Direct solenoid and solenoid pilot operated valves

Similar documents
Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8

Section 2 Proportional Quick Exhaust

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

VSD03M DIRECTIONAL CONTROL VALVES

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

4/2 way Pneumatic Solenoid Valve

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pneumatic spool valve islands

Nugget 120 V14 Series

SOLENOID VALVES AND PNEUMATIC VALVES

Nugget 120 V14 Series

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Proportional Throttle Cartridges, Size 16

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

SPCH/ Blowing block

PVQ 13 A2 R SE 1 S 20 C-11 D

3-Way Safety Block DSV

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

TECHNICAL CHARACTERSTICS

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

HEAVY DUTY PNEUMATIC

Intrinsically safe solenoid valves on/off controls - ATEX certification

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Pneumatic valve islands

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Inverse Proportional Pressure-Relief Cartridge, Size 10

SITRANS P measuring instruments for pressure

BGC258 Series BASOTROL Gas Valve

SDM to 8 sections monoblock valve D1WWDA02A

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

W60 Spool & Sleeve Valves for ISO Bases (5599/I)

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Hand lever valves VHER

Dual Solenoid Gas Valve Installation

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Valves to ISO 5599/1 standards pilot and solenoid actuated size

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

[Instruments for vacuum measurement, checking and adjustment] 3

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Gas Pressure Switch for DMV safety shutoff valves

SPECIFICATIONS ATTENTION

INSTALLATION & MAINTENANCE INSTRUCTIONS

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Smooth Vent Valve. XVD Series

series UDS ISO to ISO 5599/1 standard pilot and solenoid actuated sizes DESCRIPTION TECHNICAL DATA MATERIALS SPARE PARTS

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Directional Controls

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Inverse Proportional Pressure-Relief Cart., Size 2 4

VALVES ISO 5599/1, SERIES IPV-ISV

Proportional Relief Valves

seriesuds ISO Valves to ISO 5599/1 standard

Smooth Vent Valve XVD. Series

GM-7000 Series CE Approved Gas Control Valve

Dynisco SPX Industrial (2280/2281) Series

Electrically Operated Pressure-Relief Cartridge, Size 10

Propor tional Re lief Valve s

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Gas Pressure Switch for DMV safety shutoff valves

QBS Electronic Pressure Regulator

Solenoid valves VZWF, force pilot operated

Proportional Pressure-Relief Cartridge Valve, Size 2...4

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

AT SERIES. Dart Valve Actuator. Thrusts up to 55,000 lbs SIL-3 Capable GT3 Triple Seal Gland for Severe Service Applications

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Proportional Pressure-Relief Cartridge Valve, Size 2...4

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

TWO POST RAM PACKAGE 55 GALLON

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

GM-7000 Series CE Approved Gas Control Valve

Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure Switch for gas and air

BGA158 Series CE Approved Class A Shutoff Gas Valve

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Trimpac 244a. September 16, 2013

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Valve Proving System VDK 200 A S02

Safety and Shut-off Block SAF/DSV

Solenoid Valves VUVG Overview

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Gas Pressure Switch for DMV safety shutoff valves

Transcription:

Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/2 Manifold mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/2 Series 4 6 2 Bonded spool Balanced 4-way poppet Internal pilot supply Manual operator Large spool diameter External pilot supply 7 8 2 67 69 44 46 Air return 42 47 48P External pilot supply 2 4 48 400 92 SERIES FEATURES Plug-in (99/2) and non plug-in (99/) models. 2-position, single or double operator. (Solenoid or Remote Air) -position, double solenoid, open center, closed center, and pressure center. Extended or recessed manual operators. Single pressure and dual pressure. Individual base or add-a-unit manifold base. Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves. 9 ISO 0 ISO 02 ISO ISO 2 ISO 9 Consult Precautions page 27 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series, / /2 - /4 6. C v No base non plug-in Valve only Conform to ISO 99/ OPERATIONAL BENEFITS. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation. 2. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure.. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "2" end DUAL PRESSURE MODELS Pilot air Single operator MV-BA-AAAA-DM-DXXX-XXX MV-BA-AAAB-DM-DXXX-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to.0 watt. Double operator MV-BA-ABAA-DM-DXXX-XXX MV-BA-ABAB-DM-DXXX-XXX Single operator / Closed center MV-BA-AEAA-DM-DXXX-XXX MV-BA-AEAB-DM-DXXX-XXX Double operator / Open center MV-BA-AFAA-DM-DXXX-XXX MV-BA-AFAB-DM-DXXX-XXX / Pressure center 4 6 2 7 8 2 67 69 44 46 42 47 48P Internal pilot From port # MV-BA-ACAD-DM-DXXX-XXX MV-BA-ADAD-DM-DXXX-XXX 4 2 MV-BA-AGAD-DM-DXXX-XXX 48 Internal pilot From port # External pilot From "2" end MV-BA-ACAE-DM-DXXX-XXX MV-BA-ACAB-DM-DXXX-XXX MV-BA-ADAE-DM-DXXX-XXX MV-BA-ADAB-DM-DXXX-XXX MV-BA-AGAE-DM-DXXX-XXX MV-BA-AGAB-DM-DXXX-XXX 400 SOLENOID OPERATOR DM-D XXX-XXX * 92 XX Voltage X Lead wire length X Manual operator XX JA 0/0, 20/60 A 8 (Flying leads) Non-locking recessed KA JB 220/0, 240/60 B 24 (Flying leads) 2 Locking recessed KD JC 24/0, 24/60 J Connector JB FB 24 VDC (.8W) JD DA 24 VDC (.4W) BA DF 24 VDC (2.7W) * Other options available, see page 09. Note: ISO series, valve and base are ordered separately, see page 29 for base code. OPTIONS Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 9 ISO 0 ISO 02 ISO ISO 2 ISO Valve function : MV-BA-AXXX-XX-DXXX-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-BA-AXXX-DM-DXXX-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#0-2) Spool return : MV-BA-AXAX-XX-DXXX-XXX A Standard return B Memory spring return 9 Consult Precautions page 27 before use, installation or service of MAC Valves..

4 2 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (.4 W coil) Compressed air, vacuum, inert gases Internal pilot: 20 to 20 PSI External pilot : vacuum to 20 PSI Single/double operator : 20 to 20 PSI, positions : 0 to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C) /2": (.4 C v ) /4": (6. C v ) Class A continuous duty, #22 AWG leads -% to +0% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 2.7 to.0 W Energize : 6.2 ms De-energize :.6 ms Options : Sandwich regulator, see Regulators section Spare parts : Pilot valve: DMB-Dxxx-xxx Valve to base pressure seal: 664 Valve mounting screws (x4): 4 DIMENSIONS Individual base DOUBLE SOLENOID W/ 90.4 EXTENDED OVERRIDE SINGLE SOLENOID W/ 7.0 EXTENDED OVERRIDE 60.0 Dimensions shown are metric (mm) Manifold base 26. P 2.0 2 2 4 77,9 0.0 40.0 9.0 9.9 WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 20 PSI MODIF. 44. 2. 29.0 4 2 7. 78.0 77.0 98. 26.0 27.0 27.0.0 8. DIA. THRU 4 MTG. HOLES 8. 6.8 48.8 2.8 COND 0.2 96.0 40.0 62.0 7.2 88.9 22. 60.8 6. 47.0 48.0 27.8 7. 7. 28.0 66. 64.0 8. 24. 4..4 27.0 8.2 DIA. THRU 2 MTG HOLES 6.4 99.9 2.8 9.0 9.0 4 2 OPTIONAL BTM PORTS 78.0.0 9.0 7.0 9. 94. 40.0 208.0 9.0.7 94 Consult Precautions page 27 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series, / /2 - /4 6. C v No base plug-in Valve only Conform to ISO 99/2 OPERATIONAL BENEFITS. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation. 2. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure.. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "2" end DUAL PRESSURE MODELS Pilot air Single operator MV-PA-AAAA-DM-DXXP-XXX MV-PA-AAAB-DM-DXXP-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to.0 watt. Double operator MV-PA-ABAA-DM-DXXP-XXX MV-PA-ABAB-DM-DXXP-XXX Single operator / Closed center MV-PA-AEAA-DM-DXXP-XXX MV-PA-AEAB-DM-DXXP-XXX Double operator / Open center MV-PA-AFAA-DM-DXXP-XXX MV-PA-AFAB-DM-DXXP-XXX / Pressure center 4 6 2 7 8 2 67 69 44 46 42 47 48P Internal pilot From port # MV-PA-ACAD-DM-DXXP-XXX MV-PA-ADAD-DM-DXXP-XXX 4 2 MV-PA-AGAD-DM-DXXP-XXX 48 Internal pilot From port # External pilot From "2" end MV-PA-ACAE-DM-DXXP-XXX MV-PA-ACAB-DM-DXXP-XXX MV-PA-ADAE-DM-DXXP-XXX MV-PA-ADAB-DM-DXXP-XXX MV-PA-AGAE-DM-DXXP-XXX MV-PA-AGAB-DM-DXXP-XXX 400 SOLENOID OPERATOR DM-D XX P-XXX * 92 XX Voltage X Manual operator XX JA JB JC FB DA DF 0/0, 20/60 (2.9W) 220/0, 240/60 (2.9W) 24/0, 24/60 (2.9W) 24 VDC (.8W) 24 VDC (.4W) 24 VDC (2.7W) * Other options available, see page 09. Note: - ISO series, valve and base are ordered separately, see page 24 for base codes. - Ground wire required for 0 volts or higher. OPTIONS Non-locking recessed 2 Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 9 ISO 0 ISO 02 ISO ISO 2 ISO Valve function : MV-PA-AXXX-XX-DXXP-XXX Pilot style : MV-PA-AXXX-DM-DXXP-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) DM Pilot exhaust muffled DP Pilot exhaust piped (#0-2) Spool return : MV-PA-AXAX-XX-DXXP-XXX A Standard return B Memory spring return D Standard return with light E Memory spring return with light 9 Consult Precautions page 27 before use, installation or service of MAC Valves..

4 2 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (.4 W coil) Compressed air, vacuum, inert gases Internal pilot: 20 to 20 PSI External pilot : vacuum to 20 PSI Single/double operator : 20 to 20 PSI, positions : 0 to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C) /2": (.4 C v ) /4": (6. C v ) Class A continuous duty, #22 AWG leads -% to +0% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 2.7 to.0 W Energize : 6.2 ms De-energize :.6 ms Options : Sandwich regulator, see Regulators section Spare parts : Pilot valve: DMB-DxxP-xxx Valve to base pressure seal: 664 Valve mounting screws (x4): 4 DIMENSIONS Individual base Manifold base 26. Dimensions shown are metric (mm) WIXOM,MI. USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 20 PSI 2 P 77,9 0.0 2.0 2 4 9.4 40.0 9.9 9.0 MODIF. 29.0 2. 28. WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL WATTS ELECTRICAL VAC TO 20 PSI.0 48. 60.8 69.0 89. 06. 42.0 9.0 6.8 48.8 2.8 COND 6. 47.0 48.0 27.8 8.2 DIA THRU 2 MTG HOLES 66. 07.0 69.0.0 24. 88.9 22. 40.0 7.2 96.0 62.0 0.2 7. 69. 4. 8. 4 2 4 2 62.0 79.0.4 27.0 8.2 DIA. THRU 2 MTG HOLES 6.4 99.9 2.8 9.0 9.0 8.0 24.0 78.0.0 9.0 4.0 86.. 208.0 9.0.7 96 Consult Precautions page 27 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series / /2" /4" 6.2 C v Valve only no base OPERATIONAL BENEFITS. Balanced spool, immune to variations of pressure. 2. Powerful return forces thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking.. Long service life. 400 67 69 ISO 2 ISO HOW TO ORDER SINGLE PRESSURE MODELS Air spring Single operator Double operator / Closed center / Open center Internal External MV-RA-BACF MV-RA-BACG MV-RA-BBAK MV-RA-BEAK MV-RA-BFAK DUAL PRESSURE MODELS Air spring Single operator Double operator / Pressure center Internal port # MV-RA-BCCH Internal port # MV-RA-BCCJ MV-RA-BDAK MV-RA-BGAK External MV-RA-BCCG Note: ISO series, valve and base are ordered separately, see page 29 for base code. 22 Consult Precautions page 27 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Function Port size Flow (Max) Individual mounting Series - / /2" - /4" 6. C v valve only operational benefits. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow.. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. how to order Single pressure valves 00 6 7 8 9 Air spring Single operator Double operator / Closed center / Open center 700 Internal MV-AB-B ----- ----- ----- 900 External MV-AB-B2 MV-AB-B22 MV-AB-B22 MV-AB-B2 Dual pressure valves 82 Air spring Single operator Double operator / Pressure center 600 Internal port MV-AB-B ----- ----- 600 Internal port External MV-AB-B MV-AB-B4 ----- MV-AB-B24 ----- MV-AB-B4 6600 Note : ISO valves are delivered w/o base. See page 28 for base code. 2700 800 ISO ISO 2 ISO 26 Consult Precautions page 64 before use, installation or service of MAC Valves

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% M O N T H S Series ISO technical data Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 0 PSI Single operator and positions : 2 to 0 PSI main valve pressure Double operator : 0 to 0 PSI Not required, if used select a medium aniline point lubricant (between 80 F to 20 F) 40 µ 0 F to 20 F (-8 C to 0 C) /2" - /4 : (6. C v ) 200 cm /min Spare parts : Remote air operator : R-A004. Pressure seal between valve and base : 646. Mounting screw body to base (x4) : 46. dimensions Dimensions shown are metric (mm) 2 4 24,4 46,0,0 27,0 4,0 2 4 20, 20, 49,0 49,0 4,0 40,0 22,0 4,,0,0 7,,0 70,0 Ø 8, -4 MTG. HOLES /8 REMOTE PILOT 68,0 2,0 2 4 9, 64,0 2,0 79,0,0 49,0 49,0 78,0 6,0 OPTIONAL BOTTOM PORTS 266 Consult Precautions page 64 before use, installation or service of MAC Valves

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Compressed air, vacuum, inert gases Vacuum to 0 PSI Single/double operator: 20 to 0 PSI position: 0 to 0 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to 0 C) /2" : (.4 C v ) - /4" : (6.2 C v ) Spare parts : Valve to base pressure seal: 664 Valve mounting screws (x4): 4 DIMENSIONS Dimensions shown are metric (mm) MODIF. WIXOM,MI USA LIEGE,BELGIUM AUCKLAND,N.J. ISO 99/2 6.4 MODEL VAC TO 0 PSI 60.0 6.8 222 Consult Precautions page 27 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 9 9 / Series ISO Series Non plug-in base / manifold ISO 0 ISO 02 ISO ISO 2 ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom inlet port /2 NPTF MB-AB-22 MB-AB-22 MB-AB-222 MB-AB-224 /4 NPTF MB-AB-2 MB-AB-2 MB-AB-22 MB-AB-24 MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom inlet port /2 NPTF MM-BA-22-A MM-BA-22-A MM-BA-222-A MM-BA-224-A /4 NPTF MM-BA-2-A MM-BA-2-A MM-BA-22-A MM-BA-24-A Manifold fastening kit: N-P00-0. Valve blanking plate: M-P00. Inlet/exhaust isolator plug: 284. Individual Base Options: MB-AB-XXXF Optional Integral Flow Controls 29 Consult Precautions page 27 before use, installation or service of MAC Valves..

4 2 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual ISO DIN 99/ 40,0,0 70,0 Ø 8, 4 MTG. HOLES,0 7, 46,0,0 27,0 4,0 49,0 /8 EXTERNAL PILOT/ REMOTE AIR PILOT PORT (2 PLACES) 2,0 2 4 2 2 4 20, 20, 49,0 4,0 22,0 4,,0 64,0 2,0,0 4 49,0 49,0 78,0 6,0 9, 79,0 OPTIONAL BOTTOM PORTS Manifold 26. 2 2.0 P 2 4 0.0 77,9 40.0 9.0 8.2 DIA. THRU 2 MTG HOLES 6.4 99.9 2.8.4 27.0 9.0 9.0 6.8 48.8 2.8 COND 27.8 47.0 48.0 6. 78.0.0 9.0 88.9 22. 96.0 40.0 62.0 7.2 0.2 7. 208.0 9.0.7 240 Consult Precautions page 27 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 9 9 / Series ISO Series Plug-in manifold ISO 0 ISO 02 ISO ISO 2 ISO HOW TO ORDER MANIFOLD BASE Port size Wired for Side ports Side ports w/ bottom 2 & 4 ports All side & bottom ports (see note) /2 NPTF Single solenoid Double solenoid MM-PA-22-A MM-PA-22-B MM-PA-222-A MM-PA-222-B MM-PA-22-A MM-PA-22-B /4 NPTF Single solenoid Double solenoid MM-PA-2-A MM-PA-2-B MM-PA-22-A MM-PA-22-B MM-PA-2-A MM-PA-2-B Note : Ports, & are always /4 OPTIONS Manifold options : External pilot MM-PA-22X-X 2 for /2" port common external pilot 26 for /4" port common external pilot Terminal strip MM-PA-XXX-A J K wired for sgl solenoid wired for double solenoid light(s) MM-PA-XXX-XJA JA JB DA 0/20 volt 220/240 volt 24 volt Accessories: M-P00 Valve blanking plate. N-P00-0 Manifold fastening kit. 284 Inlet/exhaust isolator plug. 24 Consult Precautions page 27 before use, installation or service of MAC Valves..

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) WIXOM,MI. USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 20 PSI 9.4 29.0 2. 28..0 48. 69.0 89. 06. 9.0 42.0 8.2 DIA THRU 2 MTG HOLES 66. 07.0 69.0.0 69. 8. 24. 4. 4 2 4 2 62.0 79.0 8.0 24.0 86.. 4.0 242 Consult Precautions page 27 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 9 9 Series ISO Series ISO ISO 2 ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Side & bottom ports Bottom cylinder ports 2 and 4. Bottom inlet port /2 NPTF MB-AB-22 MB-AB-22 MB-AB-222 MB-AB-224 /4 NPTF MB-AB-2 MB-AB-2 MB-AB-22 MB-AB-24 289 Consult Precautions page 64 before use, installation or service of MAC Valves

00% 00% WARRANTY 8 OF PRODUCTION TESTED 00% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual ISO DIN 99/,0 40,0,0 7, 70,0 Ø 8, 4 MTG. HOLES 46,0,0 27,0 /8 EXTERNAL PILOT 2,0 2 4 2 4 64,0 2 4 4,,0 22,0 4,0 4,0 20, 20, 49,0 49,0 2,0,0 49,0 49,0 78,0 6,0 9, 79,0 OPTIONAL BOTTOM PORTS 290 Consult Precautions page 64 before use, installation or service of MAC Valves

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX 2 4 - Pilot operated valves 2, 67, 92, 9, 400, ISO, ISO2, ISO Series OPTIONS AVAILABLE FOR 09 Consult Precautions page 27 before use, installation or service of MAC Valves..

OPTIONS. VOLTAGE D-XX X-X XX VOLTAGE DA 24 VDC (.4W) DB 2 VDC (.4W) DC 2 VDC (7.W) DD 24 VDC (7.W) DE 2 VDC (2.7W) DF 24 VDC (2.7W) DK 0 VDC (4.7W) DJ 28 VDC (.2W) DL 64 VDC (6.0W) DM 6 VDC (.W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 0 VDC (7.W) DT 7 VDC (.6W) DP 48 VDC (.8W) FA 2 VDC (.8W) FB 24 VDC (.8W) FE 2 VDC (2.4W) FF 24 VDC (2.4W) JA 20/60, 0/0 (2.9W) JB 240/60, 220/0 (2.9W) JC 24/60, 24/0 (.7W) JD 00/60, 00/0, 0/60 (.9W) JE 220/60 (.4W) JF 240/0 (2.8W) JG 200/60, 200/0 (.9W) 2. WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 8" B 24" C 6" D 48" E 72" F 96" 4. ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* /2" NPS conduit with flying leads CM* /2" NPS metal conduit with flying leads CN* /2" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 0 volts, a ground wire is required. Applies to options with flying leads.. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator Non-locking recessed 2 Locking recessed Non-locking extended 4 Locking extended 0 Consult Precautions page 27 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Function Port size Flow (Max) Individual mounting Series - / /2" - /4" 6. C v valve only OPERATIONAL BENEFITS. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow.. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER SINGLE PRESSURE VALVES 00 6 7 8 9 Air spring Single operator Double operator / Closed center / Open center 700 Internal MV-AB-B ----- ----- ----- 900 External MV-AB-B2 MV-AB-B22 MV-AB-B22 MV-AB-B2 DUAL PRESSURE VALVES 82 Air spring Single operator Double operator / Pressure center 600 Internal port MV-AB-B ----- ----- 600 Internal port External MV-AB-B MV-AB-B4 ----- MV-AB-B24 ----- MV-AB-B4 6600 Note : ISO valves are delivered w/o base. See page 27 for base code. 2700 800 ISO ISO 2 ISO 27 Consult Precautions page 6 before use, installation or service of MAC Valves.

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, ΔP=bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 0 PSI Single operator and positions : 2 to 0 PSI main valve pressure Double operator : 0 to 0 PSI Not required, if used select a medium aniline point lubricant (between 80 F to 20 F) 40 µ 0 F to 20 F (-8 C to 0 C) /2" - /4 : (6. C v ) 00 cm /min Spare parts : Remote air operator : R-A004. Pressure seal between valve and base : 646. Mounting screw body to base (x4) : 46. DIMENSIONS Dimensions shown are metric (mm) 2 4 24,4 46,0,0 27,0 /8 REMOTE PILOT 4,0 2 4 20, 20, 49,0 49,0 68,0 4,0 40,0 22,0 4,,0,0 7,,0 2,0 2 4 64,0 2,0 70,0 Ø 8, -4 MTG. HOLES 9, 79,0,0 49,0 49,0 78,0 6,0 OPTIONAL BOTTOM PORTS 28 Consult Precautions page 6 before use, installation or service of MAC Valves.

D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s Series ISO Individual mounting Series valve only Manifold mounting valve only 00 Air/spring return External pilot port Bonded flow seal spool Pilot air accumulator Manual operator 200 6 7 8 9 4 2 4 700 900 82 series features Fastest available response time with patented Macsolenoid. No-stick operation is ensured by wiping action of unique MAC spool/bore combination. Balanced poppet pilot valve for high flow, precise repeatability, and consistent operation. Large spool piston for high shifting force even at minimum operating pressure Air/spring return for consistent shifting on single solenoid models. Patented virtually burn-out proof AC solenoid. Optional low wattage DC solenoids down to.0 watt. Various manual operators & electrical connectors are available. Muffled or threaded pilot exhaust ports. Internal of external pilot models available. 6 Consult Precautions page 64 before use, installation or service of MAC Valves 600 600 6600 00 800 ISO ISO 2 ISO MAC 2A MAC 20A MAC 00A

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% M O N T H S Series ISO VALVE CONFIGURATIONS AVAILABLE 2-Pos., single or double operators (solenoid or remote air). Single or dual pressure. -Pos., double operator-closed center, open center or pressure center (solenoid or remote air). Individual base. Internal pilot or external pilot (including a common external pilot or manifold models). Side porting and bottom porting options. *International Standards Organization ISO Common Base Interface (ISO Std. 99/) SPECIAL APPLICATION INSTRUCTIONS : On all models, energizing the "4" operator (solenoid or remote air) connects Port # to Cylinder Port #4 and energizing the "2" operator connects Port # to Cylinder Port #2. For the following special applications, additional piping considerations are required. EXTERNAL PILOT APPLICATIONS* - An External Pilot Supply is only required when the main valve pressure is less than.8 BARS on single operators (soleneoid or remote air) or 0.7 BARS on double solenoid valves only. In these cases, use an External Pilot model and supply a minimum of.8 BARS for single operators or a minimum of 0.7 BARS for double solenoid valves to either the "4" or "2" External Pilot Port of the valve base. VACUUM APPLICATIONS - Use an External Pilot model as described above and also connect the vacuum source to Port # & and leave Port# open to atmosphere on single pressure models. On two pressure models, reverse the single pressure piping. SELECTOR APPLICATIONS - Use an External Pilot Model as described above if both pressures are below the minimum, otherwise use an Internal Pilot model and connect the higher pressure to Port # and the lower pressure to either Port # or depending on which Cylinder Port is to be active. TWO PRESSURE APPLICATIONS - For Internal Pilot models specify the model number for connecting either port # or, whichever is to be the higher pressure, to the Internal Pilot supply. For external Pilot models, pipe as described above for "External Pilot Application." *Note: Bar = 4. PSIG 66 Consult Precautions page 64 before use, installation or service of MAC Valves

D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s Series ISO Function Port size Flow (Max) Individual mounting & Manifold mounting Series - / /2 - /4 6. C v valve only operational benefits. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow.. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. how to order Single pressure valves Pilot air Single operator Double operator / Closed center / Open center 00 200 6 7 8 9 Internal External MV-AB-A-PM-XXYZZ MV-AB-A2-PM-XXYZZ MV-AB-A2-PM-XXYZZ MV-AB-A22-PM-XXYZZ MV-AB-A2-PM-XXYZZ MV-AB-A22-PM-XXYZZ MV-AB-A-PM-XXYZZ MV-AB-A2-PM-XXYZZ 4 Dual pressure valves Pilot air Single operator Double operator / Pressure center 4 2 700 o p t i o n s Internal port Internal port External SOLENOID OPERATOR MV-AB-A-PM-XXYZZ MV-AB-A-PM-XXYZZ MV-AB-A4-PM-XXYZZ XX Y ZZ * 67 MV-AB-A2-PM-XXYZZ MV-AB-A22-PM-XXYZZ MV-AB-A24-PM-XXYZZ MV-AB-A-PM-XXYZZ - For CNOMO pilot, consult factory. - For universal spool replace by 6 (2 position, sgl. pressure valves only) - For use with single pressure sandwich regulator, replace by. MV-AB-A-PM-XXYZZ MV-AB-A2-PM-XXYZZ MV-AB-A4-PM-XXYZZ XX Voltage Y Manual operator ZZ Electrical connection 20/60, 0/0 Non-locking JB Rectangular connector 2 240/60, 220/0 2 Locking JD Rectangular connector with light 22 24/60, 24/0 JA Square connector 9 24 VDC (2. W) JC Square connector with light 87 24 VDC (7. W) BA Flying leads (8 ) 6 24 VDC (8. W) Note : Photo shown with JC connector. * Other options available, see page 7. Note : ISO valves are delivered w/o base. See page 28 for base code. Consult Precautions page 64 before use, installation or service of MAC Valves 900 82 600 600 6600 00 800 ISO ISO 2 ISO MAC 2A MAC 20A MAC 00A

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% M O N T H S Series ISO technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and positions : 2-0 PSI double operator : 0-0 PSI External pilot : vacuum to 0 PSI Single operator and positions : 2-0 PSI Double operator : 0-0 PSI Not required, if used select a medium aniline point lubricant (between 80 F to 20 F) 40 µ 0 F to 20 F (-8 C to 0 C) /2" : (6. C v ), /4" : (6. C v ) 200 cm /min Epoxy encapsulated - class A wires - Continuous duty -% to +0% of nominal voltage Consult factory Inrush : 4.8 VA Holding : 0.9 VA = to 7. W 24 VDC (8. W) Energize : 8 ms De-energize : 20 ms 20/60 Energize : -2 ms De-energize : 9-28 ms Spare parts : Solenoid operator (power 4 W) : D-XXAA, cover mounting screws 206 and seal 624. Pilot valve : PME-XXYZZ, including seal 67. Pressure seal between valve and base : 646. Mounting screw valve to base (x4) : 46. Check valve : 70002 (+M-000). dimensions A Dimensions shown are metric (mm) B 9,9 6,2 24,4 2 4 46,0,0 27,0 2 4 4,,0 22,0 4,0 4,0 20, 20, ISO Individual mounting /8 EXTERNAL PILOT 49,0 49,0 68,0,0 40,0,0 7, 70,0 Ø 8, MTG. HOLES TYPE A B 2,0 2 4 9, JA & JC JB & JD 26.6 49.6 247. 28.8 64,0 2,0,0 49,0 49,0 78,0 6,0 79,0 OPTIONAL BOTTOM PORTS 68 Consult Precautions page 64 before use, installation or service of MAC Valves

B a s e s a c c o r d i n g t o I S O 9 9 Series ISO Series ISO ISO 2 ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Side & bottom ports Bottom cylinder ports 2 and 4. Bottom inlet port /2 NPTF MB-AB-22 MB-AB-22 MB-AB-222 MB-AB-224 /4 NPTF MB-AB-2 MB-AB-2 MB-AB-22 MB-AB-24 Options: MB-AB-XXXF Optional Integral Flow Controls 289 Consult Precautions page 64 before use, installation or service of MAC Valves

00% 00% WARRANTY 8 OF PRODUCTION TESTED 00% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual ISO DIN 99/,0 40,0,0 7, 70,0 Ø 8, 4 MTG. HOLES 46,0,0 27,0 /8 EXTERNAL PILOT 2,0 2 4 2 4 64,0 2 4 4,,0 22,0 4,0 4,0 20, 20, 49,0 49,0 2,0,0 49,0 49,0 78,0 6,0 9, 79,0 OPTIONAL BOTTOM PORTS 290 Consult Precautions page 64 before use, installation or service of MAC Valves

O p t i o n s O P T I O N S Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) 2 4 OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 00 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 00 Series Series : - 6-700 - 800-900 - 600-600 - 6600-00 - ISO - ISO 2 - ISO. - MAC 2 - MAC 20 - MAC 00 - pilot operated valves with pilots type 200 Series Series : 200-7 - 8-9. - Pilot operated valves with pilots "CNOMO" Series : ISO - ISO2 - ISO 7 Consult Precautions page 64 before use, installation or service of MAC Valves

I n t r i n s i c a l l y S a f e V a l v e s Series ISO -2- MV-AC ISO MV-A2B ISO 2 MV-AB ISO MAC ISO valves are built to International Standards Organization (ISO) Std. 99/. They are available in sizes; ISO, 2 &. To select th ISO size required, insert the appropriate ISO number in the th position of the model code; EXAMPLE MV-AC for ISO, MV-A2B for ISO 2, or MV-AB for ISO. Bases and manifolds must be ordered separately from the table below. HOW TO ORDER SOLENOID PILOT OPERATED VALVES LESS BASE SINGLE PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN DBL. OPERATOR 2-POSITION PILOT SUPPLY DBL. OPER. -POS. CLOSED CENTER DBL. OPER. -POS. OPEN CENTER MV-AXB-A-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A22-FM-AJA MV-AXB-A2-FM-AJA Internal Pilot External Pilot External Pilot for use with Regulator MV-AXB-A2-FM-AJA MV-AXB-A22-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A-FM-AJA DUAL PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN DBL. OPERATOR 2-POSITION PILOT SUPPLY DBL. OPER. -POS. PRESSURE CENTER MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A4-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A22-FM-AJA MV-AXB-A24-FM-AJA Int. Pilot-From Port Int. Pilot-From Port External Pilot MV-AXB-A-FM-AJA MV-AXB-A2-FM-AJA MV-AXB-A4-FM-AJA SOLENOID PILOT VALVE OPTIONS XX - XXYZZ XX PILOT EXHAUST XX DC VOLTAGE Y MANUAL OPERATOR ZZ EXTERNAL PLUG-IN ZZ ENCLOSURE FM Muffled exhaust FP Piped exhaust A 2 VDC (0.6 W) A6 24 VDC (0.6 W) 0 No operator Non-locking Recessed (std.) 2 Locking Recessed Non-locking Extended 4 Locking Extended JA Square without light (on solenoid) JB Rectangular without light (on solenoid) JE Square without light (on body) JF Rectangular without light (on body) AA JIC w//2" NPS Conduit BA Grommet CA Conduit /2" NPS CC Conduit /2" NPT (CSA Threads) BASE TABLE ISO TYPE PORT SIZE INDIVIDUAL BASE MANIFOLD BASE BSPP NPTF BSPP NPTF ISO /4" MB-AC-2 MB-AC-22 MM-AC-2 MM-AC-22 /8" MB-AC- MB-AC-2 MM-AC- MM-AC-2 ISO 2 /8" MB-A2B-2 MB-A2B-22 MM-A2B-2 MM-A2B-22 /2" MB-A2B- MB-A2B-2 MM-A2B- MM-A2B-2 ISO /2" MB-AB-2 MB-AB-22 MM-AB-2 N/A /4" MB-AB- MB-AB-2 MM-AB- N/A For manifold bases a common external pilot port is available. One connection only is required for all valves in the manifold whether single or double solenoid. Bottom ports are also available; consult factory for ordering information for these options. MANIFOLD FASTENING KIT For each gang, one kit is required. To order specify par number N-6002-0. Consult Precautions page 64 before use, installation or service of MAC Valves

O P T I O N S Used on valve series: 00,, 6, 700, 800, 900, 600, 600, 6600, 00, MVAC, MVA2B, MVAB, MAC2, MAC20, MAC00. - XX Y ZZ VOLTAGE. VOLTAGE (00 Serie type coil) 20/60, 0/0 2 240/60, 220/0 00/60, 00/0 200/60, 200 /0 6 0/60 20 6/60 2 2/0, 2/60 22 24/60, 24/0 2 2/60, 2/0 24 48/60, 42/0 26* 80/0, 440/0, 440/60, 480/60 29 220/60 4 27/0, 20/0 48/0 6 6/60 B 24/0 0 24 VDC (6 W) 24 VDC (4 W) 4 2 VDC (4 W) 2 VDC (6 W) 7 2 VDC (2. W) 9 24 VDC (2. W) 60 2 VDC (8. W) 6 24 VDC (8. W) 64 6 VDC (6 W) 6 2 VDC (7 W) 66 48 VDC (.8 W) 67 64 VDC (7. W) 68 20 VDC (6.4 W) 69* 220 VDC (8.7 W), 20 VDC (.2 W) 7 90 VDC (8.8 W) 76* 00 VDC (6.9 W) 84* 2 VDC (0.9 W) 87* 24 VDC (7. W) 88* 2 VDC (7.4 W) 89* 6 VDC (8.8 W) 90 28 VDC (8.2 W) 9* 6 VDC (0.6 W) 92 90 VDC (6. W) 94 VDC (7 W) 9 8 VDC (6.4 W) A 24 VDC ( W) A2 2 VDC ( W) A 9 VDC ( W) MOD. DD0 : Protection diode (DC) - MAX. 8.W MOD. MOV : Protection varistor (AC) - MAX. 8.W * Voltages are CLSF only Used on valve series: 200, 7, 8, 9.. VOLTAGE (200 Serie type coil) - XX Y ZZ VOLTAGE 20/60, 0/0, 24 VDC (6 W) 2 240/60, 220/0 00/60, 00/0 4 200/60, 200/0 20 6/60 2 2/60 22 24/60, 24/0 2 2/60, 2/0 24 48/60, 42/0 2 240/0 26 480/60, 440/0 27 27/60 28 4/0 29 220/60 0 80/0 0/60, 0/0 2 20/60, 0/0 600/60 4 27/0 48/0 0 24 VDC (6 W) 24 VDC (4. W) 2 24 VDC (2. W) 24 VDC (.0 W) 2 VDC (6 W) 7 2 VDC (2. W) 8 48 VDC (2. W) 60 2 VDC (9. W) 6 24 VDC (8. W) 64 6 VDC (8. W) 6 2 VDC (0 W) 66 48 VDC (. W) 67 64 VDC (0. W) 68 20 VDC (2. W) 69 20 VDC (9.2 W) 7 8 VDC (8.2 W) 72 24 VDC (2 W) 7 98 VDC (0 W) 74 72 VDC (. W) 7 90 VDC (. W) 76 00 VDC (9 W) 77 220 VDC (0 W), 20 VDC (.6 W) 78* 24 VDC (24 W) 80 VDC (0.6 W) 82 70 VDC (. W) 8 VDC (8. W) 84 2 VDC (0 W) 86 6 VDC ( W) 9* 2 VDC (24 W) 8 Consult Precautions page 64 before use, installation or service of MAC Valves

O p t i o n s O P T I O N S 2. MANUAL OPERATOR (Common options for 00 & 200 Series type coils) - XX Y ZZ MANUAL OPERATOR 0 No operator * No Operator with Light Non-locking recessed 6* Non-Locking Recessed with Light 2 Locking recessed 7* Locking Recessed with Light Non-locking extended 8* Non-Locking Extended with Light 4 Locking extended 9* Locking Extended with Light * Lights used with AA electrical connection. ELECTRICAL CONNECTION (00 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with /2" NPS conduit BA Flying leads CA /2" NPS conduit CC /2" NPT conduit FA Military type 2 PIN GA Military type PIN HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO) JF Rectangular connector on top (ISO, ISO2, ISO) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit (00 Series-Manifold/900 Series) MB Electrical common conduit (00 Series-Stacking/700 Series) NA CA with ground wire NC CC with ground wire RA /8" NPS conduit * Not to be used with 00, 800 and 900 Series manifold mounting. ELECTRICAL CONNECTION (200 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with /2" NPS conduit BA Flying leads CA /2" NPS conduit CC /2" NPT conduit EA Explosion proof (200 Series) EA Explosion proof (7, 8 & 9 Series) FA Military type 2 PIN GA Military type PIN HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire 9 Consult Precautions page 64 before use, installation or service of MAC Valves