Actuators for gas valves

Similar documents
Actuators for gas valves

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

Double gas valves for biogases and recycling gases

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Double valves for biogases and recycling gases

VGD40.../VGD41... Double gas valves. Building Technologies Division

Double gas valves. The VGDs are primarily suitable - On gas-fired combustion plant - In gas trains in connection with forced draft gas burners

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Valves for Biogases and Recycling Gases

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

GM Series Dual-Block Multi-Function Gas Control Valves

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

3-port seat valves with externally threaded connection, PN 16

2-port and 3-port valves PN 16

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Tightness controls TC 1 3 and TC 4

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Pressure switches for air and water CS

Gas Pressure Regulator HON 300

2-Port Seat Valves with Flange, PN 16

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

2-Port Seat Valves with Flange, PN 16

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

VK42.. / VK82.. SERIES

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

2-port and 3-port seat valves, PN16

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

VR46.5V(A)/VR86.5V(A) SERIES

Pressure Regulator 133 / 233

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GM-7000 Series CE Approved Gas Control Valve

Gas Pressure Regulator HON 200

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Old documentation - Only for your information! Product is not available anymore!

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

Gas density monitor With integrated transmitter Model GDM-100-TI

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

JUMO dtrans p30 Pressure Transmitter

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Tightness control TC. Product brochure GB 3 Edition AGA

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

Dual Solenoid Gas Valve Installation

2/2-Way Solenoid Control Valve

OPERATING INSTRUCTIONS

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Controllers DR, DP, FR and DFR

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Pressure independent control valve (PICV) FLOWMATIC

2-port seat valves PN25 with externally threaded connections

Proportional pressure regulators VPPE

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Automatic Valve Proving Control

Gas Pressure Regulator R 51

4/2 way Pneumatic Solenoid Valve

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

High-performance submersible pressure transmitter For level measurement Model LH-20

Pressure Independent Control Series

Two-port seat valves

SINGER MODEL 106/206-RPS-L&H

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

EXH. Specifications. Descriptions. Min. working pressure MPa

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Inverse Proportional Pressure-Relief Cartridge, Size 10

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

High-performance submersible pressure transmitter For level measurement Model LH-20

Compact pressure switches for gas and air

Instruction Manual Contact Pressure Vacuum Gauge

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

2/2-Way Proportional Valve (motor-driven)

Safety Relief Valve HON 832

Transcription:

7 643 Open / Closed Open / Closed with constant pressure governor Open / Closed with differential pressure governor Open / Closed with ratio pressure governor SKP15... SKP25... SKP55... SKP75... Actuators for gas valves SKPx5... Open / closed safety shutoff function conforming to EN 161 in combination with valves supplied by Siemens Damped opening (rapid closing) Very low power consumption Suitable for use with gases of gas families I...III Optionally with / without end switch (factory-set) Plug-in connection facility Electrical indication of operation Valve stroke indication Supplementary Data Sheets on valves (refer to «Use») Models for USA on request The SKPx5 and this Data Sheet are intended for use by OEMs which integrate the actuators in their products.

Use Modular concept Actuators are designed for use with the following types of valves: Type of valve Medium Data Sheet VGG VGF Natural gas Gases of gas families I...III N7636 VGJ Gases of gas families I...III N7650 VGD2 VGD4 VRF Natural gas Gases of gas families I...III Biogas (with SKP15, other actuators on request) N7631 N7633 VLF Hot air N7637 Actuators SKPx5 in general The combination of actuator and valve provides the following functions: - Safety shutoff valve (SKP15) - Safety shutoff valve with gas pressure governor (SKP25, SKP55, SKP75) The electrohydraulic actuators together with the valves are designed for use with gases of gas families I...III and air. They are used primarily on gas-fired combustion plant. The actuators open slowly and close rapidly. The actuator can be supplied with end switch (for indicating the fully closed position). For information about valve sizing, refer to the «Valve sizing chart» in the Data Sheet of the relevant valve. If the actuators are used with gases other than those of gas families I...III, Siemens AG assumes no responsibility for the actuator s durability and life expectancy. All types of actuators can be combined with any of these valves. SKP15 The electrohydraulic operated gas fittings SKP15 together with VGx valves works exclusively as a safety shutoff valve (Open / Closed). They are used primarily on gasfired combustion plant. The actuators open slowly and close rapidly. A valve stroke indication at actuator can only be delivered with end switch. SKP25 The SKP25 operates with a gas pressure governor and controls the gas pressure according to the setpoint preselected with the setpoint spring or air pressure signal. Its field of use is primarily forced draft gas burners - with mechanical air / fuel ratio control (SKP25.0) - with electronic air / fuel ratio control (SKP25.0) - with 2-stage setpoint changeover (SKP25.2) - with proportionate governor (SKP25.3) - with high-pressure control up to 200 kpa (SKP25.4) - with zero pressure governor (SKP25.6) - with constant pressure control, but with electric pressure setpoint adjustment (SKP25.0 with AGA30.7 and SAS) 2/44

Use (cont d) SKP25.0 with AGA30.7 and SAS SKP55 The SKP25.0 with AGA30.7 and SAS solution enables motorized pressure setpoint adjustment for motorized setting or correction of the setpoint for atmospheric and comparable burner operating conditions, typical output modulation multistage or shifting < 1 : 5 not for gas-air ratio combined systems (e.g. class C in accordance with EN 12067-2) SKP25.0 (with AGA30.7 and SAS) must not be used in applications that require mechanical operating conditions higher than class 3M1 (EN 60721-3-3). Vibrations are not permitted. Corrective measures must be implemented on the plant in individual cases. The SKP55 operates with a differential pressure governor and controls a differential gas pressure according to a differential air pressure. The ratio of the differential pressures is 1-to-1 and constant across the entire air range. Its field of use is predominantly - combustion plant with combined heat recovery systems - plant where pressure conditions in the burner and combustion chamber do not change in proportion to load changes - burners with adjustable air / fuel mixing devices in the burner head - plant with negative pressure levels on the gas or air side SKP75 The SKP75 operates as a ratio pressure governor and provides control of the gas pressure depending on the pressure of the combustion air, ensuring that the adjustable gas / air ratio remains constant across the entire load range. Its field of use is primarily modulating forced draft gas burners. Warning notes For additional safety notes, refer inside of Data Sheet! To prevent injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the actuators! Any opening of the actuator, replacement of parts or modifications to the original product is the user s responsibility and carried out at his own risk All activities (mounting, installation and service work, etc.) must be performed by qualified staff When used in connection with gas, the actuators constitute part of the safety equipment Not suitable gases or gas components causes loss of the safety shutoff function Check to ensure that the impulse pipes are correctly fitted and tight (SKP25, SKP55, SKP75) Fall or shock can adversely affect the safety functions. Such actuators must not be put into operation, even if they do not exhibit any damage Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state and make the safety checks as described in «Commissioning notes» If mains voltage is fed to the end switch (CPI), protective earth must be connected to the actuator via the same plug (AGA65) Use of connectors conforming to DIN EN 175301-803-A is mandatory The connectors used must feature cable strain relief Solar radiation or formation of ice are not permitted! SKP25.2 When using SKP25.2, relevant interference suppression measures (EMC) must be implemented on the plant side. The magnet can reach high temperatures if activated for longer periods of time. 3/44

Engineering notes The SKPx5.xx1xx are supplied with the end switch factory-set. Design of the gas train SKP25 If the available gas pressure exceeds the maximum permissible operating pressure of the valve (VGx / VRx) / actuator (refer to the Data Sheet of the relevant valve), it must be lowered by an upstream pressure controller. The pressure switch for lack of gas must always be fitted upstream of the valve when used in combination with the actuator. Installed SKP25s with overpressure protection on the outlet side are switched off and close against the gas pressure. The SKP25 does not require an exhaust line. Β Note! When setting the overpressure limit, ensure it is lower than the load limit for the plant. SKP25, SKP55, SKP75 The impulse pipes must be installed such that the differential pressure can be acquired with no disturbance (unfavorable flow conditions). Pressure test points must not protrude and be flush with the inside diameter of the pipe or duct wall. The impulse lines to the governor should be as short as possible, enabling the governor to respond quickly should sudden load changes occur. The inside diameter of the impulse pipes must be a minimum of 6 mm. In connection with the SKP25, the 1/4 nozzles on the outlet side of the VGx valves can be used as pressure test points (prerequisite: gas control pressure setpoint >1 kpa). SKP75 Installation of impulse pipes: In the case of unsafe combustion chamber pressure pipes (e.g. resulting from potential leaks). The setting must also be checked during operation without having the combustion chamber pipe connected, especially with respect to maximum burner capacity. The impulse pipes must be fitted such that the differential pressure can be acquired with no disturbance. With gas / air ratios >3, the impulse pipes for the combustion air and the combustion chamber pressure must have an inside diameter of at least 8 mm. The impulse pipe for the combustion chamber pressure must be fitted such that the gases will cool down in the vicinity of the impulse pipe and condensing gases cannot enter the governor but will return to the combustion chamber. Warning! If there is a risk of the impulse pipes being exposed to heat, all impulse pipes must be made from suitable metal material Recommendations: The gas pressure should be acquired at a distance of 5 times the nominal pipe size downstream from the valve that the lateral pressure test points on the valve should not be used for picking up the pressure. Considering the combustion chamber pressure: If the resistance value of the combustion chamber / heat exchanger / stack system is constant, the combustion chamber pressure changes in proportion to the gas and combustion air pressure as the burner s output changes. In that case, the combustion chamber pressure need not be fed to the SKP75 as a disturbance variable. However, if the combustion chamber pressure does not change to the same extent as the gas and air pressure as this is the case in plants with flue gas fan or modulating flue gas damper the combustion chamber pressure must be fed to the SKP75 as a disturbance variable, enabling the governor to counteract. If the SKPx5 are operated until the end of their lifecycle, the decreasing drive power can result in a lower gas quantity or gas pressure on the outlet of the gas fitting. If the use requires a minimum pressure behind the gas fitting, the minimum pressure must be monitored 4/44

7643z17e/0404 Mounting notes Ensure that the relevant national safety regulations are complied with The quadratic arrangement of the fixing holes allows the actuator to be fitted in 4 different positions on the VGx valve, each step being 0 (depending on the type of VGx valve) The actuator can be mounted or replaced while the system is under pressure; sealing material is not required SKP25 / SKP55 / SKP75: SKPx5 with pressure control function have a vent opening on the pressure governor. Measures must be taken in the application to prevent the vent opening from being blocked Warning! Condensation, formation of ice and ingress of water are not permitted. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock. Follow the Mounting Instructions included with the actuators: Sealing / tightness Actuators in general Type reference Mounting instruction SKP15 M7643 (74 31 0420 0) SKP25 M7643 (A5W00000658) SKP25 with AGA30.7 and SAS M7643.4 (74 31 0552 0) SKP55 M7643 (74 31 0420 0) SKP75 M7643 (74 31 0420 0) AGA66-IP65-Kit for SKPx5 / VGx M7643.2 (74 31 0421 0) Check the tightness when all components are connected Electrical commissioning may only be performed when the actuator is fitted to the valve; otherwise, the actuator can be damaged Power is supplied and connection of the end switch is made directly via a connecting cable (conforming to DIN EN 175301-803-A) The end switch is factory-set The pump s stem must not be pulled out using the over stroke element since that part could become loose Do not pull here! 5/44

Installation and commissioning notes Functioning principle of 1-stage actuator SKP15 with safety shutoff feature When power is applied, the pump will be activated and the control valve closed. Oil is now pumped from the chamber below the piston to the stroke chamber above the piston. The oil pressure causes the piston to move downward, thereby opening the valve against the pressure of the closing spring. The pump remains energized until the closing command is given. When power is removed, or in the event of a power failure, the pump will be deactivated and the control valve opened so that the closing spring pushes the piston back. The return flow system is sized such that the counterstroke required for reaching the fully closed position is completed within about 0.6 seconds. SKP15 complete with valve (Schematic drawing) 4 Legend SKP15... 1 2 7 3 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valve s closing spring 7 Control valve 8 End switch (optional) 8 5 Valve 7643z2e/0608 pe 6 6/44

Installation and commissioning notes (cont d) SKP25, SKP55 and SKP75 The functioning principle (safety shutoff feature) is identical to that of the SKP15, but with the help of their pneumatic governor, the SKP25, SKP55 and SKP75 also control a bypass valve in the hydraulic circuit and thus the valve s opening position. SKP25 complete with valve (Schematic drawing) Legend Air 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valve s closing spring 7 Control valve 8 End switch (optional) Spring (setpoint adjustment) 10 Bypass valve pe 7643z53en/0415 SKP25 Setpoint adjustment «PGas» is made manually by turning the setting screw, which acts on the setpoint spring (for setpoint springs, refer to «Accessories»). PGas Legend 7643d03/0107 t (Pe; V) Pe V PGas Inlet pressure Volumetric flow 0...2,2 kpa (with built-in AGA2 standard spring), presetting 1,5 kpa 7/44

Installation and commissioning notes (cont d) SKP25.3 The SKP25.3 operates based on the proportionate pressure principle «PL» : «PG» = 1:1. By feeding fan pressure «PL» to the air connection, gas pressure «PGas» follows in a fixed 1-to-1 ratio. C A Gas / air ratio for stoichiometric combustion +0.1 kpa B / C The governor permits one parallel displacement in both directions: «gas pressure lowering» B and «gas pressure elevation» C Β Note! Fit cap again before measuring the combustion value and after the setting is made. SKP25.6 SKP25.6 zero pressure governor works like SKP25.3, but enabled a larger parallel displacement towards gas pressure lowering. PGas [kpa] Legend 0 VGas [m 3/h] V Volumetric flow PGas Offset spring 0...0, kpa 0 Atmospheric pressure - 8/44

Installation and commissioning notes (continued) SKP25 with AGA30.7 and SAS The SKP25.0 (with AGA30.7 and SAS) operates like the SKP25 constant pressure governor, but features electromotoric adjustment of the setpoint spring. It is used primarily in atmospheric or comparable burners in modulating or multistage operation individual burners or groups of burners on industrial furnaces (gas pressure correction and disturbance variable compensation) not approved for gas-air ratio combined solutions (e.g. class C in accordance with EN 12067-2) SKP25.0 complete with valve (simplified sectional view) Air pe 7643z54en/0116 Key 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Closing spring of valve 7 Control valve 8 End switch (optional) Position indication 10 Bypass valve /44

Installation and commissioning notes (continued) Setting example: The low-fire pressure value (offset) is adjusted by screwing in the AGA30.7 on SKP25.0. The maximum high-fire limitation (maximum pressure (PGmax)) is set with the stem of the SAS extended via the lock nut on AGA30.7. The desired pressure ranges (up to 32 kpa) are determined by use of the setpoint springs (AGA22, AGA23, 742150040). Β Note! See Mounting Instructions A5W00000658 (M7643). Functioning principle of the gas pressure governor with SAS motorized setpoint adjuster: On the gas outlet side, the gas pressure governor maintains the pressure at the required setpoint. An electric signal on the SAS changes the specified setpoint (PR) proportionally. If the SAS motor stops, the outlet pressure remains constant. ^ 7643d14en/0116 SAS Different SAS motors can be used depending on the required function (e.g. electric control signal), see Data Sheet N4581. 10/44

Installation and commissioning notes (cont d) SKP25.2 The SKP25.2 features 2-stage setpoint changeover for 2-stage gas burners. Assembly of SKP25.2 complete with valve Activation stage 2 11 10 (Schematic drawing) Connection Pc Throttle AGA25.2 12 DC magnet stage 2 Activation stage 1 SKP25.2... 8 PGas 4 1 2 7 3 5 Legend 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valve s closing spring e 7 Control valve 8 End switch (optional) Bypass valve 10 High-fire screw (stage 2) 11 Low-fire screw (stage 1) 12 AGA25.2 damping throttle - Connection for combustion chamber pressure PC (recommended in case of PGas stage 1 <0,3 kpa) - If PC is not connected, a damping throttle AGA25.2 must be fitted if Pe >2 kpa (application test) Valve pe 7643z37en/0718 6 11/44

Installation and commissioning notes (cont d) Setpoint adjustment «PGas» is made manually by turning the setting screws (10 and 11), which act on the setpoint spring. PGas High-fire (stage 2) SKP25.2: max. 6 kpa SKP25.2...L: max. 2 kpa Low-fire (stage 1) >0.2 kpa Setting example: 1. Set the low-fire load (stage 1): Set the low-fire screw (11) to the required pressure value (Ο +PGas). 2. Set the high-fire (stage 2): Activate stage 2 and set the high-fire screw (10) to the required pressure value (Ο +PGas). 3. After setting the high-fire, the low-fire load need be readjusted. Every high-fire setting / readjustment changes the low-fire setting! Β Note! Refer to Mounting Instructions M7643.4 (74 31 0552 0) Default settings: Low-fire: 1,2 kpa / high-fire: 5,5 kpa 12/44

Installation and commissioning notes (cont d) SKP25.4 ¹) SKP25.4 is designed to manage higher pressures of up to 200 kpa (EN88-2:AC5; EN 88-2:SG10, and ISO 23551-2). ¹)Β Note! Not approved as a safety shutoff valve (SAV). SKP25.4 complete with valve 11 (Schematic drawing) Legend 12 Air SKP25.4... 8 PGas 4 1 10 2 7 3 5 Connection variant 1 Connection variant 2 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valve s closing spring 7 Control valve 8 End switch (optional) Spring (setpoint adjustment) 10 Bypass valve 11 PAir connection Optional: AGA25.2 damping throttle 12 Setting screw (setpoint adjustment) pe Valve (e.g., VGJ) 6 7643z64en/0718 13/44

Installation and commissioning notes (cont d) Setpoint adjustment «PGas» is made manually by turning the setting screw, which acts on the setpoint spring (for setpoint springs, also refer to «Accessories»). PGas Legend 7643d03/0107 t (Pe; V) Pe V PGas Inlet pressure Volumetric flow 7...200 kpa depending on the setpoint spring, see Accessories (with built-in standard spring AGA23), presetting 120 kpa Pressure range (kpa) Setpoint spring Setpoint spring with fine adjustment 7...70 AGA22 AGA30.0 15...150 AGA23 AGA30.1 20...200 --- AGA30.2 14/44

Installation and commissioning notes (cont d) SKP55 The SKP55 operates with a differential pressure governor and a fixed differential pressure ratio of 1-to-1. SKP55 complete with valve (Schematic drawing) Legend Air 10 PGas 4 1 2 7 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valve s closing spring 7 Control valve 8 End switch (optional) Spring (setpoint adjustment) 10 Bypass valve SKP55... 3 8 5 Valve pe 7643z32e/0608 6 VG / PG 1+ Example: Adjusted gas / air ratio for burner operation with gas pressure elevation 1+. The percentage of gas pressure lowering is constant across the entire load range. Gas / air ratio adjustment with the adjustable orifice on the gas side (see positionâ). 1-7643d01/1004 VL/ PL Legend VL VG Volumetric air flow Volumetric gas flow 15/44

7643z12/1204 7643z01e/1204 Installation and commissioning notes (cont d) Air VL 8 M pl 11 A SKP55.../V... 3 - + 2 1 + B B - Gas 5 + - 4 7 10 VG pg Safety notes: Arrangement air damperà / orifice 11 must always be located as shown, which means that orifice 11 must be installed downstream from the air damperà. Arrangement valve 10 (VGx) / orificeâ must always be located as shown, which means that orificeâ must be installed downstream from the valve 10. 2 1 12 6 10 4 3 5 Å Ç É Ñ Ö Ü á à â Adjustment of parallel displacement of working characteristic * Check combustion values with cap fitted Test point for air pressure (+) Test point for air pressure (-) Test point for gas pressure (-) Test point for gas pressure (+) Valve stroke indication Spring (parallel displacement) Actuating device (air) Orifice (gas) 10 Valve 11 Orifice (air) 12 Indication of operating state (LED) Legend ΧpG Differential pressure across orifice on the gas side ΧpL Differential pressure across orifice on the air side A Air heating coil (recuperator) B Burner M Actuator 16/44

Installation and commissioning notes (cont d) SKP55 Β Adjustment of governor on modulating burners prior to startup: Setting screwå on the SKP55 should be set to a gas / air ratio curve which passes through the neutral point. The SKP55 is supplied with that factory setting. Adjustment in the field can be made as follows: Note: Fit cap again before measuring the combustion value and after the setting is made. Turn setting screw Å in counterclockwise direction until spring á is completely loose. Shut off the gas supply upstream of the SKP55. Switch on the SKP55. Turn setting screwå in clockwise direction until valve opens Bring the adjustable orificeâ to the precalculated value. That value with the same pressure differential on the air and gas side must lead to practically stoichiometric combustion Start the burner and run it to about 0 % of the high-fire Measure the combustion quality and make adjustments of the flow rate with the adjustable orificeâ until optimum measured values are reached (fine adjustment) Return to low-fire operation. Check the combustion and readjust if necessary the position of the working characteristic with the setting screw Å on the SKP55 until optimum measured values are reached. Clockwise rotation more gas. Counterclockwise rotation less gas, that is, parallel displacement of the working characteristic towards gas pressure elevation or gas pressure lowering Limit the air damperà for low-fire operation If a significant parallel displacement of the working characteristic was required, the setting must be checked again at 0 % of the high-fire and then readjusted, if required Run the burner to the predefined high-fire with the help of the air damperà and limit the actuator position for that load Check the flue gas values at a few positions of the load range. Make readjustments in the high-fire range with the adjustable orificeâ, and in the low-fire range with setting screwå on the governor of the SKP55. 17/44

Installation and commissioning notes (cont d) SKP75 The SKP75 operates with a ratio pressure governor and an adjustable gas / air ratio. SKP75 complete with valve (Schematic drawing) Air SKP75... PGas 4 1 2 7 Legend 1 Piston 2 Oscillating pump 3 Oil reservoir 4 Pressure side 5 Stem 6 Valves closing spring 7 Control valve 8 End switch (optional) Bypass valve 3 8 5 > 6 mm Valve pe min. 5d 7643z33e/0407 6 Adjustment of governor on modulating burners Use setting screwå / «PGAS» / «PAIR» to set the gas / air ratio to the required value (coarse setting) and the scale with setting screwç to zero (refer to Fig. 7643z03) Start the burner and run it to about 0 % of the high-fire Measure the CO2 or O2 content of the flue gases and optimize the adjustment with setting screwå / «PGAS» / «PAIR» (refer to Fig. 7643z03) Return to low-fire operation, check the CO2 or O2 content of the flue gases. If necessary, readjust position of the working characteristic with setting screwç/ until optimum measured values are attained Limit the air damper position for low-fire operation Meaning of setting screw markings: + More gas - Less gas 18/44

Installation and commissioning notes (cont d) If a significant parallel displacement of the working characteristic was required to obtain optimum CO2 or O2 values in low-fire operation, the adjustment of the pressure ratio at high-fire or 0 % of the high-fire must be checked again and readjusted, if required. Run the burner to the required output and limit the high-fire air damper position Check the flue gas values at various positions of the load range If readjustments are required: - Use setting screwå / «PGAS» / «PAIR» in the high-fire range - Use setting screwç/ to make parallel displacements of the characteristic in the flow-fire range If the gas / air pressure ratio lies outside the setting range, an orifice in the gas or air flow can be used to adjust the pressure at the test points on the burner side. Prerequisite is that there is a sufficient gas or air pressure reserve on the inlet side. PGas (pg) M ~ pa C B A M pa pc B C SKP75... 0,4 - + 1 2 7643d07e/0407 PAir (pa) pe pg 7643z03/0304 VG... Å Setting and display of the gas / air ratio 1 2 Setting and display of parallel displacement of the Ç working characteristic 3 É Test point for combustion chamber pressure Ñ Test point for air pressure Ö Test point for gas pressure Ü Valve stroke indication á Operation indicator (LED) à Valve 4 7 5 6 8 1/44

Installation and commissioning notes (cont d) Function If the air pressure (fan pressure) exceeds the maximum value of 3 kpa with a PGas / PAir ratio of 2 5 kpa with a PGas / PAir ratio of 2 permitted for the governor, the pressure must be lowered with a reducing T-piece AGA78 (also refer to «Technical data»). P1 130 120 110 100 0 80 70 60 50 40 30 20 D1 = 1,5 mm; D2 = 2 mm D1 = 1,5 mm; D2 = 1,7 mm 7643d02/0503 Example: p1 = 7 kpa D1 = 1.5 mm D2 = 1.7 mm Wanted: Air pressure signal «p2» for SKP75 p2 = 2,6 kpa 10 10 20 30 P2 Air is continuously vented to atmosphere via orifice «D2». The pressure of the following medium will be reduced via throttle «D1». The illustration below shows the correlations. The reducing T-piece AGA78 is supplied ready for mounting, with D1 = 1.5 mm and D2 = 1.7 mm. D2 with a diameter of 2 mm is included as a loose item. 20/44

Standards and certificates In combination with VGx Applied directives: Low-voltage directive 2006/5/EC Directive for pressure devices 2014/68/EU Gas Appliances Regulation (EU) (EU) 2016/426 Electromagnetic compatibility EMC (immunity) *) 2014/30/EU *) Compliance with EMC emissions requirements must be checked after the actuator has been installed in the work equipment Compliance with the regulations of the applied directives is verified by the adherence to the following standards / regulations: Pressure regulators and associated safety devices for gas DIN EN 88-1 appliances Part 1: Pressure regulators for inlet pressures up to and including 50 kpa SKP25.4 only DIN EN 88-2 Pressure regulators and associated safety devices for gas appliances Part 2: Pressure regulators for inlet pressures above 500 mbar up to and including 5 bar Multifunctional controls for gas burning appliances DIN EN 126 Automatic shut-off valves for gas burners and gas DIN EN 161 appliances Safety and control devices for gas burners and gas DIN EN 13611 burning appliances Automatic electrical controls for household and similar use Part 1: General requirements DIN EN 60730-1 The relevant valid edition of the standards can be found in the declaration of conformity! EAC Conformity mark (Eurasian Conformity mark) ISO 001:2015 ISO 14001:2015 OHSAS 18001:2007 China RoHS Hazardous substances table: http://www.siemens.com/download?a6v10883536 For use in the U.S. / Canada, the actuators carry type suffix «U» (see example) and are, and -listed (Example: SKP25.003U1, refer to separate Data Sheet [on request]). 21/44

Life cycle The combination valve and actuator have a designed lifetime* of Nominal size 25 DN 200.000 25...80 DN 100.000 80...150 DN 50.000 Burner startup cycles which, under use of gases to EN 437 (or DVGW specification G260). This lifetime is based on the endurance tests in the standard EN 161. A summary of the conditions has been published by the European Control Manufacturers Association (Afecor) (www.afecor.org). The designed lifetime is based on use of the valve and actuator according to the manufacturer s Data Sheet. When reaching the designed lifetime in terms of the number of burner startup cycles or the respective time of usage, valve and actuator must be checked by authorized personnel and, if necessary, replaced. * The designed lifetime is not the warranty time specified in the Terms of Delivery. Disposal notes The actuator contains electrical and electronic components and hydraulic oil and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. Type summary (other types of actuators on request) SKP15 The complete gas shutoff assembly or pressure governor assembly consists of actuator and valve. Article no. Type Article no. Type Mains voltage AC 120 V AC 230 V 1-stage opening and closing, without end switch, without valve stroke indication 1-stage opening and closing, with end switch, with valve stroke display BPZ:SKP15.000E1 SKP15.000E1 BPZ:SKP15.000E2 SKP15.000E2 BPZ:SKP15.001E1 SKP15.001E1 BPZ:SKP15.001E2 SKP15.001E2 22/44

Type summary (other types of actuators on request) The complete gas shutoff assembly or pressure governor assembly consists of actuator and valve. SKP25 Article no. Type Article no. Type Mains voltage AC 120 V AC 230 V 1-stage opening and closing, with end switch, with pressure governor up to 2,2 kpa, other pressure ranges via change setpoint spring possible refer to accessories 1-stage opening and closing, without end switch, with pressure governor up to 2,2 kpa, other pressure ranges via change setpoint spring possible refer to accessories 1-stage opening and closing, without end switch, with pressure governor up to 2,2 kpa, other pressure ranges via change setpoint spring possible, with integrated damping throttle AGA25.2 refer to Accessories 2-stage opening and closing, with end switch, with pressure governor up to 6 kpa 2-stage opening and closing, without end switch, with pressure governor up to 2 kpa 2-stage opening and closing, without end switch, with pressure governor up to 6 kpa 2-stage opening and closing, without end switch, with pressure governor up to 2 kpa 1-stage opening and closing, with end switch, with stroke indication, proportionate governor version 1-stage opening and closing, without end switch, proportionate governor version 1-stage opening and closing, with end switch, with pressure governor up to 150 kpa, high-pressure version, other pressure ranges via change setpoint spring possible refer to accessories 1-stage opening and closing, without end switch, with pressure governor up to 150 kpa, high-pressure version, other pressure ranges via change setpoint spring possible refer to accessories 1-stage opening and closing, with end switch, for zero pressure governor version 1-stage opening and closing, without end switch, for zero pressure governor version BPZ:SKP25.001E1 ²) SKP25.001E1 ²) BPZ:SKP25.001E2 ²) SKP25.001E2 ²) BPZ:SKP25.003E1 ²) SKP25.003E1 ²) BPZ:SKP25.003E2 ²) SKP25.003E2 ²) --- --- BPZ:SKP25.003E2Y SKP25.003E2Y BPZ:SKP25.201E1 SKP25.201E1 BPZ:SKP25.201E2 SKP25.201E2 BPZ:SKP25.201E1L SKP25.201E1L BPZ:SKP25.201E2L SKP25.201E2L --- --- BPZ:SKP25.203E2 SKP25.203E2 --- --- BPZ:SKP25.203E2L SKP25.203E2L --- --- BPZ:SKP25.301E2 *) SKP25.301E2 *) --- --- BPZ:SKP25.303E2 SKP25.303E2 BPZ:SKP25.401E1 ³) SKP25.401E1 ³) BPZ:SKP25.401E2 ³)*) SKP25.401E2 ³)*) BPZ:SKP25.403E1 ³) SKP25.403E1 ³) BPZ:SKP25.403E2 ³) SKP25.403E2 ³) --- --- BPZ:SKP25.601E2 *) SKP25.601E2 *) --- --- BPZ:SKP25.603E2 *) SKP25.603E2 *) ¹) Factory setting 1,5 kpa ²) Factory setting 120 kpa *) On request 23/44

Type summary (other types of actuators on request) SKP55 Article no. Type Article no. Type Mains voltage AC 120 V AC 230 V 1-stage opening and closing, with end switch, with differential pressure governor 1-stage opening and closing, without end switch, with differential pressure governor BPZ:SKP55.001E1 SKP55.001E1 BPZ:SKP55.001E2 SKP55.001E2 BPZ:SKP55.003E1 SKP55.003E1 BPZ:SKP55.003E2 SKP55.003E2 SKP75 Article no. Type Article no. Type Mains voltage AC 120 V AC 230 V 1-stage opening and closing, with end switch, with ratio pressure governor 1-stage opening and closing, without end switch, with ratio pressure governor 1-stage opening and closing, with end switch, with ratio pressure governor, with greater parallel displacement 1-stage opening and closing, without end switch, with ratio pressure governor, with greater parallel displacement BPZ:SKP75.001E1 SKP75.001E1 BPZ:SKP75.001E2 SKP75.001E2 BPZ:SKP75.003E1 SKP75.003E1 BPZ:SKP75.003E2 SKP75.003E2 --- --- BPZ:SKP75.501E2 SKP75.501E2 BPZ:SKP75.503E1 SKP75.503E1 BPZ:SKP75.503E2 SKP75.503E2 ²) Factory setting 1,5 kpa 24/44

Ordering examples When ordering, please give the complete type reference of the actuator (refer to «Type summary»). All components must be ordered as separate items. Example of SKP15 Actuator with safety shutoff function - Open / closed - With end switch - For AC 230 V / 50 Hz SKP15.001E2 Connector valve actuator (plug) AGA64 Connector end switch (plug) AGA65 Combination of actuator / valve consisting of: - Valve - SKP15.001E2 actuator - Accessories Please order the required valves as separate items (refer to the relevant Data Sheets). Actuator and valve are supplied unassembled. Assembly is very straightforward and preferably made on the burner. Example of SKP25 Gas pressure governor with safety shutoff function: - Without end switch - For AC 230 V / 50 Hz SKP25.003E2 Connector valve actuator (plug) AGA64 Combination of gas pressure governor / valve consisting of: - Valve - SKP25.003E2 actuator 25/44

7643z4e/0407 Accessories (not supplied as standard, to be ordered as separate items) Adapter plug AGA62.000A000 Article no.: BPZ:AGA62.000A000 For powering both actuators on the double valve VGD via plug (AGA64) Example: SKP15 / SKP25.2 with adapter plug AGA62.000A000 Central connection via AGA64 for the separate control of valves 1 and valves 2 Facilitates valve prooving via pressure switch between the valves or ignition via pilot burner V1 V2 Heating element Refer to Data Sheet N723 For use at low ambient temperatures (< -10...-20 C) AGA63.5A27 Article no.: BPZ:AGA63.5A27 26/44

7643z50e/0407 Accessories (not supplied as standard, to be ordered as separate items) (cont d) Contact box for valve actuator (power supply) Plug-in connector conforming to DIN EN 175301-803-A 3 pole + Dia. 6... mm / max. 1.5 mm² AGA64 Article no.: BPZ:AGA64 Example: SKP15 / SKP25 with contact box AGA64 Contact box for end switch Plug-in connector conforming to DIN EN 175301-803-A 3 pole + Dia. 4.5...11 mm / max. 1.5 mm² AGA65 Article no.: BPZ:AGA65 Example: SKP15 / SKP75 with contact box AGA65 Contact box end switch AGA65 V1 V2 27/44

7643z48e/0407 7643z47e/0407 Accessories (not supplied as standard, to be ordered as separate items) (cont d) Contact box For powering the magnetic actuator SKP25.2 Plug-in connector conforming to DIN EN 175301-803-A With integrated bridge rectifier 2 pole + Dia. 6...8 mm / max. 1.5 mm² Including profile seal AGA67 Article no.: BPZ:AGA67 Example: SKP15 / SKP25 with contact box AGA67 Contact box AGA67 V1 V2 Adapter plug for AGA62.000A000 For common valve control AGA68 Article no.: BPZ:AGA68 Example: SKP15 / SKP25 with adapter plug AGA68 Adapter plug AGA68 PE V1 V2 N LV1 LV2 Bridge 28/44

Accessories (not supplied as standard, to be ordered as separate items) (cont d) Article no. Type Motorized setpoint adjuster for SKP25.0 For 5.5 mm stroke See Data Sheet N4581 and Mounting Instructions A5W00000658 (M7643) SAS... Adaptation to SKP25 For motor pressure correction in conjunction with motorized setpoint adjuster SAS. For more details, refer to Mounting Instructions A5W00000658. Setpoint spring (black) for AGA30.7 for SKP25 0.5...3.5 kpa Refer to Mounting Instructions A5W00000658 S55851-Z401-A100 AGA30.7 S55851-Z301-A100 AGA21 Setpoint spring (yellow / gold) for SKP25 Optional for built-in standard spring AGA2 1,5...12 kpa at SKP25.0 7 70 kpa at SKP25.4 (optional for AGA23) Setpoint spring (red) for SKP25 Optional for built-in standard spring AGA2 10...25 kpa at SKP25.0 15...150 kpa at standard spring SKP25.4 BPZ:AGA22 BPZ:AGA23 AGA22 AGA23 Setpoint spring (copper) for AGA30.7 for SKP25 0.2...5.5 kpa Refer to Mounting Instructions A5W00000658 S55851-Z302-A100 AGA26 Setpoint spring (blank) for SKP25.3 Equivalent built-in standard spring ±0,15 kpa Setpoint spring (blank) for SKP25.0 Equivalent built-in standard spring 0,05...2,2 kpa Setpoint spring (blank) for SKP25.4 10...36 kpa Order no.: 742150040 Refer to Mounting Instructions 74 31 026 0 BPZ:AGA28 BPZ:AGA2 BPZ:AGA30.2 AGA28 AGA2 AGA30.2 Damping throttle for SKP25 Optional BPZ:AGA25.2 AGA25.2 Damping throttle for SKP55 / SKP75 Optional, pipe connection for 6 mm dia. Refer to Mounting Instructions 4 31 2078 0 BPZ:AGA75 AGA75 2/44

7643z45e/0407 Accessories (not supplied as standard, to be ordered as separate items) (cont d) Article no. Type Pressure reducing-t-piece for SKP75 Optional BPZ:AGA78 AGA78 Distance piece Seal Gasket set AGA66 Article no.: BPZ:AGA66 For mounting between actuator and valve (VGx / VRx) Increases degree of protection from IP54 to IP65 When using VGG single valves, observe Data Sheet N7636 Refer to Mounting Instructions M7643.2 (74 31 0421 0) Setpoint fine adjustment to SKP25 Packaging version with one setpoint spring each See Mounting Instructions M7643 (74 31 026 0) AGA30... Article no. Type 1.5...12 kpa Color: Yellow 1 BPZ:AGA30.0 AGA30.0 Setpoint spring 10...25 kpa Color: Red 2 BPZ:AGA30.1 AGA30.1 10...36 kpa Color: Blank 3 BPZ:AGA30.2 AGA30.2 7643z18/015 1 2 3 30/44

Technical Data Β Note! All typical technical information applies to nominal conditions. General unit data Mains voltage - Europe SKPx5.xxxE2 AC 230 V 15%/+10% SKPx5.xxxE1 AC 120 V 15%/+10% - Japan SKPx5.xxxF1 AC 100 V 15%/+10% SKPx5.xxxF2 AC 200 V 7%/+10% Mains frequency - Europe 50 / 60 Hz 6% - Japan 60 Hz 6% Power consumption Protection 1 A slow European SKPx5.xxxEx Max. 10 VA SKP25.xxxEx Max. 35 VA (in stage 2) Japan SKPx5.xxxFx Max. 13 VA Closing time SKPx5 <1 s (at shutdown) Required time interval load change carried via air / fuel ration pressure between highfire and low-fire SKP25.3 / SKP55 / SKP75 Min. 4 s (depending on valve stroke) Safety class I Degree of protection SKPx5 IP54 only ensured when central screw at the connector is tightened IP65 only with gasket kit AGA66 SKP25 / SKP55 only with screwed-on locking caps Β Note! Degree of protection IP54 and IP65 only possible with mounted connectors. Group 1 In accordance with DIN EN 88-1 Pollution degree 2 Rated surge voltage Overvoltage category III in accordance with DIN EN 60730-1 Mode of operation Automatic controller and control unit: Type 2C Design of the controller and control unit Integrated controller and control unit Control class A to DIN EN 88-1 SKP25.4 Accuracy class In accordance with EN 88-2:AC5 Closing pressure class In accordance with EN 88-2:SG10 Control accuracy SKP25.3 / SKP75 <10 % at «Χpmin», <2 % at «Χpmax» SKP55 Pressure impulse SKPx5 <10 % at «Χpmin», <1 % at «Χpmax» Static compressive strength as with valve VGx 31/44

Technical Data (cont d) Control variable gas pressure SKP25.0 SKP25.2 SKP25.2xxxxL SKP25.3 SKP25.4 SKP25.6 SKP55 SKP75 / SKP75.5 0,05...25 kpa (3 setpoint springs) 0,2...6 kpa 0,2...2 kpa 0,05...5 kpa 7...200 kpa (3 setpoint springs) <0 kpa (atmosphere) Difference pressure PG+ / PG- 0,03...20 kpa Difference pressure PG-PF or PG-PAir 0,08...12 kpa Absolute / difference pressure of combustion air (reference variable) SKP25.3 SKP55 SKP75 / SKP75.5 0.05...7.5 kpa Difference pressure PL+ / PL- 0,03...20 kpa PAir-PCombustion space >0,05 kpa Air pressure / difference pressure - at «PGas / PAir» 2 Max. 3 kpa - at «PGas / PAir» 2 Max. 5 kpa - Upper pressures refer to AGA78 Max. 15 kpa «Accessories» Difference pressure ratio (gas / air) adjustable SKP25.3 / SKP55 1:1 SKP75 / SKP75.5 0,4... (Factory supplied 1.3) Permissible combustion space pressure SKP75 3 kpa Parallel translation PGas SKP25.3 / SKP55 ±0,1 kpa SKP25.6 0 kpa/-0, kpa SKP75 ±0,1 kpa (Factory supplied 0) SKP75.5 +0,1 kpa/-0,45 kpa (Factory supplied 0) Position switch (if built-in) As closed position switch factory-made justified Position valve CLOSED or OPEN - Switching load 4 A (2 A, cosι = 0.3) Protection 6 A slow Notice! Safety extra-low voltage may not be connected. If this is not observed, there will be a risk of electric shock! 32/44

Technical Data (cont d) On-time 100 % Opening speed, typical (approx. 2 mm/s) Lower opening speeds due to low ambient temperatures can be compensated by fitting an AGA63.5A27 heating element Permissible mounting positions 7643z07/0603 Always with the diaphragms in the vertical position 33/44

Technical Data (cont d) Weight SKP15 SKP25 SKP25.0 SKP25.2 SKP55 SKP75 AGA64 AGA65 AGA62.000A000 Permissible media Media inlet pressure «PE» Permissible media temperature Flow rate Permissible test pressure «PG» Permissible under pressure «PG» Gas family Approx. 1.1 kg Approx. 1.6 kg Approx. 1.6 kg Approx. 2.1 kg Approx. 1. kg Approx. 2.3 kg Approx. 30 g Approx. 36 g Approx. 66 g Depending on used valve Depending on used valve Depending on used valve Depending on used valve 100 kpa 20 kpa I...III Environmental conditions Storage DIN EN 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -15...+60 C Humidity <5 % r.h. Transport DIN EN 60721-3-2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -15...+60 C Humidity <5 % r.h. Operation DIN EN 60721-3-3 Climatic conditions Class 3K3 Mechanical conditions Class 3M3 SKP25.0 with AGA30.7 and SAS See Use No classification «-M-» (restricted operating conditions) Temperature range -10...+60 C (longer opening times below 0 C) -20 +60 C (with heating element AGA63.5A27) Temperature range -5 +55 C Mechanical conditions SKP25.2-10...+50 C (restricted operating conditions) SKP25.0 with AGA30.7 and SAS -4 +54 C (restricted operating conditions) Humidity <5 % r.f. Installation altitude Max. 2,000 m above sea level 34/44

Contact assignment device connector Connection of actuator (front-view) N L 1 2 3 7643z43/0706 2 1 3 If valve closed Valve actuator Connection via AGA64 DIN EN 175301-803-A End switch Connection via AGA65 DIN EN 175301-803-A (Only with SKPxx.xx1xx) 35/44

Dimensions Dimensions in mm Actuators SKP15 Example: SKP15.000 7643m18e/0407 188 Hexagon socket width across flats 4 mm 83 M5 15.8 18.3 74 87 64 74 86 SKP15.000 (no valve stroke indication) SKP15.001 30.5 30.5 Connector valve-actuator to DIN EN 175301-803 design A, 2 pole + 6.3 Detail X Connector valve-actuator to DIN EN 175301-803 design A, 2 pole + 6.3 Detail X Connector end switch to DIN EN 175301-803 design A, 3 pole + Tightening torque central screw 0.4 Nm M3 18 Tightening torque central screw 0.4 Nm M3 18 7643m16e/0407 7643m17e/0407 36/44

Dimensions (cont d) Actuator SKP25.0 / SKP25.3 / SKP25.6 Dimensions in mm 6.2 32.5 Rp1/4 Rp1/4 Pressure test point 188 202 221 X 168 200 Hexagon socket width across flats 6 mm 83 M5 86 7643m1e/0407 15.8 18.3 64 74 106 74 87 8 141 SKP25.001 Connector valve-actuator to DIN EN 175301-803 30.5 6.3 design A, 2 pole + Only SKP25.001... / SKL25.001... connector end switch to Detail X DIN EN 175301-803 design A, 3 pole + 4.8 Tightening torque central screw 0.4 Nm M3 18 7643m20e/0407 37/44

Dimensions (continued) Dimensions in mm Actuator SKP25.0 with AGA30.7 and SAS) 7643m37/1215 ~5...107 ~138 48...58 6 ~282...22 38/44

Dimensions (continued) Dimensions in mm SAS motorized setpoint adjuster B C1 C2 7643m38/1215 E A D Without ASK3.2 Type A B C C1 C2 D E Kg 137.6 1) 151 2) 80 106.5 21. 84.6 2. 21.8 100 200 0.68 3/44

Dimensions (cont d) Dimensions in mm Actuator SKP25.2 71.5 32.5 Rp1/4 Damping throttle AGA25.2 Rp1/4 45.7 Pressure test point 188 202 221 X 168 207 Hexagon socket width across flats 4 mm 83 157.8 (with locking cap) M5 64 86 7643m21e/0407 15.8 18.3 200.8 (with locking cap) 26.5...30.7 4.7...118.3 74 106 74 87 151,5 (without locking cap) 14,5 (without locking cap) SKP25.201 30.5 6.3 Connector to DIN EN 175301-803 design A, 2 pole + Connector to DIN EN 175301-803 design A, 3 pole + 4.8 7643m22e/0407 M3 18 Detail X 40/44

Dimensions (cont d) Dimensions in mm Actuators SKP25.4 71.7 32.5 Rp1/4 168 207 221 Rp1/4 Pressure test point 83 188 202 Hexagon socket width across flats 4 mm M5 86 7643m23e/0407 15.8 18.3 74 106 74 87 64 105.1 148 SKP25.401 Connector valve-actuator to DIN EN 175301-803 design A, 2 pole + 30.5 Detail X Only SKP25.401... connector end switch to DIN EN 175301-803 design A, 3 pole + 4.8 7643m24e/0407 M3 18 Tightening torque central screw 0.4 Nm 41/44

Dimensions (cont d) Dimensions in mm Actuators SKP55 2.7 58.2 32.5 50 Rp1/4 Rp1/4 +Air ATMOSPHERE Pressure test point 188 202 X 168 207 233 Hexagon socket width across flats 4 mm 83 M5 64 86 7643m27e/0407 15. 18.3 Rp1/4 106 74 87 126 16 74 SKP55.001 Connector valve-actuator to DIN EN 175301-803 design A, 2 pole + 30.5 6.3 Detail X Only SKP55.001... connector end switch to DIN EN 175301-803 design A, 3 pole + 4.8 7643m28e/0407 M3 18 Tightening torque central screw 0.4 Nm 42/44

Dimensions (cont d) Dimensions in mm Actuators SKP75 Rp1/4 58.4 32.5 Rp1/4 Rp1/4 Pressure test point 188 202 242 X 188 26 Hexagon socket width across flats 4 mm 83 64 M5 86 7643m2e/0407 15.8 18.3 146 74 87 74 126 16 SKP75.001 Connector valve-actuator to DIN EN 175301-803 design A, 2 pole + 30.5 6.3 Detail X Only SKP75.001... connector end switch to DIN EN 175301-803 design A, 3 pole + 4.8 7643m30e/0407 M3 18 Tightening torque central screw 0.4 Nm 43/44

Dimensions (cont d) Dimensions in mm Adapter plug AGA62.000A000 - For 2 actuators mounted on one double valve N L2 PE PE 1 2 2 1 L1 N 32 25 7643m01e/0407 270 10 M3 L1 Tightening torque central screw 0.4 Nm Connection diagram L1 L2 N PE L2 PE L1 N PE L2 N PE N AGA30.x Ø26 SW4 SW32 7643m36en/0415 SW = Width across flats 52 5,1 38 44/44 2017 Siemens AG, Berliner Ring 23, D-76437 Rastatt Subject to change!