.0 1 TEE WITH () " RETURN NOZZLE 1 1.0 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE 2 LAZY RIVER PUMP LOCATION PUMP LOCATION PRELIMINARY SITE LAYOUT AND PUMP LOCATION 1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN) 2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY. ROTATE PUMP TEE TO MEET RETURN PIPE ANGLE. DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY.ROTATE 1 SUCTION 90 ELBOW AS NEEDED TO MEET SUCTION PIPING ANGLE. DIG ' WIDE X ' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE. PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING SYSTEM LAYOUT. 2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE.0 1.0.0 '-0" '-0" PRELIMINARY SYSTEM LAYOUT 1 OF
2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE.0 1.0.0 '-0" '-0" ON PG. 1 1 TEE WITH () " RETURN NOZZLE CLEARANCE FOR REMOVAL CLEARANCE FOR REMOVAL '-0" TO '-0" 10" 2 & ON PG. 6 1 SCH 0 PVC PIPE RETURN 1'- 1 2 " " '-0" TO '-0" 1'-" ON PG..0.0 1 SCH 0 PVC PIPE SUCTION LINE 6 1'- 1 2 " " 1 1 TEE WITH () " RETURN NOZZLES TO BE SET 10" BELOW WATER LINE TO RETURN 2 STRAIGHT RETURN PIPE WITH ACCELERATOR NOZZLE IS TO BE SET 10" BELOW WATER LINE TO OF PIPE ROTATE PUMP RETURN TEE AS NEEDED TO MEET RETURN PIPING ANGLE PLACE PUMP AND 90 SUCTION FITTING AT APPROPRIATE HEIGHT TO MEET RETURN PIPING ELEVATION. DRY FIT ALL PIPING FOR PROPER FIT AND ALIGNMENT BEFORE GLUEING IN PLACE. SUCTION PIPING TO 90 ELBOW IS TO BE PIPED USING ONLY FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS AS NEEDED. DRY FIT ALL PIPING FROM RETURN TO PUMP & FROM PUMP TO SUCTION BOXES BEFORE GLUEING IN PLACE. 6 POUR ' X ' X " THICK SLAB BELOW BOTTOM FLANGE FOR PUMP SUPPORT PAD. 2 10" OR 1 PIPE RETURN WITH ACCELERATOR NOZZLE 10 1 2 " CLEARANCE FOR REMOVAL 10 1 2 " CLEARANCE FOR REMOVAL '-6" TO '-0" 10" 10" OR 1 SCH 0 PVC PIPE RETURN " '-6" TO '-0" ON PG. 22. " 22. 1 SCH 0 PVC PIPE SUCTION LINE PIPING INSTALLATION 2 OF
DUAL SUCTION 12 X ON PG. GUNITE APPLICATION ACCLERATOR NOZZLE IN PIPE RIVERFLOW PUMP 1,, ON PG. 10 X ACCLERATOR NOZZLE IN PIPE 1 TEE WITH () " RETURNS VARIABLE SPEED DRIVE VARIABLE SPEED DRIVE COVER BACK 2,, ON PG. OF
1 2 OF
1 2 OF
WATER LINE RIVER BEAM 10" OR 1 SCH 0 RETURN PIPE MAXIMUM PUMP HEIGHT WITH OF BOTTOM FLANGE AT OR BELOW WATER LINE 1 SCH 0 SUCTION PIPE FROM MAIN DRAIN BOXES VERTICAL PUMP INSTALLATION SCALE N.T.S. CRITICAL NOTE: THIS SYSTEM IS A FLOODED SUCTION SYSTEM. TO MAINTAIN FLOODED SUCTION PUMP INSTALLATION MUST ADHERE TO MAXIMUM HEIGHT IN RELATION TO WATER LINE. VERTICAL INSTALLATION: PUMP FLANGE GASKET MUST MEET MAXIMUM HEIGHT AT WATER LINE OR LOWER. PIPE FITTINGS ARE REQUIRED TO MAINTAIN RETURN @ 10" BELOW WATER LEVEL. REFER TO SECTIONS AND PLANS FOR PUMP ELEVATION AND REQUIRED FITTINGS AS PER PROJECT APPLICATION. 6 OF
2'-0" PATIO OR DECK PATIO OR DECK T.B.D. " " " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE TO APPROVED SEWER OR FRENCH DRAIN 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW 2'-0" CAP / COPING STONES ABOVE GRADE MAXIMUM PUMP HEIGHT (WATER LINE AT OF BOTTOM FLANGE) " T.B.D. " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE " TO WASTE CAST IN PLACE CONCRETE PUMP BASE ALLOW CLEARANCE BETWEEN BOTTOM FOR FLANGE BOLT ACCESS. 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW CONCRETE PUMP BASE OF