Fisher Optimized Antisurge Control Valves High reliability to meet world-class production demands

Similar documents
Fisher 2625 and 2625NS Volume Boosters

Safety manual for Fisher GX Control Valve and Actuator

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Fisher L2sj Low Emission Liquid Level Controller

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Fisher and Whisper Disk Diffusers

Fisher DVI Desuperheater Venturi Inline

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type EZH Relief or Backpressure Regulator

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

ACTUATORS AND INSTRUMENTS

A Complete Solution For HIPPS

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Emerson Deepwater Offshore Solutions Proven Fisher technology to mitigate risks and meet production targets

Fisher 4660 High-Low Pressure Pilot

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Fisher DSA Steam-Atomized Desuperheater

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Design DSA Steam-Atomized Desuperheater

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Fuel Gas Pressure Control Solutions for Fired Heaters and Boilers

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Becker * T-Ball * Anti-Surge Valve

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

4194 Series Differential Pressure Indicating Controllers

MARKET OUTLOOK. Power Chemicals Petroleum Water/Wastewater Oil & Gas Pulp & Paper and more

1805 Series Relief Valves

Type 4660 High-Low Pressure Pilot

Reliable Control Valve Solutions Achieve greater success by partnering with Emerson

Model 4000 Pressure Controller

Solving Instability Issues in Commercial and Industrial Natural Gas System Applications

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Fisher 4194 Differential Pressure Indicating Controllers

Type 92S Pilot-Operated Steam Regulator

PRO-50 Instrument Supply Regulator

PREDICTING HEALTH OF FINAL CONTROL ELEMENT OF SAFETY INSTRUMENTED SYSTEM BY DIGITAL VALVE CONTROLLER

DeZURIK. KSV Knife Gate Valve. Safety Manual

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

Fisher 8532 High-Performance Butterfly Valve

PRC CO ² -LASER PRESENTATION

Fisher 4660 High-Low Pressure Pilot

Control Valve Training Course Program

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

Type R622 Pressure Reducing Regulator

Emerson Solutions for Ammonia Production Gain efficiency and enhance your operations

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

RESIDENTIAL REGULATORS

Types ACE95 and ACE95Sr Tank Blanketing Valves

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Pressure is our Business

Types ACE95 and ACE95Sr Tank Blanketing Valves

The Criticality of Cooling

Life Sciences. Pressure control solutions for your industry.

VBL Volume Booster. Features. D103393X012 January 2013

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Micro Motion 3098 Gas Specific Gravity Meter

Trifecta High-Pressure Systems

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Model Series 62 Constant Differential Relay

Types ACE95 and ACE95Sr Tank Blanketing Valves

KMT Waterjet Systems Inc.

I Connected Industrial. HON 5020 GAS PRESSURE REGULATOR Enabling Dependable Gas Operations

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

670 Series Panel-Mounted Loading Regulators

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

Type ACE95jr Tank Blanketing Valve

FILTER BYPASS CONTROL

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

AMT-Ex Dewpoint Transmitter

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

REAL. Simple, Intuitive, Powerful Real.

I Connected Industrial. HON 5020 Gas Pressure. Enabling Dependable Gas Operations

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

STICTION: THE HIDDEN MENACE

T208VR Series Tank Blanketing Vacuum Regulator

Improving distillation tower operation

HON C210 Series Control Valves. High Pressure Control valves

Fisher 4194H Differential Pressure Indicating Controllers

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Type 299 Pressure Reducing Regulators

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

S300 Series. Valve Link. Features. Fisher Controls

STANDARD HIGH PRESSURE COMPRESSORS COMPACT PACKAGE FOR DEMANDING APPLICATIONS

Type Cronos Pressure Reducing Regulator

Pressure measurement is a family affair

Non-intrusive Natural Gas Flow Measurement

Selecting the right pressure sensor for your application

FLOW CONTROL BALL VALVES

1805 Series Relief Valves

Transcription:

Fisher Optimized Antisurge Control Valves High reliability to meet world-class production demands

2 Fisher Optimized Antisurge Valves Fisher Optimized Antisurge Control Valves The right choice for high reliability, fine control, fast stroking, and easy tuning of your most critical application. Finally a robust, high-performance antisurge valve that can be easily implemented and serviced in the field. A valve engineered from the ground up to meet the specific needs of compressor antisurge applications requiring the ultimate in control valve reliability. Gone are the days of complicated actuation systems requiring factoryauthorized personnel to tune and commission. The Fisher optimized antisurge valve from Emerson makes short work of valve tuning, saving you money during commissioning. It also pays back your original investment many times over during the life of the equipment with superior dynamic performance. We understand how to integrate antisurge control valve components the valve, actuator, FIELDVUE digital valve controller, and associated instruments into an effective design, thanks to more than 130 years of process control experience. That s why you ll find the Fisher optimized antisurge valve to be best-in-class for reliability, control, and commissioning. Typical 3-Stage Antisurge System Schematic 1 2 3 Antisurge System High performance antisurge valve actuation will help you get the most from sophisticated antisurge controllers. ANTISURGE CONTROLLER

Fisher Optimized Antisurge Valves 3 Site Testing >> Certified Emerson technicians worldwide can perform site testing of your antisurge valve according to the FGS 4L12 test. Rigorous Factory Testing Your compressor antisurge application is no place for uncertainty. With the Fisher optimized antisurge valve and the Fisher FGS 4L11 test you have proof of performance. The FGS 4L11 test validates the valve s static performance, dynamic performance, and servo robustness. Find out more from your Emerson sales contact.

4 Fisher Optimized Antisurge Valves High Reliability Components within the Fisher optimized antisurge valve were selected with high reliability in mind. The FIELDVUE digital valve controller features a rugged I/P converter, a robust pneumatic relay, and potted electronics to protect it from harsh plant environments. Dual certified as intrinsically safe and explosion proof, the FIELDVUE digital valve controller also satisfies the requirements of the European ATEX directive. Its enclosure meets NEMA 4X and IEC 60529 IP66 criteria. You can feel confident that FIELDVUE hardware and software are proven. The FIELDVUE digital valve controller is used in critical applications in which reliability is paramount, such as safety instrumented systems. Cushioned Actuator Mechanical air cushions within the high-speed actuator cylinder provide controlled deceleration to help protect actuator and valve components. A check valve provides full speed performance when the valve is moving away from the travel stop. No Sliding Parts to Wear Non-contact feedback technology in the FIELDVUE digital valve controller eliminates the potentiometer and has no sliding parts to wear. A magnet array and Hall Effect sensor are used to detect valve position. The heavy-duty mounting is designed for the harshest environments. Robust Instrument Mounting Designed to withstand vibration associated with compressor piping systems, the FIELDVUE digital valve controller mounting bracket features an integral antirotator and heavy duty gussets. All mounting parts are stainless steel, easily accessible, and facilitate remote mounting of the instrument.

Fisher Optimized Antisurge Valves 5 A Case-In-Point Arabian Petrochemical Company s (Petrokemya, a SABIC affiliate) ethylene plant experienced capacity issues with its main compressor antisurge valves the most critical valves in the facility. The existing valves were undersized for the valve outlet velocity and took a long time to respond. Turbulence, caused by the difference in gas velocity between the valve outlet and larger downstream piping, contributed to unacceptable noise levels. Ready For Any Climate Elastomers within Fisher instruments are designed to withstand temperatures as low as -40 C (-40 F) or as high as 93 C (200 F) while providing excellent resistance to common impurities within plant air. Emerson engineers rely on decades of non-metallic test experience to accurately select elastomers for long-term reliability. Emerson s solution for the plant consisted of five fabricated valve types, each incorporating proven WhisperFlo noise attenuation trim. Elevated pressure drops and high flow rates inherent to antisurge applications warrant advanced noise-control valve trims. WhisperFlo trim protects the compressor and piping system from damaging vibration while providing superior noise reduction. The trim was characterized to match capacity with the complex compressor performance curve. The fabricated valve bodies provided flexibility in meeting the existing face-to-face dimensions. The valves were equipped with a fast-stroke, antisurge accessory package, which reduced the overall cost of accessories while improving long-term performance. FIELDVUE digital valve controllers provide performance diagnostics and monitoring capabilities for these critical valves. Reduced Noise and Vibration WhisperFlo is a multipath, multistage valve trim capable of reducing noise levels by as much as 40 dba. Flow patterns formed by laser cut discs help ensure repeatable noise attenuation and reduced pipe vibration. Partial Stroke Testing and On-Seat Diagnostics The FIELDVUE digital valve controller automatically checks the condition of the valve during each partial stroke test. Diagnostics such as valve packing friction, air path leakage, valve sticking, actuator spring rate, and bench set can be collected, viewed, and analyzed using ValveLink software while the valve remains in service, without impacting the process.

6 Fisher Optimized Antisurge Valves Peak Efficiency Lowers Operating Costs By moving the compressor s operating point closer to the surge limit line, you can operate more efficiently. This can mean significant reductions in operating costs as much as $250,000 USD annually for a relatively small 4,500-horsepower compressor. Larger compressors that are common to liquefied natural gas facilities could see much larger savings. The faster and more accurately an antisurge valve moves, the more the savings. The Fisher optimized antisurge valve is designed to deliver highperformance actuation and improved control. Exclusively On Fisher Valves The FIELDVUE digital valve offers an antisurge-specific tuning capability that is available exclusively on Fisher valves as part of the Fisher Optimized Digital Valve. The Fisher optimized antisurge valve achieves higher gains, responds better, and has remarkable stability thanks in part to minor loop feedback and other proprietary techniques. Easily customized for critical application requirements, these techniques marry seamlessly with volume boosters to handle nearly any actuator requirements. Fast Stroke and Controlled Deceleration In one second, this Fisher optimized antisurge valve reaches the capacity required to protect the compressor. It safely decelerates thanks to a cushioned actuator.

Fisher Optimized Antisurge Valves 7 A liquefied natural gas facility needed to replace all of its existing propane and mixed refrigerant compressor antisurge valves. After seeing a demonstration of the Fisher optimized antisurge valve, the plant turned to Emerson who has proven its ability to understand and meet stringent valve performance criteria. The 25 existing valves were replaced by NPS 12 through NPS 30 Fisher optimized antisurge valves. Fully Balanced Trim The huge balance area of the unique Fisher spoked plug helps the control valve resist pressure pulsations. A Case-In-Point The valves open in less than two seconds, as well as meet stringent closed-loop control criteria. The measured linearity is less than 0.75%, and the valves have minimal overshoot in the open and closed directions. It often requires about 12 hours to tune a non-fisher antisurge valve. With its fewer accessories and diagnostic capabilities, tuning time for a Fisher optimized antisurge valve takes only minutes. All this adds up to a more reliable antisurge valve solution for protecting compressors and increasing process efficiency. High Resolution This Fisher optimized antisurge valve responds to bidirectional step sizes of 0.25% thru 10% accurately and quickly. (Sample results from Fisher factory assurance testing on production equipment.) Negligible Overshoot Overshoot is negligible for small and large steps. (Sample results from Fisher factory assurance testing on production equipment.)

8 Fisher Optimized Antisurge Valves Reduce Commissioning Time and Lower Costs Factory expertise is not required to tune the Fisher optimized antisurge valve. A technician may simply use ValveLink software s performance tuner or the Stabilize/Optimize feature with real-time graphics (shown far right). Configuration and tuning can also be performed remotely by operators as process requirements change. Avoid the high cost of running separate power and signal wiring by using the Fisher optimized antisurge valve. Its FIELDVUE digital valve controller uses twowire 4 to 20 ma loop power. Advanced, Local Tuning Tune your Fisher optimized antisurge valve using ValveLink Mobile software. You can monitor the valve response and quickly adjust gains to optimize performance. (Large step test study shown in ValveLink Mobile software.) Simple Setup The setup wizard within ValveLink software guides the technician through three simple dialog screens for the Fisher optimized antisurge valve. (Setup wizard shown in ValveLink software.)

Fisher Optimized Antisurge Valves 9 2625 Volume Booster The Fisher 2625 volume booster integrates seamlessly with the FIELDVUE digital valve controller and ValveLink software for robust, high performance tuning. Lead-Lag Remote Tuning with Simple Setup Wizard The lead-lag filter in the FIELDVUE digital valve controller can be used to improve the response to small amplitude steps by overdriving the set point. Asymmetric adjustments allow the response to be set independently in the opening and closing directions. Integrated, real-time graphics allow adjustments to be done remotely. Stabilize/Optimize Feature It is easy for anyone to get full control of the Fisher optimized antisurge valve without disturbing operations using the Stabilize/Optimize feature.

10 Fisher Optimized Antisurge Valves SS-263 Volume Booster Today s process plants require larger control valves than ever before. This increase in valve size has stretched traditional volume boosters to their limit. The SS-263 volume booster brings the field-proven performance of the 2625 volume booster to a whole new breed of large-scale control valves. The rock-solid reputation of the 2625 volume booster was designed specifically for use on control valves with the feature set and dynamic response required to integrate seamlessly with the FIELDVUE digital valve controller. The SS-263 volume booster carries on this tradition on a grand scale. With three times the capacity of the 2625 volume booster, accessory mountings can be greatly simplified and the angle body style results in a cleaner, more compact package. The rugged design features of the 2625 volume booster have been preserved while material selection has been improved. The post-guided poppet valve design eliminates problematic spool valves and continues to work even in the presence of instrument air contaminants such as sand, rust, oil, and desiccants. Modular trim components improve field maintenance and optional high vibration mountings ready the SS-263 volume booster for the most severe applications. Easy to Repair Modular construction of the trim allows for easy field maintenance of all wear components. High Vibration Applications Booster body designed with integrated high-vibration mounting options to handle the most severe applications. Desirable Failure Mode Control valve continues to work in the event of a booster diaphragm or spring failure. Enhanced Throttling Control High-performance trim package allows the SS-263 to seamlessly integrate with the FIELDVUE digital valve controller to maintain precise throttling performance.

Fisher Optimized Antisurge Valves 11 Noise Attenuation Three-stage exhaust trim greatly reduces noise levels. High Capacity Delivers three times as much air as a 2625 volume booster to simplify accessory mounting on large actuators. Bubble Tight Shutoff Soft seat construction ensures the control valve maintains its desired fail position upon loss of plant air. Simplified Tubing Manifold-style body provides additional air connections to simplify and ruggedize the instrument tubing for high vibration service. High Cycle Life Low-stress springs and rolling, convoluted diaphragms provide the durability to attain 1 million-plus cycles.

Whatever Your Needs, Wherever You Are Worldwide service is of real value to every purchaser of a Fisher optimized antisurge valve. Emerson has qualified, factory trained personnel in all parts of the world ready to help with startup as well as service and repair. Contact your Emerson local business partner or sales office location for more information or to make a purchase. Their highly skilled and experienced applications personnel are ready to help you take advantage of the many benefits of the Fisher optimized antisurge valve. For more severe service solutions, see us at www.fishersevereservice.com Live Demonstration We can demonstrate the Fisher optimized antisurge valve at a location near you. This means that you can view the valve working in real-time, talk to experts, and even try it out for yourself. On-site demonstrations are also available at Emerson facilities in Marshalltown, Iowa; Houston, Texas; Cernay, France; and Jubail, Saudia Arabia. Arrange a demonstration with your Emerson local business partner or sales office today! 2004, 2012 Fisher Controls International LLC. All rights reserved. Fisher, FIELDVUE, WhisperFlo, ValveLink, and PlantWeb are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.emersonprocess.com/fisher The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. D351146X012 / MY61 (H:) / Apr12