Residential Pressure Booster Systems

Similar documents
MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Aquavar SOLO 2 Frequently Asked Questions

Full Range Pressure Compensating Variable Flow Control

SINGLE VALVE WITH LOW-FLOW BYPASS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Accessories. Valves. Adjustable Pressure Relief Valves

pvc well casing & drop pipe

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Accessories. Valves. Adjustable Pressure Relief Valves

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Domestic water supply

PRESSURE REGULATOR GUIDE

POWER IS PRODUCED IN THE HEAD

Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

User Manual for the Mars Calibration Bench

TECHNICAL DATA NOTICE

Installation and commissioning instructions 255 series and 256 series

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

PRO-50 Instrument Supply Regulator

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

Operating Instructions Models and Hydrostatic Test Pumps

Presented to the IAPMO Standards Review Committee on March 7, 2016

Pressure Independent Control Series

SIZING THE WELL-X-TROL

Air Amplifiers & SYSTEMS

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

200 PSI COMPRESSORS - MODEL NUMBERS

STAINLESS STEEL GRAND SERIES

Domestic water supply

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

CP3R Quick Start Manual

IMPORTANT SAFETY INSTRUCTIONS

CPN1 Quick Start Manual

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

PDF // GRUNDFOS SUBMERSIBLE PUMP SPECIFICATIONS DOWNLOAD

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

100C Air Compressor Kit

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Reverse Osmosis System Installation Guide and Operation Manual.

VB-7263 Series. Application. Features. Applicable Literature

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Tightness controls TC 1 3 and TC 4

Booster Regulator/Air Tank

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

PRESSURE SWITCHES Bulletin 8757

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Electronic Control Pump Instruction Manual

KIT. Small Automatic Water Boosters KIT MODELS

Pressure on Demand. Air Pressure Amplifiers

Operating Instructions Model and Hydrostatic Test Pump

T EK-SUB 4800C 19 mm Submersible Level Transmitter

VB-7273 Series. Application. Features. Applicable Literature

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Electronic Control Pump Instruction Manual

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

DS06D,G Dial Set Pressure Regulating Valve

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Flow Material Length. Weight GPM LPM. Style 3095

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

SIZING OF WATER PIPING SYSTEM

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

TECHNICAL DATA Q= C. Table 1 - Specifications

MPULSE 3000TM. Instruction & Owner s Manual. Pool Water Treatment System. 890 W.Grant Rd., Tucson, AZ, (877) * (520) Fax

Accu-Tab Systems 1000 Series by Axiall Corporation

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Series 58 SAFETY VALVES 312

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Lesson 6: Flow Control Valves

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

VBS-9263 Series. Application. Features. Applicable Literature

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

North American 7339 High Pressure Gas Regulators

Electronic Control Pump Instruction Manual

Constant and Particle Free Point-of-Use Water Pressure

RESIDENTIAL WATER DISTRIBUTION

VERTICAL BLADDER TANK

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

TurboDraft Fire Eductor

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Transcription:

Residential Pressure Booster Systems

HOW IT WORKS When the pressure available is insuffi cient it is necessary to install a boosting system. FLUX BOOSTING SYSTEM starts and stops according to the user s needs. It replaces the traditional pressure switch/tank systems, offering more advantages such as: Easy installations. Reduced dimensions. Constant fl ow. Low maintenance required. No need to install pressure tanks. Pump protection against running dry, with automatic reset. The FLUX BOOSTING SYSTEM monitors the fl ow rate of the water running thru and protects the pump against dangerous working conditions like running dry. When a tap is opened and the water demand exceeds the minimum starting fl ow, FLUX starts the pump and keeps it running, delivering constant fl ow, even when capacity request is low. FLUX BOOSTING SYSTEMS stops the pump when the demand is below 0.5 gal/min. In case of a leak on the system (less than 0.5 gal/min) FLUX BOOSTING SYSTEM will never start the pump avoiding useless power consumption. SAVE: Money Space Installation Time APPLICATIONS FLUX BOOSTING SYSTEM is made up of a water pump and an electronic pump controller which is used for: Residential irrigation applications when it is necessary to boost the pressure coming from the city water or a well pump. Page 3

TECHNICAL SPECIFICATIONS Voltage: 230 Volt or 115 Volt FLUX protection: Water Resistant Water pump protection: Outdoor Use Dimensions: depends on the system selected. Working temperature: 32-122 F. Connections: 1 standard NPT. Maximum working pressure: 140 psi. Minimum fl ow rate: 0.5 gpm. FEATURES AND BENEFITS FLUX s body made of technopolymer with a built-in check valve. FLUX BOOSTING SYSTEM comes available with different pumps to boost in coming pressures up to 70 psi higher (for selection chart see pages 5-6) Friction losses extremely low: this is why it is possible to use FLUX BOOSTING SYSTEM with capacity up to 50 gpm. The special valve guarantees the pump continuous operation. Circuit board: easy to replace and available in 115V and 230V. Flux Boosting System may be installed with a pressure reducer valve. (see manual) Residential Pressure Booster Systems Page 4

200 RB204-F 175 150 Head H (feet) 125 100 75 RB303.5-F RB203-F 50 25 0 0 SELECTION CHART APPLICATIONS FOR MODEL RB203-F PUMP MODEL: RB203 PUMP CONTROLLER: FLUX WATER SUPPLY: CITY WATER OR SUBMERSIBLE PUMP 5 55 65 75 85 95 Residential or light irrigation with a 10 50 60 70 80 90 15 45 55 65 75 85 20 35 45 55 65 75 APPLICATIONS FOR MODEL RB204-F PUMP MODEL: RB204 PUMP CONTROLLER: FLUX WATER SUPPLY: CITY WATER OR SUBMERSIBLE PUMP minimum 10 psi incoming. Call factory for proper sizing assistance. PH: 925-754-5686 5 76 86 96 106 116 Residential and light irrigation requiring additional psi with gravity flow from city 10 63 73 83 93 103 main or storage tank. 15 55 65 75 85 95 Call factory for proper sizing assistance. PH: 925-754-5686 APPLICATIONS FOR MODEL RB303.5-F 10 20 30 40 50 60 Capacity (US g.p.m.) PUMP MODEL: RB303.5 PUMP CONTROLLER: FLUX WATER SUPPLY: CITY WATER OR SUBMERSIBLE PUMP 10 52 62 72 82 92 Larger Residential and irrigation 20 50 60 70 80 90 requiring higher flows with a minimum 30 45 55 65 75 85 10 psi incoming. Call factory for proper 40 38 48 58 68 78 sizing assistance. PH: 925-754-5686 It is required by code that all residential systems be limited to 80 psi system pressure to prevent damage to piping and fixtures. Page 5

DIMENSIONS RB203-F RB204-F 13.9 16.0 Ø 1 Ø 1 7.5 8.5 RB303.5-F 13.5 8.0 Ø 1 14.0 Ø 1¼ 14.16 15.36 WEIGHT= 21 lbs 28 lbs Ø 1 Ø 1 ¼ WEIGHT= 24 lbs Before installing the pump, be sure that the maximum flow of the water meter will not be exceeded (see reference). REFERENCE METER SIZE MAX FLOW (GPM) 5/8 12 3/4 20 1 30 1 1/2 50 Flux Boosting System may be installed with a pressure reducer valve. (see manual) Page 6 2 70