Installation and User Manual

Similar documents
Pressure Regulators. Operating Instructions. Instrumentation

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Bulletin 2537-M2/USA Service Bulletin Series PRM

WW-720. Pressure Reducing Control Valve

Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366

WW-720. Pressure Reducing Control Valve

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

RD(H)20/25 Pressure-Reducing Regulator User Manual

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

LRS(H)4 Pressure-Reducing Regulator User Manual

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Model Air Caddy Orig TABLE OF CONTENTS

Avenger Model 33M Installation & Operation Instructions

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Float Operated Level Controllers

Pneumatic Powered - Plunger Pumps

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

DS05C,D,G Dial Set Pressure Regulating Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

DS06D,G Dial Set Pressure Regulating Valve

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

WW-730. Pressure Sustaining/Relief Control Valve

Aftercooler Owner s Manual

TECHNICAL INFORMATION

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

64 Series Pressure Reducing Regulators

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Operation Manual Air Saver Unit ASV5000 Series

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Model 40H Nullmatic Pressure Regulators

Installation, Operation, and Maintenance Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Powers Controls D Day-Night Thermostats

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Technical Information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Universal Valve Company Inc

Universal Valve Company Inc

RC 195 Receiver-Controller

NTF-230 OPERATION MANUAL

MF2M Monnier Miniature Compressed Air Filter

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

HPB25 Hydraulic Paving Breaker

Advanced Fluid Handling Cart Owner s Manual

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

AIR RATCHET WRENCH MODEL NO: CAT21B & CAT90 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC05/14

Installation of Your SprayMaster System

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Operating Manual. Model BAC-30RT30/BAC-30DC

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

REVERSIBLE AIR DRILL

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

IMPACT WRENCH MODEL NO: CAT78 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0813

Electropneumatic Transducer (I/P) Installation, Operation and

TECHNICAL INFORMATION

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

MEGR-1912 Instruction Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Model Series 62 Constant Differential Relay

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

SUPER PRECISION AIR RELAYS

TWO POST RAM PACKAGE 55 GALLON

ANGLE DIE GRINDER SET

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Techcon Systems TS1254 Pressure Pot

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

200 PSI FAST-FILL AIR SOURCE KIT

FLAPPER NOZZLE SYSTEM

Full Range Pressure Compensating Variable Flow Control

Transcription:

49124589 Revision A August 2015 PacE Flow Controller Installation and User Manual Save These Instructions

Table of contents Table of contents..................................................... 2 INSTALLATION............................................................3 OPERATION...............................................................3 Adjustment of Measuring System.....................................4 Readjustment of Measuring System.................................. 4 TYPICAL INSTALLATION....................................................4 Maintenance............................................................ 5 TROUBLESHOOTING.......................................................5 ORDER INFORMATION AND REPLACEMENT PARTS.......................... 6 49124589 Rev.A

Please read these instructions before installing this product. IMPORTANT INSTALLATION INSTRUCTIONS FOR: PACE 0.5, 1 and 2 1. 2. 3. DO NOT install the unit until you have read this entire product information sheet. Product is specifically designed for clean, dry, compressed air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use with, or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum gas) could be harmful to unit or result in combustible condition or hazardous external leakage. Manufacturer s warranties are void in the event of misapplication and manufacturer assumes no responsibility for any resulting loss. Maximum inlet pressure rating is 300 psig (21 bar) and a control range of 0-160 psi (11 bar). Temperature range is -4 F to 176 F (-20 C to 80 C). INSTALL upstream of and as close as possible to where controlled compressed air is needed. WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the Company, its subsidiaries and authorized distributors provide product and / or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, include without limitation, product features, specifications, designs, availability and pricing are subject to change by the company and its subsidiaries at any time without notice. NOTICE Units can be supplied with air flow direction from left to right or right to left orientations. It is not recommended to reverse flow direction in the field unless absolutely necessary. INSTALLATION 4. 5. 6. 7. 8. 9. OPERATION INSTALL with air flow in direction into Inlet and out System (as noted on chassis housing). DO NOT restrict the air flow with undersize piping or fittings, unless maximum air flow is not needed. INSTALLATION of a 5 micron rated filter upstream of controller is recommended. WITH THE INDICATOR DIAL in the OFF position, allow the inlet side pressure to slowly build and settle to full pressure. DO NOT fill tank on inlet side of system to full pressure and then open ball valve blasting full pressure to inlet of PacE Flow Controller. This may cause system damage. Always throttle valve to slowly increase pressure to controller. TO CONTROL SYSTEM AIR turn adjustment knob clockwise to raise the controlled air pressure and counter clockwise to lower controlled air pressure. To Operate: Once unit has been installed and all safety requirements have been adhered, you are ready to begin. Using the adjustment dial on the front of the PacE, turn knob from the off position slowly in a clock wise motion to the desired setting. Note that as a best practice a 10 psi (7 bar) delta should be set between the Inlet Pressure and System Pressure gauges. The indication numbers on the dial face are for reference only and are not to be used an accurate indication of the system set pressure. If a higher System Pressure is initially set than desired, simply turn the dial counter clock wise until the desired System Pressure is achieved. Note: When dialing the pressure to a lower setting excess air pressure will be exhausted around the front dial. This will continue until the System Pressure is satisfied. The PacE is designed to react quickly to meet flow demands. As a function of meeting this demand, the unit will consume a small amount of air.05 cfm (0.025 dm^3/ s). 49124589 Rev.A

Units are preadjusted at the factory and should require no additional calibration at time of installation. Front Dial Indicator is for reference only and has no bearing on unit functionality or actual Inlet or System Pressure. Gauges (supplied) should be utilized to Adjustment of Measuring System determine actual setting. In the unlikely event that a unit needs readjustment of its measuring system, please follow the following recommendations. Readjustment of Measuring System 1. 2. 3. 4. 5. 6. INSTALL controller on air line with at least 110 psi (7.5 bar) air pressure at the inlet port. REMOVE lock button A (Figure B ) from unit revealing adjustment screw. TURN adjusting knob to 100psi (7 bar) setting. CHECK the gauge for 100 psig (7 bar) reading. If the gauge reads other than 100 psig (7 bar) adjust screw A (Figure B ) with a screwdriver while holding the adjusting knob on 100 psi (7 bar) setting. If more than one half turn of screw A (Figure B ) is required to achieve 100 psig (7 bar). TO CHECK ADJUSTMENT: when dial and gauge are reading the same (100 psi ±2 psi; 7 bar ±0.14 bar), turn adjusting knob to 20 psi (1.4 bar). Unit is adjusted when gauge reads 20 psig ±5 psig (1.4 bar ±0.34 bar). The ±2 psi and ±5 psig are accepted tolerances of the most commonly used gauges. DO NOT adjust screw A (Figure B ) more than one half turn when adjusting unit. If more than one half turn is required to adjust it, additional problems with the unit are involved and unit should be returned to the vendor. 7. B DIAL STOP SET can be used to prevent over pressurization. To utilize the stop set, remove the hold down screw B (Figure B ), lift the hold down washer C (Figure B ). The stop set is located under the dial face. Lift and turn the stop set to desired set point, then replace the dial face, hold down washer and hold down screw. FIGURE B A C FOR ROTARY COMPRESSOR TYPICAL INSTALLATION FOR RECIPROCATING COMPRESSOR 4 49124589 Rev.A

TYPICAL INSTALLATION 90 PSI (6.3 BAR) 85 PSI (5.9 BAR) 115 PSI (8 BAR) 110 PSI (7.6 BAR) 105 PSI (7.3 BAR) 91 PSI +/- (6.3 BAR +/-) 60 PSI (4.2 BAR) Maintenance IMPORTANT MAINTENANCE INSTRUCTIONS FOR PACE FLOW CONTROLLER 1. BEFORE ATTEMPTING TO SERVICE THIS UNIT, READ THIS ENTIRE PRODUCT INFORMATION SHEET AND TURN OFF AIR SUPPLY AND VENT BOTH SIDES OF CONTROLLER. 3. MAINTENANCE SERVICE KITS are available for PacE 0.5, 1 and 2. Service should not be attempted without proper tools, safety and mechanical knowledge. 2. FOR TROUBLE-FREE OPERATION, clean dry air and proper lubrication of the PacE Controller is essential. We recommend a 5 micron pre-filter for maximum performance. Unit is factory lubricated and should not be field lubricated. TROUBLESHOOTING When any of the following symptoms occur, contact technical services for recommendations: A. Excessive relief venting a. Unit is designed to bleed excess air pressure around the control knob, until system pressure has settled. Note: Unit has a constant bleed of approximately.05cfm to maintain ability to react to system demands without delay. b. Secondary compressor in system side, causing over pressurization. See Typical Installation Diagram c. Dial indicator was dialed above system requirements and then dialed down causing venting until system pressure has settled to match dial reading. B. Inability to attain high secondary pressure a. Increase system pressure by slowly turning front dial clockwise until desired pressure is achieved on gauge. Turn dial slow and allow system pressure to adjust and settle before increasing. b. Blockage due to lack of lubrication or dirty air supply. Lack of lubrication is typically caused by excessive moisture in air stream and /or lack of appropriate filtration. 5 micron pre-filter is recommended for maximum product performance. C. System pressure does not match dial indicator a. Adjustment may be required (See Adjustment of Measuring System section of this guide for details) D. Dial does not turn freely or is loose to the touch a. Adjust black thumb screw on front of dial face until desired dial tension is achieved. E. Unit not adjusting during cold weather a. If operating below freezing (32 F/ 0 C) no moisture should be allowed into controller inlet. The above Symptoms are often caused by improper application, dirty and/or wet air supply. Only supply clean dry air to inlet, achieved by a 5 micron pre-filter. 49124589 Rev.A 5

ORDER INFORMATION AND REPLACEMENT PARTS Pace Flow Controller (NPT) CCN Description 49124365 PacE, 1/2 NPT, Left to Right Flow 49124373 PacE, 1 NPT, Left to Right Flow 49124381 PacE, 2 NPT, Left to Right Flow 49124399 PacE, 1/2 NPT, Right to Left Flow 49124407 PacE, 1 NPT, Right to Left Flow 49124415 PacE, 2 NPT, Right to Left Flow Pace Flow Controller (BSP) CCN Description 49124423 PacE, 1/2 BSP, Left to Right Flow 49124431 PacE, 1 BSP, Left to Right Flow 49124449 PacE, 2 BSP, Left to Right Flow 49124456 PacE, 1/2 BSP, Right to Left Flow 49124464 PacE, 1 BSP, Right to Left Flow 49124472 PacE, 2 BSP, Right to Left Flow Replacement Kits and Parts CCN Description 49124480 Kit, O-Ring Replacement, 1/2 PacE 49124498 Kit, O-Ring Replacement, 1 PacE 49124506 Kit, O-Ring Replacement, 2 PacE 49124512 Kit, Replacement Dial Knob 49124522 Gauge, Replacement 49124589 Rev.A

ingersollrandproducts.com 2015 Ingersoll Rand