Series IR1000/2000/3000

Similar documents
Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

Precision Regulator. Series Model Regulating pressure range Port size Page

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

IR1200-A IR2200-A IR3200-A

90 % [l/min (ANR)] Compared with the current IR1000/2000/3000. twice. [l/min (ANR)] Compared with the current IR1000/ %

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Series IRV1000/2000/3000

In-line Air Filter. 100 kpa to 1.0 MPa. New RoHS. Series ZFC. Operating pressure range

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Series ITVH CAT.EUS60-23A-UK

Industrial Filter. FGD series

14.5 m kg. Main Line Filter. 5 kpa or less. New. AFF Series. 160 mm. 170 mm 20 %

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

IR1000-A IR1010-A IR1020-A

Air operated valve. VGA342R Series

Related Products: Auto Drain Valve. Model/Specifications. Model

Prevents condensation

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Series AMJ. Drain Separator for Vacuum

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Direct Operated Precision Regulator Modular Style. Standard Specifications

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Precision Regulator IR3120

(100: 1) Expanded flow range! Compact, Space saving. 2-Colour Display Digital Flow Switch Applicable fluid. Series PFMB. Air, N2

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 V AC. Remote Type. Change the settings while checking the measured value.

5 Port Air Operated Valve

SAFETY IN FOCUS BASIC GUIDE TO SAFETY PNEUMATIC CIRCUITS FOR ISO YOUR AUTOMATION PARTNER

Lightweight and Compact Type Floating Joint

Digital Flow Switch. New. New. Expanded flow range! Compact, Space saving Compared with the current PF2A, 2-Colour Display. Series PFMB.

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Filter-Regulator-Lubricator

reduces flow setting time and setting errors!

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

VACUUM REGULATORS CONTENTS

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Pilot Check Valve: Metal Body Type

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Moisture Control Tube

Booster Regulator/Air Tank

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Machinery Directive (MD) 2006/42/EC. SMC meeting tomorrow s machine safety standards today

Low torque Metal seal type Rotary joint

Parallel Seal Type Slit Valve

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

PVC Quick Drain Valve

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

F.R.L. Units Precautions 1 Be sure to read this before handling.

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Pressure Sensor PSE53#

Filter-Regulator-Lubricator

5 Port Solenoid Valve

8 to 2000 ml/min PB1013A and PB1313A are available up to 1000 ml/min. 52 mm. Car washing machine Water/ detergents supply. Body wetted parts PB1011A

Vacuum Pad with Ejector. Series ZHP

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

SUPER PRECISION AIR RELAYS

EXH. Specifications. Descriptions. Min. working pressure MPa

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

SUPER PRECISION AIR RELAYS

Process Pump. PAF3000 Series/PAF5000 Series

Compressed Air Cleaning Filter Series

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Regulator/Modular Style AR1000 to 6000

Process Pump PB1000A

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Push-In Fitting Type Silencer

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Low Friction Cylinders

Pressure Sensor PSE54#

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Clean Regulator/Fluororesin Type

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

ALF400 to 900, ALT-5/-9

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Operation Manual Air Saver Unit ASV5000 Series

Model 4000 Pressure Controller

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Process Pump. Series PAF3000/Series PAF5000

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

High Precision Regulators R210 / R220 / R230 Series

Transcription:

CAT.E6-B-UK Precision Regulator Series IR// The addition of the small size Series IR and the large size Series IR provides an increased range of flow rates from approx. l/min. to approx. 6l/min.

Precision Regulator Se ries IR// Bracket and pressure gauge can be mounted from directions Mounting is possible on either the front or the back Expanded regulating pressure range The maximum set pressure has been expanded from the conventional MPa to.8mpa Compact and light weight IR width 5mm weight 4g (previously unavailable small size added) IR width 5mm weight g ( width 4%, weight 6% Compared to SMC IR) IR width 66mm weight 64g ( width %, weight 6% Compared to SMC IR4) air operated models Air operated style added to series IR Manifolding is possible Made to order specifications (except series IR, IR) IR IR OUT OUT OUT OUT OUT Features

Modular body introduced (-X) Can be combined with AF (air filter) and AFM (mist separator). Attachments such as a pressure switch can be mounted as accessories Applicable modular sizes IR: Modular type IR: Modular type IR: Modular 4 type Superior relief flow characteristics Relief flow has been increased by nearly 5 times (compared to SMC IR, IR4) IR Conditions: Back pressure MPa IR Conditions: Back pressure MPa IR IR4.. 6 5 4 Relief flow (l/min (ANR)) 5 4 Relief flow (l/min (ANR)) Series Variations Specifications Maximum set pressure Port size Available Model Basic Air operated IR IR IR IR IR MPa MPa.8MPa Rc(PT) /8 Rc(PT) /4 Rc(PT) /8 Rc(PT) / Not available Made to Order Specifications Symbol 8 T L X X465 IRM Specifications/Content Clean room specifications Copper-free specifications Ozone resistant specifications For high temperature For low temperature Non-grease specifications With digital pressure switch (ISE) Manifold (except series IR, IR) Features

Application Examples Constant fluid pressure Balance and drive Accurate balance pressure setting TANK Since there is a large effective area for supply and exhaust, pressure setting can be done quickly. Limits pressure fluctuation when driving a cylinder, maintaining excellent static and dynamic balance. Accurate pressure setting Sensitivity within %F.S. (full span) Tension controller Contact pressure control Winding roller Drive roller Low friction cylinder Adapts to the cylinder's piston displacement, maintaining a constant pressure. Multistage control of work piece pressing force (Wrapping machine) Leak test circuit Measured object Low friction cylinder Features

Precision Regulator Se ries IR// JIS symbol Basic Air operated Standard Specifications Model Max. supply pressure Min. supply pressure Set pressure range IR IR:.5 to MPa IR:. to MPa IR:. to.8 MPa Set pressure+.5mpa () Basic style IR IR:.5 to MPa IR:. to MPa IR:. to.8 MPa IR Maximum.MPa Set pressure+.mpa IR:. to MPa IR:. to MPa IR:. to.8 MPa Air operated style IR IR Set pressure+.5mpa Set pressure+.mpa. to.8mpa. to.8mpa () Input signal pressure. to.8mpa. to.8mpa Sensitivity Repeatability Linearity () (4) Air consumption (At supply pressure of. MPa) Port size Pressure gauge port Ambient and fluid temperature Weight (kg) How to Order Rc(PT) /8 Rc(PT) /4 Within % of full span Within % of full span Rc(PT) /4, /8, / Rc(PT) /8 ( locations) 5 to 6 C (No freezing) 4 Rc(PT) /4 5 Within % of full span 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less.5 l/min (ANR) or less 4.4 l/min (ANR) or less.5 l/min (ANR) or less Rc(PT) /4, /8, / Note ) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differential pressure of.5mpa for models IR and IR, and.mpa for model IR. Note ) Applicable only to air operated styles IR and IR. The basic style is excepted. Note ) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 4) Air is normally being discharged to the atmosphere. Body size IR IR IR Precision regulator IR Type of setting Basic type (Handle) Air operated type (Series IR/ only) Regulating pressure range For series IR/.5 to MPa. to MPa. to.8 MPa Note) Air operated type is model IR only. For series IR. to MPa. to MPa. to.8 MPa Note) Air operated type is model IR only. Symbol size 4 Thread type Rc N NPT F G Option /8 /4 /8 / IR Port size Application IR IR R Suffix Standard For high temp. enviroments ( 5 to C) T (Max. 8 C with pressure gauge.) L For low temp. enviroments ( to 6 C) Suffix Accessory B G None With bracket With pressure gauge Note) None Pressure gauge, Bracket, Name plate, Mounting on the opposite side Pressure gauge is included, (but not assembled). Made to Order Specifications (Refer to page 8) Symbol X X X465 Note) The standard mounting position of the pressure gauge is on the front, when viewing the regulator with the SUP side to the left and OUT side to the right. Specifications/Content Non-grease specifications Compatible with modular connection brackets(refer to page ) With digital pressure switch (ISEA) Add prefix (-) for the clean room specification. Add prefix (-) for the copper-free and fluorine-free specification. Add prefix (8-) for the ozone-resistant specification. 4 Manifold specification is available for IR and IR. (Except IR and IR)

OUT G EXH OUT G OUT G Series IR// Series IR Series IR Series IR Specification Combinations : Standard specifications : Combination possible Blank: Combination not possible Specifications Set pressure max. MPa Set pressure max. MPa Set pressure max..8mpa Connection Rc(PT) /8 Connection Rc(PT) /4 Connection Rc(PT) /8 Connection Rc(PT) / Bracket Accessories Pressure gauge Pressure gauge reverse mounted Connection NPT/8 Connection NPT/4 Connection NPT/8 Connection NPT/ Connection G(PF) /8 Connection G(PF) /4 Connection G(PF) /8 Connection G(PF) / Standard specifications Optional specifications Symbol 4 B G R N N N N4 F F F F4 IR IR IR Applicable model IR IR IR IR IR IR IR IR Modular Products and Accessory Combinations Description. Air filter. Mist separator. Interface 4. Interface with bracket IR--X AF AFM Y YT Applicable model IR--X AF AFM Y YT IR--X AF4 AFM4 Y4 Y4T Note ) Use the made-to-order product (IR-X) for modular connections. The interface and interface with bracket listed above cannot be connected to the standard type. Use a conventional connection interface when connecting the standard type with modular connections. Note ) The made-to-order product number (IR-X) is for the precision regulator only. For modular connections, please order the applicable products and accessories separately. <Combination example> einterface rinterface with bracket 8 8 97 69 wafm qaf IR--X qaf wafm IR--X 4 qaf4 wafm4 5 Accessory (Option)/Part No. IR--X Description Bracket Pressure gauge IR G-- IR P6 G-4- IR G-- IR G4-- Part no. IR P68 G4-4- IR/ G4-- IR G4-- IR IR/ P6- G4-4- G4-- A bracket and two mounting screws (M5 x 5) To mount the bracket, remove two body screws (M5 x ) on the name plate on the opposite side and replace the attached two bracket mounting screws (M5 x 5). Accuracy ±% (Full span)

Series IR// Construction IR IR IR!6 Fixed orifice!5 SUP side passage!6 SUP side passage!6 SUP side passage OUT side passage OUT side passage Setting spring Setting knob Diaphragm (A) Flapper Nozzle Diaphragm (B) Exhaust!4 Diaphragm (C) SUP() OUT() SUP() OUT() Exhaust valve SUP() OUT() Main valve Valve guide Exhaust Valve guide Valve guide IR IR Operating Principles (for IR) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed orifice and to act on diaphragm B as nozzle back pressure, the main valve is pushed down by the generated force and the supply pressure flows out to the downstream side. The air pressure that flows in acts on diaphragm C and while opposing the force generated by diaphragm B, it also acts on diaphragm A opposing the compression force of the setting spring and becomes the set pressure. If the set pressure rises too high, diaphragm A is pushed up, the interval between the flapper and the nozzle widens, the nozzle back pressure drops, the balance of diaphragms B and C is broken, the main valve closes, the exhaust valve opens and the excess pressure from the downstream side is discharged to the atmosphere. In this way fine pressure variations are detected by the nozzle/flapper style pilot mechanism, and precise pressure adjustment is performed.!6 SUP side passage SUP() OUT side passage IN Exhaust OUT()!5!6 SUP side passage!4 SUP() OUT side passage IN OUT() Replacement Parts No. Description Material Diaphragm assembly Diaphragm assembly Diaphragm 4 Valve 5 Valve 6 Valve 7 Valve 8 Damper 9 O-ring O-ring O-ring O-ring O-ring 4 Seal (A) 5 Seal (B) 6 Fixed throttle NBR, other NBR, other NBR, other Stainless steel, NBR Stainless steel, NBR Brass, NBR Brass, NBR NBR, other H-NBR NBR NBR NBR NBR NBR NBR Stainless steel Repair kit no. (A set of above nos. q to!5.) Valve guide Valve guide IR IR IR IR IR Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. P6- P6- P658 P6 ø.5 x.5 ø x. P68 P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67 P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67 KT-IR KT-IR KT-IR KT-IR KT-IR Note) Use mini-flick type.

OUT OUT OUT OUT Series IR// Dimensions IR- IR- M5 X P 46 5.5 9 4.5 ø8.5 M6 X P 5.5 Exhaust 6 7 4 ø9.5 ø OUT 9.5 SUP() G OUT() ø4 7.7 SUP() OUT() 4 5 -Rc(PT) /8 Port size EXH 5 -Rc(PT) /8 Pressure gauge port 6 5 5 x Rc(PT) /4 Port size Rc(PT) /8 Pressure gauge port ø Panel mounting hole 5 4 8 Mounting hole Bracket ø.5 Panel mounting hole 5 6 SMC Mounting hole Bracket SMC Max. 4 Panel Pressure gauge Panel Max. 4 Pressure gauge IR- IR- M5 depth 7 Exhaust ø4 75 8 8 9 SUP() ø9.5 5.5 IN OUT() M6 X P 9 ø5.5 6 5 x Rc(PT) /4 Port size 5 Rc(PT) /8 Pressure gauge port ø4 68 66 EXH() 76 48 Rc(PT) / Exhaust port SUP() -Rc(PT) /4 to / Port size 66 OUT() -Rc(PT) /8 Pressure gauge port IR- M5 depth 7 5 Mounting hole 6 9 ø5.5 Bracket Pressure gauge 48. 8 6 SMC Mounting hole Bracket Pressure gauge ø4 68 66 EXH() 76 44 SUP() Rc(PT) / Exhaust port -Rc(PT) /4 to / Port size 48. 66 8 6 IN OUT() x Rc(PT) /8 Pressure gauge port Mounting hole Bracket Pressure gauge 4

Series IR// Flow characteristics Testing methods conform to JIS B87. Relief characteristics IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR- Pressure characteristics Conditions: Supply pressure MPa Set pressure MPa Flow rate l/min (ANR). Set pressure P (MPa) 4.98.5..96 5 5 5 4 8 6 4..8.9. Supply pressure P (MPa) IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR-. Set pressure P (MPa) 4.98..96 5 5 5 5 6 8 4..8.9 Supply pressure P (MPa). IR- Conditions: Supply pressure.mpa IR- Conditions: Back pressure.mpa IR-.8..9.8.. Set pressure P (MPa) 4.98.96 4 5..8.9 Supply pressure P (MPa). 5

Series IR// Flow characteristics Testing methods conform to JIS B87. Relief characteristics IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR- Pressure characteristics Conditions: Supply pressure MPa Set pressure MPa Flow rate l/min (ANR) 4..5. Set pressure P (MPa).98.96 4 5 6 7 4..8.9. Supply pressure P (MPa) IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR-. Set pressure P (MPa) 4.98..96 4 5 6 7 8 9 5 4..8.9 Supply pressure P (MPa). IR- Conditions: Supply pressure.mpa IR- Conditions: Back pressure.mpa IR-..8.9.8.. Set pressure P (MPa) 4.98.96 4 6 8 4 IR- Conditions: Supply pressure.mpa IR- Conditions: Back pressure.mpa IR-.8. 8 6 4..9.8. Set pressure P (MPa) 4.98.96..8.9 Supply pressure P (MPa). 4 6 8 4 8 6 4..8.9 Supply pressure P (MPa). 6

Series IR// Flow characteristics Testing methods conform to JIS B87. Relief characteristics IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR- Pressure characteristics Conditions: Supply pressure MPa Set pressure MPa Flow rate l/min (ANR). Set pressure P (MPa) 4.98.5..96.94 4 5 5 5 5..8.9. Supply pressure P (MPa) IR- Conditions: Supply pressure MPa IR- Conditions: Back pressure MPa IR-. Set pressure P (MPa) 4.98.96..94 4 5 6 4..8.9. Supply pressure P (MPa) IR- Conditions: Supply pressure.mpa IR- Conditions: Back pressure.mpa IR-.8..9.8.. Set pressure P (MPa) 4.98.96.94 4 5 6 6 5 4..8.9 Supply pressure P (MPa). IR- Conditions: Supply pressure.mpa IR- Conditions: Back pressure.mpa IR-.8...9.8. Set pressure P (MPa) 4.98.96.94 4 5 6 6 5 4..8.9 Supply pressure P (MPa). 7

OUT OUT OUT OUT OUT Series IR// Made to Order Specifications Contact SMC for detailed dimensions, specifications and delivery times. Order Made 8 Clean Room Standard model number Note) Contact SMC if equipped with pressure gauge. Clean room specifications Specifications Cleanliness port EXH port Grease Copper-free Class With M5 fitting (applicable tube O.D. ø6) IR/: M5 fitting (applicable tube O.D. ø6) IR: Rc(PT) / female thread Fluoropolymer grease External and internal copper parts are changed to stainless steel or aluminum. 4 For High and Low Temperature Environments Standard model number T Specifications Symbol Environment Ambient temperature Rubber material 5 Standard model number Note) Contact SMC if equipped with pressure gauge. Copper-free specifications Ozone Resistant Fluoro rubber is used for rubber seal materials. 8 Standard model number Ozone resistant specifications Non-Grease T L T For high temp. environments For high temperature For low temperature L For low temp. environments 5 to C (Max. 8 C with pressure gauge) to 6 C FKM Special NBR or silicon rubber Assembly is performed in an ordinary environment without using grease. However, since parts are not washed, they are not completely oil-free. Standard model number X For high/low temperature environments Non-grease specifications 6 With Digital Pressure Switch With digital pressure switch (model no: ISEA---ML). Mount a digital pressure switch into the connection port for pressure gauge, as it is not mounted at the time of shipment. Specifications Made to order part no. Pressure switch Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Current consumption How to Order Standard model no. Note) Note) Except for symbol G Note ) Please contact SMC separately for details about the external dimensions, etc. Note ) For details on handling digital pressure switch and specifications, refer to the catalog (CAT.E-7): Series ISEA. Note ) Digital pressure switch is packed togther. 7 X465. to. to 4 VDC %, Ripple (p-p) % or less (With reverse connection protection) 4 ma or less X465 A With digital pressure switch Switch specifications Symbol A B C D to 8 station manifold type regulators. (Please contact SMC regarding 9 or more stations.) Output specifications NPN open collector output PNP open collector output NPN open collector output + Analog voltage output NPN open collector output + Analog current output Manifold Specifications (Except type IR and series IR) IRM G Manifold type regulator Specifications Stations Port Body size Set pressure Accessory (Pressure gauge) IR IR Set pressure and quantity MPa setting to n pcs. MPa setting to n pcs..8 MPa setting to n pcs. Example ) MPa setting with 6 stations IRM-6G-6 Example ) MPa setting pcs., MPa setting pcs.,.8 MPa setting pc. with 5 stations IRM-5G- Stations Accessory (Pressure gauge) stations Nil None IR: G-- 8 8 stations G IR: G4--...... Accessory (pressure gauge) is included, (but not assembled). Thread type (Thread on the manifold base) N F Rc NPT G to 8 stations Common SUP IR: /4, IR: / Individual OUT IR: /8, IR: /4 Individual EXH (From IR body) MPa, MPa and.8 MPa settings can be combined. G-- (IR), G4-- (IR) Note ) Regulators to be manifolded are counted starting from stations on the left side with the OUT ports in front. Note ) When regulators with a different set pressure are manifolded, viewing OUT ports from front, the low pressure range is installed on the left side and high pressure range is on the right side. In case of the Example ) above mentioned, stations and are of MPa setting, stations and 4 are of MPa setting, and station 5 is of.8 MPa setting. Note ) Please consult with SMC when a blanking plate is needed.

Series IR// Specific Product Precautions Be sure to read before handling. Refer to p.-6 and -7 for Safety Instructions and common precautions on the products mentioned in this catalogue. Caution Air Supply. If the supply pressure line contains drainage or dirt, etc., the fixed throttle can become clogged leading to malfunction, and therefore, in addition to an air filter (SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to SMC's "Compressed Air Cleaning Systems" catalogue regarding air quality.. Never use a lubricator on the supply side of the regulator, as this will positively cause the fixed throttle to become clogged and lead to malfunction. If lubrication is required for terminal devices, connect a lubricator on the output side of the regulator. Warning Maintenance. When the valve guide (refer to construction drawing on p..6-6) is to be removed during maintenance, first reduce the set pressure to "" and completely shut off the supply pressure.. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to "". Precautions for IR only Warning. When remounting the valve guide after removing it for maintenance, use a tightening torque of no more than Nm. Since the valve guide on this product is made of resin, there is a danger of damage if tightened with a torque exceeding the prescribed value. Caution Operation. Do not use a precision regulator outside the range of its specifications as this can cause failure. (Refer to specifications.). When mounting is performed, make connections while confirming port indications. Caution Operation. If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side. In the event a directional switching valve will be used, install it on the output side of the regulator. 4. Air is normally discharged from the bleed port (the hole on the side of the body's midsection). This is a necessary consumption of air based on the construction of the precision regulator, and is not an abnormality. 5. Be sure to tighten the lock nut after pressure adjustment. Precautions for IR, IR only Caution. The supply pressure is relatively high (approx. MPa or more), the set pressure is low (approx..mpa or less), and when operated with the output side released to the atmosphere, there may be pulsations in the setting side pressure. In this kind of situation, operate with the supply pressure reduced as much as possible, or increase the set pressure somewhat and restrict the output line (add and adjust a stop valve, etc.).. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc(PT) /. Precautions for IR, IR (air operated style) only Caution. Since the output of types IR and IR is the same pressure as the input signal pressure, select a type of regulator (general purpose or precision type) for input signal pressure adjustment according to the application.. The screw on the topmost section is a zero point adjustment screw which is locked at the factory and requires no adjustment for operation. 9

Series IR// Precision Regulator Precautions Be sure to read before handling. Refer to p.-6 and -7 for Safety Instructions and common precautions on the products mentioned in this catalogue. Warning Piping. Screw piping together with the recommended proper torque while holding the side with female threads. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to piping brackets, etc. causing damage or other problems. Connection thread Torque Recommended proper torque Nm /8 /4 /8 / 7 to 9 to 4 to 4 8 to Piping Caution. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove cutting chips, cutting oil and other debris from inside the pipe.. Wrapping of pipe tape When connecting pipes and fittings, etc., be sure that cutting chips from the pipe threads and sealing material do not get inside. Further, when pipe tape is used, leave.5 to thread ridges exposed at the end of the pipe/fitting. Winding direction Expose approx. threads Pipe tape. Do not allow twisting or bending moment to be applied other than the weight of the equipment itself. Provide separate support for external piping, as damage may otherwise occur.. Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of steel, etc., avoid these problems by using flexible tubing for intermediate connections. Warning Warning Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, water or steam, or where there will be contact with the same.. Do not operate in locations where vibration or impact occurs.. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5. In locations where there is contact with spatter from water, oil or solder, etc., implement suitable protective measures. Air Supply. These products are designed for use with compressed air. Contact SMC if any other fluid will be used.. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt, or corrosive gases, etc., as this can cause damage or malfunction.. If drainage is not removed from air filters and mist separators, it can flow out to the downstream side and lead to the malfunction of pneumatic equipment. In cases where the management of drainage removal will be difficult, the use of filters with auto drains is recommended.

Safety Instructions Caution: Warning: Danger : Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO 444: Pneumatic fluid power General rules relating to systems. ISO 44: Hydraulic fluid power General rules relating to systems. IEC 64-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 8-: Manipulating industrial robots - Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalogue information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.. Do. not service or attempt to remove product and machinery/equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalogue.. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Caution. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or.5 years after the product is delivered, wichever is first. ) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products. ) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E-) before using. SMC Corporation (Europe) Austria +4 ()668 www.smc.at office@smc.at Belgium + ()55464 www.smcpneumatics.be info@smcpneumatics.be Bulgaria +59 ()8767 www.smc.bg office@smc.bg Croatia +85 ()7788 www.smc.hr office@smc.hr Czech Republic +4 54446 www.smc.cz office@smc.cz Denmark +45 759 www.smcdk.com smc@smcdk.com Estonia +7 657 www.smcpneumatics.ee smc@smcpneumatics.ee Finland +58 755 www.smc.fi smcfi@smc.fi France + ()6476 www.smc-france.fr promotion@smc-france.fr Germany +49 ()64 www.smc.de info@smc.de Greece + 7765 www.smchellas.gr sales@smchellas.gr Hungary +6 59 www.smc.hu office@smc.hu Ireland +5 ()49 www.smcpneumatics.ie sales@smcpneumatics.ie Italy +9 97 www.smcitalia.it mailbox@smcitalia.it Latvia +7 67877 www.smclv.lv info@smclv.lv Lithuania +7 5 88 www.smclt.lt info@smclt.lt Netherlands + ()58888 www.smcpneumatics.nl info@smcpneumatics.nl Norway +47 679 www.smc-norge.no post@smc-norge.no Poland +48 ()966 www.smc.pl office@smc.pl Portugal +5 66657 www.smc.eu postpt@smc.smces.es Romania +4 5 www.smcromania.ro smcromania@smcromania.ro Russia +7 8785445 www.smc-pneumatik.ru info@smc-pneumatik.ru Slovakia +4 ()4 www.smc.sk office@smc.sk Slovenia +86 ()78854 www.smc.si office@smc.si Spain +4 984 www.smc.eu post@smc.smces.es Sweden +46 ()86 www.smc.nu post@smc.nu Switzerland +4 ()596 www.smc.ch info@smc.ch Turkey +9 489 44 www.smcpnomatik.com.tr info@smcpnomatik.com.tr UK +44 ()845 5 www.smcpneumatics.co.uk sales@smcpneumatics.co.uk SMC CORPORATION Akihabara UDX 5F, 4-4-, Sotokanda, Chiyoda-ku, Tokyo -, JAPAN Phone: -57-849 FAX: -598-56 st printing SR printing SR Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.