Inverse Proportional Pressure-Relief Cartridge, Size 10

Similar documents
Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Electrically Operated Pressure-Relief Cartridge, Size 10

Proportional Throttle Cartridges, Size 16

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure-Relief Cartridge Valve, Size 4

Cooler-Bypass Thermostat Valve, Size 16

Double Pilot Operated Cartridge Check Valve, Size 8

Leak-Free Load-Control Valve SAE ½ psi flange

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Leak free Pipe Rupture Valve for Excavators

Leak-Free Load-Control Valve, Size 20

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

3-Way Safety Block DSV

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Safety and Shut-off Block SAF/DSV

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Fixed Displacement Motor A4FM

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

PRESSURE SEQUENCE VALVE TYPE UZK

Check valve hydraulically pilot operated

Safety and Shut-off Block SAF/DSV

Pressure reducing valve, direct operated

Intrinsically safe solenoid valves on/off controls - ATEX certification

The Size 16 Product Range

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure reducing valve, direct operated

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

D62 - D63 Directional Control Valve l/min

Safety and Shut-off Block SAF/DSV

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

Pressure reducing valve, pilot operated

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Cover headline. Cover subheadline. Check Valves

Fixed Displacement Plug-In Motor A2FE

Solenoid valves VZWF, force pilot operated

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Proportional Directional Valve System

SPCH/ Blowing block

Fixed Displacement Motor A4FM

Pressure reducing valve, pilot operated, Model 3DR

Pressure relief valve, direct operated

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

PRESSURE COMPENSATORS TECNORD

Safety and Shut-off Block SAF/DSV

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Description Pressure range Connection thread Device Page

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

[Instruments for vacuum measurement, checking and adjustment] 3

Safety and Shut-off Block SAF/DSV

Series K Air service units G 1/8, G 1/4

Pressure Reducing Valves Catalog Quick Reference

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

4/2 way Pneumatic Solenoid Valve

Cartridge Valves Technical Information Proportional Valves Quick Reference

Directional Controls

Pressure relief valve, direct operated Type DBD

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Air service units series K G1/8, G1/4

Chapter 10: Bidirectional Flow Controls

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Pressure relief valves

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

2-jaw self-centering pneumatic parallel gripper (series SX)

Pressure relief valve, direct operated

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Pressure reducing/relief valve, pilot operated type UZCP10

Applications. What moves your world

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

ASB Accumulator Safety Blocks

Power Valve: Precision Regulator. High precision, large capacity relief regulator

SDM to 8 sections monoblock valve D1WWDA02A

Document How to Set Single Stage Press Pressures

Precision and Instrument Regulators 1/4" port size

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Hand & mechanical directional valves

Transcription:

Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size 1, two stage screw-in cartridges with a M24 x 1.5 mounting thread. They consist of a spool-type main stage and a leak-free, poppet-type pilot stage with a falling pressure/current characteristic. Thanks to the damping of the solenoid armature, these pressure-relief cartridges exhibit excellent stability over the whole pressure and flow range. With these proportional pressure-relief cartridges, the relief pressure is dependent on the electrical control current and can be continuously varied. When the solenoid is de-energised (initial position), the relief pressure is the nominal pressure of the applicable spring range (failsafe function). ny pressure at port is additive to the valve setting at port, therefore port should preferably be connected directly to tank. In control mode, the relief pressure is inversely proportional to the change in the required value (amplifier output current). In order to obtain precise pressure settings over the whole of the required pressure range Compact construction for cavity type DC M24 x 1.5 Excellent stability over the whole pressure and flow range Nominal pressure when solenoid de-energised (fail-safe function) 6 pressure ranges available ll exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available With integral manual pressure setting Can be fitted in a line-mounting body (optimum resolution), the pressure relief cartridges are available in six spring ranges. If a proportional solenoid is faulty, for example, the integral manual pressure setting enables the required pressure to be set mechanically. These proportional pressure-relief cartridges with damping are predominantly used in mobile and industrial applications to allow a pressure in a motor bypass line to be limited electro-proportionally. The cartridges are distinguished by outstanding stability in oscillation-susceptible systems such as fan-drive control circuits. ll external parts of the cartridge are zinc-nickel plated to DIN 5 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 36. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. 2 Symbol 3 Technical data General characteristics Designation Design Mounting method inverse proportional pressure-relief cartridge seated pilot, spool-type main stage, damped design screw-in cartridge M24 x 1.5 Reference: 4-P-58711-EN-2 Issue: 12.216 1/6

General characteristics Tightening torque Size Weight Mounting attitude mbient temperature range 65 Nm ± 1 % nominal size 1, cavity type DC.55 kg unrestricted (preferably vertical, coil down) -25 C +5 C Hydraulic characteristics Maximum operating pressure (p max ) Maximum flow rate Nominal pressure ranges (p N ) Leakage flow rate Flow direction - main port - port 3 bar 25 bar 1) 12 l/min 5 bar, 63 bar, 1 bar, 16 bar, 23 bar, 3 bar.1 l/min = pressure range 5 bar / 63 bar.13 l/min = pressure range 1 bar.16 l/min = pressure range 16 bar.24 l/min = pressure range 23 bar.3 l/min = pressure range 3 bar, see symbols Hydraulic fluid HL and HLP mineral oil to DIN 51 524; for other fluids, please contact UCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 446 : 1999-25 C +7 C 15 38 mm 2 /s (cst), recommended 2...13 mm 2 /s (cst) class 18/16/13 1) To prevent any pressure surges, port must be routed to tank with the least possible back-pressure. ny tank pressure acting at port is additive to the pressure setting at the main port. Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at 2 C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Relative duty cycle Protection class to ISO 2 653 / EN 6 529 Electrical connection 12 V DC, 24 V DC 12 V = 14 m, 24 V = 76 m max. 19 W 12 V = 5.8 / 24 V = 21 12 V = 8.6 / 24 V = 32 2 Hz 2 4 % I N 2 4 % I N < 1 % I N < 2 % p N 1 % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) 3-pin square plug to ISO 44 / DIN 43 65 (standard) for other connectors, see Ordering code 2/6 4-P-58711-EN-2/12.216

4 Performance graphs measured with oil viscosity 33 mm 2 /s (cst) p = f (I) Pressure adjustment characteristic (Q = 5 l/min) 1 8 6 4 2 P187.ai p N 63 bar p N 5 bar p N 1 bar 1 2 2 4 3 6 4 8 5 1 6 12 7 I [m] 14 p = f (Q) Pressure - Flow rate characteristic p N = 5 bar 7 6 5 4 3 2 1 P181.ai 2 4 6 8 1 12 Q [l/min] p = f (Q) Pressure - Flow rate characteristic p N = 1 bar 12 1 8 6 4 2 P183.ai 2 4 6 8 1 12 Q [l/min] p = f (Q) Pressure - Flow rate characteristic p N = 23 bar 3 25 P185.ai p = f (I) Pressure adjustment characteristic (Q = 5 l/min) 3 25 2 15 1 5 P188.ai p N 23 bar p N 16 bar p N 3 bar 1 2 2 4 3 6 4 8 5 1 6 12 7 I [m] 14 p = f (Q) Pressure - Flow rate characteristic p N = 63 bar 8 7 6 5 4 3 2 1 P182.ai 2 4 6 8 1 12 Q [l/min] p = f (Q) Pressure - Flow rate characteristic p N = 16 bar 2 16 12 8 4 P184.ai 2 4 6 8 1 12 Q [l/min] p = f (Q) Pressure - Flow rate characteristic p N = 3 bar 3 25 P186.ai 2 15 1 5 2 4 6 8 1 12 Q [l/min] 2 15 1 5 2 4 6 8 1 12 Q [l/min] 4-P-58711-EN-2/12.216 3/6

5 Dimensions & sectional view, pplication examples 1 V1 2 3 35.5 M24x1.5 2 WK42... 1 4 27 Ma =65 [Nm] ±1% 3 M 132.2 167.7 Ø36 78.4 3 Ma =2.7 [Nm] ±1% 13 Ma =1 [Nm] ±1% 2 Ma =1 [Nm] ±1% 4 56.4 74.4 Reversible fan-drive system Seal kit NR no. DS-298-N 1) Item Qty. Description 1 1 Seal ring 22.1 / 16.5 x 2.5 2 1 O-ring no. 21 23,52 x 1,78 N9 3 2 O-ring 16. x 2. Viton IMPORTNT! 1) Seal kit with FKM (Viton) seals no. DS-298-V Integral air-bleeding If necessary, air can be purged from these proportional pressure-relief cartridges by using the integral air-bleed screw (Item ). The procedure is as follows: Protective cap ir-bleed screw Steps: 1. Remove the protective cap. 2. Slacken the air-bleed screw approx. 2 turns. 3. Switch the pressure-relief cartridge ON/OFF several times until no more air bubbles escape. 4. Tighten the air-bleed screw (Ma = 1 Nm 1%). 5. Fit the protective cap. 4/6 4-P-58711-EN-2/12.216

6 Installation information IMPORTNT! To achieve the proportional pressure-relief cartridge's maximum performance rating, fit the solenoid coil as shown (with the plug pins at the top). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. To prevent any pressure surges, port must be routed to tank with the least possible back-pressure. ny tank pressure acting at port is additive to the pressure setting at the main port. 7 Manual pressure setting These inverse proportional pressure-relief cartridges are equipped as standard with an integral manual pressure setting. If a proportional solenoid is faulty, for example, this manual pressure setting enables the required pressure to be set mechanically. The manual pressure setting can also be used to make minor pressure adjustments directly at the system. IMPORTNT! ny changes to the manual pressure setting have a direct effect on the factory settings. Setting the pressure manually Steps: 1. Remove the protective cap. 2. Slacken the lock nut (13 /F). 3. Unscrew (turn to left) the adjusting spindle (4 /F) until the required pressure is set. 4. Tighten the lock nut (13 /F). 5. Fit the protective cap. C D E E D C 4 Protective cap Lock nut (13 /F) djusting spindle for pressure setting 13 Ma =1 [Nm] ±1 % To reset the inverse proportional pressure-relief cartridges to their initial position (the factory setting), a constant flow rate and a pressure gauge that measures the pressure in the main port are needed. The pressure setting must not exceed the nominal pressure of the spring range in use. The procedure is as follows: Restoring the factory settings Steps: 1. Solenoid de-energised. 2. Remove the protective cap. 3. Slacken the lock nut (13 /F). 4. Unscrew the adjusting spindle (4 /F) to its end-stop, then screw it in until the pressure on the gauge reaches the nominal pressure (pn) of the spring range in use. 5. Tighten the lock nut (13 /F). 6. Fit the protective cap. 4-P-58711-EN-2/12.216 5/6

8 Ordering code D V S - 1 C G - 3-1 _ - 3 24 D _ D = pressure control valve = pressure relief function V = two stage S = standard solenoid (proportional)... Q = standard model - see relevant data sheets Z... R = special features - please consult UCHER 1 = pressure function 1 C = cavity type DC G = proportional solenoid, inverse type (pulling) 3 = pressure range 3 bar 23 = pressure range 23 bar 16 = pressure range 16 bar 1 = pressure range 1 bar 63 = pressure range 63 bar 5 = pressure range 5 bar 1 = nominal size 1 (blank) = NR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact UCHER) 1... 9 = design stage (omit when ordering new units)... = voltage e.g. 24 (24 V) D = current DC (blank) = ISO 44 / DIN 43 65 connection with mating plug (standard, IP 65) M1 = ISO 44 / DIN 43 65 connection without mating plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT4-2P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT4-2P (with protection diode, IP 67/69K) S = MP Superseal 1.5 (IP67) / Metri-Pack 15 (IP65) plug connection F = flying leads (5 mm) 9 Related data sheets Reference (Old no.) Description 4-P-411 (i-32) The form-tool hire programme 4-P-6111 (i-45.1) Cavity type DC 4-P-1211 (W-2.141) Coils for screw-in cartridge valves 4-P-5111 mplifier unit for proportional valves (1-channel) PS - 3 4-P-51111 (P-3) mplifier card, 1-channel for valves with one solenoid, type SN-535 4-P-7411 (G-24.2) Line- and manifold-mounting body, type DC-12 (G 1/2 ) info.ch@bucherhydraulics.com www.bucherhydraulics.com 216 by ucher Hydraulics G Frutigen, CH-3714 Frutigen ll rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. ecause the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 43.35.3.35.32.31 6/6 4-P-58711-EN-2/12.216