Thrust Compensator. Redefining Flow Control. Actuation Solutions for Nuclear Powerplants

Similar documents
Series 2G Diaphragm Actuators

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

ANTI SHOCK RELIEF VALVE

1800C and 1800C-HC Service Regulators

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

6-way characterised control valves DN15 / DN 20 / DN 25

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Declaration of Conformity as per Directive 97/23/EC

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Leak free Pipe Rupture Valve for Excavators

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

How to specify a product. Process Sensors and Mechanical Instruments

Pressure Dump Valve Service Kit for Series 2300 Units

CONTROL VALVE TESTING

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

6-way characterised control valves DN15 and DN 20

Installation, operation & maintenance manual - original version

STAD-C. Balancing valves DN 15-50

STAD. Balancing valves DN (MD60, MD61, MD62)

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Model 130M Pneumatic Controller

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Unit 24: Applications of Pneumatics and Hydraulics

Declaration of Conformity as per Directive 97/23/EC

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

CONTROL VALVE SEAT LEAKAGE

Leak-Free Load-Control Valve SAE ½ psi flange

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

GAS FUEL VALVE FORM AGV5 OM 8-03

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Endura AZ40 Sensor assembly High temperature filter assembly kit

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

Pressure Dump Valve Service Kit for Series 3000 Units

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

553 Series.

INSTALLATION & MAINTENANCE INSTRUCTION

E-118 Assembly Guide

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

BUTTERFLY VALVES Series 800

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

1800CPB2 Service Regulators

Instruction Manual Contact Pressure Vacuum Gauge

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Edward Valves Quick-Closing Equiwedge Isolation Valves... Ongoing Qualification. V-Rep 82-2

INSTALLATION, OPERATION & MAINTENANCE MANUAL

MEGR-1627 Instruction Manual

RC 195 Receiver-Controller

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

STAD-C. Balancing valve ENGINEERING ADVANTAGE

INSTRUCTION MANUAL Pressure Relief Device LPT

DI-DRO ADVANCED FORMING SYSTEMS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Hatch cover securing and tightness

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Declaration of Conformity as per Directive 97/23/EC

Parallel grippers HGPM, micro

3 & 4-Way Mixing & Diverting Valves

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Pneumatic Controls, Air Settings, Hydraulic adjustments on; Models 22HF, 16HF & 1600 machines

Fisher 2625 and 2625NS Volume Boosters

CALEFFI. Ball zone valves. series /03 GB

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Gas Pressure Regulator HON 300

Installation, Operation and Maintenance Manual for Back Pressure Regulator

MAINTENANCE PROCEDURE FOR X 650

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

STA. Double regulating valves DN 15-50

Technical Data Sheet T 2025

Engineering Data Sheet

Anchor Load Cells. Among the different types that are used as anchor load cells

Installation, commissioning and servicing instructions

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Experiment Instructions. Circulating Pumps Training Panel

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

BR 27g. Operating, assembly and maintenance instructions for discontinuous sampling valve. 1. Design, operation and dimensions:

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Self-Aligning Cylindrical Roller Bearings. Plummer Block Housing. Series ACB, sealed on both sides. Series SLG01

WIKA INSTRUMENT CORPORATION

776 Cryogenic Safety Valve

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning

Transcription:

Thrust Compensator Actuation Solutions for Nuclear Powerplants Technical summary and performance details for A and NA range actuator thrust bases with compensation Redefining Flow Control

Contents Section Page Introduction 3 Performance 4 Technical Data 5 Compensator Sizing 6-8 This specification covers the performance details for A range and NA (NAX) range actuators fitted with thrust bases with compensation for valve stem expansion due to high temperatures or for applications where inertia due to high output speeds may cause concern. 2

Introduction The thrust compensator assembly replaces the standard actuator thrust base and consists of a set of spring washers to locate the actuator drive bush. When the pre-load of the spring pack is exceeded in the seating of a valve, the drive bush can move and compress the spring pack thus absorbing high thrusts that may be generated. The thrust compensator requires no setup or adjustment, although heavy or light spring packs are available for specific thrust requirements. This design is ideal for those applications where valve rigidity presents difficulties in high speed operation or high temperature service. THRUST COMPENSATOR APPLICATIONS The thrust compensator enables substantially the same seating torque to be applied to a valve, whether or not differential pressure is present and irrespective of operating speed. It is recommended for use if the stem speed exceeds approximately 24 per minute for gate valves, 8 per minute for globe valves (of rating ASA 600 or higher) and when the specified differential pressure is a substantial proportion of the nominal pressure classification. CONSTRUCTION (Figure 1) Actuators with the thrust compensator option have a modified base and output shaft, carrying a preloaded spring washer cartridge. This permits deflection of the threaded drive bushing once the preload is exceeded. Deflection will continue at the spring rate until the maximum useable deflection is reached. If the factory set preload value is below the valve design thrust, and the deflection can continue up to a substantially higher value, the rate of change of thrust will be related almost entirely to the spring rate during the period which matters, i.e. when torque switch operation is required. This makes the thrust delivered proportional to torque setting within the thrust range of the compensator. The thrust is insignificantly affected by valve stiffness, presence or absence of differential pressure, and relative drop-out time of contactors up to 30 ms. At low speeds, the lower rate of thrust change means that there is less difference between the thrust delivered to the valve and the thrust corresponding to the torque switch setting. Similarly, with low differential pressures, the difference between dry run and service conditions is less significant. Fitting the thrust compensator will also allow for stem expansion or contraction and will significantly reduce the force delivered if the actuator is stalled. HIGH SPEED APPLICATIONS The thrust compensator is used in applications where high speed valve and actuators are required to prevent rapid valve thrust build-up in stem and seat. The thrust compensator acts as a spring cushion or shock absorber to protect the valve and actuator from excessive force due to inertia. The thrust compensator provides no mechanical inertia protection once the maximum useable movement is exceeded. VALVES WITH HIGH TEMPERATURE MEDIUMS Valves which endure large thermal transients have the basic problem that the valve stem, disc and/or seat will expand and contract as the valve medium temperature varies. The thrust compensator design allows the actuator drive bush to move and compress the spring pack as the valve expansion occurs, thus limiting the amount of thrust applied to the valve/actuator assembly. The assembly also has the added advantage that as the valve cools, the contraction of the stem, disc and/or seat will be counteracted by the stored energy in the spring pack, thereby keeping the valve tightly shut. Fig. 1 - Thrust Compensator. 6 3 6 1 2 4 5 The illustration shows how the thrust compensator is added to extend the actuator base. Note: the drive bushing (1) is detachable by unscrewing the drive bushing retainer (2) in exactly the same way as the standard actuator, the retainer being held in position by set screws (3). The drive bushing has one position only, with the same relationship to the base flange as the standard Type A position 1 construction, so that no change of valve mounting flange or stem length is required; removal and replacement of drive bushing can be carried out without disturbing thrust compensator preload. This is factory set at Rotork by screwing the compensator housing (4) against thrust collar (5), which in turn is threaded to the actuator output shaft and locked by set screws (6). No special knowledge is therefore required by personnel responsible for mounting and fitting actuators to valves. Redefining Flow Control 3

Performance PERFORMANCE WITH THRUST COMPENSATOR The following graphs show the effect of the thrust compensator, measured by a strain gauged threaded stem in a thrust rig set up to simulate the stiffness of an 8 ASA 1500 wedge gate valve. Figure 2, Curve A shows the effect of stalling the actuator without the thrust compensator. This line shows the rate of change of thrust corresponding to a valve of this stiffness at 50 per minute. Figure 2, Curve B shows the effect of stalling the actuator with the thrust compensator fitted. This shows the same stiffness rate until the preload is reached. Here the rate of change reduces substantially as long as spring deflection continues. When deflection ceases, the original rate of change is resumed. This time, however, so much energy has been absorbed that the ultimate stalling thrust is substantially lower. Figure 3 and 4, values C, D and E show the effects of different contactor delay times on the same torque switch setting. It is apparent that the change in thrust delivered is very small in comparison with the change, which would have occurred by superimposing the same delay time on Curve A, because of the much lower rate of change. Similar tests have been carried out using different rig stiffness rates. In every case the thrust compensator is much more resilient than the valve structure and such differences can be ignored. Rotork actuator torque switches are calibrated by disc brake torque rigs where load is gradually applied. If the thrust compensator is fitted, the torque delivered to the valve (under torque switch operation with contactor delay times up to 30 ms) will not exceed torque switch calibration by more than 30%. Thrust (lbfx1000) 140 120 100 80 60 40 20 20 Fig. 2 - effect of compensator during actuator stall Thrust (lbfx1000) Stall Curve 'A' No Compensator Curve 'B' Compensator Fitted Fig. 3 - effect of contactor delay on same torque switch setting Thrust (lbfx1000) 40 30 20 10 0 60 Time (ms) Time (ms) 10ms delay Stall 100 200 300 400 500 600 700 10ms delay 100 200 300 400 500 'E' 'D' C 20ms delay D Contactor Operation E 50 Curve 'A' 'C' 20ms delay 40 Contactor Operation C D E 30 0 100 200 300 400 500 Time (ms) Fig. 4 - effect of contactor delay - curves A & B compound 4

Technical Data TABLE 1 THRUST COMPENSATOR TECHNICAL DATA The following table lists the rated thrust (Tr) and the maximum thrust generated (Tm) with the maximum allowable spring deflection (Xm) for each actuator type. A/NA Size Base Mtg. Maximum Stem mm (inch) Preload/Rated Thrust (Tr) kn (Lbs) Max. Thrust (Tm) kn (Lbs) Max spring deflection/expansion (Xm) mm (inch) 3.11 (700) 13.2 (2,971) 1.8 (0.071) 7-13 F10/FA10 32 (1 1 / 4) 6.67 (1,500) 13.34 (3,000) 20.02 (4,500) 16.2 (3,646) 22.5 (5,064) 26.04 (5,861) 1.8 (0.071) 1.8 (0.071) 1.8 (0.071) 8.89 (2,000) 51.2 (11,524) 3.8 (0.150) 14-16 F14/FA14 51 (2) 17.79 (4,000) 35.58 (8,000) 44.48 (10,000) 60.0 (13,505) 76.8 (17,286) 81.8 (18,412) 3.8 (0.150) 3.8 (0.150) 3.8 (0.150) 53.38 (12,000) 90.8 (20,437) 3.8 (0.150) 30 F16/FA16 64 (2 1 / 2) 22.24 (5,000) 44.48 (10,000) 66.72 (15,000) 73.6 (16,566) 93.1 (20,955) 113.8(25,614) 3.18 (0.125) 3.18 (0.125) 3.18 (0.125) 40 F25/FA25 73 (2 7 / 8) 44.48 (10,000) 80.06 18,000) 111.2 (25,000) 113.0 (25,434) 145.2 (32,682) 173.0 (38,938) 4.75 (0.187) 4.75 (0.187) 4.75 (0.187) 70 F25/FA25 83 (3 1 / 4) 53.38 (12,000) 88.96 (20,000) 155.7 (35,000) 145.1 (32,659) 161.6 (36,373) 293.3 (66,016) 6.0 (0.236) 6.0 (0.236) 6.0 (0.236) 90 F30/FA30 83 (3 1 / 4) 53.38 (12,000) 88.96 (20,000) 155.7 (35,000) 145.1 (32,659) 161.6 (36,373) 293.3 (66,016) 6.0 (0.236) 6.0 (0.236) 6.0 (0.236) 222.4 (50,000) 333.6 (75,000) 5.0 (0.197) Redefining Flow Control 5

Compensator Sizing Thrust Maximum useable thrust (Tm) Preload(Tr) Spring Deflection Preload Maximum useable deflection (Xm) Fig. 4 SIZING THRUST COMPENSATORS FOR HIGH SPEED APPLICATIONS For high speed applications a preload (thrust rating [Tr]) shown in the Table 1 should be chosen that is as near as possible or just below the specified valve seating thrust. The maximum thrust (Tm) is the thrust at which compensator movement stops. Wherever possible the maximum thrust value (Tm) should be less than two times the specified valve seating thrust. If the spring pack chosen is too soft or too stiff then the effectiveness of the compensator will be greatly reduced. SIZING FOR HIGH TEMPERATURE APPLICATIONS For high temperature applications a preload (thrust rating [Tr]) should be chosen that is as near as possible to the specified valve seating thrust, and then the thrust generated due to valve stem expansion can be calculated as detailed in the examples given below to ensure that the maximum permissible thrust for the valve is not exceed. The approximate thrust generated due to valve expansion can be calculated from the following equation:- Te = Tr + (Tm - Tr)* Xe Xm Table 1 lists the rated thrusts (Tr) and the maximum thrust generated (Tm) at the maximum useable valve stem expansion (Xm). 6

Compensator Sizing Thrust Maximum useable thrust (Tm) Thrust due to stem expansion (Te) Preload(Tr) Seating thrust (Ts) Spring Deflection Preload Deflection due to stem expansion (Xe) Maximum useable deflection (Xm) Fig. 5 EXAMPLE OF TEMPERATURE COMPENSATOR SIZING WHERE THE VALVE SEATING THRUST IS LESS THAN THE COMPENSATOR PRELOAD (RATED THRUST) Valve Specification/Requirements Seating thrust (Ts) = 11.5 kn Maximum allowable thrust = 41.4 kn Stem expansion Xe = 0.4 mm 7A Actuator using F10/FA10 assembly. Rated Thrust (Tr) = 13.34 kn Maximum Thrust (Tm) = 22.50 kn Maximum Expansion (Xm) = 1.8 mm Te = 13.34 + (22.5-13.34) * 0.4 Te = 15.38 kn 1.8 This solution is acceptable as the maximum allowable specified thrust of 41.4 kn and the maximum thrust rating (Tm) of 22.5 kn is not exceeded. Redefining Flow Control 7

Compensator Sizing Thrust Maximum useable thrust (Tm) Thrust due to stem expansion (Te) Seating thrust (Ts) Preload(Tr) Spring Deflection Preload Deflection due to seating thrust (Xs) Deflection due to stem expansion (Xe) Maximum useable deflection (Xm) Fig. 6 EXAMPLE OF TEMPERATURE COMPENSATOR SIZING WHERE THE VALVE SEATING THRUST IS GREATER THAN THE COMPENSATOR PRELOAD (RATED THRUST) The approximate thrust generated due to valve expansion can be calculated from the following equations:- Xs = (Ts - Tr)* Xm (Tm - Tr) Te = Tr + (Tm - Tr)* (Xs + Xe) Xm Valve Specification/Requirements. Seating Thrust (Ts) = 19.5 kn Maximum allowable Thrust = 44.1 kn Stem Expansion (Xe) = 0.4 mm 7A Actuator using F10/FA10 assembly. Rated thrust (Tr) = 13.34 kn Maximum thrust (Tm) = 22.50 kn Maximum expansion (Xm) = 1.8 mm Xs = (19.5-13.34) * 1.8 = 1.266 mm (22.5-13.34) Te = 13.34 + (22.5-13.34) * (1.266 + 0.4) = 21.8 kn 1.8 This solution is acceptable as the maximum allowable specified thrust of 41.4 kn and the maximum thrust rating (Tm) of 22.5 kn is not exceeded. 8

Notes Redefining Flow Control 9

Notes 10

Notes Redefining Flow Control 11

Redefining Flow Control www.rotork.com A full listing of our worldwide sales and service network is available on our website. Rotork plc Brassmill Lane, Bath, UK tel +44 (0)1225 733200 fax +44 (0)1225 333467 email mail@rotork.com Scan with your smart phone for more information on the Rotork NA Nuclear product range PUB004-003-00 Issue 01/11 Formerly E255E. As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. The name Rotork is a registered trademark. Rotork recognises all registered trademarks. Published and produced in the UK by Rotork Controls Limited. POWTG1012