EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

Similar documents
EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

Quick Start Setup Instructions for Raven LRC & AgXcel Harness for NH3 Profile plus GX40 Synergist

Touch on the New button to create the new implement.

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

WATER CONTROL SYSTEM QUICK START

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Stand-Alone Bubble Detection System

Hydro-Control V User Guide

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

ACV-10 Automatic Control Valve

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

DRILL MONITOR DM-100 OPERATIONS MANUAL

FAULT CODE TROUBLESHOOTING INDEX

IBU3 Manual Addendum 1

REACTOR 40 MECHANICAL Configuration Guide

WeatherTRAK ET plus Series Quick Reference Guide

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

Electro-hydraulic control valve - Calibrate - Remote valve calibration

Earthworks X200 Quick Reference Guide

Operating instructions Electrical switching facility pco

Autopilot setup. VRF (Virtual Rudder Feedback) calibration. Software setup NSS evo2 Installation Manual

Golf Team Challenge. Product: EA SPORTS PGA TOUR Software Version: Release Date: 10/18/06. Revised 4/21/2009

KIV-SACS Safe automatic calibration system:

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

MONSOON 6V Pump Control System

Operating Instructions

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

USA Jump Rope Tournament Software User Guide 2014 Edition

WELCOME TO THE REVOLUTION

ECL Comfort 110, application 131 (valid as of software version 2.00)

HumiSys HF High Flow RH Generator

LX Compass module 3 Electronic compass device User manual

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

6800 Maintenance Instruction System Flush Procedure

SHIMADZU LC-10/20 PUMP

LVU2800 Series. Ultrasonic Level Transmitter

Laboratory Mortar Mixer (Testing)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

PC Configuration software for Discovery MkVI v 1.03 User guide

Built-in Purge Control Functions

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Technical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured

FRDS GEN II SIMULATOR WORKBOOK

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

GNX 20/21. Owner s Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

ActiveYield. Operation and Adjustment

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

In Vivo Scientific, LLC INSTRUCTION MANUAL

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

TR Electronic Pressure Regulator. User s Manual

User Manual for the Mars Calibration Bench

APA software instruction manual

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

WARNING FOR YOUR SAFETY

1020 Industrial Drive, Orlinda, TN fax

Navigator 600 Silica analyzers

These variables can be accessed by holding the UP button for 5 seconds.

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

The Discussion of this exercise covers the following points:

Mitos Fluika Pressure and Vacuum Pumps Datasheet

GNX 20/21. Owner s Manual

UsER manual for Watersens ph -REDOX

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

CONTROL and INSTRUMENTATION

Connect with Confidence NO POWER NO PROBLEM

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

Overview. Front Panel: Keypad and Display

Indications for Use: Caution: Note:

Running the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Richards Industries Basic Siemens PS2 Positioner Functions

Instruction Manual Dräger MSI P7 and MSI P7 plus

All Sport 5000 Control Console

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

E L E C T R O N I C S X T

Fisher DVI Desuperheater Venturi Inline

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

955108_2. AirForce Operator s Guide

LENNOX SLP98UHV DIAGNOSTIC CODES

Ultima. X Series Gas Monitor

Datasheet: K-30 ASCII Sensor

Touch Screen Guide. OG-1500 and OG Part # T011

KEM Scientific, Inc. Instruments for Science from Scientists

BI-680 Online Dissolved Oxygen Controller Instruction Manual

ENS-200 Energy saving trainer

Astral in AirView: Improving patient care through connectivity. ResMed.com

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

SC 110 Autopilot Installation and Operations Manual _A

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Transcription:

INTRODUCTION This figure shows the front panel of the EZ-Boom 2010 automated application control system. Status indicator Rate switch Rate Adjustment (Inc/Dec) switch Master switch Boom section switches CONNECTING This figure shows how to connect the EZ-Boom controller to the other system components. EZ-Boom controller EZ-Guide Plus lightbar TO EZ-BOOM EZ-Steer controller Power EZ-Steer cable (P/N 52763) TO POWER EZ-STEER CONTROLLER TO SCM EZ-Boom Y cable (P/N 58377) OR CAN terminator (P/N 58378) 58378R REV 1 DCA 0615 1. On the EZ-Steer system power cable (P/N 52763), disconnect the female DE9 connector ( EZ-STEER CONTROLLER ) from the EZ-Steer controller (if fitted). 2. On the EZ-Boom Y cable (P/N 58377): a. Connect the male DE9 connector marked TO POWER to the female DE9 connector marked EZ-STEER CONTROLLER on the EZ-Steer power cable (P/N 52763). b. Connect the female DE9 connector marked TO SCM to: the EZ-Steer controller (if an EZ-Steer system is installed) the CAN terminating connector (if an EZ-Steer system is not installed) 3. Connect the Deutsch connector ( TO EZ-BOOM ) to the socket on the back of the EZ-Boom controller.

CONFIGURATION PROCESS 1. Install and connect the hardware. See CONNECTING. 2. Set up the boom. 6. Set up the flow control valve. 3. Set up the antenna/implement offset. 7. Set up the tank. 4. Set up automatic boom switching. 8. Calibrate the pressure sensor (if fitted). 5. Set up the application. 9. Calibrate the flow meter. For a detailed description of these steps, see the following pages.

STEP 2. BOOM SETUP 1. From the configuration menu, select EZ-Boom / Boom. The Boom Setup screen appears. 2. Press the u and D keys to set the Swath Width spacing and Boom Width (coverage width) and then press o. To create overlap, use a swath width that is narrower than the boom width. 3. Enable any fence nozzles. Fence nozzles are at the far ends of the boom and point out to the sides to cover any fence lines. Switch 1 controls the left fence nozzle, and the first switch after the boom section switches controls the right nozzle. With two fence nozzles, the system supports up to eight boom sections. Fence nozzles are always manually controlled. They must be activated with the corresponding switch. 4. Press the u and D keys to set the Number of Sections value and then press o. This is the number of sections in the boom. The section widths will automatically adjust to a default that is calculated by dividing the Swath Width value by the Number of Sections value. 5. Press u or D to adjust the section width values and then press o. As you adjust each section width, the later section widths are adjusted so the specified Boom Width is maintained. 6. Select Exit and then press o. STEP 3. SET THE ANTENNA/IMPL OFFSET 1. From the configuration menu, select EZ-Boom/Ant/Impl Offset. The antenna/impl offset screen appears. 2. Press u or D to adjust the distance the antenna is from the spray boom. You can set the antenna to ahead of, or behind, the implement. 3. Select Exit and then press o. STEP 4. AUTOMATIC BOOM SWITCHING SETUP 1. From the configuration menu, select EZ-Boom / Swath Control. The Swath Control screen appears. 2. Set the Boom Control option to Auto or Manual switching and then press o. 3. Set the Lead In time and then press o. This is the number of seconds before leaving a sprayed area and entering an unsprayed area that the boom sections will turn on. 4. Set the Off Delay time and then press o. This represents the amount of time before or after you enter a previously sprayed area that you want the boom sections to turn off. For example, if you want the boom sections to turn off 1 second before you cross into a headland, set the Off Delay time to -1.0 seconds. 5. Select either Minimize Skip or Minimize Overlap. 6. Select Exit and then press o.

STEP 5. APPLICATION SETUP 1. From the configuration menu, select EZ-Boom / Application. The Application Setup screen appears. 2. Set the Rate Control option to On or Off and then press o. Note If you want the EZ-Boom system to control boom switching only, set Rate Control to Off. 3. If you set the Rate Control option to On: a. Set the Rate 1 value and then press o. b. Set the Rate 2 value and then press o. c. Set the Allowable Error percentage. This is the percentage of allowable Rate1 or Rate2 error before the flow control valve adjusts. d. Set the Min Flow value. If this point is reached, the flow control valve will not reduce the application rate any further. e. Set the Step value. This is the amount that each operation of the Rate Adjustment (Inc/Dec) switch will increase or decrease the current application rate when the Rate switch is in the Rate 1 or Rate 2 position. Note In the Manual position, Step does not apply. The Rate Adjustment (Inc/Dec) switch actuates the valve directly (hold the switch to increase/decrease). 4. Select Exit and then press o. STEP 6. FLOW CONTROL VALVE SETUP 1. From the configuration menu, select EZ-Boom / Control Valve. The Ctrl. Valve Setup screen appears. 2. In the Type field, select the type of control valve: Inline Servo, Bypass Servo, Pump Servo, or PWM. 3. If the valve type is Inline Servo, Bypass Servo, or Pump Servo: a. Set the Response1 value to the desired adjustment speed of the valve when the application rate is outside the Threshold. b. Set the Response2 value to the desired adjustment speed of the valve when the application rate is within the Threshold. c. Set the Threshold. This is the point at which the application rate is close enough to the target rate for the adjustment speed of the valve to switch from Response1 to Response2. If the valve type is PWM: a. In the Frequency field, select the operating frequency of the valve. b. Set the Gain value. This determines the adjustment speed of the valve. c. Set the 0 Flow Offset. This is the shut-off point of the PWM valve. 4. Select Exit when done.

STEP 7. TANK SETUP 1. From the configuration menu, select EZ-Boom / Tank Setup. The Tank Setup screen appears. 2. Set the Capacity value to the capacity of the tank when full. 3. Set the Curr Volume value to the current volume of the tank. This value will decrease as you use the spray solution. 4. Set the Low Limit value. A warning appears when the volume reaches this level, to warn you that the tank is nearly empty. 5. Select Exit when done. STEP 8. PRESSURE CALIBRATION 1. From the configuration menu, select EZ-Boom / Pressure Calibration. The Pressure Calibration screen appears. 2. Set the Slope value. Slope is the relationship between pressure and the output of the sensor. The default of 16 mv/psi is recommended for a Raven pressure sensor. Slope is measured in mv/kpa or mv/psi. 3. Set the Set Point value. The Set Point is the actual pressure at the time of calibration. The Pressure value shows the pressure that the sensor is reporting and will update, based on the Slope and Set Point entered. 4. Select Calibrate to send the new Slope and Set Point values to the EZ-Boom controller. After calibrating, check that the Pressure value is correct. 5. Select Exit when done. STEP 9. FLOW METER CALIBRATION 1. From the configuration menu, select EZ-Boom / Flow Calibration. The Flow Calibration screen appears. 2. Enter the flowmeter calibration number. You can find the number on the flow meter, or by contacting the flow meter manufacturer. The number you enter will be either pulses per gallon (US) or pulses per litre (metric). 3. For a Raven flow meter, enter the calibration number as it is written on the tag. For other brands of flow meter, add a 0 to the number when you enter it (for example, if the number is 75, enter 750). Note At this point you can choose to use the flow meter calibration number by exiting the screen, or you can fine tune the calibration by following the steps below. 4. In the Target Rate field, set the desired application rate. 5. In the Speed field, set the desired speed. 6. In the Total Nozzles field, specify the number of boom nozzles that will be turned on during the calibration. Do not count the fence nozzles.

Note For correct calibration, all the boom (but not fence) nozzles must be operational and turned on. 7. Select Calibrate, read the information screen, and then select Start Flow to start the flow. 8. Measure the volume from 2 or 3 nozzles for 1 minute each. 9. Press o to stop the flow. 10. Calculate the volume per minute/per nozzle of your sprayer by dividing the total volume measured by the number of nozzles that you took measurements from. 11. In the Meas d Flow field, set the actual volume that you calculated in Step 10. The system will calculate the difference between the measured flow/nozzle and the averaged flow/nozzle. 12.Select Update Calibration to continue. The flowmeter calibration will be adjusted. DIAGNOSTICS To view the diagnostics information, from the configuration menu select EZ-Boom / Diagnostics. This information may be useful for troubleshooting or if you need support help. FAULT HISTORY To view previous system faults, from the configuration menu select EZ-Boom / Fault History. The EZ-Boom Faults screen shows the four most recent EZ-Boom system faults. The most recent appears at the top. Note Faults shown on this screen are not necessarily still active. NAVIGATION SCREEN: SPRAY ICON When the EZ-Boom system is connected to the EZ-Guide Plus lightbar guidance system, the spray icon appears among the action icons on the right of the lightbar display. The spray icon provides quick-access to some of the most common EZ-Boom system settings. The sprayer bar at the base of the screen indicates the state of the spray sections: Appearance x Empty box Solid box Description The boom section is disabled (the switch is off) The boom section is on, but not spraying The boom section is currently spraying For more info, refer to the EZ-Boom 2010 Automated Application Control System Getting Started Guide. 2006. Trimble Navigation Limited. All rights reserved. Trimble, the Globe and Triangle logo, AgGPS, EZ-Guide, and EZ-Steer are trademarks of Trimble Navigation Limited, registered in the United States Patent and Trademark Office and in other countries. EZ-Boom is a trademark of Trimble Navigation Limited. Version 1.00, Rev A. (August 2006). P/N 72100-80-ENG Rev A