LAZY RIVER 3 3 PUMP LOCATION

Similar documents
-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Installation Instructions

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

Hydrotherapy Jets System for a Fiberglass Pool

Swimming Pools, Hot Tubs and Spas

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

22. Specialty Valves.

Swimming Pool Requirements

Swimming Pool Requirements Packet

T Y P E V S A B M S E W A G E P U M P

Swim Spa Pre-delivery Guide

You are now the proud new owner of an Alpine Swim Spa!

Multi-Flow Product Catalog

RIVERFLOW PUMP INSTALLATION GUIDE

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

COUNTER CURRENT UNIT. Instruction Manual

RANGER PROP BUILDING INSTRUCTIONS & PHOTOS

Perched Box Caisson Overview. January 2014

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

SEries 29 Hydrant valves installation, operation & maintenance manual

W A S T E W A T E R T R E A T M E N T S Y S T E M S

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

SPA WORLD. Pre- delivery Guide

FLANGES, TEES AND CROSSES, SPOOLS AND ADAPTERS. Sara Sae

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665

EPOXY FITTINGS DIMENSIONS

150 X 93 / 381 cm x cm* / cm* 1,489 US gallons / 5,635 Liters. 14,403lbs / 6,535 Kg lbs / 900 Kg. * +/- tolerance of 1/4

LASCO Schedule 40 PVC Fittings

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Office Use Only Fee Paid

Waterblade Installation Manual

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

SHEER DESCENT & WATERFALL SPILLWAYS

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg

Jet Swim Installation instruction

ROUND ASSEMBLY. Positioning

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

KlassikDrain Section K200/K300 ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

220 / 93 / 558 / 236 cm / cm US gallons / 9038 L. 22,948 lbs / 10,412 Kg lbs / 1374 Kg

Siting and Installation Manual

186 x 93 / 473 cm x cm / cm. 1,944 US gallons / 7,358 L. 18,677 lbs / 8,474 Kg. 2,460 lbs / 1,116 Kg

CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS

Table of Contents. We also carry a wide range of supplemental products for splash pad systems and pools.

Planning Backyard Vacations Everyday

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS

RESIDENTIAL SWIMMING POOL REQUIREMENTS


POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

210 x 93 / cm x cm / cm US gallons / 8259 Litres. 20,830 lbs / 9,451 Kg. 2,627 lbs / 1,192 Kg

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

WATERFALLS DECK JETS SCONCES. Waterfall, - Cut the waterfall notch in the inner edge of the bond beam at the stee tive cover nd protec a

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

*A Certificate of Survey for the property may be on file at City Hall if the house was built after 1984.

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage

Swimming Pool Permits are About Health and Safety

PAGE (Rev. A - 06/17)

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

NAVIGATOR Product demonstration prop building instructions

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg

6900 Professional Parkway East, Sarasota, FL Phone Fax Certificate of Authorization #43 FL Lic.

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

REQUEST FOR PROPOSAL FOR WATERPROOFING STRUCTURAL ENGINEERING

Halsey Taylor Owners Manual STOP!

FOAM FRACTIONATORS. Also Known As. Phoam Phraxtionators Protein Skimmers Air Strippers

RIVERFLOW PUMP INSTALLATION GUIDE

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS

PowerDrain Section S100K/S200K/S300K ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

RESIDENTIAL SWIMMING POOL

FOAM TANK (1/2) DATA SHEET

Installation Guide For Spillways & LED Light Bars

ARCHITECTURAL GUIDELINES 1000 S

ENDLESS POOLS FITNESS SYSTEMS. Product Announcement 50Hz May 2017

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

Transcription:

.0 1 TEE WITH () " RETURN NOZZLE 1 1.0 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE 2 LAZY RIVER PUMP LOCATION PUMP LOCATION PRELIMINARY SITE LAYOUT AND PUMP LOCATION 1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN) 2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY. ROTATE PUMP TEE TO MEET RETURN PIPE ANGLE. DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY.ROTATE 1 SUCTION 90 ELBOW AS NEEDED TO MEET SUCTION PIPING ANGLE. DIG ' WIDE X ' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE. PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING SYSTEM LAYOUT. 2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE.0 1.0.0 '-0" '-0" PRELIMINARY SYSTEM LAYOUT 1 OF

2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE.0 1.0.0 '-0" '-0" ON PG. 1 1 TEE WITH () " RETURN NOZZLE CLEARANCE FOR REMOVAL CLEARANCE FOR REMOVAL '-0" TO '-0" 10" 2 & ON PG. 6 1 SCH 0 PVC PIPE RETURN 1'- 1 2 " " '-0" TO '-0" 1'-" ON PG..0.0 1 SCH 0 PVC PIPE SUCTION LINE 6 1'- 1 2 " " 1 1 TEE WITH () " RETURN NOZZLES TO BE SET 10" BELOW WATER LINE TO RETURN 2 STRAIGHT RETURN PIPE WITH ACCELERATOR NOZZLE IS TO BE SET 10" BELOW WATER LINE TO OF PIPE ROTATE PUMP RETURN TEE AS NEEDED TO MEET RETURN PIPING ANGLE PLACE PUMP AND 90 SUCTION FITTING AT APPROPRIATE HEIGHT TO MEET RETURN PIPING ELEVATION. DRY FIT ALL PIPING FOR PROPER FIT AND ALIGNMENT BEFORE GLUEING IN PLACE. SUCTION PIPING TO 90 ELBOW IS TO BE PIPED USING ONLY FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS AS NEEDED. DRY FIT ALL PIPING FROM RETURN TO PUMP & FROM PUMP TO SUCTION BOXES BEFORE GLUEING IN PLACE. 6 POUR ' X ' X " THICK SLAB BELOW BOTTOM FLANGE FOR PUMP SUPPORT PAD. 2 10" OR 1 PIPE RETURN WITH ACCELERATOR NOZZLE 10 1 2 " CLEARANCE FOR REMOVAL 10 1 2 " CLEARANCE FOR REMOVAL '-6" TO '-0" 10" 10" OR 1 SCH 0 PVC PIPE RETURN " '-6" TO '-0" ON PG. 22. " 22. 1 SCH 0 PVC PIPE SUCTION LINE PIPING INSTALLATION 2 OF

DUAL SUCTION 12 X ON PG. GUNITE APPLICATION ACCLERATOR NOZZLE IN PIPE RIVERFLOW PUMP 1,, ON PG. 10 X ACCLERATOR NOZZLE IN PIPE 1 TEE WITH () " RETURNS VARIABLE SPEED DRIVE VARIABLE SPEED DRIVE COVER BACK 2,, ON PG. OF

1 2 OF

1 2 OF

WATER LINE RIVER BEAM 10" OR 1 SCH 0 RETURN PIPE MAXIMUM PUMP HEIGHT WITH OF BOTTOM FLANGE AT OR BELOW WATER LINE 1 SCH 0 SUCTION PIPE FROM MAIN DRAIN BOXES VERTICAL PUMP INSTALLATION SCALE N.T.S. CRITICAL NOTE: THIS SYSTEM IS A FLOODED SUCTION SYSTEM. TO MAINTAIN FLOODED SUCTION PUMP INSTALLATION MUST ADHERE TO MAXIMUM HEIGHT IN RELATION TO WATER LINE. VERTICAL INSTALLATION: PUMP FLANGE GASKET MUST MEET MAXIMUM HEIGHT AT WATER LINE OR LOWER. PIPE FITTINGS ARE REQUIRED TO MAINTAIN RETURN @ 10" BELOW WATER LEVEL. REFER TO SECTIONS AND PLANS FOR PUMP ELEVATION AND REQUIRED FITTINGS AS PER PROJECT APPLICATION. 6 OF

2'-0" PATIO OR DECK PATIO OR DECK T.B.D. " " " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE TO APPROVED SEWER OR FRENCH DRAIN 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW 2'-0" CAP / COPING STONES ABOVE GRADE MAXIMUM PUMP HEIGHT (WATER LINE AT OF BOTTOM FLANGE) " T.B.D. " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE " TO WASTE CAST IN PLACE CONCRETE PUMP BASE ALLOW CLEARANCE BETWEEN BOTTOM FOR FLANGE BOLT ACCESS. 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW CONCRETE PUMP BASE OF