IRB Regulation 22 Performance Specification Re-test Field Report

Similar documents
Sport Labs Combining design

Performance Standards for Non-Turf Cricket Pitches Intended for Outdoor Use [TS6] ecb.co.uk

Guide to Artificial Grass Pitches for Community Use. Part 1. Performance Standards for Surfaces and Pitches used Outdoors

ARTIFICIAL GRASS PITCHES FOR RUGBY performance standards and design guides for community use pitches and training areas

ARTIFICIAL GRASS PITCHES FOR RUGBY AND ASSOCIATION FOOTBALL PERFORMANCE STANDARDS AND DESIGN GUIDES FOR COMMUNITY USE PITCHES AND TRAINING AREAS

Venue Name / Location Complex Esportiu - Futbal Salou Report Number R A1. Primary Sport(s) Football

Application as FIFA licensee. for the FIFA Quality Programme for Football Turf

ARTIFICIAL GRASS PITCH INTRODUCTORY GUIDE

Guide to indoor areas for small sided football and disability football

Ground Grading Criteria & Summary

ASBA MULTI-FIELD FACILITY AWARDS APPLICATION. Please complete the following or refer to site plan.

Australian Football League and Cricket Australia Handbook of Testing for Synthetic Turf

FIFA Quality Programme for Football Turf. Handbook of Test Methods October 2015 Edition

The Ground is the total area shown on the plan. The Ground includes:

FACILITY NAME: ASBA SINGLE FIELD FACILITY AWARDS APPLICATION. New Construction Upgrade of Existing Facility. Date of completed project:

Players experiences of artificial turf. Ties Joosten General Manager ISA Sport 7 March 2003

Surfaces for football, rugby, tennis, netball, basketball, hockey etc. Sport Facility Specifications

The purchase of a new artificial turf system TURF TACTICS

HOCKEY TURF & FIELD STANDARDS. Part 1. Introduction & General Guidance 2017 Edition QUALITY PROGRAMME FOR HOCKEY TURF

Standards for football surfaces why different tests?

Surface Test Report. IMPORTANT NOTE: This report does not constitute an ITF Court Pace Classification.

FIFA Quality Programme for Footballs (outdoor, futsal and beach soccer footballs) Testing Manual

BREAK,SHOT,UMPIRE, ETURN,MATCH,BASELIN WHATEVER YOUR GAME, PLAY IT WITH PLAYRITE.

A2:1 The Facility Standards are focused on ensuring appropriate standards for the benefit of the Game including:

ESTABLISHING PERFORMANCE GUIDELINES FOR SPORTS FIELDS IN AUSTRALIA

IN-PLACE DENSITY OF BITUMINOUS MIXES USING THE NUCLEAR MOISTURE-DENSITY GAUGE FOP FOR WAQTC TM 8

GRASS PITCHES FOR RUGBY

ICC ASSOCIATE MEMBERSHIP CRITERIA & GUIDELINES. As at July 2013

NATIONAL GROUND GRADING - CATEGORY H

FACILITY NAME: ASBA TRACK AND FIELD FACILITY AWARDS APPLICATION TRACK PORTION

Installation Operation Maintenance

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

The best alternative to nature

ICOMIA Technical Guideline

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Report No. 371/ This report consists of 6 pages

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

This document is a preview generated by EVS

OCTOBER 2017 ISSUE Page 1 of 7

Instruction Manual Contact Pressure Vacuum Gauge

RSL. Reech Sports. Multi-Use Games Areas. Consult.Design.Build

PROJECT EXAMPLES NATURAL GRASS DEVELOPMENTS

NATIONAL GROUND GRADING - CATEGORY G

Rapidmain Installation Guide

IRFU Age Grade Mini Rugby

SPECIFICATION FOR REPEATED LOAD TRIAXIAL (RLT) TESTING FOR PAVEMENT MATERIALS

NATIONAL COLLEGIATE ATHLETIC ASSOCIATION STANDARD FOR TESTING BASEBALL BAT PERFORMANCE BAT-BALL COEFFICIENT OF RESTITUTION (BBCOR)

BVM CORPORATION TYPE AAX TONG 55,000 FT/LBS. TORQUE Part number: Serial Number:

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

2 Rugby League Turf Care Managers. 3 Maintenance Summary for Rugby League Pitches. 6 Setting & Marking Out: Pitch Sizes

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

CANADIAN RUGBY CHAMPIONSHIP U19 MEN U20 WOMEN July 17 th 22 nd, 2017

High Pressure Iron (HPI) Recertification Guidelines & Procedures

PQ Performance Qualification - Page 1/13

REGULATION 22. STANDARD RELATING TO THE USE OF ARTIFICIAL RUGBY TURF

Smart Water Application Technologies (SWAT) TM

ADA Training Standard Plans

Asphalt Mixture Quality Acceptance

NIOSH Task Number 18388

EKC International FZE. Safety Instructions For Handling & Inspection Manual For Refillable Seamless Steel Gas Cylinders

Item 404 Driving Piling

SUPPORTING NOTES FOR THE EVALUATION OF UNBOUND ROAD BASE AND SUB-BASE AGGREGATES

The Field of Play. Only the lines indicated in Law 1 are to be marked on the field of play.

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

Pressure Measurement Single-range transmitters for general applications

PosiTector UTG, UTG-STD & UTG-ME

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

STRENGTH IN PERFORMANCE

Goals are crucial pieces of equipment. They should be good quality in terms of both playing performance and durability.

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

Newsletter. June /

B A L L R E B O U N D

NATIONAL GROUND GRADING - CATEGORY F

01 18/11/2013 correction of the reference of the product 1 4 5

Miris Ultrasonic Processor

RFU REGULATION 15 AGE GRADE RUGBY

SOCCERPRO THIRD GENERATION ARTIFICIAL TURF

CURI Pierside Stainless Diesel Tank

ICC AFFILIATE MEMBERSHIP CRITERIA & GUIDELINES. As at June 2016

TENSOREX C+ TENSOREX C+

ICC AFFILIATE MEMBERSHIP CRITERIA & GUIDELINES. As at January 2015

Manual Power relay SR853

IRFU Age Grade Rugby

2018 GOLF CLUB & OTHER EQUIPMENT SUBMISSION GUIDELINES

FACILITIES GUIDANCE NOTE 2 GRASS PITCHES FOR RUGBY

ScienceDirect. The player surface interaction of rugby players with 3G artificial turf during rugby specific movements.

PQ Performance Qualification - Page 1/13

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

Pre-filter for Brushless Blower Instruction Manual

Hockey facilities workshop

ON WATER DISPERSIBLE GRANULES (WG)

What is Part 50? The regulations also require operators and contractors to report employment data.

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

Trimax Merlin 320 Mower Trial

James Cronin - Westway Sports Centre

TENNIS COURT REPLACEMENT PROJECT FEB 2017

SILT SCREEN DEPLOYMENT PLAN

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

Calibration Procedure

Guidance on piling, heavy loads, excavations, tunnelling and dewatering

Transcription:

IRB Regulation 22 Performance Specification Re-test Field Report 1. Site Details Site Name: The Connaught School Site Address: Tongham Road, Aldershot, GU12 4AS Site Contact: Martin Sterio Site E-mail: school.office@mail.connaught.hants.sch.uk Site Telephone: 01252 343723 Surface Manufacturer: Co Creation Grass (Rhino Turf) Surface Product ID: VT60 (Stemgrass EX2) Installation Contractor: Kestrel (Contractors) Ltd Installation Contractor Contact: 01256 880488 Date of Completion 01/03/2014 06/01/2017 2. Accredited Test Institute Details IRB Accredited Technician: IRB Accredited Technician E-Mail: Lee Guerriero info@labosport.co.uk IRB Accredited Technician Signature: Laboratory Director: Accredited Test Institute Reference No: Dr Colin Young LSUK.15-0004 3. Test Information Initial Test Date 07/01/2015 Wind Speed (m/s) 0.1m/s Surface Condition Dry X Wet Surface Temperature ( C) Min 7.0 Max 7.4 Ambient Temperature ( C) Min 6.3 Max 7.4 Relative Humidity (%) Min 80.3 Max 82.2 The artificial turf pitch has been tested in accordance with IRB field test requirements as outlined in IRB Regulation 22 Performance Specification for Artificial Rugby Turf (May 2012 Edition). Page 1 of 5

4. Testing Visual Inspection Comment Seams / Joints: Yarn / Pile: Fill Depth: 40mm Irrigation System: Goal Sockets: Goals and Equipment: Line Markings: Maintenance Equipment:* Tractor, brush * Photographic evidence in Appendix C when available 4.1 Plan Showing Surface Irregularities and Dimensions In Goal 5 m broken line 10 m broken line Halfway Line 10 m broken line 5 m broken line In Goal Undulations 10 mm identified on the image in red and slopes 1 % in blue Pitch Dimensions* Goal Line to Goal Line (m) 86.9m Goal Line to Dead Ball Line (m) 0 Touchline to Touchline (m) 50.15 *Please refer to Pitch Measurement of Guidelines in Appendix B Pitch Markings as per IRB Law 1 - The Ground Yes No X Note: The above diagram is used to note the dimensions of the pitch Page 2 of 5

4.2 Test Areas 1-19 Technical Criteria Test position are attached in Appendix A Characteristic Shock Absorption Vertical Deformation Energy Restitution Vertical Ball Rebound Rotational Resistance Head Injury Criteria Requirement 55-70 % 5.5-11.0 mm 20-50 % 0.6-1.0 m 30-45 Nm 1.0 m / Fail PASS PASS PASS PASS PASS PASS Test Position 1 60.2 8.1 33 0.72 38 1.2 Test Position 2 62.2 8.5 32 0.71 36 1.3 Test Position 3 63.1 8.6 32 0.69 39 1.3 Test Position 4 63.9 8.6 33 0.72 34 1.2 Test Position 5 65.2 9.1 30 0.72 37 1.3 Test Position 6 65.1 9.0 31 0.73 35 1.2 Test Position 7 62.5 8.3 32 Test Position 8 62.8 8.3 34 Test Position 9 63.5 8.5 35 Test Position 10 63.5 8.7 36 Test Position 11 64.8 9.0 35 Test Position 12 62.7 8.4 35 Test Position 13 67.1 9.7 30 n/a Test Position 14 64.4 8.8 31 Test Position 15 64.4 8.7 32 Test Position 16 64.5 8.9 31 Test Position 17 63.6 8.6 32 Test Position 18 65.6 9.1 31 Test Position 19 63.6 8.6 31 Please note: These findings relate to the time of inspection only. The inspection does not constitute a formal site safety audit and is carried out as a requirement of the IRB Artificial Rugby Turf Performance Specification (May 2012 edition). The responsibility for the safety of the facility rests fully with the proprietor. Page 3 of 5

4.3 Identification Testing This testing is undertaken to check the Rugby Turf System has not been replaced. Component Rugby Turf Characteristic Pile Length (above backing) Number of Stitches Per 100 mm Site Measurement Manufacturer's Declaration Variation (%) Permitted Tolerance 60 60 0% ± 5 % 13 n/a Stitch Gauge 19.05 n/a / Fail Tufts Per Unit Area 6824 6,825 0% ± 10 % Infill Layer Thickness 40 n/a Performance Particle Size* 2 0.8-2.5 Infill *Sieve retaining at least 10 % Within Range ± 20 % 5. Conclusions: At the time of testing the Artificial Rugby turf pitch at The Connaught School conformed to the requirements of the IRB Regulation 22 Performance Specification (May 2012 edition). 6. Future Testing: IRB Regulation 22 requirements mean a pitch must be retested every two years. This pitch must be retested before 06 January 2017. Page 4 of 5

Appendix A Field of Play with Test Positions 7 12 10 5 8 18 16 68 to 70 m 2 3 4 15 6 19 17 1 13 11 14 9 10* - 22 m 94 to 100 m Appendix B Pitch Measurement Guidelines - see Law 1 Try line to try line: 94 m to 100 m Try line to dead ball line: 10m* to 22 m (absolute minimum length of in-goal area is 6 m) Touchline to touchline: 68 to 70 m Appendix C Maintenance Photographs Page 5 of 5