Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Similar documents
Process: Chlorine etch. Item Qty Description Price/Unit Total

Standard Operating Manual

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

Operating Procedures for the. SAMCO ICP RIE System

NORDSON MARCH PX-1000 PLASMA ASHER STANDARD OPERATING PROCEDURE Version: 1.0 July 2016

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

Review of the Hall B Gas System Hardware. George Jacobs

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

INVITATION FOR QUOTATION. TEQIP-III/2019/mmug/Shopping/51

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

NIT LIMITED NO. RD-NC-40-SPS-PH

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Arizona State University NanoFab PLASMATHERM 790 RIE. Version A

OXFORD PLASMALAB 80PLUS (CLOEY)

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Standard Operating Manual

Usage Policies Notebook for Trion RIE / ICP Dry Etch

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

University of MN, Minnesota Nano Center Standard Operating Procedure

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

Notes-PECVD: Chamber 1

Lam Rainbow and TCP Product Status Checklist. System Type: Poly Etcher System Model: 4420 D.O.M.:

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

त जप र व श व द य लय / TEZPUR UNIVERSITY क ल सध क क य लय/ OFFICE OF THE REGISTRAR SHORT QUOTATION NOTICE

NIT LIMITED NO. NC-185-SCS-P-NOCB ARGON & NITROGEN CYLINDER WITH REGULATOR

Usage Policies Notebook for STS DRIE System

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

March CS-1701F Reactive Ion Etcher

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Plasma Asher: March PX-500 User guide (May-30, 2017)

BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE:

Long term stability tests of INO RPC prototypes

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

RAPID THERMAL PROCESSOR (Annealsys AS-ONE 150) Lab Manual

Application Note AN-107

Oxford Instruments Plasma Technology

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Standard Operating Manual

Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Porter Analytical & Industrial Products

PRC CO ² -LASER PRESENTATION

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

STS PECVD Instructions

Nordiko Metal Sputtering System Standard Operating Procedure

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Major Design Features

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Standard Operating Manual

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

MANUAL FOR SPTS APS (DIELECTRICS ETCHER)

Chapter 2 General description of the system

RAC 2200-X/Y-MV DOMESTIC WATER METER TEST BENCH UP TO DN 50 ( 2 ) MANUALLY OPERATED

Xactix Xenon Difluoride Etcher

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

FTC130 Transmitter. Operating Manual

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Description Advanced Features Typical Applications

STS DRIE User SOP Location: NRF Cleanroon, Dry Etch Bay

Operational Settings:

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Calera Fire Department Breathing Air System Technical Specifications

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Usage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100

OIL INDIA LIMITED (A Government of India Enterprises) 4, India Exchange Place Kolkata -1 INVITATION TO E-BID UNDER COMPOSITE BID SYSTEM

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Model 10. Low-Medium Pressure Reducing Regulator

NATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Porter Lab & Analytical Products

ACV-10 Automatic Control Valve

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

NNCI ETCH WORKSHOP SI DRIE IN PLASMATHERM DEEP SILICON ETCHER. Usha Raghuram Stanford Nanofabrication Facility Stanford, CA May 25, 2016

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Autocalibration Systems for In Situ Oxygen Analyzers

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Test Facilities Experiment Review

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents


Pressure Automated Calibration Equipment

Valve test benches. Systems overview

Mass Spec will not Autotune

HumiSys HF High Flow RH Generator

Basic ICP Operating Procedures

Additel 761 Automated Pressure Calibrators Selection Guide

For Department of CSSD

Additel 761 Automated Pressure Calibrators

Transcription:

Fax: + 91-0512-2596620 Phones: + 91-0512-2596622,6088 Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Enquiry number: SCDT/FlexE/2016-17/02 Date:05/05/2016 Sealed Quotations from prospective vendors are invited by Samtel Center for Display Technologies, IIT Kanpur for REACTIVE ION ETCHINGDetailed specifications, term and conditions are mentioned below: te: The technical and financial bid should be submitted together in separately sealed envelopes The REACTIVE ION ETCHINGMust have following minimum technical specifications Sl 1 2 Technical specifications for REACTIVE ION ETCHING: System Specifications: RIE(Reactive Ion Etching) System for R&D/pilot production, up to one 6" 6"squaresample's process System should also be able to process odd-shaped smaller samples The RIE system should be used to anisotropic etching ofsemiconductors and dielectrics, eg Silicon, SiN, and SiO2 System Process Module should have a small foot-print For example, it can house all electronic sub systems, control units, pneumatics and Turbo pump comply/t applicable 3 System should be fully software controlledthe user interface should allow both automatic and manualoperation 4 The software interlocks for high voltage, water, gas and vacuum and an emergency shutdown 5 Data to be stored in open format SQL database or similar, data logging should adhere to ANSI-ISA 88 standard 6 Remote Support: System should come with provision for remote access, such that the OEM should be able to login remotely into the system The OEM should be able to troubleshoot the system remotely, as well as perform software upgrades 7 Software upgrades should be free for the entire life of the system 8 9 The system should be CE certified System should provide full safety interlock along with EMO buttons in front and back

10 System should have power supply configuration as per Indian standards 11 System should have password protected operator access levels Sl 12 13 Chamber Configuration: The chamber should be capable of handling up to 6 X 6 glass substrates System should also be able to process odd-shaped smaller samples Process Chamber: Should be made of single block of Aluminum to ensure maximum vacuum integrity The chamber should have viewport(s) comply/t applicable 14 15 16 17 Electrode Size: 200mm diameter or larger Electrode cooling: Ambient and/or liquid cooled Chiller for maintaining electrode temperature should be included with the system Electrode Material: Aluminum RF Electrode Bias: Greater than or equal to 300W solid state RF power supply, 1356 MHz, coupled with automatic matching network The matching network should be capable of manual tuning as well Sl Vacuum Specifications: comply/t applicable 18 Turbo Pump with a mechanical backing pump with fomblin oil charge The pumps should be capable of handling corrosive gases Dry pump should be given as an option 19 20 21 Base Pressure: System should be able to reach 10-4 Pabase pressure in less than 1 Hr Pump down feature should be such that it minimizes the turbulence, wafer movements and particle generation during the pump down Pressure Control: Fast and accurate Automatic Closed Loop Pressure Control with Digitally controlled Valve 22 Process Pressure range: 0 to 1000mT System should be equipped with Digital heated Capacitance Manometer for accurate process pressure control 23 Appropriate gauges should also be included for wide range pressure measurement (low to high pressure)

Sl System Gas Manifold Specifications: comply/t applicable 24 Gas Enclosure with extraction point to ensure safety 25 26 Digitally controlled Mass Flow Controllers to be provided Each gas channel to include a normally closed isolation valve on the inlet and outlet of MFCs 27 Gas lines should be constructed of 10 RA finish 316 stainless steel tube 28 The common process gas mixing manifold should include a normally closed process gas isolation valve 29 Gas lines and MFCs to be provided for SF6, CF4, Ar, O2 30 SF6 and CF4 gas line to be equipped with Flush/bypass capability 31 Gas Manifold should be capable of adding 2 more lines in the future 32 Gas manifold should be capable of Flush/bypass for future lines 33 System should come with N2 purge capability Sl Process Specifications: comply/t applicable 34 Si, SiO2, SiNx, SiOxNy etch recipes should be provided 35 Appropriate cooling mechanism in order to prevent overheating during the etch process (typical etching time will be 30 seconds to 5 minutes) 36 Uniformity across 6 wafer should be ±5% 37 Batch to batch uniformity should be ±5%

Sl 38 Scrubber Specification (To be quoted as Optional): System should be supplied with a Scrubber for the abatement of F based by products comply/t applicable 39 Should be compact and stand alone 40 Should be easy to run and maintain 41 Should have chemisorption based dry scrubbing technology 42 Room temperature operation 43 Single Column based passive system with no utility requirement such as water or power, so that system can continue to function in case of utility failure 44 Inlet and outlet of the scrubber should have KF40 connectors 45 F based exhaust gas concentration at the outlet of scrubber should be below universally accepted Threshold Limit Values 46 Detector to indicate the life of scrubber should be quoted as optional 47 Systems components should be from reputed OEM 48 Systems should require no or minimal maintenance post-installation until the life of the scrubber column 49 Vendor should provide disposal and replacement service of active media in India 50 International vendors should have a local agent in India to provide after sales service and technical support The local agent should have worked with the vendor for at least 3 years 51 Technical literature, brochure, catalogue should be provided Terms and Conditions: te- (All terms & conditions must be fulfilled by the manufacturer /supplier) 1 Detailed compliance sheets are to be attached with Technical Bids for evaluation 2 Make and build year of all OEM components not manufactured by the vendor should be separately provided

3 Detailed documentation about (a) installation (b) maintenance (c) servicemanual including OEM parts, circuit drawings should be given preferably on clean room papersall technical documents should be in English 4 Technical bid should include Drawing of the system with internal arrangements of sub-assemblies, and system dimensional details/footprint along with peripherals and utilities 5 Warranty for 2 years should be included in the main quote 6 Warranty for an additional 2 years should be quoted as optional 7 The Warranty must start from the date of installation at IITK 8 Installation and training at customer site should be included in the offer 9 Installation, demonstration, and training-sessions at IIT Kanpur will have to be provided by the manufacturer or the vendor for the quoted system 10 Site preparation requirements should be clearly provided 11 Recipes for Si, SiO2, SiNx, SiOxNy should be provided at the time of installation 12 Recipes should be demonstrated during the time of installation 13 System should be capable of being upgraded for more gas lines in the future without any change in the main system hardware 14 Supplier who has supplied similar System in the national and international institutions will be preferred 15 The vendor should submit the user list along with tenderfor similar system installed in India and abroad 16 Supplier/Vendors should submit technical and financial bids together in separately sealed envelopes 17 Financial bid should include all discounts (educational, research, special etc) 18 Financial bid will be open only for those, who meet tender technical specification 19 Please do mention tender number clearly on envelop 20 Quotation must indicate FOB prices 21 Payment terms & condition is 70% against delivery, 20% after installation and 10% after successful running of equipment for 3 months & approval 22 Quotation should carry proper certifications like proprietary certificate, authorization certificate from manufacturer, etc 23 Validity of quotation should be at least for 60 days 24 Institute is exempted for partial custom duty (CD applicable to IIT Kanpur is 515%) 25 Institute is exempted from payment of Excise Duty under notification 10/97 26 The delivery period should be specifically stated Earlier delivery may be preferred 27 The indenter reserves the right to withhold placement of final order The right to reject all or any of the quotations and to split up the requirements or relax any or all of the above conditions without assigning any reason is reserved Kindly send the quotation in sealed envelopes latest by 3:00 pm on dated 17/05/2016 to the following address: To, Dr Ashutosh Kumar Tripathi Room 310, Samtel Centre for Display Technologies (SCDT), Indian Institute of Technology Kanpur, Kanpur 208016, Uttar Pradesh, India Contact: (+91)07800354333