Liquid Abrasive Pressure Pot Scoping Tests Report

Similar documents
-7t. CO, Pellet Blasting Studies. Idaho National Engineering Laboratory. Kip E. Archr';bald INEL/EXT

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

st Symposium of Northeastern Accelerator Personnel A TIMESHARED FORELINE AND ROUGHING VACUUM SYSTEM. Oak Ridge, TN

Gas Sampling in the DST

Regulatory Concerns for Leakage Testing of Packagings with Three 0-Ring Closure Seals

~ goss7-- OSTI RECEIVED LEAKAGE TESTING OF PACKAGINGS WITH THREE-O-RING CLOSURE SEALS. c=t) SUMMARY INTRODUCTION

@ -4 Inventors: Daniel L Mensink 3578 Gregory Lane Lynchburg, Virginia 24503

Vacutrans Instructions

DISCLAIMER. Government. Neither the United States Government nor any agency thereof, nor any of their

Alkylphosphines. Storage and Handling Recommendations

Installation Instructions JATCO Environmental Protection Tank Model J-7000

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

HIGH SPATIAL RESOLUTION NEUTRON IMAGING OF INERTIAL FUSION TARGET PLASMAS USING BUBBLE DETECTORS

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Operating the LCLS gas attenuator and gas detector system with apertures of 6 mm diameter

THE SAT BLAST SYSTEM

QUARTERLY REPORT NO. 3 DE-FG22-94PC /01/95

HYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

INTEGRITY MANAGEMENT OF STRESS CORROSION CRACKING IN GAS PIPELINE HIGH CONSEQUENCE AREAS

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

OWNER S MANUAL SUCTION GUN SG-300

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

SIGMAGUARD CSF 575. PRODUCT DATA SHEET September 14, 2015 (Revision of September 14, 2015) DESCRIPTION

Air Operated Hydraulic Pumping Systems to 50,000 psi

two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Success Paths: A Risk Informed Approach to Oil & Gas Well Control

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

POWER FLUSH KIT INSTRUCTIONS

1. CONDITIONS FOR USE 2. SAFETY

two component solvent free amine cured phenolic epoxy coating

Pixel Thermographics Ltd. Compressed Air Leak Detection Survey SAMPLE REPORT. Pixel Thermographics Ltd

VACUUM EXCAVATION BEST PRACTICE & GUIDELINE

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

VRS Assembly & Operating Instructions

Irrigation System Winterization and Pressurization Procedures

Cylinder Adhesive for Geotextile Seaming

C-Series. Pirate Brand. Product Line Brochure 3.0 / 6.0 CU FT - ABRASIVE BLASTERS. Proudly Distributed By: Rev. May 16

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

ATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

Liquid Nitrogen for Duct Cleaning

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

TECHNICAL DATA. than the water inlet pressure to the concentrate

ASSE International Product (Seal) Listing Program

Essa Certified Pressure Filters

The Cyclone Tire Deflation & Inflation Tool

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

Agricultural Water: Part 2

Hardener: at least 24 months when stored cool and dry

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

ATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Cylinder Spray Adhesive - User s Guide

COMPRESSED AIR DISTRIBUTION SYSTEMS

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ASSE International Product (Seal) Listing Program

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

WARNING! Crystalline silica from bricks, cement and other masonry products

Venting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Compressed Gases and Cryogens

I have to say that I had no idea about compressors. That means it s easy for everybody.

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

TDUX Inflatable Duct Sealing System 1.0 General Product Information

DIAPHRAGM PUMP MODEL PDM 1-175

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

SAFETY DATA SHEET Section 1: Product Identification

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Dewatering Landfill Gas Wells to Maximize LFG Collection

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

ES&H Manual Pressure and Vacuum Systems Safety Supplement

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Seat Tightness of Pressure Relief Valves

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

MATERIAL SAFETY DATA SHEET

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Pump On Demand. Skimmer System

Gas Lift Valve Testing

Neotecha Tank Sampling Sapro

MATERIAL SAFETY DATA SHEET

2 I All-Flo Pump Co.

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

GUIDELINES FOR SLUG DISCHARGE MANAGEMENT PLAN (Abstract from EPA Guidance Manual)

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

Transcription:

INEL-96/0017 January 1996 Idaho National Engineering Laboratory Liquid Abrasive Pressure Pot Scoping Tests Report K E. Archibald

INEL-96/0017 Liquid Abrasive Pressure Pot Scoping Tests Report K. E. Archibald Published January 1996 Idaho National Engineering Laboratory High Level Waste Engineering & Project Management Lockheed Idaho Technologies Company Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Under DOE Idaho Operations Office Contract DE-AC07-941D13223 tlh DISTRIBUTION OF THIS WCUMEIUT IS UNLJMITED

CONTENTS Introduction... Objectives... Setup... Testing... Results...3 Recommendations...,...6 Conclusion...8 TABLE 1. LAPPTestingResults...4 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. iii

Liquid Abrasive Pressure Pot Scoping Tests Report Introduction The primary initiatives of the LITCO Decontamination Development group at the Idaho Chemical Process Plant (ICPP) are the development of methods to eliminate the use of sodium bearing decontamination chemicals and minimization of the amount of secondary waste generated during decontamination activities. In July of 1994, a Commerce Business Daily (CBD) announcement was issued by the INEL to determine commercial interest in the development of an in-situ liquid abrasive grit blasting system. As a result of the CBD announcement, Klieber & Schulz issued an Expression of Interest letter which stated they would be interested in testing a prototype Liquid Abrasive Pressure Pot (LAPP). LITCO's Decontamination Development group and Kleiber & Schulz entered into a Cooperative Research and Development Agreement (CRADA) in which the Decontamination Development group tested the prototype LAPP in a non-radioactive hot cell mockup. 0 bjectives The objectives of this scoping test included: Determine the ease of setup and operation of the system. Determine the effectiveness of the LAPP for decontaminating various surfaces including tanks, piping and cell walls. Determine the effectiveness of the vacuum recovery system in collecting the used abrasive and returning the abrasive into the blast pot for reuse. Determine the effectiveness of various abrasives when used with the LAPP. Determine the effectiveness of controlling the amount of airborne dust and particulate by using a small.amount of liquid. 1

6) Determine the amount of secondary waste generated. 7) Make recommendations to improve the LAPP for hot cell use. Setup The hot cell mockup was a 6' wide x 11' long x 6' high room constructed of stainless steel which contained stainless vessels and piping arranged to simulate an actual hot cell. Stainless steel coupons with simulated fixed contamination (SIMCON) were attached with sealant in sets of three to the wall, pipe and tank surfaces inside the hot cell mockup. The LAPP system has a foot print of 5' x 5' and stands approximately 5' tall. The main blasting system is on wheels and can be moved to the area where the blasting is performed. This system operates by placing abrasive with a small amount of water in the pressure vessel and then pressurizing it with air. This pressure closes off the top opening with a. pop up valve. A valve at the bottom is then opened allowing the abrasive slurry to go through the hose to the blasting nozzle. A trigger on the nozzle is used to start the blasting. The preferred compressed air requirement for this system is 250 cfm at a maximum pressure of 100 psi. The minimum air requirement for blasting is 165 cfm at approximately 60 psi. The ICPP plant air did not meet the minimum air requirements to operate the system so an air compressor was used. The abrasive slurry used in this system can contain a variable percentage of water and grit depending how aggressive the slurry needs to be to clean the material. The LAPP uses a recycling process to reduce the amount of liquid and solid waste generated. A vacuum system collects the used grit and water and returns it to be reused. The vacuum system can stand alone or can be.placed over the main blasting system for easier reuse. The vacuum system, which stands 10 ' tall, was placed to the side of the blasting system for these tests. A bucket was placed inside a drip pan under the vacuum to collect the used grit. The LAPP system and vacuum were 'located outside of the mockup cell area while the slurry and vacuum hoses were routed inside. Testing The LAPP.testing was started by using.two 50 Ib bags of glass beads (Cataphote Inc. EGS, designation #6) with water to the pressure pot, using a ratio of 2

1 :85 gal. of glass beads per.92 gal. of water (ratio 2 to 1) for the first bag. The second bag was. added using a ratio of 4 to 1 glass beads to water. These were the least aggressive of the various abrasives available. A % inch diameter air supply line was then connected from the blasting system to the air compressor. When the compressor was started and the blast lever was placed to the on position, the pop-up valve didn't respond.. It was.determined that a larger air supply line. was needed and a 1 inch diameter airsupply hose was used. The blast lever was then placed to the ON position and the pop-up valve sealed off the pressure vessel. Because of air compressor limitations, the maximum blast pressure obtained was 60 psi. When the trigger on the blast nozzle was first pulled there was only a small amount of abrasive being discharged from the nozzle. The abrasive valve, which is located at the bottom of the blasting system, was adjusted so that more abrasive could be released. The system was used to blast a stain on the stainless steel floor of the rnocklup until sufficient abrasive reached the nozzle. The coupons were then blasted at different distances, angles, and times to determine'the overall cleaning efficiency and metal degradation. After the coupons had been blasted, the abrasive was vacuumed up from the floor. The vacuum was very effective and easy to use but the lack of wheels made it difficult to move to the correct area. Operation of the LAPP system required a minimum of two people; one person to work the blasting nozzle and one to watch the gauges and control the equipment. The blasting nozzle was easily controlled with very little kick back when the trigger was pulled. The hoses.would had to be manipulated to prevent a tripping hazard and entanglement around the vessels or piping. Results The entire LAPP system was very easy to operate. The system generated very little liquid waste and the only secondary waste generated were the blast beads. The cleaning results from this test are depicted in Table 1. These results indicated that the LAPP system is very effective and is a fast method to use to decontaminate stainless steel. All of the coupons were blasted to a shiny finish. The only set of coupons that were not cleaned were the set of three that were located approximately 1 foot from a set that were being blasted. This set of coupons were used to determine the amount of over spray during.blasting. These coupons were cleaned to small degree which would indicate that the system is still producing some cleaning at a.radius of at least 1 ft. The results from the EGS glass beads indicated that testing the more aggressive abrasives was not necessary as all coupons were below detectable limits. 3

The total amount of beads collected after vacuuming was 13 pounds (used during 13 total minutes of blasting at 1 Iblmin). A small amount of glass beads were left on the inside of the vacuum but the majority of the beads remained in the blasting system despite operation of the system until no further abrasive exited the nozzle. These probably could be flushed out using water when cleaning was needed or blasted out if the water ratio was increased during operation. The different ratios of water and grit didn't seem to effect the cleaning efficiency of the system. During blasting there was a slight mist present but not enough to block the vision of the operator. The operator did indicate that he could feel the beads hitting him as they bounced off the wall. When blasting was complete the prefliters were weighted and checked to see how much grit or material had reached the filters. The results showed that the filters had only increased by a few grams. This indicated that the majority of the material and grit stayed inside the cell. TABLE 1 LAPP Testing. Results Coupon # PP-2-159 PP-2-013 Blasting Blasting Blasting Angle Time Distance From Surface PP-2-007 1 P I 30 I 6" PP-2-014 1 P I 2. I 18" %Cs Before (ug) - 100 100 100 101 PP-2-115 I P I,",",. I 18" PP-2-002 1 45 I,",", I 6" 103 104 4

~~~ Coupon # Blasting Angle From Surface Blasting Blasting Time Distance -qt- %Cs Before (us) PP-2-026 45 105 %Zr Before (ug) %Cs After (ug) %Zr After (ug) I PP-2-011 45 106 30 6" PP-2-032 P 30 PP-2-130 P 30 P P-2-04 1 P 30 PP-2-008 30 PP-2-102 30 P P-2-048 30 PP-2-121 PP-2-001 P P' I 30 6" I 30 6" I 30 6" I lo 12" I lo 12" I PP-2-125 P 10 12" PP-2-036 P I 30 12" PP-2-157 P 30 1 12u PP-2-018 PP-2-114 PP-2-086 P P I 30.12" 36 " 109 74 I 36 " 110 140, 36 " 110 59 I 113 57 I 113 85 114 ~~ 115 116 116 117 120 122 84 I 61 I 92 I 58 I I min. I 12" 123 49 I P I min. I 12" 124 58 I 5

Coupon # Blasting Angle From Surface Blasting Time Blasting Distance %Cs Before (ug) %Zr Before (ug) PP-2-080 P 1 min. 12 127 81 n/a n/a n/a I 132 I 153 40 120 n/a n/a 50 40 PP-2-124 (ns) n/a n/a 70 80 = Below detectable limits. (ns)= Not sprayed. P=Perpendicular from the surface. Recommendations The following are recommendations for improvements to the LAPP system to. allow it to be used at its full potential in a hot cell environment. A. Pressure Pot: Air Flow-Reaulator - The current system needs a separate airflow regulator to indicate the amount of flow going to the blast system. Incorporation of a separate air flow regulator would be a great.benefit when using this system in a cell since not-all air supply lines have air flow regulators. Pressure Gauae - The pressure gauge located on the system should indicate a minimum and maximum pressure range in psi. The incorporation of this type of gauge would help determine the proper pressure when operating the system. Air Flow - Redesign of the system to operate at lower air flows is needed. The current flow requirements of the system are to large for standard plant air. Blastina Sv stem - The system is difficult to move with one person. A smaller system may be more practical for in cell use. The smaller unit would require less 6

air flow to operate and the hoses and nozzle would be smaller which would making it easier o r an operator touse. Shroud - The shroud that is located on the bottom of the vacuum is small. Whn. transferring used abrasives from the vacuum to the blast system, the shroud would have to cover the entire-top of the blast system to ensure all the abrasives and water were contained during the transfer. Material - The system will have to be decontaminated after it has been used in a * contaminated environment. To make it easier to decontaminate, the system should be constructed of'nan-painted stainless steel. Abrasive'Batl Valve - The ball valve.should have some kind of labeling which would tell the operator if the valve is closed or to what extent it is open. Abrasive Removal - The removal of unused abrasive from the pressure pot is difficult. To make it easier, to remove thereneeds to be a easier way to get inside the pressure pot. Water Level Indicator - The system needs a visible water level indicator to tell the operator when the system is full. Covet - The top of the blasting-system needs a removable cover to prevent the spread of contamination when the.systeh is started or stopped. Blast. Hose - The blast hdse needs a hard connection to the pressure pot to prevent leaking. B. Vacuum: Wheels -. The. vacuum should.be made more mobile by adding wheels with locklng :devices. Material'- The vacuum system- should be constructed of stainless steel where possible. This will make it easier to decontaminate after. it hasjeen used.,. Filters. - The filter should be easier to replace. Alt filters must be DOP tested before they are used. The system should include a gauge to tell the operator. when the filter needs to.be changed..bevel Indicator - The vacuum needs a level indicator to tell the operator whether it is empty or full. 7

Lever - The closing mechanism on the bottom of the vacuum doesn't seal completely. When the vacuum is not located over the blasting system, it must be able to hold all the abrasive in the vacuum even if the air supply is shut off. Conclusion The Lapp system is a very effective and fast cleaning/decontamination method. The system could be used for industrial cleaning without any modifications. However, improvements to system would have to be made to allow it to be used at its full potential in radioactively contaminated areas. 8