Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Similar documents
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

F l o w c o n T R o l v a l v E S

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

Flow control valves Series RFU - RFO 2/

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

shutoff valves 900 Series psig Manual Shutoff Valves

SO 9001 I ACCESSORIES

Pilot Check Valve: Metal Body Type

Pneumatic Function Fittings Metric & Inch

Clean Speed Controller with One-touch Fitting

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

STC. Push-In Fittings & Polyurethane Tubing. Fine Quality. Precision Engineered Advanced Design. Excellent Prices

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

SOLENOID VALVES AND PNEUMATIC VALVES

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Piloted Non-Return Valves

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Panel-mounted valves Series T, Ø 22.5 mm

Laboratory Flowmeters

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Tools & Installation. Tools & Installation Index

SG3 Series Regulators - Pressure Reducing

Coiling Tube with Twist-Proof Fitting

Push-In Fitting Type Pressure Gauge

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Propor tional Re lief Valve s

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Microregulator 039 1/8-1/4

TONS! powerteam.com HEAVY LIFT CYLINDERS

Choosing the right miniature instrument and control valve is a snap

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Instructions Parts List

PVQ 13 A2 R SE 1 S 20 C-11 D

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

// ADapters GUIDelines

Flow Sensors & Hydrometers Specification Sheet

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

screw fittings - nickel plated brass series SC

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

VACUUM REGULATORS CONTENTS

Pressure Gauge Series

Prestolok PLM Metal Push-to-Connect Fittings

HIGH-PRESSURE RELIEF VALVES

SOLENOID VALVES AND PNEUMATIC VALVES

Techcon Systems TS1254 Pressure Pot

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

INSTRUMENTATION VALVES

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

FILTER TYPE PRESSURE SNUBBER

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Integrated Fittings. Flow Controls. Check Valves. Blocking Valves. Slow Start Fittings. Threshold Sensor Valves

Techcon Systems TS1258 Pressure Pot

INDUSTRIAL EXCESS ESS FLOW VALVES

SG1 Series Regulators - Pressure Reducing

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

CO2 Tank Conversion Kit P.N , P.N , and P.N

CentriFlow Meter Integrated Air Entrainment System

Parker Legris Machine Safety: Product Sheets

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

RESIDENTIAL REGULATORS

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Push-In Fitting Type Silencer

Series K Air service units G 1/8, G 1/4

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

CAST IRON VALVES FLOAT VALVE

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Pressure Dump Valve Service Kit for Series 2300 Units

Speed Controller Constant Flow

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

North American Orifice Metering System

Hand lever valves VHER

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Description Advanced Features Typical Applications

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

REGULATORS FOR SPECIFIC APPLICATIONS

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Smooth Vent Valve XVD. Series

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Air Saving Valve. Pressure Valve Flow Valve

IFP C175-* REMOTE CONTROL RELIEF VALVE

Air service units series K G1/8, G1/4

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Transcription:

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8 Thread Type : 10-2 UNF, 1/8, 1/4, /8, 1/2 NPTF These unidirectional and bidirectional flow controllers have been designed as small as possible to enable mounting directly on valves or cylinders. The flow regulation range is wide and gradual, allowing the regulation to be very accurate either at minimum or maximum flow. GENERAL DATA Construction needle - type Valve group Unidirectional and bidirectional controller (meter-in, meter-out, and needle valve) Materials Nickel-plated brass body, Buna-N seals, Nylon gaskets Mounting Right-angle male thread Installation in any position Operating temperature 2-175 F (dry air necessary down to - 4 F) Operating pressure 1-10 bar (14.5 to 145 psi) Nominal pressure 6 bar (87 psi) Nominal flow see graph Nominal diameter M5 (10-2 UNF) = 1.5mm (.059 ), 1/8 = 2 mm (.079 ) 1/4 = 4 mm (.157 ), /8 = 7 mm (.275 ) Fluid filtered air Lubricant Oil compatible with Buna-N ( - 10 E) *QN flowrate (SCFM) determined with a supply pressure of 6 bar (87 psi) and with a pressure drop of 1 bar (14.5 psi). **Dimensions are in inches 118

Flow Control Valves NPTF Nickel-Plated Brass Flow-Control Valves: NPTF & Coated Threads (Optional) Features Benefits Nickel-Plated, All-metal Collet and Release ring All-Metal, Nickel-Plated body and Threads, Compact Brass bodies from Brass forgings Specialized O-ring choices for High-Temp, Low-Temp, Special Fluids, Food-Grade compatibility Multiple Thread sealant systems: Vibra-Seal Coated (Optional), Std NPTF & O-Ring Spot Face seals Broad Range of configurations Removable Collet and tube o-rings Highly accurate Flow-rate repeatability & Higher Flow Manual Adjustment knob w/ internal hex-key slot or Screw-Driver slot Hex Locking-nut Precise Manual knob, w/ Internal hex-key Full Swivel design, NPTF and Metric/BSP, with integrated Push-In Fittings or Female thread ports Alternate Non-Swivel design with Banjo Tube connections and thread adapters Meter-IN, Meter-OUT and Needle-Orifice flow designs for assembly on valves, cylinders or in-line use Alternate sintered bronze banjo for fully adjustable silencer/muffler with speed control for exhaust port mounting, ( see Part No. 2905 to add to any banjo flow control body) Collet Won t break like plastic release rings and bodies; More Durable design Higher holding force, with easier release Won t scratch tubes like bite-ring designs Less chance of micro-leakage and bubble-leaks over time due to damaged tubing Body Resistant to UV exposure Better resistance to stress-cracking, abrasion, solvents, detergents, hydrocarbons and other fluid media FDA/NSF approved materials, ( Including customized Nickel-Plating and o-ring options) Simplified manifold circuits with broader variety of fitting combinations and shapes to select Lighter weight for End-of-Arm tooling & Robotic handling, Compact design reduces overall dimensions for valve & cylinder assemblies, packaging applications and control cabinets 25 % Reduction in overall Body size, compared to previous Brass-Banjo line Design Accuracy and Repeatability of Flow-Control valves allows timing circuits to be design, faster OEM set-up and simplified MRO field installation and replacements Simplified manifold circuits with broader variety of Tube Thread combinations to select Lighter weight for End-of-Arm tooling & Robotic handling Compact design reduces overall dimensions for valve assemblies, packaging applications and control cabinets More compact flow capacity reduces cylinder spacing with improved overall speed Fine tuning of flow with manual knob or screw-driver adjustment Convertible into Tamper-Proof by removing manual knob or sealing screw-driver slot Interchangeable Inch and Metric Tube O.D. banjo connections and thread adapters for hybrid Fittings and Flow-control valve requirements 119

CODING EXAMPLE GM CU 04-02 GM ACTUATION: GM = swivel body, manual adjustment GS = swivel body, screwdriver adjustment M = manual adjustment, non-swivel banjo S = screwdriver adjustment, non-swivel banjo CU ASSEMBLY: CU = on cylinders (meter out) VU = on valves (meter in) CO = (needle orifice) 04 ATTACHMENTS 2F = 10-2 UNF Female Thread 5 = 5/2 OD Tube 02 = 1/8 OD Tube 02F = 1/8 NPTF Female Thread 04 = 1/4 OD Tube 04F = 1/4 NPTF Female Thread 05 = 5/16 OD Tube 06 = /8 OD Tube 06F = /8 NPTF Female Thread 08 = 1/2 OD Tube 08F = 1/2 NPTF Female Thread 02 Thread 2 = 10-2 UNF 02 = 1/8 NPTF 04 = 1/4 NPTF 06 = /8 NPTF 08 = 1/2 NPTF To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in Nl/min (see cylinder Table); determine the stroke time of the cylinder; refer to graph to see which controller is the right type. 120

Flow Control Valves NPTF METER IN, METER OUT, NEEDLE ORIFICE FLOW CONTROLLERS To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in NL/min (see cylinder Table); determine the stroke time of the cylinder; refer to graph to see which controller is the right type. In the case of bidirectional regulators, refer to the graph and check whether the flow control range is suitable for the work required. (NB: Qn is determined with a supply pressure of 6 bar and with DP = 1 bar at the outlet. N = number of screw turns.) 5-2 04-02 60 NL/min. (2.12 SCFM) 4 NL/min. (1.52 SCFM) 164 NL/min. (5.79 SCFM).0 NL/min. (1.17 SCFM) 5-02 04-04 107 NL/min (.78 SCFM) 28. NL/min. (1.0 SCFM) 67 NL/min (12.96 SCFM) 1.0 NL/min (4.71 SCFM) 121

UNIDIRECTIONAL AND BIDIRECTIONAL FLOW CONTROLLERS To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in NL/min (see cylinder Table); determine the stroke time of the cylinder; refer to graph to see which controller is the right type. In the case of bidirectional regulators, refer to the graph and check whether the flow control range is suitable for the work required. (NB: Qn is determined with a supply pressure of 6 bar and with DP = 1 bar at the outlet. N = number of screw turns.) 06-04 06-06 466 NL/min. (16.45 SCFM) 15 NL/min. (5.40 SCFM) 875 NL/min. (0.90 SCFM) 428 NL/min. (15.11 SCFM) 08-08 Flow Qn (Nl/min.) from 2 1 with needle OPEN: 2570 (90.75 SCFM) Flow Qn (Nl/min.) from 2 1 with needle CLOSED: 10 (46.95 SCFM) NB: Qn is determined with a supply pressure of 6 bar and with DP = 1 bar at the outlet N = number of screw turns. (SCFM) Qn (Nl/min) 105 87.5 70 52.5 5 17.5 122