Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Similar documents
IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IECEx Certificate of Conformity

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

A Unified Marking System for Ex Equipment

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

IECEx Certificate of Conformity Annexe

Operating Instructions

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. Dimensions

Further technical information is available on

Technical Data. Dimensions

VG5 Supplementary instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

ELECTRIC ACTUATORS for continuous underwater use

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

W01 Rolled Steel Fractional Horsepower Motor

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Operating Instructions

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

slra of Gonformity IECEx Cert f cate )ol4- ob cst

Technical Data. Dimensions

Certificate of Conformity

OIL+GAS PRODUCTS AND THEIR APPLICATIONS

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

Technical Data. Dimensions

Technical Data. Dimensions

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

Certificate of Compliance

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Installation and Operation Manual

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Certificate of Compliance

Arran LED Floodlight Luminaire

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

Operating Instructions of BROSA tension load cells, types 0111, 0113

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

IECEx Certificate of Conformity Annexe

Pressure switch, Differential pressure switch and Thermostat RT-E

ComEx Actuating elements

Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch. Quick Start Guide , Rev BA August 2012

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Operating Instructions

Certificate of Conformity

Technical Data. Dimensions

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

The evolution of the Ex-proof flame path

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Technical Data. Dimensions

Part I - Installation

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Intertek Testing Services Taiwan Ltd.

Part I - Installation

Certificate of Compliance

IECEx certification of Non-Electrical Ex Equipment

High-performance submersible pressure transmitter For level measurement Model LH-20

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

Pressure control, differental pressure control and thermostat Type RT

High-performance submersible pressure transmitter For level measurement Model LH-20

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Level switches Series LD Vibrating fork level switch for liquids and solids

WHITE PAPER on Explosion Proof and Intrinsic Safety Solutions. Oct. 2013

Magnetic level switch type MR783 Instruction Manual

Junction Boxes Series 8118

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Certificate of Compliance

@h..p. lntertek. IECEx Certificate of Conformity

IECEx Certificate of Conformity

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

CERTIFICATE OF COMPLIANCE

Inductive slot sensor

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Monitoring device NTS 30

Tightness controls TC 1 3 and TC 4

ATM.1ST/Ex - High Precision Transmitter

Instructions for Safe Use

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

Level switches Series LD Vibrating fork level switch for liquids and solids

Perpetua Power Puck Solutions

IECEx Certificate of Conformity

120 Series Explosion-Proof Pressure and Differential Pressure Switches

RTD temperature probes

Electro-Pneumatic Converter YT-940 SERIES

Transcription:

Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST ELECTRIC MOTORS (PTY) LTD PO BOX X10011 SANDTON 2146 IA CERTIFICATE Equipment: A Range of Induction Motors Manufacturer: WEG Equipamentos Eletricos S.A Type: A Range of Induction Motors of Frame Size 160 to 200 and of Frame Size 90 to 132 and frame size 71 & 80 Serial No: All items imported between Issued and Expire. Supplied by Zest Electric Motors (Pty) Ltd Identified by Inspection Authority number S-XPL/14.1342 X And as described in the Explolabs file number XPL/15478/14.1342 is hereby certified "Explosion Protected Ex d IIC T4 Gb Ta -55 C to + 80 C or Ex de IIC T4 Gb Ta -55 C to + 80 C;Ex tb IIIC T135 C Db IP66 Ta -55 C to + 80 C see schedule", having been examined and inspected in accordance with the relevant requirements of South African Standards. SANS 60079-0: 2012 Ed 5 IEC 60079-0: 2011 Ed 6 SANS 60079-1: 2009 Ed 4 IEC 60079-1: 2007 Ed 6 SANS 60079-7: 2007 Ed 3 IEC 60079-7: 2006 Ed 4 Issued: 11 Nov 2014 *Expire: 11 Nov 2017 Page 1 of 6 Revision 1 Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 1: Equipment protection by flameproof enclosures d Explosive atmospheres Part 7: Equipment protection by increased safety "e" SANS 60079-31: 2009 Ed 1 IEC 60079-31: 2008 Ed 1 Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t" Locations Gas and Dust: Surface Gb Gas Db Dust Frequency Intermittent as could occur under normal operation Environment Group IIC/IIIC Propane to Hydrogen plus Acetylene and Conductive Dust Limiting Temp. T4 135 C This certification indicates compliance with R10.1 of the Mines Health and Safety Act and/or EMR 9(2) of the Occupational Health and Safety Act, provided that the apparatus is used as relevant in accordance with: i) SANS 10086 and IEC/SANS 61241-14 requirements as applicable; ii) Any conditions mentioned in the above report; iii) Any relevant requirements and codes of practice enforced in terms of the Mine Health and Safety Act or Occupational Health and Safety Act; and iv) Any restrictions and conditions enforced by the Chief Inspector of Mines or the Principal Inspector or the Chief Inspector: Occupational Health and Safety. v) A revision certificate replaces all previous version of the certificate. vi) * - Only covers equipment Imported between the Issued and Expire dates. vii) If and when your QAN (Quality Assurance Notification) Certificate for your equipment manufacturer expires during the valid period of the IA Certification (issued for your equipment) and a new certificate is not submitted the existing IA Certification will then be cancelled. It is thus the client s responsibility to always submit the updated and valid QAN certificate(s) to Explolabs (Pty) Ltd This

ANNEX TO CERTIFICATE NO S-XPL/14.1342X REV 1 PAGE 2 OF 6 1. GENERAL According to certificate IECEx BAS 13.0142X issue No 0 A Range of Induction Motors of Frame Size 160 to 200 The range of induction motor of frame size 160 to 200 comprises a stator frame, endshields and main and auxiliary terminal boxes all manufactured from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. The terminal box cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The wall between the terminal box and the motor frame is provided with flameproof potted cable bushings for the winding tails and auxiliary cables for thermal sensors etc. The terminal boxes may be designated flameproof Ex d, increased safety Ex e within the provisions of this report or increased safety terminal boxes as permitted on IECEx BAS 10.0099X. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anti-condensation heaters rated as indicated below. The motors are rated from 220V to 1140V when supplied with an Ex d terminal box, or from 220V to 690V when supplied with an Ex e terminal box, 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type PWM inverter manufactured by WEG or any other inverter having identical parameters affecting the thermal performance of the motor. The maximum voltage on the auxiliary terminals is 440V. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40oC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. Frame size 160 180 200 Maximum output (kw) 22 30 45 Poles 2 to 12 Heater (W) 30 30 38 The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66. Options include a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, forced ventilation and a breather drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component) under an EC Type Examination Certificate to Directive 94/9/EC. When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure.

ANNEX TO CERTIFICATE NO S-XPL/14.1342X REV 1 PAGE 3 OF 6 Variation 1.1 The motors may be alternatively marked for gas groups IIA, IIB I, dust groups IIIB, IIIA, temperature classifications of T3, and T2 without an increase in ambient temperature above 80oC, ingress protection IP5X, IP6X, gas only and dust only as indicated below. I M2 G Ex d I T* Ta -**oc to + **oc Mb II 2 D Ex tb III* T***oC Ta -**oc to + **oc Db IP** According to certificate IECEx BAS 13.0045X issue no 0 A Range of Induction Motors of Frame Size 90 to 132 The range of induction motor of frame size 90 to 132 comprises a stator frame, endshields and main and auxiliary terminal boxes all fabricated from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. The terminal box cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the integral main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The wall between the terminal box and the motor frame is provided with flameproof potted cable bushings for the winding tails and auxiliary cables for thermal sensors etc. The terminal boxes may be designated flameproof Ex d, or increased safety Ex e. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anti-condensation heaters rated as indicated below. The motors are rated from 220V to 1100V when supplied with an Ex d terminal box, or from 220V to 690V when supplied with an Ex e terminal box, 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type VPWM, CFW09 or CFW11 invertors manufactured by WEG. The maximum voltage on the auxiliary terminals is 440V. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40oC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. Frame Size 90 100 112 132 Maximum output (kw) 3.0 4.0 7.5 11.0 Maximum output (kw) with permanent magnet and VFD 4.5 7.5 11.0 22.0 Poles 2 to 12 Heater (W) 11 11 22 30 The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66. Options include permanent magnet, a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, forced ventilation and a breather-drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs.

ANNEX TO CERTIFICATE NO S-XPL/14.1342X REV 1 PAGE 4 OF 6 The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component). When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure Variation 1.1 The motors may be alternatively marked for gas groups IIA, IIB I, dust groups IIIB, IIIA, temperature classifications of T3, and T2 without an increase in ambient temperature above 80oC, ingress protection IP5X, IP6X, gas only and dust only as indicated below. I M2 G Ex d I T* Ta -**oc to + **oc Mb II 2 D Ex tb III* T***oC Ta -**oc to + **oc Db IP** According to certificate IECEx BAS 13.0008X issue no 0 The range of induction motor of frame size 71 and 80 comprises a stator frame, endshields and main and auxiliary terminal boxes all fabricated from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. All cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anticondensation heaters rated up to 7.5W. The motors are rated from 220V up to 1100V 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type VPWM, CFW09 or CFW11 invertors manufactured by WEG. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40oC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66 to a maximum temperature of 160oC. Options include a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, and a breather-drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component) under an EC Type Examination Certificate to Directive 94/9/EC.

ANNEX TO CERTIFICATE NO S-XPL/14.1342X REV 1 PAGE 5 OF 6 When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure Based on the following documentation: IECEx BAS 13.0142X issue No 0,IECEx BAS 13.0045X issue No 0 and IECEx BAS 13.0008X 2. SPECIAL CONDITIONS OF USE (X) The flamepath gaps are less that those permitted by IEC60079-1 for gas group IIC and shall not be enlarged in service. The motors may be provided with integral leads, which must be suitably protected and terminated within an enclosure suitable for the conditions of use. When provided with a breather-drain to IECEx CSA 12.0005U the motors are excluded from Group I, and are limited to temperature classification T5 to T2 Ta -55 C to + 50 C, or T4 to T2 Ta -55 C to + 80 C, and have an IP rating of IP6X. The maximum surface temperature was determined without a dust layer. The end user shall prevent a dust layer forming on the motors. After de-energising a delay 60 minutes is required before opening. According to certificate IECEx BAS 13.0008X issue no 0 1 The flamepath gaps are less that those permitted by IEC60079-1 for gas group IIC and shall not be enlarged in service. 2 The motors may be provided with integral leads, which must be suitably protected and terminated within an enclosure suitable for the conditions of use. 3 When provided with a breather-drain to IECEx CSA 12.0005U the motors are excluded from Group I, and are limited to temperature classification T5 to T2 Ta -55 o C to + 50 o C, or T4 to T2 Ta -55 o C to + 80 o C, and have an IP rating of IP6X. 4 The maximum surface temperature was determined without a dust layer. The end user shall prevent a dust layer forming on the motors. 5 After de-energising a delay 60 minutes is required before opening.

ANNEX TO CERTIFICATE NO S-XPL/14.1342X REV 1 PAGE 6 OF 6 3. MARKING The following marking must be added to the units in a legible and durable manner: Supplier : Zest Electric Motors (Pty) Ltd Equipment : A Range of Induction Motors Type : A Range of Induction Motors of Frame Size 160 to 200 and of Frame Size 90 to 132 and frame size 71 & 80 IA Number : S-XPL/14.1342 X Rating : Ex d IIC T4 Gb Ta -55 C to + 80 C or Ex de IIC T4 Gb Ta - 55 C to + 80 C;Ex tb IIIC T135 C Db IP66 Ta -55 C to + 80 C see schedule If the above marking does not appear on the unit, this certificate does not cover it. D Maree Senior Testing Officer EXPLOLABS EXPLOSION PREVENTION SERVICES This report/certificate shall not be reproduced except in full without the written approval of the company Explolabs (Pty) Ltd shall not be liable for any losses or damages sustained on account of any failure or omission to properly perform our duties in terms of any contract undertaken by us. This disclaimer is immutable and automatically incorporated in any contract undertaken by us; notwithstanding anything to the contrary, save for the express written waiver of our managing director. The contents of electronic reports/certificates cannot be guaranteed. Original certification documents will be kept on file at Explolabs (Pty) Ltd