Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Similar documents
Directional Controls

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Directional Controls

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

PVQ 13 A2 R SE 1 S 20 C-11 D

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

SystemStak Valves. ISO4401 Size 02

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Directional Valves. Hydraulic Operated Directional Valves

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Electrically Operated Pressure-Relief Cartridge, Size 10

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Pressure reducing valve, pilot operated, Model 3DR

Leak free Pipe Rupture Valve for Excavators

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE SEQUENCE VALVE TYPE UZK

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Cover headline. Cover subheadline. Check Valves

IFP C175-* REMOTE CONTROL RELIEF VALVE

Target Cleanliness Worksheet. Systemic Contamination Control

Proportional Pressure-Relief Cartridge Valve, Size 2...4

VSD03M DIRECTIONAL CONTROL VALVES

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure reducing valve, direct operated

Inverse Proportional Pressure-Relief Cart., Size 2 4

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cartridge, Size 10

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Full Range Pressure Compensating Variable Flow Control

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Pilot Operated Check Valves

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Leak-Free Load-Control Valve SAE ½ psi flange

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Pressure reducing valve, direct operated

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

005 Series Modular Valves

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Digital directional & flow control valves D-DF(R)G

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Intrinsically safe solenoid valves on/off controls - ATEX certification

directional control valve series cv691

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Motion Controls Valve locator

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure reducing valve, pilot operated

P.C. Flow Regulator Valve Series FR101. General Description

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Pilot Operated Check Valves Catalog Quick Reference

Directional Control Valves Technical Information Model 1500

Chapter 10: Bidirectional Flow Controls

Whisper Pump Service and Repair Guide

PRESSURE COMPENSATORS TECNORD

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

PVK OPEN LOOP PUMPS. Bulletin E

SDM to 8 sections monoblock valve D1WWDA02A

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

PLD 03 T A CASAPPA S.p.A.

Double Pilot Operated Cartridge Check Valve, Size 8

Cartridge Valves Technical Information Proportional Valves Quick Reference

Proportional Throttle Cartridges, Size 16

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Operation Manual Piston Sensed Gas Pressure Regulators

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

SPECIFICATIONS ATTENTION

Directional Controls

Monoblock Directional Control Valve RMB 202

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Lesson 6: Flow Control Valves

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

RP series Rotor Pumps

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

3-Way Pressure-Reducing Cartridge, Size 2 4

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Installation Instructions

SERVICE INSTRUCTIONS P-2 DUAL PRESSURE COMPENSATOR, SERIES F1U CONTROL

Controllers DR, DP, FR and DFR

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Transcription:

Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A

Introduction These stackable modules are designed for use with directional valves having an NFPA-D8 interface (ISO-441-8) such as Vickers DG5S-8 directional valves. All circuit flow paths are contained within the control valve and modules, thereby creating a pipeless, simplified, space-saving system. Single station subplates are available for mounting the modules. Modules available are: relief valve, sequence, reducing, flow control and pilot operated check valves. External plugs are SAE straight thread. The Vickers stack valves possess the characteristics expected of the best industrial products in today s marketplace. For over 7 years, the Vickers name has been synonymous with long trouble-free service. Ratings Maximum operating pressure: 21 bar (3 psi) Flows: DGC*-6...... 227 l/min (6 USgpm) DGC*-H6.... 34 l/min (9 USgpm) DGX-6....... 113 l/min (3 USgpm) DGX-H6..... 265 l/min (7 USgpm) DGR-6, DGFN-6, DGPC-6..... 227 l/min (6 USgpm) Modular Valve Circuitry Guide To achieve optimum system performance with modular valves, it is essential that the basic principles of hydraulic circuitry be followed, particularly with respect to the location of individual modules relative to others in the circuit. In considering these relationships we can put the modules into two groups A and B (below). Group A Valves acting in the pressure and/or tank lines: DGC-6....... System relief valve module DGR-6....... Sequence valve module DGX-6....... Pressure reducing valve module The general rule in this group is that the DGR-6 or DGX-6 valve module be placed nearest the directional control valve. The furthest valve would be the DGC-6 system relief valve module (right). a b P T A B Pilot Operated Directional Valve DG5S-8 Pressure Reducing Valve DGX-6 Pressure Sequencing Valve DGR-6 Pressure Relief Valve DGC-6 Sol a Sol b X P T Y B A Subplate Group B Valves acting in the service lines: DGFN-6...... Flow regulator valve module (meter-out) DGPC-6..... Dual pilot operated check valve module The general rule for group B is when using a DGPC-6 with a DGFN-6 (meter-out), the DGPC-6 should be nearest the directional valve (right). a b P T A B Pilot Operated Directional Valve DG5S-8 Pilot Operated Check Valve DGPC-6 Sol a Sol b Flow Control Valve DGFN-6 Free Flow Pressure Relief Valve DGC-6 X P T Y B A Subplate

Contents DGC-*6 Pressure Relief Module............................................................................... 4 Model Code................................................................................................ 4 General Data............................................................................................... 4 Application................................................................................................. 4 Ratings.................................................................................................... 4 Installation Dimensions...................................................................................... 5 DGC5-*6 Solenoid Controlled Relief Modules................................................................... 6 Model Code................................................................................................ 6 General Data............................................................................................... 6 Application................................................................................................. 6 Ratings.................................................................................................... 6 Electrical Service............................................................................................ 7 Installation Dimensions...................................................................................... 7 Performance Curves......................................................................................... 8 DGR-6 Pressure Sequence Module............................................................................ 9 Model Code................................................................................................ 9 General Data............................................................................................... 9 Application................................................................................................. 9 Ratings.................................................................................................... 9 Installation Dimensions..................................................................................... 1 DGX-*6 Pressure Sequence Module........................................................................... 11 Model Code............................................................................................... 11 General Data.............................................................................................. 11 Application................................................................................................ 11 Ratings................................................................................................... 11 Performance Curves........................................................................................ 12 Installation Dimensions..................................................................................... 13 DGFN-6 Flow Regulator Module.............................................................................. 14 Model Code, General Data, Application, Ratings, Installation Dimensions.......................................... 14 DGPC-6 Pilot Operated Check Module........................................................................ 15 Model Code............................................................................................... 15 General Data.............................................................................................. 15 Application................................................................................................ 15 Ratings................................................................................................... 15 Installation Dimensions..................................................................................... 16 DGSM-8 Single Station Subplates & Mountings................................................................. 17 General Data.............................................................................................. 17 Ordering Procedure........................................................................................ 18 Installation Dimensions..................................................................................... 18 Application Data............................................................................................. 19

Pressure Relief Valve Module Model Code 1 2 3 4 5 6 1 Relief Module 2 Flow Omit if not required H - High flow type 3 Module Size 6-3 / 4 inch General Data These relief modules limit system pressure by directing pump flow to tank when system pressure reaches the setting of the module and thus preventing overloading of the system. In addition to conventional overload relief module operation, two other features are provided: System pressure may be limited to relatively low venting pressure by directing flow from the vent connection to tank. System pressure may be remotely controlled by directing flow form the vent connection to a remote control pressure relief valve (C-175-*-2*). Application Pressure Setting The pressure setting of the relief module selected should be approximately 1 to 14 bar (15 to 2 psi) above the actual system working pressure. A higher setting will waste power and impose unnecessary strains on the pump and other system components. Pressure Adjustment Pressure is adjusted by loosening the jam nut and turning the adjusting screw. Clockwise rotation increases pressure, counterclockwise rotation decreases pressure. 4 Pressure Range B - 8,6 to 7 bar (125 to 1 psi) C - 35 to 14 bar (5 to 2 psi) F - 1 to 21 bar (15 to 3 psi) 5 High Vent Spring Omit if not required V - Required on high flow H models Ratings Flow: DGC-6....... 227 l/min (6 USgpm) DGC-H6..... 34 l/min (9 USgpm) Tank & Drain Port Both must be piped directly to tank through a surge-free line. Tank line applications where back pressure is required to provide pilot pressure for the open center DG valve spool, may have back pressure, but not to exceed 5 bar (75 psi). Any back pressure on the tank line must be added to the relief valve setting. Drain line (Y port) must be piped so there will be no back pressure at this port. Transient pressure must not exceed,35 bar (5 psi). Pressure Drop Through the module at 17 l/min (45 USgpm) and 21 cst (1 SUS) is 1,2 bar (18 psi). Weight DGC-6....... 9,1 kg (2 lbs.) 6 Design Number Subject to change. Installation dimensions remain as shown for designs 6 through 69. Pressure Relief Valve Graphical Symbol Vent Gage X P T Y B A

DGC-*6 Pressure Relief Installation Dimensions shown in millimeters (inches) T Tank port 11,2 (.44) 53,1 (2.9) 13, (5.12) 94,5 (3.72) P Pressure inlet port 21 bar (3 psi) max. 7,14 (.281) Dia. 7,9 (.31) deep 2 holes for valve rest pins. 62, (2.44) 26,2 (1.3) Vent connection.5625-18 UNF-2B (leave vent connection plugged except when circuit indicates a connection for venting relief valve. 96,8 (3.81) 92, (3.62) 29,5 (1.16) 77, (3.3) Cyl. port A External pilot pressure port X 93, (3.66) Y Pilot valve drain port (must be piped directly to tank). 14,3 (.562) Dia. thru - 6 holes for mounting module with valve. 11,2 (.44) R Cyl. port B Pressure adjustment control (end cap can be used in either position shown). DG Control valve mounting surface 152,4 (6.) Pressure gauge connection.4375-2 UNF-2B thd. 23,2 (8.) 176,8 Fully extended (6.96) 114,3 (4.5) 35,1 (1.38) 53,8 (2.12) D 69,8 (2.75) 115,1 (4.53) DGC-6 Mounting surface (seals furnished) 2 Rest pins (see subplate for location). (.25) D (.25)

Solenoid Controlled Relief Modules Model Code 1 2 3 4 5 6 7 8 9 1 11 1 Relief Module Solenoid controlled 2 Flow Omit if not required H - High flow type 3 Module Size 6-3 / 4 inch 4 Pilot Spool Function - See graphical symbol. General Data These valves are generally used for applications requiring an electrically controlled adjustable pressure relief or regulating valve to limit the pressure in an oil circuit to the desired maximum. The valves provide a wiring cavity located in the DG4V pilot directional valve. A ground terminal is provided as shown. Solenoid Indicator Light An indicator light is available with most voltages. The light is on when there is current at the solenoid. On spring offset models, light is on solenoid a end only. The conduit connection readily adapts to connector-receptacle assemblies on the market. Solenoid Energizing Solenoids must be held energized for a desired action. Spring offset models have an internal spring which offsets the 5 Pilot Spool Spring Arrangement A -Spring offset. 6 Pressure Range B - 8,6 to 7 bar (125 to 1 psi) C - 35 to 14 bar (5 to 2 psi) F - 1 to 21 bar (15 to 3 psi) 7 High Vent Pressure Omit if not required V - Required on high flow H models 8 Flag Symbol Electrical features and options. valve spool when solenoid is de-energized. Notes Any sliding spool valve, if held shifted under pressure for long periods of time, may stick and not spring return due to fluid residue formation, and, therefore, should be cycled periodically to prevent this from happening. Surges of oil in a common tank line serving these and other valves can be of sufficient magnitude to cause inadvertent shifting of the pilot spool of the valves. Separate tank lines or a vented manifold with a continuous downward path to tank are necessary. Application Tank Conditions The tank connection should be piped directly to tank to minimize back pressure. Any back pressure in the tank line is additive to the valve pressure setting. If tank line back pressure exceeds system pressure by 7 bar (1 psi) a malfunction may occur. Transient 9 Electrical Options W - 1 / 2 NPT thread, wiring housing port. WL - 1 / 2 NPT thread, wiring housing port with solenoid indicator light (B & D solenoids only). 1 Coil Identification Letter B - 115/12/6, 11/5. Indicate other voltages and frequencies by suitable letter. (see chart under Electrical Service) 11 Design Number Subject to change. Installation dimensions remain as shown for designs 7 through 79. pressure peaks in the tank line must not exceed 175 bar (25 psi). Drain Y port must be piped directly to tank through a surge free line such that there will be no back pressure at the valve drain port. Transient pressure must not exceed,35 bar (5 psi). Ratings Flow: DGC5........ 227 l/min (6 USgpm) DGC5-H6.... 34 l/min (9 USgpm) Weight DGC5........ 11,2 kg (25 lbs.) Solenoid Controlled Relief Valve Graphical Symbol Gage Vent a B A T P X P T Y B A

Electrical Service Solenoids are identified by a letter in the model number. Example: DGC5-6A-C-M-W-B-7 (See chart below for solenoid voltage ratings and coil identification letters.) Solenoid Voltage Rating 115/12 VAC 6 Hz 11 VAC 5 Hz 23 VAC 6 Hz 22/23 VAC 5 Hz Identification Letter Inrush Amps (R.M.S.)* B 2. D 1. Holding Amps.54.64.27.32 Holding Watts 6 VDC F 6.8 41 12 VDC G 3.5 41 24 VDC H 1.7 41 * Maximum peak inrush amps approximately 1.4 x R.M.S. value shown. Note: Solenoids are designed to function continuously at 1% of rated voltage. DGC5-6 Installation Dimensions shown in millimeters (inches) T tank port 29,5 (1.16) 53,1 (2.9) 13, (5.12) 94,5 (3.72) 77, (3.3) 11,2 (.44) R 7,14 (.281) Dia. - 7,9 (.31) deep 2 holes for rest pins. Pilot valve drain port Y (see drain note on previous page). Torque 4 solenoid valve mounting screws 4,5 to 6, Nm (4 to 53 lb in). Electrical conduit connection 1 / 2 NPTF thread (both ends). 31 31 96,8 (3.81) 92, (3.62) P inlet port Port A Port B Note: When solenoid a is energized, control is by integral adjustment. When solenoid a is de-energized the valve is vented. External pilot pressure port X 14,3 (.562) Dia. thru 6 holes for mounting. Jam nut 5, (1.97) fully extended Pressure adj. control (use 7,92 (.312) hex key) W models - 155,7 (6.13) WL models - 167,8 (6.81) 132,6 (5.22) Sol. a 168,9 (6.65) AC models 182,9 (7.2) DC models 38, (1.5) AC models, 52, (2.5) DC models clearance to remove solenoid coil Pressure gauge connection.4375-2 UNF-2B thd. DGC5-6 Nameplate 35,1 (1.38) DG valve mounting surface DG4V-3-OBL-M-W-*-6 Pilot Valve 25, (1.) 5, (2.) Sol. a 114,3 (4.5) 62, (2.44) 69,8 (2.75) 88,1 (3.47) 152,4 (6.) DGC5-6 Mounting Surface (seals furnished) 36,6 (1.44) (.25) D (.25) 2 rest pins (see subplate for locations).

Performance Curves Nominal Override Characteristics DGC*-6 Models Flow USgpm 1 2 3 4 5 6 Vent Pressure Vs. Flow DGC*-6 Models Flow USgpm 1 2 3 4 5 6 13,8 2 System Pressure bar 27 173 138 114 69 3 25 2 15 1 System Pressure psi 35 5 Min. Adj. Press. 38 75 114 152 19 228 Flow l/min DGC*-H6 Models Flow USgpm 15 3 45 6 75 9 bar psi 27 3 173 25 System Pressure bar 11, 8,3 5,5 2,8 6 High Vent 6 Low Vent 38 76 114 152 19 228 Flow l/min 16 12 8 4 System Pressure psi DGC*-H6 Models Press. Press. bar Flow USgpm psi 15 3 45 6 75 9 55 8 44 64 138 2 33 H6 High Vent 48 114 15 22 32 69 1 35 Min. Adj. Press. 57 114 171 228 285 Flow l/min 5 342 11 57 114 171 228 285 Flow l/min 16 342

Pressure Sequence Module Model Code 1 2 3 4 5 1 Sequence Module 2 Module Size 6-3 / 4 inch 3 Maximum Adjustable Pressure X - 2 bar (3 psi) Y - 4 bar (6 psi) Z - 8,6 bar (125 psi) A - 17 bar (25 psi) B - 35 bar (5 psi) D - 7 bar (1 psi) F - 14 bar (2 psi) 4 Module Type 2 - Directly operated, drained to Y port. 5 Design Number Subject to change. Installation dimensions remain as shown for designs 5 through 59. General Data Vickers sequence modular hydrocushion type pressure control valves are used to control sequencing of oil flow in hydraulic systems. Control is initiated by a pressure rise which is sensed internally (directly). The valves provide a wiring cavity located in the DG4V pilot valve. A ground terminal is provided as shown. Application Pressure Setting Must be at least 17 bar (25 psi) lower than the system relief valve setting. Pressure Adjustment Adjust pressure by loosening jam nut and turning adjusting screw. Clockwise rotation increases pressure; counterclockwise rotation decreases pressure. Maximum Adjustable Pressures See model code above. Pressures are maximum controllable and each model selected should be well within the range given to afford fine increments of adjustment. Ratings Flow: 227 l/min (6 USgpm) Pressure: 21 bar (3 psi) Drain Drain must be piped directly to tank through a surge free line to ensure that there is no back pressure at the valve drain port Y. Transient pressure must be avoided. Any pressure at the drain port adds to the pressure setting of the valve. Weight DGR-6....... 12,7 kg (28 lbs.) Pressure Sequence Graphical Symbol Vent Gage X P T Y B A

DGR-6 Pressure Sequence Module Installation Dimensions shown in millimeters (inches) T Tank port 14,3 (.562) Dia. thru 6 holes for mounting module with valve 13, (5.12) 94,5 (3.72) 53,1 (2.9) 7,14 (.281) Dia. - 7,9 (.31) deep, 2 holes for valve rest pins 65,5 (2.58) 11,2 (.44) R P Pressure port Y Pilot valve drain port and module drain port - (see drain port note on previous page) 35,8 (1.41) 71,4 (2.81) 14,2 (.56) hex 96,8 71,4 (3.81) (2.81) 92, 46, (3.62) (1.81) 35,8 (1.41) External pilot pressure port X 29,5 (1.16) 77, (3.3) Cyl. port B Cyl. port A DG Valve mounting surface Primary pressure gauge connection.4375-2 UNF-2B thd. Jam nut Secondary pressure gauge connection.4375-2 UNF-2B thd. 16,7 (4.2) 99,1 (3.9) 57,1 (2.25) 114,3 (4.5) Pressure adjusting screw 152,4 (6.) 22,3 (.88) 261,9 (1.31) 292,9 fully extended (11.53) 54,6 (2.15) 35,8 (1.41) 71,4 (2.81) (.25) D 5,8 (2.) 88,9 (3.5) (.25) DGR-6 mounting surface (seals furnished) 2 rest pins (see subplate for location)

Pressure Reducing Module Model Code 1 2 3 4 5 6 7 8 1 Pressure Reducing Valve X - Direct operated 2 High Flow Capacity Blank - Omit for B and F models. H - 265 l/min (7 USgpm). 3 Module Size 6-3 / 4 inch 4 Maximum Adjustable Pressure 1-7 bar (1 psi) 2-14 bar (2 psi) 3-2 bar (29 psi) General Data The operation of these pressure reducing modules is such that reduced outlet pressure is maintained constant, regardless of variation of inlet pressure above the selected pressure setting. Application (see installation drawing on page 13) [1.] Pressure Setting Adjustment of reduced outlet pressure is accomplished by loosening jam nut and turning pressure adjustment control. Clockwise rotation increases pressure; counterclockwise rotation decreases pressure. Control adjustment has stops for minimum and maximum pressure. Adjustable Pressure Maximum: 1 7 bar (1 psi) 2 14 bar (2 psi) 3 175 bar (25 psi) [2.] Remote Pressure Adjustment Reduced pressure may be adjusted remotely by connecting remote control connection to the pressure inlet port of a CGR-2-*-3* valve or C-175-*-2* valve. 5 Maximum Flow Capacity Blank - Omit for high flow H models. B - 57 l/min (15 USgpm), 5,5 bar (8 psi) minimum adjustable pressure ( 3B configurations not available). F - 114 l/min (3 USgpm), 14 bar (2 psi) minimum adjustable pressure. 6 Drain Options Blank - Omit for standard ( Y port drain) E - Externally drained through cover. L - Internally drained to B port. Pressure setting of the main valve must be higher than that of the remote control. [3.] Drain Y port must be piped directly to tank through a surge free line so there s no back pressure at the valve drain port. Transient pressure must not exceed,35 bar (5 psi). Port B (Type L) and cover drain (Type E) may be subjected to pressure up to 21 bar (3 psi); this pressure is additive to the reduced pressure setting. [4.] Contact your local distributor or Vickers representative if maximum inlet pressure is needed with minimum rated reduced pressure. Pressure Drop Through the module at 114 l/min (3 USgpm) and 21 cst (1 SUS) is 1,5 bar (22 psi). 7 Design Number Subject to change. Installation dimensions remain as shown for designs 6 through 69. 8 Special Feature Suffix S19 - Internally drained to tank. Ratings Maximum flow capacity (see note [4]): DGX-6-*-B* (5,5 bar (8 psi) min. adj. press..... 57 l/min (15 USgpm) DGX-6-*F*-6* (14 bar (2 psi) min. adj. press..... 114 l/min (3 USgpm) DGX-H6-**-6* 265 l/min (7 USgpm) Max. inlet pressure: 21 bar (3 psi) Drain Leakage Typical DGX-*-6 drain leakage values at no thru flow condition are shown below for various differential pressures (subtract outlet pressure from inlet pressure). Diff. Press. ( P) Drain Leakage 35 bar (5 psi)........ 74 to 1,7 l/min (45-65 in 3 /min) 1 bar (15 psi)...... 9 to 1,31 l/min (55-8 in 3 /min) 17 bar (25 psi)...... 1,15 to 1,64 l/min (7-1 in 3 /min) Weight DGX-6....... 11,8 kg (26 lbs.)

Pressure Reducing Graphical Symbol Model No. Description DGX-6-*-6* Operated from P and reducing in P. Drained to Y port. Gage Vent Gage X P T Y B A DGX-6-*L-6* Operated from P and reducing in P. Drained to B port reduced pressure on A port only. Gage Vent Gage X P T Y B A DGX-6-*E-6* Operated from P and reducing in P. Drained externally thru cover connection. Gage Vent Gage X P T Y B A External drain Outlet Pressure vs. Flow Characteristics Minimum Adjustable Pressure vs. Flow Reduced pressure - bar 21 17 14 1 7 35 6-2B Flow USgpm 1 2 3 4 5 6 6-3F H6-3 6-2F H6-2 6-1B 6-1F H6-1 7 3 25 2 15 1 5 Reduced pressure - psi Reduced pressure - bar 41,4 34,5 27,6 2,7 13,8 6,9 Flow USgpm 1 2 3 4 5 6 H6 6-*B 6-*F (See drain note 3) 7 6 5 4 3 2 1 Reduced pressure - psi 38 75 114 152 19 228 Flow l/min 266 38 75 114 152 19 228 Flow l/min 266 Note: These charts are based on the inlet pressure being at least 1,3 bar (15 psi) higher than the outlet reduced pressure.

DGX-*6 Pressure Reducing Module Installation Dimensions shown in millimeters (inches) T tank port 14,3 (.562) Dia. thru 6 holes for mounting module with valve 21,3 (.84) 13, (5.12) 94,5 (3.72) 53,1 (2.9) 21,3 (.84) P pressure port 1 / 16 NPTF - Remove plug for standard module [3.] Y Pilot valve drain port and module drain port - (see drain port note on page 11). [2.] Remote control connection.5625-18 UNF-2B thd. 71,4 (2.81) 46, (1.81) External pilot pressure port X 29,5 (1.16) 7,14 (.281) Dia. - 7,9 (.31) deep, 2 holes for valve rest pins 77, (3.3) Cyl. port A 42,2 (1.66) 93,7 (3.69) Cyl. port B (type L module internally drained to this port). 92, (3.62) 96,8 (3.81) External drain thru cover connection.5625-18 UNF-2B thd. Connection available on type E module only (see drain note on page 11). DG Valve mounting surface 244,8 (9.64) 152,4 (6.) [1.] Pressure adjustment 59,4 (2.34) Jam nut 177, (6.95) fully extended 114,3 (4.5) 71,4 (2.81) 5,8 (2.) 53,7 (2.31) 53,8 (2.12) 88,9 (3.5) 15, (.59) Secondary pressure gauge connection.4375-2 UNF-2B thd. Primary pressure gauge connection.4375-2 UNF-2B thd. 14,1 (4.1) 118,8 (4.4) 22,3 (.88) 2 Rest pins (see subplate for location) (.25) D (.25) DGX-6 Mounting surface (seals furnished)

Flow Regulator Module Model Code 1 1 2 Flow Control Module 2 Module Size 6-3 / 4 inch 5 Design Number Subject to change. Installation dimensions remain as shown for designs 5 through 59. 3 General Data These flow regulator modules have restriction checks in both cylinder ports. Flow to the directional valve passes through the module; flow out of the cylinder port of the directional valve passes free flow over restriction checks; return flow must pass over one of the restriction checks. As a result, the actuator device is controlled in a meter-out mode in each direction. Application Drain Pilot valve drain line Y must be piped directly to tank through a surge free line so that there will be no back pressure at this drain. Transient pressure must not exceed,35 bar ( 5 psi). Pressure Drop Through the module at 132 l/min (35 USgpm) and 21 cst (1 SUS) is 11,4 bar (165 psi) with adjusting screws completely in (total drop P to A plus B to T). Ratings Max. inlet pressure: 21 bar (3 psi) Max. flow (rec.): 227 l/min (6 USgpm) Weight DGFN-6-5*..... 6,4 kg (14 lbs.) Flow Regulator Graphical Symbol X P T Y B A DGFN-6 Flow Regulator Module Installation Dimensions shown in millimeters (inches) 21,3 (.84) T Tank port 11,2 (.44) R. 38,1 (1.5) D. 94,5 (3.72) 13, (5.12) 53,1 (2.9) 173, (6.81) 7,14 (.281) Dia. - 7,9 (.31) deep, 2 holes for valve rest pins P Pressure inlet port 21 bar (3 psi) max. Pilot valve drain port Y (see drain note above) 38,1 (1.5) D. 96,8 (3.81) 96,8 (3.81) 25,4 (1.) fully extended 29,5 (1.16) 77, Ext. pilot (3.3) pressure port X Cyl. port A Cyl. port B Locknut 12,7 (.5) hex. both ends. 152,4 (6.) 25,4 (1.) fully extended 1,4 (.41) 46, (1.81) 14,3 (.562) Dia. thru 6 holes for mounting module with valve DG valve mounting surface 57,1 (2.25) 115,8 (4.56) 114,3 (4.5) 44,4 (1.75) 88,9 (3.5) Adjusting screws both ends. (.3125-24 UNF thd. Use 4, (.16) hex. key). Adjust by backing off locknuts and turning adjusting screws OUT to decrease rate of flow and IN to increase rate of flow. 2 Rest pins (see subplate for location) DGFN-6 Mounting surface (seals furnished) (.25) D. (.25)

Pilot Operated Check Module Model Code 1 2 3 4 5 6 7 8 9 1 Pilot Operated Check Module X - Direct operated 2 Module Size 6-3 / 4 inch 3 D Decompression Feature Blank if not required. 5 Check Valve Cracking Pressure Blank for standard 2 bar (3 psi) cracking pressure. Other cracking pressures are available upon request. 6 D Decompression Feature Blank if not required. 7 Check in Cyl. B Port 8 Check Valve Cracking Pressure Blank for standard 2 bar (3 psi) cracking pressure. Other cracking pressures are available upon request. 9 Design Number Subject to change. Installation dimensions remain as shown for designs 5 through 59. 4 Check in Cyl. A Port General Data These modules are available with a check valve in either one or both cylinder ports. They are arranged for free flow out of the DG*S-8 directional valve. For return flow, one check can be unseated by a common striker piston mounted co-axially between the two checks; this happens when internal pressure on one side is sufficient to cause the striker piston to open the check valve on the opposite side. In a neutral condition (with cylinder ports open to tank at the directional valve) compression springs will seat the checks and the machine actuator will be held stationary. A small decompression poppet which opens before the main check valve is available. Add the letter D as shown in the model code. Application Directional Valve Directional valve types with cylinder ports open to tank in center position are recommended. (Spool types, 6, 9 and 33). The DGPC module is not usable with pressure centered or DG18S-8 air operated valves. Drain Drain connection Y must be piped directly to tank through a surge free line so there will be no back pressure at the valve drain port. Transient pressure must not exceed,35 bar (5 psi). Note When using pilot operated check modules, it is desirable to include a flow control module (DGFN-6) to impose a greater back pressure on the cylinder than the load generates to avoid chattering. Pressure Drop Through the module at 132 l/min (35 USgpm) and 21 cst (1 SUS) is 7 bar (1 psi) not including the check cracking pressure (total drop P to A plus B to T). Ratings Max. flow (rec.) 227 l/min (6 USgpm) Max. inlet pres. 21 bar (3 psi) Opening ratios: Decompression poppet 34.1:1 Check 2.2:1 Cracking pressures: Each check (standard) 2 bar (3 psi) (Other cracking pressures are available on request.) Weight DGPC-6...... 13,2 kg (29 lbs.)

DGPC-6 Pilot Operated Check Installation Dimensions shown in millimeters (inches) T Tank port 21,3 (.84) P Pressure inlet port 53,1 (2.9) 94,5 (3.72) 7,14 (.281) Dia. - 7,9 (.31) deep, 2 holes for valve rest pins Pilot valve drain port Y (see drain note on previous page) 11,2 21,3 (.44) R. (.84) 71,4 (2.81) Cyl. port A Cyl. port B 71,4 (2.81) 96,8 (3.81) 92, (3.62) Ext. pilot pressure port X 29,5 (1.16) 77, (3.3) 13, (5.12) 68,8 (2.71) 11,2 (.44) 14,3 (.562) Dia. thru 6 holes for mounting module with valve DG Valve mounting surface 114,3 (4.5) 71,4 (2.81) 71,4 (2.81) 11,6 (4.) 17,3 (.68) 152,4 (6.) 268,2 (1.56) 2 Rest pins (see subplate for location) 57,9 (2.28) 17,3 (.68) (.25) DGPC-6 Mounting surface (seals furnished) (.25) D

DGSM-8 Single Station Subplates & Mountings General Data Before beginning to assemble individual modular valves, mating surfaces must be undamaged and completely clean in order to ensure a perfect seal. Single Station Subplates DGSM single station subplates are designed for individual mounting of one modular valve system. Mounting Pad When a subplate is not used, a machined pad (as indicated by subplate shaded area) must be provided for mounting. Pad must be flat within,13 mm (.5 inch) and smooth within 1,6 µm (63 microinch). Mounting Bolts for Modular Valves Mounting the various combinations of modular valves in vertical assemblies will require bolt kits of different lengths. These lengths can be determined from the Bolt Length/Kits Selection Chart (below) which indicates the height of the various modules. Mounting bolts provided by the customer should be SAE grade 7 or better. Bolt Length Selection Chart - Bolt Kits for Modular Valves Bolt Kits for Modular Mounting A range of bolt kits is available for mounting the various modules, normally topped with a DG5S-8, DG3S-8 or DG17S-8 directional control valve. As the modules are of varying height, it is necessary to calculate the height of the stack and then add 2,66mm (.81 in.) for thread engagement. The Bolt Length/Kits Selection Chart (below) contains a list of all possible bolt lengths for the modular system to NFPA-D8 (ISO-441-8) interface. Note: This table serves as a guide in selecting the proper mounting bolt length for various combinations of modules. After the circuit is developed and the components to be stacked are predetermined, add the required lengths plus a 2,6 mm (.81 inch) thread engagement for the subplate or manifold. Select the proper inch thread bolt and order by the bolt kit number. All bolt kits include six (6) socket head screws and six (6) lockwashers 4,4 mm (.17 inch) thick. Using two (2) center bolts is optional. All six (6) bolts are recommended for pressure ranges of 14 bar (2 psi) to 21 bar (3 psi) for maximum seal life. DG5S-8 FN, R, X C PC Subplate Bolt Length Length Required (inch)* Bolt Kit Model No. 1.86* 3.5 2.75 4..64* 1 / 2-13 UNC thd. 1 1 1 5-1 / 4 BK255693 1 1 1 6 BK255691 1 1 1 6-1 / 2 BK255692 1 1 1 1 8-3 / 4 BK255668 1 1 1 1 9-1 / 4 BK255671 1 2 1 9-1 / 2 BK25567 1 1 1 1 1 BK255669 1 2 1 1 12-1 / 4 BK255676 1 1 1 1 1 12-3 / 4 BK255677 1 3 1 13 BK255678 1 2 1 1 13-1 / 2 BK255679 Recommended bolt torque 79 Nm (7 lb. in.). * Assumes use of 4,4 mm (.17 inch) thick lockwasher.

Ordering Procedure Valves, subplates and mounting bolts must be ordered separately. Example: One (1) DG5S-8-C-M-W-B-2* Valve One (1) DGX-H6-2-6 Reducing module One (1) DGSM-8-1-T12 Subplate One (1) BK255691 Inch bolt kit Example for ordering: (1) DG5S-8 Valve............... 42,9 mm (1.69 in.) (1) DGFN-6 Module............ 88,9 mm (3.5 in.) (1) DGPC-6 Module............ 11,6 mm (4. in.) + Manifold thread engagement.... 2,6 mm (.81 in.) Total bolt length................. 254, mm (1. in.) Order bolt kit number BK225669. Mounting Subplates Model No. E Thd. Tubing O.D. F Dia. Weight (approx.) DGSM-8-1-T12 1.625-12 UN.75 23,8 (.937) 5. kg (11 lbs) DGSM-8-1-T16 1.3125-12 UN 1. 24,6 (.969) 5. kg (11 lbs) Additional Subplates Model No. Tubing O.D. (thd. size) System Connections DGSME-8-1-T12.75 O.D. (1.625-12 UN thd.) Side DGSME-8-1-T16 1. O.D. (1.3125-12 UN thd.) Side DGSM-8-1-T2 1.25 O.D. (1.625-12 UN thd.) Rear Mounting Subplate DGSM-8-1-T12/16 Dimensions in millimeters (inch) T Tank port.5-13 UNC-2B thd. 6 holes (subplate with M12 x 1,75 metric screw holes avail. on special order). 1,3 (.46) Dia. 4 holes for mounting. P Pressure inlet connection 7,14 (.281) Dia. - 7,9 (.31) 23,2 deep, 2 holes for valve rest pins (8.) 112,7 Y Pilot valve drain connection (for externally (4.44) drained pilot valves). Drain connection for DGR 94,5 and standard DGX valves. (3.72) 77, (3.3) 29,5 (1.16) 114,3 (4.5) 92, (3.62) 74,6 (2.94) 19, (.75) 96,8 (3.81) 73, (2.87) 25,4 (1.) 17,5 (.69) X External pilot pressure conn. 12,9 (.58) dia. thru.5625-18 UNF-2B thd. for.375 O.D. tubing from rear - 2 holes X & Y. 1,8 (3.97) 53,1 (2.9) 13, (5.12) 181, (7.12) 17,5 (.69) 35, (1.38) 11,2 (.44) R. Cyl. connection B ( F dia., see above) thru 4 holes (system ports) E SAE str. thd. ports (from rear) 4 holes (system connection).

Application Data Fluid Cleanliness Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity, and inclusion of air. Essential information on the correct methods for treating hydraulic fluid is included in Vickers publication 561 Vickers Guide to Systemic Contamination Control available from your local Vickers distributor or by contacting Vickers, Incorporated. Recommendations on filtration and the selection of products to control fluid condition are included in 561. Recommended cleanliness levels, using petroleum oil under common conditions, are based on the highest fluid pressure levels in the system and are coded in the chart below. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these cleanliness codes. See Vickers publication 561 for exact details. System Pressure Level bar (psi) Vickers products, as any components, will operate with apparent satisfaction in fluids with higher cleanliness codes than those described. Other manufacturers will often recommend levels above those specified. Experience has shown, however, that life of any hydraulic component is shortened in fluids with higher cleanliness codes than those listed below. These codes have been proven to provide a long, trouble-free service life for the products shown, regardless of the manufacturer. Product <7 ( <1) 7-21 (1-3) 21+ ( 3+) Vane Pumps Fixed 2/18/15 19/17/14 18/16/13 Vane Pumps Variable 18/16/14 17/15/13 Piston Pumps Fixed 19/17/15 18/16/14 17/15/13 Piston Pumps Variable 18/16/14 17/15/13 16/14/12 Directional Valves 2/18/15 2/18/15 19/17/14 Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14 CMX Valves 18/16/14 18/16/14 17/15/13 Servo Valves 16/14/11 16/14/11 15/13/1 Proportional Valves 17/15/12 17/15/12 15/13/11 Cylinders 2/18/15 2/18/15 2/18/15 Vane Motors 2/18/15 19/17/14 18/16/13 Axial Piston Motors 19/17/14 18/16/13 17/15/12 Radial Piston Motors 2/18/14 19/17/13 18/16/13 Fluids and Seals Flourocarbon seals are standard and are suitable for use with phosphate ester type fluids or their blends, water glycol, water-in-oil emulsion fluids and petroleum oil. Refer to data sheet I-286-S for hydraulic fluid and temperature recommendations.

Service Drawings Dwg No. DGC-*6 Pressure Relief Module I-3381-S DGC5-6A Solenoid Controlled Relief Module I-3425-S DGR-6 Pressure Sequence Module I-3649-S DGX-*6 Pressure Reducing Module I-365-S DGPC-6 Pilot Operated Check Module I-3397-S DGFN-6 Flow Regulator Module I-3384-S Eaton Hydraulics 15151 Highway 5 Eden Prairie, MN 55344 Telephone: 612 937-7254 Fax: 612 937-713 www.eatonhydraulics.com 46 New Lane, Havant Hampshire PO9 2NB England Telephone: (44) 17-548-6451 Fax: (44) 17-548-711 Form No. - Copyright Eaton Corporation, All rights reserved. Printed in U.S.A