See inside for respirable dust samplers listed in OSHA's final rule.

Similar documents
Parallel Particle Impactors New Personal Samplers for Accurate Assessment of Worker Exposure to Respirable or Thoracic Dust

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

UNDERSTANDING THE OSHA SILICA STANDARD FOR CONSTRUCTION REAL-TIME MONITORING FOR RESPIRABLE SILICA DUST

UNDERSTANDING THE OSHA SILICA STANDARD FOR CONSTRUCTION REAL-TIME MONITORING FOR RESPIRABLE SILICA DUST

OSHA S NEW FINAL RULE ON CRYSTALLINE SILICA: WHAT YOU NEED TO KNOW 29 CFR

Mass Flowmeters. Mass Flowmeters for Gases

Automatic Isokinetic Sampler. ST5 Evo

AIR FLOW CALIBRATORS Single Sensor Designs

SILICA EXPOSURE MEASUREMENT IN REAL-TIME FOR CONSTRUCTION

Dust Measurement & SIBATA Products. Sibata Scientific Technology Ltd.

UNDERSTANDING, ACCELERATED

. October 3, Kelly Guinsler Manager of Quality Services (704)

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Industrial Hygiene Sampling. Husqvarna Construction Products

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

QUANTIFIT....the gold standard in respirator fit testing. Product Information Brochure

Optical Dissolved Oxygen Meter

Additel 761 Automated Pressure Calibrators Selection Guide

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Pneumatic high-pressure controller Model CPC7000

Automatic Isokinetic Sampler. ST5 Evo

Columbus Instruments

130 SSP Soluble Salt Profiler

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

4.0 Audit Procedure for the MetOne SASS Speciation Sampler

EVM Series: Frequently Asked Questions

Met One E-BAM Particulate Monitor

QRAE II Quick Reference Covers Diffusion & Pump Models with Firmware Version 3.12 and higher

Biconic Connectors and Accessories

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

Revision: 23 March 2008 (nk)

Optical Dissolved Oxygen Meter

OSHA Final Rule: Occupational Exposure to Respirable Crystalline Silica

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

Tel: FAX: Risk Assessment for Exposure to Respirable Dusts Generated from the Use of Chalks and Pastels

GUIDELINES FOR MONITORING EXPOSURE

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Pneumatic high-pressure controller Model CPC7000

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

PHOENIX L300i Best-in-class Helium Leak Detectors

Industrial pressure controller Model CPC4000

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Additel 761 Automated Pressure Calibrators

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

FTC130 Transmitter. Operating Manual

Precision digital pressure gauge Model CPG1000

Application Note AN-107

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Expert Hydrostatic Level Transmitters

PARTICULATES NOT OTHERWISE REGULATED, RESPIRABLE 0600

Dräger RZ 7000 Test Equipment

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

OXYBABY - MOBILE HAND HELD GAS ANALYSER

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Gas-Detection Instruments

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Additel 761 Automated Pressure Calibrators

HPFM GEN3 - High Pressure Flow Meter

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

Dräger RZ 7000 Test Equipment

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Your local gas generation partner. Precision series Modular gas generation solution for GC.

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

TI 176B Flow Rate Audit Calculations

Controlling Silica Dust Exposure in Construction: Real World Case Studies in Exposure Assessment and Hazard Control

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Advantage 4000 Abrasi-Blast Respirator

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

Oxidation Stability of Gasoline and Aviation Fuels

Implementing the New OSHA Respirable Crystalline Silica Standard in General Industry

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

About us. Try us to trace your network!

INSTALLATION & MAINTENANCE INSTRUCTIONS

NEW ATEX VERSION. The features of the OptimAir 3000 PAPR will take your breath away.

ADT 761 Automated Pressure Calibrator

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Advanced Test Equipment Rentals ATEC (2832)

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

3M Electrial Markets Division EMS. Electronic Marker System

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

UNIVERSAL TUBE HOLDER SYSTEM

Additel 780 Series Pressure Controller

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

Additel 780 Series Pressure Controller

OSHA Silica Regulations: Impact & Best Practices

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

VACUUM REGULATORS CONTENTS

An Evaluation of the Pullman-Ermator S26 and S13 Vacuums with a Newly Patented Dust Hood

Transcription:

OSHA Aligns with Global Sampling Criteria in the Final Rule on Respirable Crystalline Silica! On March 25, 2016, U.S. OSHA published its new silica rule to take effect on June 23, 2016. This effective date was revised to implement deadlines of September 23, 2017 for the construction industry and June 23, 2018 for general industry and maritime. Following is a brief summary of this significant regulation. Sets a lower (50 μg/m 3 ) permissible exposure limit (PEL) for all industries covered by the regulation and abandons the previous silica PEL formula Adopts the more conservative ISO 7708/CEN criteria of a 4-μm 50% cut-point for respirable dust samplers, aligning OSHA with NIOSH, ACGIH, and most other global occupational hygiene organizations Notes that any sampler conforming to ISO 7708/CEN criteria can be used, including specific examples of the SKC samplers listed in this brochure See the new rule in its entirety at www.osha.gov/silica/. SKC is proud of its contributions to this important movement forward in protecting worker health. See inside for respirable dust samplers listed in OSHA's final rule. Aluminum Cyclone GS-3 Cyclone PPI Impaction-based Samplers

SKC Respirable Dust Samplers Cyclones SKC Respirable Dust Cyclones Meet New OSHA Criteria SKC offers two respirable dust cyclones to meet the performance criteria set forth by OSHA in its final silica rule (final rule pages 16439, 16441, and 16453). Both cyclones are designed for superior performance compared to other cyclones on the market. SKC Aluminum Cyclone meets ISO 7708/CEN criteria at a flow rate of 2.5 L/min. Performance data relative to the ISO/CEN standard adopted by OSHA, ACGIH, and other international agencies can be found in the Journal of Aerosol Science. See Reference 1 at bottom left. SKC GS-3 Cyclone meets ISO 7708/CEN criteria at a flow rate of 2.75 L/min. Performance data relative to the ISO/CEN criteria is available in the Journal of Aerosol Science. See Reference 2 at bottom left. Respirable Dust Cyclone Features/Advantages Conductive aluminum or plastic construction eliminates electrostatic effects Used with an open-face 3-piece cassette for even particle deposition on the filter Available in 25 or 37 mm Aluminum Cyclone has an easy-to-use calibration adapter accessory Flow Rate: Aluminum Cyclone: 2.5 L/min GS-3 Cyclone: 2.75 L/min Filters/Cassettes Require a 37-mm, 3-piece cassette loaded with 5.0-μm PVC filter Recommended Sample Pump and Calibrator Programmable AirChek with touch screen operation See page 6. chek-mate Calibrator References 1 Harper, M., et al., Calibration of the SKC, Inc. Aluminum Cyclone Jnl. of Aer. Sci., Vol. 29, (Suppl. 1), 1998, pp. S347-S348 2 Gautam, M. and Sreenath, A., Performance of a Respirable Multi-inlet Cyclone, Jnl. of Aer. Sci., Vol. 28, No. 7, 1997, pp. 1265-1281 (dx.doi.org/10.1016/s0021-8502(96)00472-7) GS-3 Cyclone features three inlet slits that eliminate the ambient wind speed and orientation bias found with the 10-mm nylon cyclone Ordering Sampler Aluminum Cyclone with grit pot, requires a 3-piece cassette GS-3 Cyclone with bowl adapter, cassette adapter, and grit pot, requires a 3-piece cassette 25 mm 37 mm 25 mm 37 mm 225-01-01 225-01-02 225-103 225-100 Sampling Media PVC Filters, GLA-5000, 37 mm, 5.0-μm pore size, includes support pads, pk/100 225-5-37-P Cassette Blanks, SureSeal certified leak-free, 37 mm, 3-piece, clear styrene, pk/50; require SureSeal Cassette Opener accessory 225-3050LF Preloaded PVC Filters, GLA-5000, 37 mm, 5.0-μm pore size with supports, preloaded into a 3-piece clear styrene cassette, banded, pk/50; require SureSeal Cassette Opener accessory 225-803 Preweighed PVC Filters in Cassettes, GLA-5000, 37 mm, 5.0-μm pore size filter with supports, preweighed, 5 decimal; pk/12 225-8208 preloaded into a 3-piece clear styrene cassette, banded pk/100 225-8209 Accessories Calibration Adapter for Aluminum Cyclone, 25/37 mm 225-01-03 Standard Calibration Jar for GS-3 Cyclone, 25/37mm 225-111 Filter Cassette/Cyclone Holder, 25/37 mm 225-1 SureSeal Cassette Opener, 25/37 mm 225-13-5A Visit www.skcinc.com and search on "cyclone" for more information. 2 SKC Ltd. www.skcltd.com SKC South Africa www.skcsouthafrica.co.za

SM-4000 Personal Silica Monitor Complementary Monitoring for Silica Mitigation Direct-reading Silica Monitor Silica Monitor SM-4000 is a direct-reading personal dust monitor optimized for the measurement of silica levels specified in the OSHA final silica rule. Calibrated to a known amount of silica dust, SM-4000 provides direct readings for determination of peak silica concentrations for mitigation and lower TWAs. The SM-4000 internal pump and gravimetric filter cassette (directly behind the sensor) provide for concurrent collection of a gravimetric sample for silica analysis and cross-calibration. Use the SM-4000 for: Perimeter monitoring of regulated areas with user-set alarms Evaluation of controls and worker activities Recording time history of dust levels Filter sampling for lab analysis Task monitoring Selecting PPE SM-4000 Features/Advantages Low sensing range down to 1 μg/m 3 High precision of ± 3 μg/m 3 The SM-4000 looks like a HAZ-DUST IV but is uniquely optimized for measuring silica at the new PEL. Readings display in μg/m 3 no conversions needed Comes standard with GS-3 Cyclone that conforms to ISO 7708/CEN criteria (see page 2 for details) Concurrent filter sampling option for lab analysis and/or cross-calibration to displayed results Gravimetric filter cassette located directly behind the sensor for maximum particle deposition Internal pump samples at 2.75 L/min (user adjustable) Sensor and filter cassette clips directly in the breathing zone Datalogging DustComm Software allows for graphical analysis and comprehensive time history reporting Ordering SM-4000 Personal Silica Monitor Kit includes SM-4000 Monitor, GS-3 respirable cyclone, 37-mm in-line filter cassette, serial computer cable, serial to USB adapter cable, battery charger, HAZ-DUST zeroing filter, media CD with instruction manual and Dust- Comm Pro Software (compatible with Windows XP, 7, 8, and 10), and carry case 110-240V 770-700 Sensor: Light scattering Flow Rate: 2.75 L/min (user adjustable) Sensing Range: 1 to 20,000 μg/m 3 (0.001 to 20 mg/m 3 ) Precision: ± 3 μg/m 3 (0.003 mg/m 3 ) Display: Concentration in μg/m 3, TWA, STEL, MIN, and MAX Accuracy: ± 10% to filter gravimetric SAE fine test dust Gravimetric Filter Sampling Requirements: 37-mm PVC filter for the supplied 37-mm in-line cassette (25-mm filter and cassette options are available) Accessories Calibration Standard for Monitor, for verifying span and optical sensor performance 770-710 Calibration Jar, for calibrating and setting pump flow when using a respirable cyclone 225-112 Cleaning Kit, for cleaning SM-4000 Monitor 770-305 Replacement Battery Pack 770-4105 Requires calibration with equipment sold separately. Contact your SKC Representative for more information. SKC Asia www.skc-asia.com SKC Inc. www.skcinc.com 3

SKC Respirable Dust Samplers New Impactors SKC Parallel Particle Impactors (PPIs) Listed in the OSHA Silica Rule PPI Features/Advantages Collection efficiency precisely matches ISO 7708/CEN criteria adopted in the OSHA final silica rule* Two sampler configurations are available Reusable conductive aluminum Disposable anti-static plastic, designed for one-time use Disposable PPI Sampler options Preloaded with filter preweighed by SKC or not preweighed Empty for filter loading by a laboratory or the user All Disposable PPI Samplers are preloaded with pre-oiled impaction substrates in the inlet section Performance published in Journal of Physics and referenced in the OSHA final silica rule Calibration adapter for Disposable PPI eliminates need for a calibration jar No tipping hazard! Invert PPI without large particles invalidating the sample Flow Rate: 2, 4, or 8 L/min (4-μm 50% cutpoint); model dependent, to meet ISO/CEN criteria in OSHA final silica rule* Principle of Operation: Impaction separation of particles according to aerodynamic diameter Sampling Media: 37-mm PVC filter/support Dimensions (Plastic and Aluminum): Height (clip to exhaust): 4.25 in (10.8 cm) Diameter: 1.8 in (4.6 cm) Depth: 1.2 in (3 cm) Weight: Plastic Aluminum 1.1 oz (31.2 gm) 3.3 oz (93.6 gm) PPI Model Flow Rate Fraction Application 2 L/min Respirable 8-hour TWA sampling 4 L/min Respirable TWA sampling for 4 hours 8 L/min Respirable Short-term sampling The PPI 4-in-1 Advantage Inlet Plate Impaction Substrates (4) * PPI performance data from a peer-reviewed journal article and part of the OSHA docket used to develop the OSHA final silica rule References Trakumas, S. and Salter, E., Parallel Particle Impactor Novel Size-selective Particle Sampler for Accurate Fractioning of Inhalable Particles, Journal of Physics: Conference Series, 151 012060, http://doi.org/fbccwk SKC Sampling Solutions for Respirable Crystalline Silica, http://www.skcinc.com/pdf/safetysolutions/1881.pdf Collection Filter Base Plate with Exhaust The patented PPI features four uniquely sized inlets (mini impactors), each achieving a specific cut-point that matches its corresponding part of the ISO 7708/ CEN efficiency curve. Dust on the final filter closely matches the entire curve. Comparison of PPI Samplers performance with ISO 7708/CEN respirable criteria U.S. Patent No. 7,073,402 4 SKC Ltd. www.skcltd.com SKC South Africa www.skcsouthafrica.co.za

Parallel Particle Impactors (PPIs) Available in Reusable Aluminum or Disposable Plastic Reusable Aluminum PPI Samplers Select a PPI based on application (see p. 4) and order impaction substrates, filters, and supports. Reusable PPI Samplers, require substrates, filters, and supports Respirable PPI (red), 8 L/min, aluminum Respirable PPI (orange), 4 L/min, aluminum Respirable PPI (gold), 2 L/min, aluminum 225-383 225-382 225-380 Impaction Substrates for Reusable Aluminum PPI, four required for each sample Porous Plastic Discs, 3/8-inch diameter, pre-oiled, ready to use, disposable, pk/200 225-388 Filters and Supports for Reusable PPI Samplers PVC Filters, 37 mm, 5.0-μm pore size, pk/100 225-5-37 Support Pads, cellulose, 37 mm, pk/100 225-27 Stainless Steel Screen, 37 mm, wide mesh, ea 225-26 Preloaded Disposable Plastic PPI Samplers** Select a PPI based on application (see p. 4). Preloaded Disposable PPI Samplers contain four porous plastic disc impaction substrates, one 37-mm cellulose support, and one 5.0-μm PVC collection filter as noted Respirable PPI (red), 8 L/min, plastic Respirable PPI (orange), 4 L/min, plastic Respirable PPI (gold), 2 L/min, plastic * Preweighed to 5 decimals ** Designed for one-time use (not preweighed) 225-3841 225-3871 225-3851 Now available with preweighed filter! (preweighed*) 225-3841-PW 225-3871-PW 225-3851-PW New! SKC Silica Sampling Kits User-loaded Disposable Plastic PPI Samplers** Select a PPI based on application (see p. 4) and order supports and filters. User-loaded Disposable PPI Samplers contain four porous plastic disc impaction substrates, require collection filter and support; see information below and select based on application Respirable PPI (red), 8 L/min, plastic 225-384 Respirable PPI (orange), 4 L/min, plastic 225-387 Respirable PPI (gold), 2 L/min, plastic 225-385 pk/25 225-385A Filters and Supports for User-loaded PPI Samplers PVC Filters, 37 mm, 5.0-μm pore size, pk/100 225-5-37 Support Pads, cellulose, 37 mm, pk/100 225-27 Stainless Steel Screen, 37 mm, wide mesh, ea 225-26 ** Designed for one-time use Accessory Calibration Adapter, for Disposable PPI Samplers only 225-389 220-5000TC-K-S with AirChek TOUCH pump and chek-mate Calibrator shown. See p. 6 for ordering information. Compliance monitoring of airborne silica concentrations is easy with an SKC Silica Sampling Kit as your complete silica sampling toolbox. Kits include Preloaded Disposable PPI Respirable Dust Samplers, sample pump, pump charger, certified calibrator or rotameter, and calibration and sampling accessories, all in a convenient tool case. Deluxe and basic kits are available. Visit www.skcinc.com and search on "PPI" for more information. SKC Asia www.skc-asia.com SKC Inc. www.skcinc.com 5

Sample Pumps AirChek Sample Pump Intuitive Touch Screen Navigation AirChek Features/Advantages Easiest and most powerful personal pump you will ever use Real-time data at a touch Color touch screen navigation, easy programming Constant flow to 5 L/min for high dust loadings High back pressure compensation up to 50 inches of water at 2 L/min Flow fault and auto-restart Powerful Li-Ion battery for up to 20 hours at 2 L/min Corrects flow for changes in temperature and atmospheric pressure Screen lock-out feature e-cradle adds PC communication Programmable using touch screen or optional DataTrac Pro Software and PC Small and lightweight Interlocking cradles for charging and PC communication Chain up to 5 cradles 6 Flow Range: 5 ml/min to 5 L/min Power/Run Time: Li-Ion battery up to 20 hrs (2 L/min, 37-mm, 0.8-μm MCE filter) Back Pressure: Up to 50 inches water at 2 L/min Tubing: 1/4-in ID Weight: 19.4 oz (550 gm) Dimensions: 4.1 x 3.7 x 2.8 in (10.4 x 9.4 x 7.1 cm) Calibrator: SKC chek-mate; see below right Recommended for use with: Cyclones on pages 2 and 3 2 and 4 L/min PPIs on pages 4 and 5 Automatic flow fault and restart Ordering AirChek Pump with Li-Ion battery pack and screwdriver set, requires charging cradle and power supply; see Starter Kit below 220-5000TC Starter Kit includes pump as described above, Standard Charging Cradle, power supply with cord, 3 feet (0.9 meter) of Tygon tubing, and collar clip with cable tie 100-240 V 220-5000TC-S Single High Flow Pump Kit includes pump as described above, Standard Charging Cradle, power supply with cord, and filter cassette holder, in a soft-sided nylon carry case 100-240 V 220-5000TC-K 5-pack High Flow Pump Kit includes 5 pumps as described above, 4 Standard Charging Cradles, 1 e-cradle, power supply with cord, USB cable, and 5 filter cassette holders, in a Pelican carry case 100-240 V 220-5000TC-K5 Deluxe Silica Sampling Kit includes pump as described above, Standard Charging Cradle, power supply with cord, 4 feet (1.2 meters) of Tygon tubing, chek-mate Calibrator, 10 Preloaded Disposable PPIs (225-3851), and PPI calibration adapter, in a hard-sided toolbox 100-240 V 220-5000TC-K-S Basic Silica Sampling Kit with AirChek 52 pump is available. See www.skcinc.com AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. Accessories DataTrac Pro for AirChek Hardware Accessory Kit includes e-cradle, free software download, USB cable, and single power supply 877-93 Protective Pouch, nylon, with adjustable waist belt and shoulder strap, black 224-911 chek-mate Calibrator, 0.75 to 5 L/min flow range, includes 9-volt alkaline battery and NIST-traceable calibration certificate 375-07550N Rotameter, 0.4 to 5.0 L/min, 4-inch scale 320-4A5 Visit www.skcinc.com/touch.asp for more information. Use one power source SKC Ltd. www.skcltd.com SKC South Africa www.skcsouthafrica.co.za

Leland Legacy Sample Pump Higher Flows for Enhanced Detection Leland Legacy Features/Advantages Constant flow from 5 to 15 L/min Smallest high flow pump available for personal sampling Up to 24-hour run times on one battery charge Corrects flow for changes in temperature and atmospheric pressure Programmable using keypad or optional DataTrac Software and PC Automatic flow fault and restart Perfect partner for SKC 8 L/min Respirable PPI Sampler or higher flow cyclones Ordering Leland Legacy Starter Kit includes pump, # charger (100-240 V), 3 feet (0.9 meter) of Tygon tubing, and collar clip with cable tie 100-240 V 100-3002-S Single Pump Kit includes pump # and single charger, in a Pelican carry case 100-240 V 100-3002K 5-pack Pump Kit includes 5 Leland Legacy pumps, # one Take Charge 5 Multi-charger, and DataTrac Software, in a Pelican carry case 100-240 V 100-3002K5 Use in non-explosive environments only. Not UL Listed for intrinsic safety Leland Legacy pumps contain Li-Ion batteries and are subject to special shipping regulations. # Leland Legacy is not recommended for high back pressure applications such as asbestos clearance sampling. Accessories DataTrac Software for Leland Legacy includes software on CD and USB cable 877-92 Noise-reducing Pump Pouch, black nylon, reduces pump noise from 62.5 to 52 db 224-89 TSI 4146 Airflow Calibration Kit, flow measurement from 0.01 to 20 L/min, includes calibrator, soft-sided case, mounting lugs, 1/4-inch ID tubing, battery pack, 6 AA batteries, inlet filter, dampening module, NIST certificate, and manual 740-4146 Rotameter, 2 to 20 L/min, 4-inch scale 320-4A20L Measured 39 inches (1 meter) from pump operating at 10 L/min without media Flow Range: 5 to 15 L/min Power/Run Time: Li-Ion battery/up to 24 hrs (depending on dust load) Back Pressure: Up to 12 inches water at 10 L/min Tubing: 3/8-in ID Weight: 1 kg (36 oz) Dimensions: 8 x 3.9 x 2.6 in (20 x 10 x 7 cm) Calibrator: TSI 4146; see left Recommended for use with: 8 L/min PPI on pages 4 and 5 Visit www.skcinc.com/pumps/100-3000.asp for more information. SKC Asia www.skc-asia.com SKC Inc. www.skcinc.com 7