Peak Pressure Indicator MSI-3

Similar documents
Pressure maintenance valve SDV-P / SDV-P-E

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

ATS430 turbidity sensor Retractable insertion assembly

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Type BBS-03, BBS-05, BBS-06, BBS-25

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instrument Operating Manual

WIKA INSTRUMENT CORPORATION

30T A/Manual Hydraulic Shop Press

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Declaration of Conformity as per Directive 97/23/EC

Type 4708 Supply Pressure Regulator

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Type 4708 Supply Pressure Regulator

BT 800-OX Operating Manual

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Declaration of Conformity as per Directive 97/23/EC

OPTIBAR P 1010 C Technical Datasheet

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Operating manual for Material pressure tanks Vol./1 and Vol./2

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Two-stage valve type NE

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Inverted Bucket Steam Trap IB 16A-7

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

Piloted Non-Return Valves

Type 4708 Supply Pressure Regulator

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Instruction Manual BA90 Precision Barometer

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Dead-weight tester High-pressure version Model CPB3800HP

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Operating Instructions

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Section 3- Repair and Calibration Procedures

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Precision pressure sensor Basic version Model CPT6020

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Installation and Maintenance Instruction Manual

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

ATH-EXx. B Operating Instructions

for the of and the EM55-1

Instruction Manual Contact Pressure Vacuum Gauge

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Installation and Maintenance Instruction Manual

HPB25 Hydraulic Paving Breaker

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

6301 TYPE CAST IRON SAFETY VALVES

Durometer. SHT Series. Instruction Manual SHTD. Valid as of: Please keep the manual for future reference!

2-finger parallel gripper KTG 50

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

You have decided to buy an LP 10 E by STEYR SPORTWAFFEN the new dimension of match air pistols!

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Hydraulic hand test pump Models CPP700-H and CPP1000-H

PNEUMATIC SEALER MODEL A

V43 Pressure Actuated Water Regulating Valve

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Proportional pressure regulators VPPE

CalCheck. Instrument User Manual V1.8

PNEUMATIC SEALER MODEL A

Digital pressure gauge Model CPG500

User manual. ZX trolley.

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Instruction Manual. Pipe Friction Training Panel

Installation, operating and maintenance Instructions for Seemag bypass level indicator

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Transcription:

Peak Pressure Indicator MSI-3 Operating Instructions Cylinder Pressure Monitoring Digital Pressure Indicator DPI No installation Ready to use High quality sensor Large memory Easy handling Cost effective.com +49-4131-959-0 sales.maritime@leutert.com Engine Indicator The MSI-3 peak pressure engine indicator is designed for displaying the maximum value of gas pressures which are subject to rapid variations. The device is particularly suitable to measure the peak pressure in Diesel engines.

EC-Declaration of Conformity The Manufacturer Friedrich Leutert GmbH & Co. KG Schillerstrasse 14, 21365 Adendorf, Germany declares that the following product: Product Peak Pressure Indicator MSI-3 Serial No. 160 bar Part-No. 4644.00.00000 250 bar Part-No. 4645.00.00000 Max. working pressure 300 bar Part-No. 102000 Permissible temperature ambient -20 to 60 C meets the regulations of the following directives including their alterations being valid at the time of this declarations: Machinery Directive 2006/42/EG Pressure Equipment Directive 2014/68/EU (PED), Modul A Adendorf, place,date Representative of executive management for declarations of conformity Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 2

Introduction This operating manual provides instructions on how to use this product correctly, effectively and safely for the intended purpose. Please read all instructions, notes on danger and warning attentively. Please follow all safety instructions and precautionary notes in order to avoid damage to people or property during operation. LEUTERT can not be held responsible for damage or injury resulting from improper product use, incorrect operation or lack of maintenance. This operating manual is directed to technically trained personnel. In case of doubt regarding safety or operational aspects, please do not hesitate to contact LEUTERT for assistance. Should you notice a faulty description or depiction or if you would like to suggest points for improvement, we are looking forward to hearing from you. Please keep the operating manual near the product to have it available if needed. Make sure that the manual is protected from dirt and moisture. Explanation of symbols: DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to personal injury. Friedrich Leutert GmbH & Co. KG, Adendorf, 2008 This document including all of its parts is protected by copyright. Any duplication or utilization outside of the copyright law is not permitted without explicit permission from LEUTERT and may be subject to prosecution. This applies in particular to duplications of any kind, translations and incorporation into electronic systems. Original edition, manuals in other languages on request Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 3

1 General Description The Leutert Peak Pressure Engine Indicator MSI-3 measures and displays the maximum gas pressure of each cylinder in large Diesel engines. This pressure is subject to rapid change while the engine is running. The instrument is hallmarked by simple operation and a high degree of instrumental precision in all speed ranges and may be used to measure engines with a maximum combustion temperature of 350 C. Its sturdy design makes it immune to vibration, with extremely low maintenance requirements. The MSI-3 consists of a sturdy grip section and a solid stainless steel bottom part with connecting nut and venting screw. A stainless steel pressure gauge, is mounted on top end of the bottom part. The bottom part also houses a shock absorber and a shutoff system. The shock absorber regulates and stabilizes the buildup of pressure for the display unit. The shutoff system closes as soon as the peak pressure is reached and, thus, enables a correct pressure reading. The connecting nut enables the MSI-3 unit to be mounted on any indicator valve or cock with a standard W27 x 1/10 thread. The venting screw may be actuated to reset the device to its zero position after the measuring procedure has been completed. Every single device is being tested and calibrated according to our ISO 9001 quality standards and will be supplied with a calibration certificate proving the accuracy of the device. Technical Specifications Measuring ranges 0 to 160 bar, 0 to 250 bar, 0 to 300 bar Engine range up to 2,500 rpm Permissible temperature ambient -20 to 60 C Error margin ± 1.6 % Dimensions 210 mm x 155 mm x 60 mm Weight 1.8 kg without wooden box, 3.0 kg with wooden box Standard connection W 27 x 1/10 Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 4

2 Assembly Drawing and Inventory Item Description Part-No. Peak Pressure Indicator MSI-3 MSI-3 160 bar 4644.00.00000 MSI-3 250 bar 4645.00.00000 MSI-3 300 bar 102000 15 16 17, 18 Item Description Part-No. Tools and Accessories 15 Wooden box 4645.11.00013 16 Hollow spanner 4651.98.00002 17 Test protocol 4645.11.00014 18 Operating instructions 4645.11.00017 Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 5

Item Description Part-No. Components 1 Upper part 4645.11.00001 2 Bottom part, complete 4645.11.00018 3 Valve base plate 4645.11.00003 4 Valve guide 4645.11.00004 5 Indicator valve (stem + spindle) 4645.11.00005 6 Pressure spring 4645.11.00006 7 Copper seal 9000.00.8912300 8 Venting screw 4645.11.00008 9 Pressure gauge 0 160 bar 9000.00.9130700 Pressure gauge 0 250 bar 9000.00.9130800 Pressure gauge 0 300 bar 102004 10 Profile washer for pressure gauge 9000.00.8912200 11 Bracket 4645.11.00009 12 Grip 4645.11.00011 13 Hexagonal screw ISCHRBM05.05500 14 Countersunk screw SSCHRBM06.11000 14 12 11 9 10 1 6 5 4 3 13 8 7 2 Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 6

3 Operating Procedure Check the maximum pressure of the indicator. Put on gloves as the instrument will get very hot during operation. The use of safety glasses is required when operating the indicator as hot gas and particles may be ejected from the engine. Blow out the indicator valve before mounting the indicator to remove possible condensed water, oil or soot deposits which could result in wrong indication of engine pressure. DANGER The valve ejects hot gas under high pressure. Danger of sparks and burns! Close the indicator valve. Mount the indicator onto the indicator valve. Exclusively use hollow spanner provided to attach or remove indicator from indicator valve. Hammering on the extensions of the connecting nut will damage the nut. As a result the nut might brake apart and detach itself and owing to the presence of high pressure severe injury or death may result. The indicator should be mounted close to the engine cylinder to be tested. If necessary the indicator connections may be placed at the side of the engine cylinder leaving the indicator in a horizontal position. This will not effect the correct function of the indicator. In some cases extension tubes are required to attach the indicator. Close the venting screw on the indicator. CAUTION Whenever the indicator valve is open, the venting screw must remain in closed position and must not be opened. Open the indicator valve fully. After a measuring period of approximately 5 seconds, peak pressure readings may be taken. Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 7

Please note, that the MSI-3 is designed to measure engines with a maximum combustion temperature of 350 C. The instrument itself must not get hotter than 60 C. Do not exceed the maximum working temperature of 60 C. Detach the indicator immediately from the indicator valve to prevent any unnecessary buildup of heat in the instrument. After approximately 20 measurements allow the indicator to cool down for 10 to 15 minutes. Close the indicator valve. Note the readings. Open the venting screw to reset the device to zero. Now the next cylinder may be measured. NOTICE Store the indicator when not in use with the venting screw open in order to allow condensation to escape, which may take a couple of hours. 4 Maintenance The MSI-3 was designed to be used without virtually any need for intensive maintenance. The pressurized parts are manufactured from corrosion-resistant material and require no further care. When using the MSI-3, take care that no particles of soot enter the instrument. After every period of use, the tapered connection on the bottom part should be cleaned. If the upper part is disconnected from the bottom part, the copper seals need to be replaced. The same applies if the pressure gauge has been disconnected. It must be ensured that even after prolonged periods of use correct measurement data can be obtained. The instrument should therefore be returned to the LEUTERT factory or authorized service center for testing and re-calibration every two years. Subject to change without notice. Issued 01/2018 MADE IN GERMANY Friedrich Leutert GmbH & Co. KG MSI-3 Operating Instructions, Page 8