Prep LC Training Manual S.V.

Similar documents
Prep LC Training Manual

SOP: Buck Scientific BLC-20P HPLC Operation

GCMSD-Headspace Analysis SOP

Setting a New Standard in Flash Chromatography Performance

Figure 1: Plug in ion inlet of mass spec

AKTA pure 25 New Owner s Intro

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

5890II GC Standard Operating Procedure 9/2/2005

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

The instrument will process the samples one by one till all the samples have been cleaned up.

DOS in Food Science & Nutrition, Manasagangotri, Mysore

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

System Overview. TCD Detector temperature setpoint Regulator

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Recovery collection complete sample recovery in preparative HPLC

Armfield Distillation Column Operation Guidelines

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Gas Diluter Portable Gas Dilution System User s Manual

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

operator s manual plus system system nanolc Operator s Manual Revision A1

PerkinElmer Aanalyst100

SOP: Anion Exchange Chromatography of Green Fluorescent Protein (GFP) using the AKTA Pure system

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Operation of the Perkin Elmer TGA-GC/MS

SOP for use of the SX19 Stopped-Flow Instrument

Using the Akta Prime plus October 22, 2012

SOP: Cation Exchange Chromatography of t-pa using AKTA Pure system

Agilent 1260 Infinity Purification Solution

Determination of Zn using Atomic Absorption with Multiple Standard Additions

School of Molecular Bioscience SMB019. Kamrul Zaman

Pre-installation Checklist

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

Extended Application Note

SHIMADZU LC-10/20 PUMP

User Manual. Agilent 1260 Infinity Analytical- and Preparative-scale Fraction Collectors

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Calibration of a GC955

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Air Operated Hydraulic Pumping Systems to 50,000 psi

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Quick Start Guide for SA-9600 Series Surface Area Analyzer

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

LC, RSLC, Bio RS and Dual Gradient Systems

SOLUBILITY OF A SOLID IN WATER

HPLC. Solvent Delivery Module Systems

Ideal gas law. Introduction

1. Study the performance of a binary distillation column operated in batch mode.

Manual for continuous distillation

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

The instrument should have a mass range from 2 to 2000 m/z or better Interface

CHM250 Calibration and Measurement Lab. Balance Calibration

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Running HPLC Methods on an ACQUITY UPLC System

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Operating Instructions

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

Video Notes. LC Troubleshooting Series Retention Time Shifts

Ascentis Express HPLC Columns with Fused-Core Technology

FROG-4000 TM Chemical Analysis System

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

6900 Maintenance Instruction System Flush

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

SOP: Lysine Affinity Chromatography of t-pa on the ÄKTApure Chromatography System

More Speed and Resolution for Current Methods

Agilent Dimension Software for ELSD User Manual

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

Aerobic Respiration. Evaluation copy

Determination of Zn using Atomic Absorption with Multiple Standard Additions

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Equipment Operating Procedure Glove Box

Standard Operational Procedure for Capillary Electrophoresis

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Standard Operating Procedure

6800 Maintenance Instruction System Flush Procedure

FROG-4000 TM Chemical Analysis System

SOLUBILITY OF A SOLID IN WATER

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Vapor Pressure of Liquids

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

Transcription:

1234 Hach Hall 515-294-5805 www.cif.iastate.edu Prep LC Training Manual 11-6-2013 S.V. Location: Contact: 1238 Hach Hall Kamel Harrata, 1236 Hach Hall and Steve Veysey, 1234 Hach Hall Safety: All researchers working in 1238 Hach Hall must complete the EH&S courses: Fire Safety and Extinguisher Training, and Lab Safety: Compressed Gas Cylinders. When preparing samples in 1238A, please wear all appropriate personal protective equipment. Aprons, safety glasses, and rubber gloves are available. Properly dispose of waste solvents and glass pipettes in the containers provided in 1238A. All of the data processing computers and many of the data acquisition computers in this lab have direct links from the desktop to MSDS sheets, the EH&S Laboratory Safety Manual and to the CIF Safety Manual. Introduction: The Agilent PrepStar SD-1 preparative HPLC is a student operated instrument. Students (and other researchers) are given an appropriate training in order to affect the prep experiments themselves. The instrument can be operated in analytical, semi-prep, and prep mode. Three C18 column sizes are available: analytical (4.6*50 mm, 1.8 um), semi-prep (9.4*250 mm, 5 um),

and prep (21.2*250 mm, 7 um). Approprite guard columns are also available and must be used in all circumstances. Two Rheodyne manual injectors are mounted next to the pumps. The top one is for analytical and semi-prep with 500 ul sample loop. The bottom one is for the Prep experiments and is equipped with a 10 ml sample loop. Sample collection tubes are provided. Larger size collection tubes or beakers can be used for large collection volumes. The training will include, among other hardware pluming issues, how to remove and install LC columns. Overview: The SD-1 PrepStar is a dual pump (binary) capable of drawing from to separate solvent reservoir A and B. The A reservoir is dedicated to aqueous solutions while the B is always reserved for the organic solutions. The solvent delivery is system a dual interchangeable pump heads that provide pumping capacity to 3.2 L per minute at pressures of up to 375 psi for high throughput microparticulate columns.

Table 1 illustrates general considerations for column size, flow rates, injection volumes, and sample load. Column ID Flow Rate Sample load (mg) Injection volume 4.6 mm (analytical) 9.4 mm (semi-prep) 21.2 mm (prep) 1 ml/min 4.2 ml/min 21.0 ml/min 2-10 mg 10-50 mg 50-200 mg 1-20 ul 100-400 ul 500ul-5 ml Operating Instruction: Before starting an experiment, make sure there is enough solvent in reservoir A and reservoir B. Choose which manual injector to use. Top injector is for analytical and bottom one is for the prep separation. Also, make sure that the purge line and waste line tubing are inserted in their respective bottles. Operating the instrument consists of: Setting up the method Starting and stopping the experiment!!!!pay attention to the Flow rate. It must be 0.000 ml/min when there is no intention of having solvent flow!!!! For existing methods, simply open the desired method from the pull down menu Method. Click the ON button. Verify that the flow rate is the desired one. solvent for several minutes until the back pressure is stable. Direct Control:. Allow the flow of You can control each device directly. Simply right click on the field of the device and set the desired conditions.

Setting up a new method: All methods are located in C:\Chem32\1\METHODS directory. We prefer that each user possesses only one method under ISU username (e.g. C:\Chem32\1\METHODS\usename). Files are always located in C:\Chem32\1\DATA\filname directory. Filenames must be in the form of usernamexxx, where XXX is the incrementing number. Open the prep LC program: From the Method drop down menu click on Edit Entire Method:

Set up flow rate and solvent composition. Click Apply. Set up detector conditions by clicking on the PS-325

Enter wavelengths values. Run time or experiment time is entered in this page. Set up Fraction Collector by clicking on Click OK and save the method:

Alternatively you can collect samples automatically by entering the Action (time slice) or you can collect fraction manually. If you want to manually collect sample simply use the buttons on the main instrument page: The divert valve waste contain 4 buttons. The left one allows collection. The next one to the right stops collection. Data Acquisition:

Test Mix Standard Experiments: Semi-Prep: Eclipse XDB-C18 9.4*250 mm, 5 um Mobile Phase: 70% Acetonitrile/30% Water Flow Rate: 4 ml/min Injection Volume: 50 ul Column back pressure: 1000 PSI Peak# Conc (ug/ml) Compound 1 100 Uracil 2 4000 Phenol 3 500 4-Chloro Nitrobenzene 4 800 Naphthalene