AUTOMATED PNEUMATIC TANKER HATCH

Similar documents
The Original Dome Valve Range

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

COMPRESSOR MANUAL. (888)

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

OWNER S TECHNICAL MANUAL

WHEATLEY Series 822/820 Swing Check Valve

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

PRP-Keto EZ Seal Systems:

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Innovative Pressure Testing Equipment

Related Products: Auto Drain Valve. Model/Specifications. Model

Powers Controls D Day-Night Thermostats

TURBINE SEAL: AXIAL TYPE DESIGN

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

Data Sheet Issue A

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

INTENDED USE TECHNICAL SPECIFICATIONS

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

MUD 1. Vent check valves. Instruction and maintenance manual.

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Inert Air (N2) Systems Manual

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes


22. Specialty Valves.

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Model PSI Compressor with 3-Gallon Air Tank 12VDC

2 in. 18 Gauge Brad Nailer. User manual

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

icreasepro Creaser Operators Manual

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

SEMEMI SQA Unit Code H2AX 04 Carrying out scheduled maintenance tasks on fluid power equipment

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

Suitability of Work Equipment

Float Operated Level Controllers

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

The Discussion of this exercise covers the following points:

INSTRUCTION MANUAL Kobelco Eagle Marine Water Lubricated Stern Tube Seals

PANACEA P200 STAINLESS STEEL USER MANUAL

1700ESL Kamvalok Coupler

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Pneumatic Outflow Control

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Vacutrans Instructions

TECHNICAL DATA. than the water inlet pressure to the concentrate

HDX HDAR HDXP HDBT HDPV HDSE

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

IMPERIAL CHEMICAL INDUSTRIES LIMITED PETROCHEMICALS DIVISION. SAFETY NEWSLETTER No 66

200 PSI COMPRESSORS - MODEL NUMBERS

Model: 43T. Bermad Pressure Relief Valve

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

TRADESMAN DRAINLAYER

100C Air Compressor Kit

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Unit 24: Applications of Pneumatics and Hydraulics

IMPORTANT SAFETY INSTRUCTIONS

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Eliminating Fatal Risks. Dale Bradford Drilling Superintendent

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

SKYBOX USER GUIDE EMERGENCY ULTRAFILTRATION PACKAGE. The trusted choice for rapid response potable water solu4ons SKYBOX

TRADE AREA: ELECTRICAL INDUSTRY

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

ACCU-PULSE Installation and Operation Instructions

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

The Protection of Silos From Over. Pressurisation During Filling

Safety Powder Spray Systems

TROUBLESHOOTING GUIDELINES

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Instructions for Installation, Operation, Care and Maintenance

Farm Chlor Chlorinator Instruction Manual

Compliance Is the First Step on the Safety Ladder Understanding the final walking-working surface rule from OSHA and how Honeywell ladder solutions

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

POOL ROVER ST POOL CLEANER Installation Instructions

Transcription:

AUTOMATED PNEUMATIC TANKER HATCH http://hmtechno.com/our-products/pivotal-edge/

Pivotal Edge Automated manhole cover for pneumatic tankers Pivotal Edge have developed automated hatches that operate remotely, significantly reducing the risk of driver and operator injury whilst improving efficiency in particular truck turn around time. Manually opening your covers wastes valuable time and puts your drivers at risk. Pivotal Edge is Fast Pivotal Edge works remotely, so drivers can open the tank covers from the safety of the ground or even the cab, saving time and ensuring safety. With Pivotal Edge, there s no climbing, so you can cut load time and injury rates. It reduces the physical demands on your drivers, keeping your valuable drivers on the road. Improved turnaround rates while loading will ensure better fleet utilization and contribute to improved customer service. Pivotal Edge is Tough Pivotal Edge is field-tested tough. The people who designed Pivotal Edge are also the people who use it. No matter the weather conditions or situation, Pivotal Edge has passed every real world test it's been subjected to, and by keeping moving parts to a minimum, maintenance and service is kept to a minimum too! Pivotal Edge is Easy The Pivotal Edge Manhole cover is easy to install, the light-weight aluminum construction does not require any structural modifications to be installed on your trailers. Units can easily be retrofitted on existing equipment or installed on your new trailers and tankers. Pivotal Edge have developed a 24 " Rail Hatch adaptor. Pivotal Edge is Safe Pivotal edge improves workplace health and safety, as drivers open tank covers from the safety of the ground therefore minimising the risk of potentially serious and permanent injury by reducing the risks associated with manual handling tasks and trip, slip and fall hazards from height. How does it work Once the cover reaches the closed proximity switch it will be securely latched into the six cast hold downs. The pneumatic seal is inflated to 275 Kpa using regulated and filtered truck air.

Fast Productivity improvements Faster and easier access, Driver stays in the cab or on the ground reducing time required to climb up onto the tanker or up to a platform and manually open and close hatch for each load. Faster turn around time potential time saving of 10 minutes per load, depending on loading operation configuration. With increase traffic pressure and time taken to complete a load all of which can influence the earning potential of a truck, all time savings have a direct dollar benefit. Faster pumping out, the units are rated to be pressurized up to 2.5 bar allowing for safe but faster discharging of loads improving truck or rail wagon turnaround. Faster cleaning of manhole, the air knife functionality makes sure the manhole lip is cleaned on sealing ensuring low wear on seal and improving sealing reliability. Easy Easy to install and operate Easy to access control box fitted to truck or in the cab, unit is operated from the safety of the ground with single button control Easy confirmation that the hatch and vessel are sealed, an open close indicator light on the control box confirms the hatch is sealed and the load is ready for transport. Easy resealing from the ground, purge functionality ensure the unit can be resealed if it loses charge for any reason. Easy and quick installation of manhole cover, the lightweight aluminum construction does not require any structural modifications to be installed on your trailers. Units can easily be retrofitted on existing equipment or installed on your new trailers and tankers. Pivotal Edge have developed a 24 " Rail Hatch adaptor. Tough Low maintenance cost Low maintenance, keeping moving parts to a minimum ensures maintenance and service is kept to a minimum. Low maintenance and easy replacement of parts means there is little need for highly specialized maintenance crews making it easy to fit into the regular service maintenance schedules. Low risk of failure out on the road, built in functionalities like the air knife to keep the unit clean, the open close indicator on the control box and the ability to purge and reseal, reduce the risk of encountering problems on the road. Low replacement rate on Seals, seal contracts whilst the unit is opening, in standby and closing ensuring wear on the seal is minimized due to abrasion and friction. Simulated factory testing demonstrates a seal life in excess of 100 000 cycles is achievable. Safe Reduces workplace health and safety risks Reduces the Manual tasks of opening and closing hatches, as Pivotal Edge hatch opens automatically there is no requirement for the driver to bend down, unfasten and lift hatches. Reduces the working at height risks, as the Pivotal Edge hatch opens automatically from a control at ground level, there is no need for drivers to climb onto a tanker. Reduces trip and fall risks, as the Pivotal Edge hatch opens automatically from a control at ground level, there is almost no need to climb up and down ladders and stairs and walk on top of tankers. Reduces Slip hazards, as the Pivotal Edge hatch opens automatically from a control at ground level there is no need for a driver to walk on top of a taker. Fast Tough Easy Safe Seal life expectancy is significantly Reduced if installation of unit has not Been carried out correctly. If you are Seeing lower than expected seal life call HM for some trouble shooting advice. In busy metro areas drives may be required to do this task 6 and 8 times per day. Some transport companies can attribute 2 to 3 FTI s per month and possibly 6 to 10 MTI s and LTI s per annum to the performance of this task. In the past climbing onto takers has caused serious and permanent injuries. Busy drives in metro regions may be required to climb up and down a ladder or stairs 6 to 8 times per day. This is a high risk activity as the top can be wet, icy or dusty with potentially hazardous powders near the hatches. This environment can easily lead to serious slips and falls even if safety rails are in place.

Design features that set the Pivotal Edge apart from the market: Easy and quick installation of manhole cover, the light-weight aluminum construction does not require any structural modifications to be installed on your trailers. Units can easily be retrofitted on existing equipment or installed on your new trailers and tankers. Easy installation there is no welding required for installation and the Pivotal Edge is compatible with most 20 " manholes and has an adaptor for 18 " manholes. Easy to adapt the Pivotal Edge have developed a 24 " Rail Hatch adaptor, to ensure easy installation of hatches onto rail tanks. Low replacement rate on Seals, the seal contracts whilst the unit is opening, in standby and closing ensuring wear on the seal is minimized due to abrasion and friction. Simulated testing demonstrates a seal life of 140 000 cycles is achievable. Faster cleaning of manhole, the air knife functionality makes sure the manhole lip is cleaned on sealing thereby ensuring low wear on seal and improving sealing reliability. Tough design the pivotal has a hinge pin assembly that has no bearings to clog up and or seize Faster pumping out, the units are rated to be pressurized up to 2.5 bar allowing for safe but faster discharging of loads improving truck or rail wagon turnaround. Easy resealing from the ground, purge functionality ensure the unit can be resealed if it loses charge for any reason. Easy confirmation that the hatch and vessel are sealed, an open close indicator light on the control box confirms the hatch is sealed and the load is ready for transport. Tough inflatable gasket maintains a positive seal

Pivotal Edge FAQ s How does the seal work? Once the cover reaches the closed proximity switch it will be securely latched into the six cast hold downs. The pneumatic seal is inflated to 40 psi for a typical road tanker using regulated and filtered truck air. What pressure has the cover been tested to? Static testing to 65 psi has been done. How often does the cover need service? The cover is designed to require minimal maintenance item that need to be watched are: Excessive hardened product buildup. Air leaks around the seal. Binding of components Check for abrasions on air lines What is the certified operating pressure of a Pivotal Edge hatch? The typical operating pressure for road tankers is 2 bar and for rail tankers its 2.5 bar, the Pivotal Edge hatches are therefore certified to operate to 2.5bar. What is the expected life cycle of the hatch seal? Automated factory trials indicate 140 000 cycles was achievable. How do I know the hatch is sealed? There is an indicator light on the control box which confirms the hatch and unit are sealed. What if the seal leaks If the inflatable seal develops a leak it can be replace by removing the top cover. This should be done in a safety cage. Replacement should only take a few minutes. The seal requires no adhesives to hold it into place. Will the seal leak while I am driving in the rain? The top cover has been designed to channel the water to drain on the outside of the latches. Also the seal is only deflated when the cover is open. A check valve will maintain the pressure in the seal even when the trailer air is released or drained. What will it take to install the pivotal edge? They are easy to install. No specialty tools are required. Takes between two to four man hours to install. What happens if someone tries to open the cover when the tank is pressurized? There will be lots of dust and noise, but no damage to the cover. What temperature is the seal rated for? -40º C to 65º C Why would you build this Jay and Brad both work in the industry and saw the need to protect the drivers from the risks involved. Drivers on the trailers and driver fatigue of climbing the ladders or up the existing fall protection stairs. Every load has the risk of two trips or falls.

PIVOTAL EDGE