Pilot Check Valve: Metal Body Type

Similar documents
Clean Speed Controller with One-touch Fitting

Related Products: Auto Drain Valve. Model/Specifications. Model

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

PVC Quick Drain Valve

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Air Saving Valve. Pressure Valve Flow Valve

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Coiling Tube with Twist-Proof Fitting

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Low Friction Cylinders

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Operation Manual Air Saver Unit ASV5000 Series

Direct Operated Precision Regulator Modular Style. Standard Specifications

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

reduces flow setting time and setting errors!

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Push-In Fitting Type with Stop Valve

Air operated valve. VGA342R Series

Series AMJ. Drain Separator for Vacuum

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Push-In Fitting Type Silencer

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Push-In Fitting Type Pressure Gauge

Low torque Metal seal type Rotary joint

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

Series IRV1000/2000/3000

VACUUM REGULATORS CONTENTS

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Speed Controller Anti-spatter Series

Piloted Non-Return Valves

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

5 Port Air Operated Valve

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Clean Regulator/Fluororesin Type

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Process Pump. Series PAF3000/Series PAF5000

F.R.L. Units Precautions 1 Be sure to read this before handling.

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

AS13 1F-M3 AS13 1F-M5 AS23 1F-01 AS23 1F-02

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Booster Regulator/Air Tank

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Standard Specifications

Pressure Gauge Series

Tube Cutter with Measuring tape built-in

Multi Core Tube for General Pneumatic Piping

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Industrial Filter. FGD series

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Precision Regulator. Series Model Regulating pressure range Port size Page

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

ALF400 to 900, ALT-5/-9

IR1000-A IR1010-A IR1020-A

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Tube for General Pneumatic Piping

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Speed Controller Constant Flow

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Smooth Vent Valve XVD. Series

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Smooth Vent Valve. XVD Series

Compressed Air Cleaning Filter Series

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Modular Type Regulators

Transcription:

INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not guaranteed. Three types capable of connecting to female threads and s are available. Rotates 360 Example of a drop prevention circuit Workpiece Flame-resistant resin (Equivalent to UL-94 Standard V-0) : Female thread : Female thread : Male thread Port size on the valve side Port size on the Female thread (Rc, G) cylinder side 1/8 1/4 3/8 1/2 AS2200-m01m-X785 1/8 M5 V AS2200-m02m-X785 1/4 V R, G 1/8 AS3200-m03m-X785 3/8 Rc, G V AS4200-m04m-X785 1/2 1/4 V : Female thread : Port size on the cylinder side Port size on the valve side ø10 AS4201-m04-Fmm-X785 R, G 1/2 Rc, G 1/4 V V ø12 : Male thread : : : Male thread Port size on the valve side Port size on the cylinder side ø6 ø8 ø10 AS2201-m01-Fmm-X785 1/8 V V AS2201-m02-Fmm-X785 R, G 1/4 ø6 V V V AS3201-m03-Fmm-X785 3/8 V V AS-X785 16-E672

AS-X785 Specifications Symbol Fluid Proof pressure Max. operating pressure Min. operating pressure Pilot check valve operating pressure Ambient and fluid temperatures Applicable tubing materials Air 1.5 MPa 1 MPa 0.1 MPa 50% or more of the operating pressure (0.1 MPa or more) 5 to 60 C (No freezing) Nylon, Soft nylon, Polyurethane * Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.) Flow Rate and Sonic Conductance AS2200-m01m-X785 AS2201-m01-Fmm-X785 AS2200-m02m-X785 AS2201-m02-Fmm-X785 AS3200-m03m-X785 AS3201-m03-Fmm-X785 AS4200-m04m-X785 AS4201-m04-Fmm-X785 Port size on the valve side ø6, ø8, 1/8 ø6, ø8 ø10, 1/4 ø8 ø10, 3/8 ø10 ø12, 1/2 Sonic conductance [dm 3 /(s bar)] 0.8 1.3 1.4 3.1 3.2 5.1 5.8 Critical pressure ratio 0.25 0.25 0.25 0.25 0.25 0.25 0.25 How to Order AS 2 200 01 S X785 Body size 2 1/8, 1/4 3 3/8 4 1/2 Thread type Nil R, Rc G G Port size 01 1/8 02 1/4 03 3/8 04 1/2 Seal method Nil Without sealant (for G) S With sealant (for R) * R thread type: With sealant G thread type: Without sealant AS4201 Thread type Nil R, Rc G G 04 Port size 04 1/2 With F 10 S X785 Seal method Nil Without sealant (for G) S With sealant (for R) * R thread type: With sealant G thread type: Without sealant applicable tubing O.D.*1 10 ø10 12 ø12 *1 For selecting applicable tubing O.D., refer to the cover page. 1 AS Body size 2 1/8, 1/4 3 3/8 2 201 01 F 06 S Thread type Nil R G G Port size 01 1/8 02 1/4 03 3/8 With s X785 Seal method Nil Without sealant (for G) S With sealant (for R) * R thread type: With sealant G thread type: Without sealant applicable tubing O.D.*1 06 ø6 08 ø8 10 ø10 *1 For selecting applicable tubing O.D., refer to the cover page.

Pilot Check Valve: Metal Body Type AS-X785 Construction Female thread () With s () @0 y!4!3 i w o r!5 q!2!1!9!8 y!4!3 i w r o u!5!2!1 u t!6!7!0!6!7 e!0 t q e!6 t!7!0 @1 e : G thread : Female thread!6!7@1 e!0t q Component Parts No. Description Material Note 1 Body A ZDC Platinum silver 2 Pilot body Brass Electroless nickel plating 3 Guide Brass Electroless nickel plating 4 Piston Brass Electroless nickel plating 5 Valve Stainless steel, NBR 6 Cover Brass Electroless nickel plating 7 DY seal NBR 8 DY seal NBR 9 Spring Stainless steel 10 Spring Stainless steel 11 Cassette Attached to body A for the type No. Description Material Note 12 Seal NBR 13 O-ring NBR 14 Ring Stainless steel 15 O-ring NBR 16 O-ring NBR 17 Bushing PBT/Brass Brass (Electroless nickel plating) for G thread 18 O-ring NBR 19 Gasket NBR 20 Domed cap nut Stainless steel 21 O-ring Only for G thread 2

AS-X785 Dimensions AS2200/3200/4200-mS-X785 AS2200/3200/4200-Gm-X785 T3 T3 T2 T2 T2 T3 H1 H2 D1 D2 Weight [g] AS2200-01S-X785 R1/8 Rc1/8 M5 x 0.8 8 12 14.3 14.6 18 25.3 13.2 38.6 35 AS2200-G01-X785 G1/8 G1/8 M5 x 0.8 8 12 14.3 14.6 18 25.3 13.2 38.6 40 AS2200-02S-X785 R1/4 Rc1/4 Rc1/8 12 17 18 19.5 27.2 36.95 17.5 46.2 77 AS2200-G02-X785 G1/4 G1/4 G1/8 12 17 18 19.5 27.2 36.95 17.5 45.1 85 AS3200-03S-X785 R3/8 Rc3/8 Rc1/8 12 19 22.5 24.3 30 42.15 19.7 55.1 125 AS3200-G03-X785 G3/8 G3/8 G1/8 12 19 22.5 24.3 30 42.15 19.7 55.1 140 AS4200-04S-X785 R1/2 Rc1/2 Rc1/4 17 24 27.5 28.5 38.5 52.75 25.8 69.4 225 AS4200-G04-X785 G1/2 G1/2 G1/4 17 24 27.5 28.5 38.5 52.75 25.8 69.4 250 [mm] 3

Pilot Check Valve: Metal Body Type AS-X785 Dimensions AS4201-04-FmS-X785 AS4201-G04-Fm-X785 T3 T3 Applicable tubing O.D. øt2 Applicable tubing O.D. øt2 M1 M1 øt2 T3 H1 H2 D1 D2 M1 Weight [g] AS4201-04-F10S-X785 R1/2 ø10 Rc1/4 17 24 22.3 28.5 36.1 50.4 24.6 71 21 190 AS4201-04-F12S-X785 R1/2 ø12 Rc1/4 17 24 22.3 28.5 36.1 50.4 24.6 71 22 183 AS4201-G04-F10-X785 G1/2 ø10 G1/4 17 24 22.3 28.5 36.1 50.4 24.6 71 21 215 AS4201-G04-F12-X785 G1/2 ø12 G1/4 17 24 22.3 28.5 36.1 50.4 24.6 71 22 208 [mm] 4

AS-X785 Dimensions AS2201/3201-m-FmS-X785 AS2201/3201-Gm-Fm-X785 Applicable tubing O.D. øt3 L4 M2 Applicable tubing O.D. øt3 L4 M2 ød3 Applicable tubing O.D. øt2 ød3 Applicable tubing O.D. øt2 M1 M1 øt2 øt3 H1 H2 D1 D2 D3 L4 M1 M2 Weight [g] AS2201-01-F06S-X785 R1/8 ø6 ø6 8 12 15.5 14.6 13 26.6 33.9 13.8 21.5 57 17 17 48 AS2201-01-F08S-X785 R1/8 ø8 ø6 8 12 15.5 14.6 13 26.6 33.9 13.8 21.5 57 18.5 17 45 AS2201-G01-F06-X785 G1/8 ø6 ø6 8 12 15.5 14.6 13 26.6 33.9 13.8 21.5 57 17 17 53 AS2201-G01-F08-X785 G1/8 ø8 ø6 8 12 15.5 14.6 13 26.6 33.9 13.8 21.5 57 18.5 17 50 AS2201-02-F06S-X785 R1/4 ø6 ø6 8 17 15.5 19.5 13 28.7 38.5 17.2 21.5 65 17 17 82 AS2201-02-F08S-X785 R1/4 ø8 ø6 8 17 15.5 19.5 13 28.7 38.5 17.2 21.5 65 18.5 17 78 AS2201-02-F10S-X785 R1/4 ø10 ø6 8 17 18.2 19.5 13 34.5 44.3 18.6 21.5 65 21 17 80 AS2201-G02-F06-X785 G1/4 ø6 ø6 8 17 15.5 19.5 13 28.7 38.5 17.2 21.5 64 17 17 90 AS2201-G02-F08-X785 G1/4 ø8 ø6 8 17 15.5 19.5 13 28.7 38.5 17.2 21.5 64 18.5 17 86 AS2201-G02-F10-X785 G1/4 ø10 ø6 8 17 18.2 19.5 13 34.5 44.3 18.6 21.5 64 21 17 88 AS3201-03-F08S-X785 R3/8 ø8 ø6 8 19 18.2 24.3 13 32.7 44.9 19 21.5 71 18.5 17 118 AS3201-03-F10S-X785 R3/8 ø10 ø6 8 19 18.2 24.3 13 33.3 45.5 19 21.5 71 21 17 113 AS3201-G03-F08-X785 G3/8 ø8 ø6 8 19 18.2 24.3 13 32.7 44.9 19 21.5 71 18.5 17 133 AS3201-G03-F10-X785 G3/8 ø10 ø6 8 19 18.2 24.3 13 33.3 44.5 19 21.5 71 21 17 128 [mm] 5

AS-X785 Specific Product Precautions Be sure to read this before handling the products. For safety instructions and flow control equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www.smcworld.com Design/Selection 1. This product cannot be used for accurate and precise intermediate stops of the actuator. Due to the compressibility of air as a fluid, the actuator will continue to move until it reaches a position of pressure balance, even though the pilot check valve closes with an intermediate stop signal. 2. This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3. Consider the release of residual pressure. Actuators may move suddenly due to residual pressure, which can be dangerous during maintenance procedures. 4. When used in a balance control circuit, there are instances in which the check valve cannot release, even though the pilot pressure is 50% of the operating pressure. In these cases, the pilot pressure should be the same as the operating pressure. 5. For reference, SMC has conducted endurance tests in which ON and OFF operation of the check valve was performed at the maximum operating pressure with a confirmed endurance of 10 million cycles. Since the tests were performed under limited conditions, use caution in evaluating the results. 6. The check valve has a construction in which it is closed by the differential pressure generated when the inlet pressure (IN side) or outlet pressure (OUT side) solenoid valve is switched. Be aware that the check valve does not close completely and the outlet pressure (OUT side) may drop when the inlet pressure (IN side) drops slowly and the differential pressure becomes smaller than the minimum operating pressure or cracking pressure. 7. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. Installation 1. When mounting, firmly align the tool to be used with the hexagonal portion of the pilot body. If the hexagonal portion is damaged as a result of failure to properly align the tool, the pilot body will be deformed, and poor pilot operation may result. 2. Do not use fittings for applications involving continuous rotation. The product may be damaged. Air Source 1. If moisture enters the inside of the connected piping, the cover may corrode, leading to a pilot operation malfunction. 2. When there is a large amount of drainage Compressed air containing a large amount of drainage can cause the malfunction of pneumatic equipment. An air dryer or water separator should be installed upstream from filters. Caution 1. Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 μm or smaller. Operating Environment 1. Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Refer to each construction drawing for information on the materials of flow control equipment. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibration and/or shock. 4. Do not mount the product in locations where it is exposed to radiant heat. Maintenance 1. Perform maintenance inspections according to the procedures indicated in the operation manual. If handled improperly, malfunction or damage of machinery and equipment may occur. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling, repair, and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person. 3. Drain flushing Remove drainage from air filters regularly. 4. Removal of equipment, and supply/exhaust of compressed air Before components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function. When machinery is restarted, proceed with caution after confirming that appropriate measures are in place to prevent sudden movement. 6

Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.