight, ANSI 61 gray polyester powder coated over phosphatized 14 gauge steel. Stainless steel clamps, continuous hinge and oil-resistant gasket and adhesive assure water tight seal. Aluminum sub-panel for component mounting CIRCUIT BREAKER...For short circuit protection. Thermal-magnetic molded case, permanent trip UL listed, CSA Certifi ed, IEC rated. oor handle is UL/CSA type 4, and can be locked OFF STARTER... Electromechanical. Both HP rated and IEC AC-3 inductive current rated switching device. The insulation rating is 600 volts, and has 15 million operating cycles mechanical durability OVERLOA RELAY... Ambient air compensated class 10 tripping curve device. The insulation rating is 600 volts SWITCH... Hand-Off-Automatic, die cast chrome plated, 22mm TRANSFORMER... Reduces line voltage to 24 volt. 55 C temperature rise FUSE... Transformer primary, rejection type, time delay, 600 volt FUSE... Transformer secondary, dual element time delay, rated for high inrush circuits, rated for 250 volts CAPACITORS...Start & Run, as required for single phase controls WIRING... Color coded, UL listed type MTW or THHN rated for 90 C Float switches are hermetically sealed, single pole, N.O. (Normally Open) Mechanical switch enclosed in a watertight polypropylene casing. Float cables are 18/2 AWG type STO, 600 volt, 60 C, UL and CSA Listed. Temperature limit 122 F (50 C) at 24 PSI (56 ft. of water). Floats are weighted for stabilization. Series: Series: UL 508A.75 thru 3.50HP 1 Ph, 115, 230 Volts.75 thru 50Hp 3 Ph, 230, 460, 575 Volts 7 6/08

NEMA 4 Watertight Pump Control & ual Float Level Control for Standard-Line Pumps (Replaces Standard Pump Control) inches PART NO. PUMP MOEL SINGLE PHASE 115 & 230 VOLTS HP VOLT PH HZ FLOAT CABLE PART NO. PUMP MOEL THREE PHASE 230, 460 & 575 VOLTS HP VOLT PH HZ FLOAT CABLE 100134 9-01012-28FK.75 230 1 60 20 Ft. 100146 9-50135-03 & 04 5 575 3 60 50 Ft. 100134 9-01312-28FK 1.00 230 1 60 20 Ft. 100146 9-55135-03 & 04 5 575 3 60 50 Ft. 100138 9-20111-13 & 14 2.00 115 1 60 50 Ft. 100147 9-81032-03 & 04 10 230 3 60 50 Ft. 100139 9-20112-13 & 14 2.00 230 1 60 50 Ft. 100147 9-81032-23 & 24 10 230 3 60 50 Ft. 100158 9-27112-03 & 04 2.75 230 1 60 50 Ft. 101227 9-81034-03 & 04 10 460 3 60 50 Ft. 100143 9-35112-03 & 04 3.50 230 1 60 50 Ft. 101227 9-81034-23 & 24 10 460 3 60 50 Ft. 100143 9-50112-03 & 04 3.50 230 1 60 50 Ft. 100149 9-81035-03 & 04 10 575 3 60 50 Ft. THREE PHASE 230, 460 & 575 VOLTS 100149 9-81035-23 & 24 10 575 3 60 50 Ft. 100131 9-01032-23FK & 24FK.75 230 3 60 20 Ft. 100150 9-81532-03 & 04 15 230 3 60 50 Ft. 100132 9-01034-23FK & 24FK.75 460 3 60 20 Ft. 100150 9-81532-23 & 24 15 230 3 60 50 Ft. 100132 9-01334-23FK & 24FK 1.00 460 3 60 20 Ft. 100151 9-81534-03 & 04 15 460 3 60 50 Ft. 100133 9-01035-23FK & 24FK.75 575 3 60 20 Ft. 100151 9-81534-23 & 24 15 460 3 60 50 Ft. 100133 9-01335-23FK & 24FK 1.00 575 3 60 20 Ft. 100152 9-81535-03 & 04 15 575 3 60 50 Ft. 100135 9-01332-23FK & 24FK 1.00 230 3 60 20 Ft. 100152 9-81535-23 & 24 15 575 3 60 50 Ft. 100140 9-25132-03 & 04 2.50 230 3 60 50 Ft. 100153 9-82532-33 & 34 25 230 3 60 50 Ft. 100140 9-25132-53 & 54 2.50 230 3 60 50 Ft. 100153 9-82532-43 & 44 25 230 3 60 50 Ft. 100141 9-25134-03 & 04 2.50 460 3 60 50 Ft. 100154 9-82534-33 & 34 25 460 3 60 50 Ft. 100141 9-25134-53 & 54 2.50 460 3 60 50 Ft. 100154 9-82534-43 & 44 25 460 3 60 50 Ft. 100489 9-25135-03 & 04 2.50 575 3 60 50 Ft. 100155 9-82535-33 & 34 25 575 3 60 50 Ft. 100489 9-25135-53 & 54 2.50 575 3 60 50 Ft. 100155 9-82535-43 & 44 25 575 3 60 50 Ft. 100144 9-50132-03 & 04 5 230 3 60 50 Ft. 100156 9-85034-04 & 24 50 460 3 60 50 Ft. 100144 9-55132-03 & 04 5 230 3 60 50 Ft. 100157 9-85035-04 & 24 50 575 3 60 50 Ft. 101226 9-50134-03 & 04 5 460 3 60 50 Ft. 101226 9-55134-03 & 04 5 460 3 60 50 Ft. 8 7/05

NEMA 4 Watertight Pump Control & ual Float Level Control for Standard-Line Pumps (Replaces Standard Pump Control) INSTALLATION INSTRUCTIONS inches ALL SINGLE & THREE PHASE PUMPS (See product chart on page 8) Attach "ON" fl oat to discharge pipe or pump cable at desired pump "ON" level. Attach "OFF" fl oat to discharge pipe or pump cable at desired pump "OFF" level. (Note: The "OFF" fl oat must be below the "ON" fl oat) Hardwire control box to grounded electrical source. Be sure an earth ground is provided from the control. Test to insure satisfactory operation. 9 7/05

Level Controls Mechanical, Wide Angle, Pipe Mounted 115 & 230 Volt w/piggy-back Plug Specifications: inches COR: HOUSING: Material... 14-2 SJOW, 41 Strand x #30, 90 C ry, 60 C Wet Size....37 (8mm) ia. x (See Chart for Lenght) Material... Polypropylene Color... Normally Open - Black CLAMP... Pipe Mounted, Stainless Steel with Polypropylene Saddle, 1" (25) to 3" (76) TEMPERATURE RATING... 200 F (93 C) SWITCH... Mechanical, Snap Action SWITCH RATING... 15 Amps @ 115 Volts AC, 1 Phase 15 Amps @ 230 Volts AC, 1 Phase escription: Part Number 090269 and 090270 Level Controls are available in Pipe Mounted Confi guration with a 115 volt molded on Male and Female Piggy- Back Plug w/ground on the 090269 and a 230 volt molded on plug on 090270. Cable lengths are of 15 (5M), 25 (8M), 30 (9M) and 50 feet (15M). 115 Volt P/N: 090269 The unit has a piggy-back plug attached to the cord, allowing the user to plug the pump plug directly into it, and then plug the entire unit into a 115 volt or 230 volt grounded outlet. The Wide Angle Level Control is furnished with an adjustable strap for mounting to the pump discharge pipe. Standard units are preset at the factory, but can easily be adjusted to various pump down cycles by shortening or lengthening the cord length at the pivot point. The Mechanical level control is a direct acting switch, it uses a metal cylinder sliding back and forth in a tube to actuate a snap-action switch. PART NUMBER COR LENGHT TYPE INSTALLATION CONTACTS 090269 15 ft. (5m), 25 (8m), 30 (9m) & 50 ft. (15m) Pipe Mounted 115 Volt Open 090270 15 ft. (5m), 25 (8m), 30 (9m) & 50 ft. (15m) Pipe Mounted 230 Volt Open STATE COR LENGTH AT TIME OF ORERING. 230 Volt P/N: 090270 10 7/05