Certificate of Conformity

Similar documents
Certificate of Conformity

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

IECEx Certificate of Conformity

TYPE APPROVAL CERTIFICATE

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

Certificate of Compliance

IECEx Certificate of Conformity

Orifice Plate Flow Meter

Torque Tube TB300 Digital Transmitters

CERTIFICATE OF COMPLIANCE

Differential pressure

Certificate of Compliance

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Pressure Measurement Single-range transmitters for general applications

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Technical Data. General specifications. Rated operating distance s n 2 mm

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

IECEx Certificate of Conformity Annexe

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

IECEx Certificate of Conformity

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Online data sheet FLOWSIC30 GAS FLOW METERS

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Technical Explanation

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Data. Dimensions

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

ELECTRIC ACTUATORS for continuous underwater use

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Pressure Measurement Single-range transmitters for general applications

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Multi Vision. Digital Transmitter 10/ EN

ENGLISH SAFETY INSTRUCTIONS FOR PRESSURE TRANSMITTERS MODELS 6X1ED - EE - EH - EG - EA, 622ED, 6X1ES

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Technical Data. General specifications. Rated operating distance s n 5 mm

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

9700 Transmitter Submersible hydrostatic level transmitter

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

ATM.1ST/Ex - High Precision Transmitter

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

deltaflowc deltaflowc Venturi or Probe

TYPE APPROVAL CERTIFICATE

Additel 761 Automated Pressure Calibrators Selection Guide

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

VG5 Supplementary instructions

Technical Data. Dimensions

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Field Instrumentation Training Strategy

Hydrostatic Level and Pressure Measurement

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure switch, Differential pressure switch and Thermostat RT-E

Electronic Volume Correctors

Level transmitter LT 100

NivuBar Plus II

Additel 761 Automated Pressure Calibrators Selection Guide

200A Series ELECTRONIC LEVEL TRANSMITTER

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Operating Instructions

Technical Data. Dimensions

MANUAL KPS Pressure Control Valve

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

SITRANS P pressure transmitters The best in pressure measurement. sitrans

Technical Data. Dimensions

3.0 Pressure Transmitter Selection

RTD temperature probes

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Pressure Transmitter P41

Programmable pressure and temperature transmitters PTM/RS485

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

Ultra High Purity Model 780S

Yokogawa Systems and PCI Training

Programmable Submersible Level Transmitters

Design Features. General Description

Technical Data. Dimensions

Transcription:

Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols: Hart, Profibus, Fieldbus Foundation, Modbus Zone 1: Ex d Zone A21: Ex td Marking Code: Zone 1: Ex d IIC T6 (T amb +75 C) IP66/IP67 Zone A21: Ex td A21 T85 (T amb +75 C) IP66/IP67 Manufacturing Location(s): ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY The EPEE certification database located at http://www.anzex.com.au shows the validity of this Certificate. Certificate issued by: ABN 94 084 639 032 TestSafe Australia 919 Londonderry Road, Londonderry NSW 2753 Australia Phone: +61 2 4724 4900 Fax: +61 2 4724 4999 http://www.testsafe.com.au Accreditation by the Joint Accreditation System of Australia and New Zealand Acc No. Z2221100AS Page 1 of 7

This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87:2004. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0:2004 AS/NZS 60079.0:2005 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 60079-1:2003 AS/NZS 60079.1:2005 IEC 61241-0:2004 (AS/NZS 61241.0:2005) IEC 61241-1:2004 (AS/NZS 61241.1:2005) IEC 60529:2001 (AS 60529:2004) Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosure d Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures td Degrees of protection provided by enclosures (IP Code) This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. ASSESSMENT & TEST REPORTS: The equipment listed has successfully met the assessment and test requirements as recorded in: Test Report No. and Issuing Body: TestSafe 26678 in TestSafe 2004/001677 Quality Assessment Report No. and Issuing Body: IECEx QAR TUN 04.0005 File Reference: 2006/030419 15/12/2006 Signed for and on behalf of issuing body Date of Issue Quality & Certification Manager Position This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. Page 2 of 7

Schedule EQUIPMENT: The Pressure Transmitter 2600T series is used for measuring and converting physical values like pressure and differential pressure into an analogous electrical standard signal of a 4-20 ma current loop and digital communications according to HART, Profibus, Modbus or Fieldbus protocols. It may contain an optional LCD display within the enclosure, or an output meter connected to the field terminal block. This latter option is not within the scope of this certificate. An optional multivariable board allows measurement of temperature using an externally connected temperature sensor. The transmitter has a main enclosure provided with two end caps. Three different shapes are available for the main enclosure EU-p, EU-dp, US. They are available in aluminium alloy or stainless steel materials. The main enclosure contains a terminal board located in the connection area, with a blind end cap. The main enclosure also contains a main board and optional display board in the electronic area, with a blind or windowed cap The transducer assembly is screwed to the main enclosure. This assembly contains a characterisation board connected to but isolated from the capacitive or piezo-electric pressure sensing element by cemented joint or feed-throughs. The sensing element itself is connected to the process pipes during the installation. The transducer varies in shape. The pictures titled EU-p shows an absolute pressure transducer, EU-dp shows a gauge pressure transducer, and US shows a differential pressure transducer. The transducers have the following pressure sensors with associated characterisation boards: - p-piezo - dp-cap - dp-piezo - hp-piezo The complete range of transmitters and the associated identification code is provided in the schedule of this certificate. Page 3 of 7

Schedule of equipment covered in this certificate: Code: 265..Absolute Pressure, Gauge Pressure 26abcdxxxx(x)(x)(x)(x)isx +options + remote seal (see drawing V15753X37) a Performance figure: 5 b measure type and construction: A, G A = Absolute Pressure G = Gauge (Relative) Pressure c application: C, R, S, J, G, M, N d upper range limit: L, R, U, V, D s electronic housing: A, B, S, T, J, 1 A = US Aluminium B = US Aluminium S = US Stainless Steel T = US Stainless Steel J = EU Aluminium 1 = EU Aluminium options remote seal according to document MLC0001 (2600T options) according to document CLC0040 Page 4 of 7

Schedule of equipment covered in this certificate continued: Code: 265..Differential, Differential absolute, Differential and Pressure 26abcdxxxx(x)(x)(x)(x)sx +options + remote seal (see drawing V15753X37) a Performance figure: 5 b measure type and construction: D, V D = Standard Differential Pressure V = Absolute Pressure c application: C, R, S, J, G, M, N d upper range limit: L, R, U, V s electronic housing: A, B, S, T, J, 1 A = US Aluminium B = US Aluminium S = US Stainless Steel T = US Stainless Steel J = EU Aluminium 1 = EU Aluminium options remote seal according to document MLC0001 (2600T options) according to document CLC0040 Page 5 of 7

Schedule of equipment covered in this certificate continued: Code: 267.. / 269.. with Multivariable 26abcxxxxx(x)(x)(x)(x)sx +options + remote seal (see drawing V15753X37) a Performance figure: 7, 9 7 = Low Accuracy 9 = High Accuracy b measure type and construction: C, J C = Differential Pressure + Multivariable J = Differential Pressure + Multivariable without Flow evaluation c application: C, R, S s electronic housing: A, B, S, T, J, 1 A = US Aluminium B = US Aluminium S = US Stainless Steel T = US Stainless Steel J = EU Aluminium 1 = EU Aluminium options remote seal according to document MLC0001 (2600T options) according to document CLC0040 Conditions of Certification: There are no specific conditions to the use of this certificate. Page 6 of 7

DOCUMENTS: Document Number Document Title Revision Date V15712 X214 (4) ANZEx Label Ex d 1 11/12/2006 V15712 X215 Instruction Manual 2600T Pressure Transmitter Models 1 11/12/2006 267../267../269.. Addendum For Ex Safety Aspects and IP Protection (Australia) V15753 X34 Measuring Transmitter MV 2 06/12/2005 3 pages V15753 X37 Transmitter Coding XP 3 12/12/2006 2 pages 2-9157 X7 (2) Pressure Transducer 2 11/08/2005 2-9158 X5 (2) Differential Pressure Transducer 1 13/11/2003 range <=10 mbar; <=PN6 bar 2-9158 X6 (3) Differential Pressure Transducer 1 13/11/2003 2-9159 X5 (2) Differential Pressure Transducer 1 13/11/2003 range >=10 mbar; <=20 bar; <=PN410 bar 2-9160 X7 (2) Differential Pressure Transducer 1 13/11/2003 range >=100bar; <=PN410bar 685233 (4) B Inspection Window, Coated 4 23/11/2001 MLC0001 Minden Lenno General Code 0 04/07/2002 13 pages IM 267C/269C 31 pages Operating instructions 2600T Series Pressure Transmitters Model 267C Model 269C A 06/2003 Page 7 of 7