IN-SITU ZIRCONIA OXYGEN ANALYZER < ZIRCOMAT-C >

Similar documents
ZIRCONIA OXYGEN ANALYZER CONVERTER

Integral type Differential pressure flowmeter VNT Series

ZIRCONIA OXYGEN ANALYZER CONVERTER

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

ZIRCONIA OXYGEN ANALYZER CONVERTER

TH-1800-T TRX-700-CNG Converter

Design Features. General Description

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Model EXAxt AV550G. Averaging Oxygen Analyzer

Columbus Instruments

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Model ZX8D Zirconia Oxygen Analyzer

Autocalibration Systems For In Situ Oxygen Analyzers

SM425 ZIRCONIA OXYGEN ANALYZER

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

High-performance submersible pressure transmitter For level measurement Model LH-10

OXYGEN MONITORING SYSTEM OMS

Mass Flow Controller (MFC) for Gases

Technical Data Sheet MF010-O-LC

Best Practice Guide, Servomex 2700

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

SITRANS P measuring instruments for pressure

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Mass Flow Meter (MFM) for Gases

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

analytical bulk flow distance FLOW level pressure temperature industrial communication

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

Mass Flowmeters. Mass Flowmeters for Gases

UNDERSTANDING, ACCELERATED

Level transmitter LT 100

ALF400 to 900, ALT-5/-9

Gas density monitor With integrated transmitter Model GDM-100-TI

Operating Instructions Part No

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Zirconia Oxygen Analyzer Systems

Features. Description

CONTENTS OVERVIEWS PRODUCT INFORMATION

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

General Specifications

Specifications of Oxygen Sensor Module V-8344A

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

FLAMMABLE GAS SENSOR/TRANSMITTER

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

General Specifications

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

IN-SITU ZIRCONIA OXYGEN ANALYZER FOR HAZARDOUS LOCATION ZFKE, ZKME

INSTALLATION & MAINTENANCE INSTRUCTIONS

Electro-Pneumatic Converter YT-940 SERIES

Supplementary Operator s Manual 42/24-14 EN Rev. 3

INFRARED GAS ANALYZER

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Mass Flow Controller (MFC) for Gases

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Mass Flow Controllers

Climatic Independent Level Sensor LAR

Programmable pressure and temperature transmitters PTM/RS485

C-Flow Coriolis Mass Flow Meters

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Instruction Manual Differential Pressure Transmitter

VACUUM REGULATORS CONTENTS

Model PDT Dewpoint Transmitter

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

EPP4 Pressure Regulator Basic G 1/4"

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Mechanical Pressure Measurement

Series IRV1000/2000/3000

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

FTC130 Transmitter. Operating Manual

FAS-W. Features. Applications. Automatic condensation hygrometer

Electro-Pneumatic Valve Positioners

CSA Sample Draw Aspirator Adapter Operator s Manual

SSL. Smart Valve Positioner.

780S Ultra High Purity Series

Precision pressure sensor Basic version Model CPT6020

Autocalibration Systems for In Situ Oxygen Analyzers

Technical Data. General specifications. Rated operating distance s n 5 mm

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Booster Regulator/Air Tank

Model 601CV. Mass Flow Controller. Product Features:

Electropneumatic Transducer (I/P) Installation, Operation and

User and Installation Manual

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

L3 Pressure and Level transmitter

Model ZR202G Integrated type Zirconia Oxygen Analyzer

Oxygen Flue Gas Analyzer BA 2000

Pressure Automated Calibration Equipment

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Transcription:

IN-SITU ZIRCONIA OXYGEN ANALYZER < ZIRCOMAT-C > DATA SHEET ZFK, ZRY This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control. The detector (ZFK) used with the analyzer is directly inserted into the objects measured, eliminating the need for a sampling device and provides quick response. The converter (ZRY) features 3 measuring ranges, one touch calibration and NEMA4 housing. Comparing to the current converter (ZRM), this ZRY is recognized as economical type with simple functions. General-use detector FEATURES. Sampling device is unnecessary Gas sampling devices such as a gas aspirator, a dehumidifier, etc. are unnecessary because of use of directinsertion type detector.. High speed response The adoption of a flow guide tube utilizing the flow of the measured gas assures quick response (less than 7sec). 3. Dust-tight and water-proof housing Aluminum die casting housing of converter satisfies NEMA4 and IP6 standard. 4. 3-measuring ranges and one touch calibration The converter has 0-, 0, vol% 3 ranges easily changed by pin connection and zero and span are simply calibrated by key operation. SPECIFICATIONS General Measuring object: Oxygen contained in noncombustible gas Measuring principle: Direct-insertion zirconia system Measuring range: 0 to, 0 or vol% O (Changed by internal set pin) Repeatability: Within ±.0% of full scale Linearity: ±% of full scale Response time: Within 7sec for 90% response (from calibration gas inlet) Power supply: 00,, 0 or 30V AC, 0/60Hz Power consumption: (approx.) + 0VA (at steady state) + 00VA (at start) Warmup time: Approx. min Converter Oxygen detector (ZFK, ) Measuring detector: For general-use: ZFK For corrosive gas: ZFK Measured gas temperature: system; 0 to +600 C Measured gas pressure: 3 to +3kPa : Flange; JISK 6A FF (JISK-80AFF for high particulate gas) Insertion length; 0.3, 0., 0.7, m (0.8m for high particulate gas) Ambient temperature: 0 to +60 C for cable section C or less at detector flange surface with power applied Structure: Dust/rain-proof structure(iec IP equivalent) Filter: Alumina(filtering accuracy 0μm) and quartz paper Main materials of gas-contacting parts: General-use detector(zfk ); Zirconia, SUS36, platinum, SUS304 Anticorrosive detector(zfk ); Zirconia, tita-nium, platinum, SUS36 ; SUS304 or SUS36 EDSX3-9a Date Sep.0,999

ZFK, ZRY Calibration gas inlet: Brass joint for φ/4 inch tube. Reference air inlet (option): Rc/8 or NPT/8 Detector mounting: Horizontal plane ± 4, ambient surrounding air should be clean. Outer dimensions: (L x max. dia.) 0mm x 00mm (detector) Mass (approx.) {weight}: Detector;.6kg (general-use, m); kg Finish color: Silver and SUS metallic color Oxygen converter (ZRY) Measuring range: 0-, 0, vol% O Changeable by internal set pin. Repeatability: ±.0% of full scale Lineality: ±.0% of full scale Indication: Oxygen concentration; 3-digit LED Oxygen concentration output signal: 4 to 0mA DC (allowable load resistance: 00 Ω or less) Isolated output, linear Fault contact output: 0V AC, A rating (close contact or open contact for fault should be specified when you place an order.) Self-diagnoses: Fault of sensor temperature, zero calibration error, span calibration error Calibration method: Manual calibration with key operation Calibration gas: Recommended calibration gas concentration Zero gas;.0 to.0% O Span gas; 0.6 to.0% O (oxygen concentration in the air) Ambient temperature: 0 to +0 C Ambient humidity: 90% RH or less Power supply: 90 to 0 or 30 V AC, 0/60Hz Construction: Dust-tight, waterproof construction, NEMA4 (corresponding to IP6 of IEC) Material: Aluminum die casting Outer dimensions (H x W x D): 0 X 30 X 9mm Mass {weight}: Approx. 4.kg (excluding cable and detector) Finish color: Munsell 6PB 3./0. (blue): cover, silver; case Mounting method: Mounted flush on panel Exclusine cable (ZRZP) Cable: 4-cores sealed wire (O signal and R- themo couple signal) and -cores cable (power) Cable conduit: Flexible type Length: Refer to code symbols SCOPE OF DELIVERY Detector: Detector main unit x, Viton O ring x, mounting screw (Mmm x ) x 6, thermal sticker x, flow guide tube (as specified) x, ceramic filter x, cover (as specified) x, reference air inlet (as specified) x Converter: Converter main unit x Accessories (AC0V 00mA T fuse x, AC0V 3.A T fuse x ) Items to be prepared separately: () Standard gas for calibration Type ZBM NSK4-0 () Reduction valve for standard gas (type ZBD6003) (3) Flowmeter Type; ZBD03, 0. to L/min (for calibrating gas) CAUTIONS If combustible gas (CO, H etc.) exists in the measured gas, error will occur due to burning at the sensor section. The inclusion of corrosive gas (Si vapor, alkaline metal, P, Pb etc.) will shorten the life of the sensor. When the measured gas temperature is high (+300 C or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value + C). The flow guide should be attached in the direction in which the gas flow to the detector decreases. When dust more than g/nm 3 is included in the gas, manual blow down is necessary. The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TZ73704. The applicable standards used to demonstrate compliance are : EN 0 : 99 CLASSA Conducted and Radiated emissions EN 008- : 99 Radiated immunity, ESD and FBT ZFK, ZRY

DEVICE CONFIGURATION The device to be combined differ according to the conditions of the gas to be measured. Please select the devices to be combined with reference to the following table. Measured gas Device configuration Application Temperature Gas Flow DUST Protection cover Note Detector type Converter type Ejector type General-use 600 C or (boiler) less Anti-corrosive use (incinerator) to 0m/s Less than 0.g/m 3 [nor] Less than 0g/m 3 [nor] no Less than g/m 3 [nor] yes Fuel; gas, oil Fuel: coal with manual blow down Included high moisture with manual blow down ZFK R 4- ZFK R 4-6 D 8 ZFK R 4-6 E 8 ZRY ZRY ZRY Note () Dust volume is approximate value. () Instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet, when oxygen concentration in air around sensor changes. CODE SYMBOLS (Detector) 4 6 7 8 ZFK R 4 3 9 03 0 Y 0 A 3 A A 7 A B 3 B B 7 B 6 D 8 6 E 8 Y A Y A B Cal. gas inlet For φ/4 inch tube ( Replacement Detector element) 4 6 7 8 ZFK R 4 3 9 03 Description Application General use. For corrosive gas (refuse incinerator) Power supply 00/VAC 0/60Hz 00/0VAC 0/60Hz 30VAC 0/60Hz (CE-marking approved) flange application length SUS304 general use 300mm SUS304 general use 00mm SUS304 general use 70mm SUS304 general use 000mm SUS36 for corrosive gas 300mm SUS36 for corrosive gas 00mm SUS36 for corrosive gas 70mm SUS36 for corrosive gas 000mm SUS36 for high particulate 800mm SUS36 for high particulate with 800mm cover Protection cover Without With Reference air inlet Non Rc/8 NPT/8 Description Application General use. For corrosive gas (refuse in cinerator) Cal. gas inlet For φ/4 inch tube Power supply 00/VAC 0/60Hz 00/0VAC 0/60Hz 30VAC 0/60Hz (Converter) 3 4 6 7 8 9 0 Z R Y Y - R 0 B C (Exclusive-special cable) 3 4 6 7 8 Z R Z PR P R YA YB YC YD YE YF YG YH YJ YK YL YM AA BB CC DD - 9 0 Y E Description Connectable devices For ZRY Types For R thermocouple Conduit length Cable length 6m 0m m 0m 30m 40m 0m 60m 70m 80m 90m 00m 6m 6m 0m 0m m m 0m 0m Cable end treatment One side (detector side) Both sides Note: Description Output signal and fault output 4 to 0mA DC, close contact 4 to 0mA DC, open contact Power supply 90 to 30V AC 0/60Hz (CE marking approved) Mounting method Panel mounting Instruction manual NO YES (English) For connection between detector and converter, the conduit to be used should be rainproof flexible type. 3

ZFK, ZRY CONFIGURATION system Cover for retaining warmth Status of fault contact output Detector ZFK digit of model Power off Power on and normal Power on and fault B open open close Gas temperature. 600 C max. C open close open Sample gas outlet *3 Ball valve 3 4 6 Bule Black Red Yellow White White Rainproof flexible conduit. 0m max. Gas temperature. 600 C max. -core cable 4-core cable Thermocouple signal Zirconia signal Converter (ZRY) Analog output Fault contact output Sensor heater for high particulate 6mm or 4 inch tube for calibration gas (not supplied) *3 Ball valve 3 4 6 7 8 9 0 3 4 Red White Blue Yellow Cell/thermocouple output Heater power supply DC4 to 0mA Black White AC power supply Sample gas outlet Gas temperature. 600 C max. Flow guide for high particulate with cover Change valve Reduction valve (ZBD6) to Detector * Ref. air Flowmeter (ZBD4) ( to.l/min) Standrad gas for zero point (ZBM) Reduction valve (unnecessary when supply air pressure is 0 to 00kPa * Air supply (0. to 0.L/min) Reduction vale (ZBD6) * Standard gas for span point (ZBM) Note * Sandard gas or instrumentation air can be used in place of span gas. * Instrument quality air or bottled air is available as reference air instead of ambient air, when oxygen concentration in air around sensor changes. *3 Blow down air inlet pressure in 00 to 300kpa. 4

60 OUTLINE DIAGRAM (Unit:mm) Detector (ZFK) Proof cover (to order) Approx. 30 Approx. 6 Approx. 8 80 4.4 36 6 Filter EXTERNAL CONNECTION DIAGRAM 8 Heater Thermocouple Element output A Approx. Ref. air inlet (to order) NPT/8 or Rc/8 6-6 3 4 6 Black / White/ Red / White/ Yellow / Blue -core wire 4-core wire Exclusive-special cable Exclusive cable gland Calibration gas inlet for /4 inch tube. Approx. L Approx. 0 30 Gas inlet 0 34 Z F K R 4 - A 3 7 Gas outlet 6-M detector side Oxygen detector Cord th L (m) MASS Approx (kg) 3 7 0.3 0. 0.7.0.7 3.3 4. 4.8 Z L= (to order) 8 MTG. holes

ZFK, ZRY Detector (ZFK) Proof cover (to order) Approx. 30 Approx. 6 Approx. 8 80 4.4 36 6 Filter EXTERNAL CONNECTION DIAGRAM 8 Heater Thermocouple Element output 60 Approx. 3 Ref. air inlet (to order) NPT/8 or Rc/8 6-6 3 4 6 Black / White/ Red / White/ Yellow / Blue -core wire 4-core wire Exclusive-special cable Exclusive cable gland Calibration gas inlet for /4 inch tube. 3 Approx. L Approx. 40 30 Gas inlet 60. Z F K R 4 - B 3 7 Gas outlet 6-M detctor side Oxygen detector Cord th L (m) MASS Approx (kg) 3 7 0.3 0. 0.7.0 3.3 4. 6. 7.6 Z L= (to order) 8- MTG. holes 6

(for high particulate) 4 - Rc /4 with plug int thd. 80 4 Blow down air inlet 8-9 MTG. hole Select an upper port to avoid the condensation in the piping 9. Flange: JIS K80A FF ZFK MTG. position Packing 8 Z F K R 4-6 D8 0 Gas outlet 800 30 Gas flow Tube (0A SCH40) (for high particulate with cover) 4 - Rc /4 with plug int thd. 80 4 8-9 MTG. holes Blow down air inlet Select an upper port to avoid the condensation in the piping 9. Flange: JIS K80A FF ZFK MTG. position Packing (7) 0 Z F K R 4-6 E8 Gas outlet (790) 800 30 Gas flow Protection tube (6A SCH40) (38) Tube (0A SCH40) 7

ZFK, ZRY Converter (ZRY) Panel flush mounted -φ9 7 3 0 0 3. 9 4 30 CABLE GRAND φ 39 -G/ 40 40 40 40 CONNECTION DIAGRAM 3 4 6 7 8 9 0 3 4 + + + L N THERMO- COUPLE ELEMENT INPUT OUTPUT SIGNAL FAULT CONTACT OUTPUT HEATER POWER FOR SENSOR POWER SUPPLY Fuji Electric Your distributor: Coulton Instrumentation Ltd 7 Somerford Business Park, Christchurch, BH3 3RU, UK Tel: +44 0 480 303 E-mail: sales@coulton.com Web: www.coulton.com Information in this catalog is subject to change without notice. Printed in Japan