WARNINGS. China Advertising Balloons Co., LTD. Helium Recovery Machine( Model AD-CN DS) Contents

Similar documents
Code AWC20HP Air Compressor

3/8" Dr. Air Butterfly Impact Wrench

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operation Instruction Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

CNG FILLING STATIONS

SC6H OIL-LESS AIR COMPRESSOR

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

OWNER S TECHNICAL MANUAL

30T A/Manual Hydraulic Shop Press

Model Air Caddy Orig TABLE OF CONTENTS

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

accidents which arise due to non-observance of these instructions and the safety information herein.

Operation Manual Air Saver Unit ASV5000 Series

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

4 ANGLE GRINDER MODEL NO: CAT 52 PART

Operating Manual. Model BAC-30RT30/BAC-30DC

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

REVERSIBLE AIR DRILL

Safety instructions and operating manual

User Instruction Manual

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

24 Litre Air Compressor

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

Liquid ring compressors

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

High Pressure Breathing Air Compressors NAUTILUS MINI

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Nitrogen Tyre Inflator Owner s Manual

Power Valve: Precision Regulator. High precision, large capacity relief regulator

CLARKES ERO FEEDER MANUAL

200 PSI COMPRESSORS - MODEL NUMBERS

Liquid ring compressor

100C Air Compressor Kit

User Manual for the Mars Calibration Bench

SC100V AIR COMPRESSOR

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

COUNTER CURRENT UNIT. Instruction Manual

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

AC558RB AC7011RB. operation manual

VERTICAL AIR COMPRESSORS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

MANUAL BE SERIES Test Benches

Product Range. High performance and economic high pressure solutions Made in Germany

TrekMill USER'S MANUAL MM5050

MODEL NUMBER: AS18-2 USER GUIDE

LMU100/200 Series. Standard Specifications

Oxygen Concentrator Instruction

High Pressure Breathing Air Compressors

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Liquid ring vacuum pumps single-stage

1/2 DRIVE AIR IMPACT WRENCH STUBBY

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

HEAVY DUTY BELT SANDER. MODEL NO: CAT 70 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 0906

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

IMPACT WRENCH MODEL NO: CAT78 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0813

Operating Instructions Model and Hydrostatic Test Pump

Air Operated Hydraulic Pumping Systems to 50,000 psi

1/4 Air Ratchet Wrench

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Portable Compressed CO 2 Regulator

IWATA G-SERIES MANUAL & PARTS GUIDE

EGL-12 OIL-LESS COMPRESSOR

/ /

3/8 ANGLED AIR DRILL

r (bar) Air Volume(L) Approval Service Life TPED 15

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

3:1 High Ratio Oil Pump W. Extn. Kit

Eaton Filtration, LLC

USER MANUAL. MACMAG magnetic separator MHK MHF

CompAir provide high quality and reliable Nitrogen solutions

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

SC24H & SC50H AIR COMPRESSOR

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

ASSIGNMENT 2 CHE 3473

AIR RATCHET WRENCH MODEL NO: CAT21B & CAT90 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC05/14

MODEL H8253 AIR BELT SANDER INSTRUCTION MANUAL

M-06 Nitrogen Generator (Nitrogen Making Machine)

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

Instruction Manual Recovery Station

Transcription:

Helium Recovery Machine( Model AD-CN-0.42-150DS) It is of vital importance,before attempting to operate your Helium Recover Machine, to read the SAFETY INSTRCTIONS AND WARNINGS section on page 2-4 of the booklet and to strictly adhere to advice contained therein Also, please study the entire contents of this instruction manual, as to familiarize yourself with controls and other features of Machine. Keep these instructions in a safe palace so that you may readily refer to them whenever necessary It is suggested that any instructions supplied with Helium Recover Machine etc are accessible for checking at the same me. Helium Recovery Machine Contents Safety instruction and Warning about your Helium Recovery Machine------------------------------ About the Machine------------------------------------------------------------------------------------------------- Machine parts name----------------------------------------------------------------------------------------------- Detail pictures of other parts ----------------------------------------------------------------------------------- Detail pictures of Machine parts-------------------------------------------------------------------------------- Specification---------------------------------------------------------------------------------------------------------- Operation------------------------------------------------------------------------------------------------------------- Tips and notice------------------------------------------------------------------------------------------------------- Maintain-------------------------------------------------------------------------------------------------------------- Safety instruction and Warning about helium Gas recovery Machine Remember that your Machine is not a toy, but a highly Efficient internal-combustion Machine whose power is Capable of harming you, or others, if it is misused of abused. As ower,you,alone,are responsible for the safe operation Of your Machine, so act withdiscretion and care at all times.if at some future date,your Machine is WARNINGS Never touch, or allow any object to come into contact with m when it is running. Never all any object to come to into contact with fan

acquired by another Person,we would respectfully request that these instructions are also passed on to its new owner. The advice which follows is grouped under two headings According to the degree of damage of danger which might Arise through misuse or neglect. WARNINGS These cover events which might involve serious ( in extreme circumstances, even fatal ) injury. NOTES These cover the many other possibilities, generally less obvious sources of danger, but which, under certain circumstances, may also cause damage or injury. Helium Recovery Machine About Machine It is diesel power Machine ( Model AD-CN-0.42-150DS) Machine Parts name

2 1 3 7 4 8 5 6 9 10 11 12 13

14 15 16 17

18 19 20 21 22

23 23 24 24 24

24 25 1.Diesel engine 2.Air compressor 3.Main panel 4.Third level press instrument 5.Second level press instrument 6.First level pressure instrument 7. Water temperature instrument 8. Switch of gas outlet 9. Switch of gas outlet 10.Gas outlet 11.Gas outlet 12.Water outlet 13.Water inlet 14.Gas inlet, connect with air pipe with screw 15.Second Safety alarm 16.First safety alarm 17.First level Oil-water separator 18.Second level Oil-water separator 19.compressor oil tank 20.Inpector of oil 21.Inspectof of oil 22. Oil pipe 23. Throttle switch for Diesel engine 24.Water tank 25:Diesel oil tank Helium recovery Machine Detail pictures of other parts Item Name Quantity (pc) Image No.1 Machine X1 No.2 Water pipe X2

No.3 Air inlet pipe X1 No.4 Air outlet pipe X2 No.4 Shock absorption X4 Helium recovery Machine Detail pictures of Machine parts Name Functions Image A. First level air pressure 0.6-0.8mpa instrument air pressure

B. Second level air pressure instrument 4.9-5.4mpa air pressure C. Third level air pressure instrument 15.2-16.2mpa air pressure (Tips common The date is 12-14mpa It needs more time to compress for higher mpa. D. Water temperature Instrument Inspect temperature on water cooling system (Tip every 10 minutes need to rechange water ) The max temperate is 48 degree E.Compressor oil Tank Fill compressor oil from enterance. 19# compressor oil (500g -1000g) Tips (during first 50h-100h pls rechange oil which can help you longer life)

F. Inspection Fill oil no higher than (upper potion and not below than low potion) G.Water Pipe Connecting pipe for water inlet and outlet H. Air outlet Connect air pipe to Tank (Tips for 40 liter tank pls every 20 minutes to rechange tank) I. Switch of air outlet Turn left is open and turn right is close Each switch control one outlet

J. First Level oil-water separator In this position is open Tips: (turn up is close and turn down is open) Every 20 minutes should open it to let oil/water out to keep dry of gas. The recovery purity will be same as before. K. Second Level oil-water separator When you recovery one Tank pls turn left to let oil/water go. Tip (Turn left is open and Turn right is close) When recovery one tank pls open it to let oil/water out. Every 20 minutes to operate it let oil-water out L. Safety Alarm If one of them alarm it tells you to shut down Machine to examine. There is trouble or wronge operation on Machine M. Oil pipe Tips(If Machine runs for long time there is no oil bubble in pipe it tells you to check the oil tank in Machine)

N. Helium tank Tips For 40 liter tank every 20 minute is full Pls loose a little valve for few seconds there is some air exist in air pipe when you didn t run Machine. O.Air pipe It is open in this position Air pipe connection (blimp or balloon from air pipe of them) Tips: There are two switches for enterance it means you can recovery two blimp or balloon one time Tips (tipe entrance to balloon) Helium recovery Machine Specification Model AD-CN-0.42/150DS After assemble capability:25.2m3/h for 1 outlet Outlet: 2 piece Total :50.4 M3 /h Package:150X55X90cm Plywood box Gross weight:350kgs Net weight:320 kgs Rated pressure: 14.7Mpa rated pressure: 150 kgf/ cm 2 Power:11KW G18*1.5 for nozzle-standard with tank Diesel Engines: Power:10.5 KW Motor of speed:2000 RPM Engines oil: Diesel oil: Oil Tank: 30 liter Noise: 90DB 3.5 liter NO.0 for summer -10 or -20 for light diesel oil for winter Consumption: 6 liter per hour

Air compressor: Motor of speed:1440rpm G18*1.5 for nozzle-standard with tank Oir of air compressor: SY1216-72,HS-19 (500g to 1000g) Consumption: 75g/hour Air pressure for each valve First level Valve Second level Vavle Third level Vavle 0.6-0.8mpa 4.9-5.4mpa 15.2-16.2mpa Helium recovery Machine Operations Specification Checking before operation 1. Fill diesel oil, engine oil and water to Diesel engine 2. Fill HS-19# 2000g compressor oil to Air Compressor Viscosity is 220, Every 500 hour to change compressor oil, at beginning every 50-100 hour to change 1 time 3. Check the fastening connector of Machine 4. Check the triangle belt of diesel engine with air compressor 5. Check connection of pipes A. pipe of water input and output B. pipe of air input and output 6. Check belt no block 7. Check the belt should rotate in Counterclockwise Steps to operate: 1. Before you operate the Machine please turn on following valves/ Switch (in order to let air out) Oil-water Separators valve Level 1 and level 2 (Part 17) Air outlet Valve(Part 8 and Part 9 in Machine) Turn off air-input valve

2. Connect the water input and output with water tank Big than 50 liter Tank notic the water temperature should less than 40 Celcius (As experience every 20 minutes you need to change water, it is very important otherwise it will damage Cylinder block of air compressor. 3. Connect air inlet pipe to balloon or blimp 4. Turn on and Running the diesel engine running at rated speed 5. Running 3-4 seconds,turn off /closed valves of following A. Oil-water Separators (Level 1 and level 2) the B.Air outlet Time of 3-4 seconds is let helium gas to push air exist on pipe or Machine, in order let 6. Connect helium tank to Machine at this moment no need to tight the valve of tank, because after running Machine, there is some air gas exist in air compressor or in air inlet pipe, so in order to keep helium in same purity, you need to release air gas it is important for helium purity. At Step 5, the air needs to be released. 7. Open the valve of air inlet valve to recover helium now 8. Rate air pressure is 14Mpa, but as experience when it comes 12Mpa you need to change a new tank to recovery helium.it takes much longer time from 12Mpa to 14Mpa 9. Change cylinders while refilling the gas back into the cylinders A) If you do not want the machine to be halted, please following step: 1) Connect only one cylinder to one of air letout pipes, 2) Open its Switch 3) And close other Switch at same time, Running the machine (detail operation refer to Step 6 ). 4)Refill gas to Cylinder. When it reaches Mpa you want to store,close its Switch 5) Connect new empty cylinder to another air outlet pipe, Open its switch to refill

gas to new cylinder. Take full Cylinder out and change third empty cylinder 6) Circle steps like this, (do not halt the machine) B) If you connect two cylinder at same time, you need to halt machines to change new cylinders at same time. Please take notice on Tips 4 Helium recovery Machine Tips and Notice 1. Every 20minute or shorter it to open wate-oil sperator (to separate moisture from helium gas) 2. Reted air pressure is 14Mpa but it takes longer time to reach, normal it is 12Mpa to change new tank for store 3. Water temperature in tank is no more than 44 Celcius, change the new cold water every 10 mintues about, if over it, will damage Cylinder block of air compressor. 4. When you pause or stop running(halt) Machine, take a notice there is high pressure in air compressor, for next running please release the air as Step 6,loose the valve of helium tank with pipe to let air release. if you do not do that, when you re-operate diesel Machine, it seems Machine is running but high pressure to block helium gas in, it will damage clutch of air compressor. 5. When you pause or stop running Machine, take a notice there is high pressure in air compressor, for next running please release the air as Step 6,loose the valve of helium tank with pipe to let air release. 6. When you stop to run Machine should close and open A. the valve of helium tan B. Valve of air compressor C. Open water-oil separator 7. Take care of compress oil, not be lows than lower inspector. 8. counter-clockwise to open the valve,and clockwise to close the valves Helium recovery Machine If exist following any of phenomenon must stop the Machine to check There is a severe shock and knocking Safety valve tripping Cooling water supply interruption Gauge pressure is not normal Rubber safety film two cylinder water jacket rupture Warning oil seal if you has no use the Machine more than 3 months Helium recovery Machine Maintain when first time to run should add lubricating oil 10g to guide air compressor to run

Only China Advertising Balloons Co., LTD-- Have this copyright www.adballoons.com.cn E-mail:sales@adballoons.com.cn or forestairship@hotmail.com SKYPE:forestchina1983 Mobile : 0086 18626302806 Phone:0086-510-82022533 Fax:0086 510 85440000 Address: No.29-2 Luou Road, Hudai Industry Park, Binhu District, Wuxi, Jiangsu Province,China POST CODE:214126