Research Grade Blood Pressure Transducer

Similar documents
Research Grade Blood Pressure Transducer User's Manual

Large Animal Volume Controlled Ventilator

CONSTANT PRESSURE SYRINGE PUMP

Large Animal Volume Controlled Ventilator User's Manual

User s Manual. VentElite Publication REV-1.1

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

TSE Blood Pressure Monitor Invasive series

Large Animal Volume Controlled Ventilator User's Manual

User s Guide. Vacuum Controller for liquid delivery systems

! Warning, refer to accompanying documents.

DPC-30 DPC-100. Reference Manual

Installation and Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

ATS430 turbidity sensor Retractable insertion assembly

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

Yoke Block Instruction Manual

ATEX ATEX

Corning Step-R. Repeating Pipettor. Instruction Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Operating Instructions

4 and 8 Station PDS Control Installation & Operators Manual

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

MODEL 100 NITROGEN INFLATION CART

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Cadence Sensor W.I.N.D. User Manual

Digital Vacuum Regulator

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Digital Vacuum Regulator

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

AND OPERATION INSTRUCTIONS

BPS-2, Rev TABLE OF CONTENTS

SPS-5. Rate Computing Scale. Operation Manual

TrekMill USER'S MANUAL MM5050

[Instruments for vacuum measurement, checking and adjustment] 3

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

TV-114 TV-114-A Wind Speed Sensor User s Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Sterile Visual Flow Indicator

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Digital Melting Point Apparatus

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

LSA-BAWMBL. Wall-Mounted Boom Arm INSTRUCTIONS

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Yoke Block Instruction Manual

Installation, Operation and Maintenance Manual

OEM Manual. MODEL ½ Digit DRUM SCALE

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

User s Guide. Pressure Controller for liquid delivery systems

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

PM105 PRESSURE METER USER S MANUAL

User s Guide. CO2 & O2 Controller for miniature incubators

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

VERTICAL AIR COMPRESSORS

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

LM6 LEATHER MOISTURE METER

Ocean Technology Systems ComBox

Achat 112 mid-high-range speaker. user manual

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

Angled Sign Light with Shade

PRAHER PLC-MP AQUASTAR MANAUL 2009

Eastwood Versa-Cut Plasma Cutting System

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

In Vivo Scientific, LLC INSTRUCTION MANUAL

OFFICINE OROBICHE S.p.A. 1/9

USER S GUIDE AUTOTUNE SERIES HIGH INTENSITY ULTRASONIC PROCESSOR Watt Model TABLE OF CONTENTS

6 digital caliper with case

Norrsken Family Booklet

Unisense In Situ UniAmp Connector System

Resusci Anne Simulator

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Instruction Manual BA90 Precision Barometer

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

INFUSION SYSTEM (110V) (220V) USER S MANUAL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

NovelBright LED Illuminator

User s Guide Temperature Sensor Converter TSC-599

Advanced Test Equipment Rentals ATEC (2832)

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

Installation and Maintenance Instruction Manual

Installation and Operation Manual

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Budget Range Operators Handbook

PPS PORTABLE POWER SUPPLY

J Air and Water Kit Instructions Part# 02584

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

User s Guide. CO2 Controller for miniature incubators

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Transcription:

Research Grade Blood Pressure Transducer USER S MANUAL Research Grade Blood Pressure Transducer, 110 VAC/60 Hz Research Grade Blood Pressure Transducer, 220 VAC/50 Hz MA1 72-4496 MA1 72-4497 Publication 5408-002 REV1.0

WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good corporate citizen. As part of that commitment, we strive to maintain an environmentally conscious manufacturing operation. The European Union (EU) has enacted two Directives, the first on product recycling (Waste Electrical and Electronic Equipment, WEEE) and the second limiting the use of certain substances (Restriction on the use of Hazardous Substances, RoHS). Over time, these Directives will be implemented in the national laws of each EU Member State. Once the final national regulations have been put into place, recycling will be offered for our products which are within the scope of the WEEE Directive. Products falling under the scope of the WEEE Directive available for sale after August 13, 2005 will be identified with a wheelie bin symbol. Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8, medical devices (with the exception of implanted or infected products) and Category 9, monitoring and control instruments. Most of our products fall into either Category 8 or 9 and are currently exempt from the RoHS Directive. We will continue to monitor the application of the RoHS Directive to its products and will comply with any changes as they apply. Do Not Dispose Product with Municipal Waste Special Collection/Disposal Required

Table of Contents SUBJECT PAGE # Warranty & Repair Information 2 Theory of Operation 3 General Information Specifications 4 Amplifier/Power Supply 4 Front Panel Control 4 Electrical Output 5 Maintenance and Storage 5 Serial Number 5 Replacement Parts 5 Operation Installing the Dome 6 Liquid Connections 7 Filling and Purging of Air 8 Publication 5408-002 REV1.0 1

Warranty & Repair Information Serial Numbers All inquires concerning our product should refer to the serial number of the unit(s). Warranty Harvard Apparatus warranties the instrument(s) for a period of one year from date of purchase. At its option, Harvard Apparatus will repair or replace the unit(s) if it is found to be defective as to workmanship or material. This warranty does not extend to damage resulting from misuse, neglect or abuse, normal wear and tear, or accident. This warranty extends only to the original customer purchaser. IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states do not allow this limitation on an implied warranty, so the above limitation may not apply to you. If a defect arises within the one year warranty period, promptly contact Harvard Apparatus, Inc. 84 October Hill Road, Holliston, Massachusetts 01746-1371 using our U.S. only toll free number 1-800-272-2775 or dial (508) 893-8999. Goods will not be accepted for return unless an RMA (returned materials authorization) number has been issued by our customer service department. The customer is responsible for shipping charges. Please allow a reasonable period of time for completion of repairs, replacement and return. If the unit is replaced, the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Repair Facilities and Parts Harvard Apparatus stocks replacement and repair parts. When ordering, please describe parts as completely as possible, preferably using our part numbers. If practical, enclose a sample or drawing. We offer a complete reconditioning service. CAUTION: AVOID PLACING FORCE ON SENSING BUTTON WHEN DOME IS NOT INSTALLED. DO NOT ALLOW LIQUID TO ENTER SENSING HEAD SINCE SERIOUS DAMAGE WILL RESULT. TRANSDUCER SENSING HEAD MAY NOT SURVIVE BEING DROPPED. CAUTION: FOR RESEARCH USE ONLY. NOT FOR CLINICAL USE ON PATIENTS. 2 Publication 5408-002 REV1.0

Theory of Operation This Blood Pressure Transducer converts pressure to a proportional DC voltage value. A transparent plastic dome with two Luer-lock fittings contains the liquid whose pressure values are to be monitored. One of the Luer-lock fittings is used for connecting tubing to the source to be monitored and the other to purge air that would otherwise markedly degrade the transducer s dynamic (i.e. changing) response capabilities. The dome has an internal membrane that contacts a button on the sensing head. Liquid pressure within the dome acts through the membrane to produce a force upon the button. The force, in turn, acts against a rigid flexure-spring assembly to produce a small increment of motion which is measured by a differential capacitor circuit housed within the sensing head. From here, a cable carries the electrical signal to the power supply where the signal is further amplified and calibrated for the purposes of gain and offset. In addition, an external offset control will facilitate correction for static pressure. Sensing Head Dome Mounting Shaft Amplifier/Power Supply Signal Cable External Offset Control PRESSURE TRANSDUCER mm Hg OFFSET 12 Volt AC Wall Transformer 12 Volt AC Cable Figure 1. Research Grade Blood Pressure Transducer Publication 5408-002 REV1.0 3

General Information SPECIFICATIONS Input Internal Volume Compliance Two Luer-lock connectors on transparent polycarbonate plastic dome with internal silicone rubber membrane 300 µl, approx 14 µl of displacement/100 mm pressure including 30.5 cm (12 in) of standard 3 mm ID vinyl tubing -10 to +300 mmhg Sterilization Pressure Range User Selectable C and F Natural Frequency (Dry) > 500 Hz Membrane Pressure 300 mmhg without rupture and dome not installed Overload Pressure 3,000 mmhg with dome installed Output Voltage Factory set at 1.0 V/100 mmhg Digital Panel Meter Reads in mmhg (output voltage x 100) Offset Control Adjusts from +50 mmhg (0.5 V) to -100 mmhg (1.0 V) Carrier Frequency 2 MHz Sensing Head Dimensions 32 x 45 x 42 mm (1.26 x 1.77 x 1.65 in) Transducer Weight 70 g (2-1/2 oz) Amplifier/Power Supply a) The entire transducer is powered by a 12 volt AC wall transformer. b) There is no ON/OFF switch. The unit can remain powered, as shown on the digital meter, for the entire experiment. Front Panel Control The offset knob on the front panel is used to set a zero output voltage for any static pressure up to 100 mmhg. 4 Publication 5408-002 REV1.0

General Information Electrical Output a) A single BNC connection is located on the power supply for output connection. b) Output voltage is 1.0 V/100 mmhg pressure up to 300 mmhg. Output impedance is 2 kω for direct connection to all recorders. c) The digital panel meter, calibrated in mmhg, reads output voltage x 100. d) High, Low, and Offset trim pots are factory calibrated. DO NOT adjust. Figure 2. Electrical Output Maintenance and Storage a) No special precautions are required other than keeping a dome installed at all times and preventing liquids from entering the sensing head. b) When not in use, store in a clean, dry place. Serial Number The serial number is located on the power supply circuit board. Refer to this number in any correspondence. Replacement Parts Order # Product 72-4498 Replacement Dome, pkg. of 1 Publication 5408-002 REV1.0 5

Operation Installing the Dome Install the dome and make liquid connections. Take care to avoid cross-threading. The threads will engage smoothly, and finger tightening is adequate. Liquid Connections Orienting one of the Luer-lock fittings vertically will facilitate clearing air bubbles when filling with liquid. The dome may be installed empty or filled with liquid. In either case, make sure that the pressure in the dome does not exceed 300 mmhg. Otherwise, the membrane may rupture. Once installation is complete, the membrane is supported by the sensing button. Luer-Lock Fittings Signal Cable (To Amplifier/Power Supply) Dome Mounting Shaft Sensing Head Figure 3. Sensing Head 6 Publication 5408-002 REV1.0

Operation Filling and Purging Air The presence of trapped air bubbles anywhere within the liquid column will add compliance to the system and degrade the transducer s dynamic response capabilities. For this reason, it is recommended that the dome, tubing, and lumen be filled with a continuous flush until all bubbles have been cleared from the system. The dome cavity is shaped like a cone with one Luer-lock fitting at the tip (apex) and the other to the side (lateral). Flushing in the side and out the tip while held vertically allows the bubbles to rise. Tapping with a finger may be required to dislodge additional bubbles. Be sure to provide sufficient opening to allow fluid to escape and thereby prevent excessive pressure build-up which may rupture the dome. This precaution is especially important when filling an unmounted dome since the membrane is not supported and can withstand only 300 mmhg. Thus, installing the dome on the sensing head before filling is the safest procedure, but may not always be possible. Close off the filling tube with a stopcock or by pinching it. Publication 5408-002 REV1.0 7

U.S.A. Harvard Apparatus 84 October Hill Road Holliston, Massachusetts 01746 Phone (508) 893-8999 Toll Free (800) 272-2775 Fax (508) 429-5732 E-mail support@hbiosci.com Web www.harvardapparatus.com Canada Harvard Apparatus, Canada 6010 Vanden Abeele Street Saint Laurent, Quebec, H4S 1R9 Phone (514) 335-0792 Toll Free (800) 361-1905 Fax (514) 335-3482 E-mail sales@harvardapparatus.ca Web www.harvardapparatus.ca France Harvard Apparatus, S.A.R.L. 6 Avenue des Andes Miniparc Bat. 8 F-91952, Les Ulis Cedex Phone (33) 1-64-46-00-85 Fax (33) 1-64-46-94-38 E-mail info@harvardapparatus.fr Germany Hugo Sachs Elektronik Gruenstrasse 1 March-Hugstetten D-79232, Germany Phone (49) 0 7665.92.00.0 Fax (49) 0 7665.92.00.90 E-mail info@hugo-sachs.de Web www.hugo-sachs.de Sweden CMA Microdialysis AB Torshamnsgatan 30A SE-164 40 KISTA, Sweden Phone +46.8.470.10.00 E-mail cma@microdialysis.se Web www.microdialysis.com Spain Panlab S.L.U. C/ Energia, 112 08940 Cornellà (Barcelona), Spain Phone +46 8 470 10 00 Fax +46 8 470 10 50 E-mail info@panlab.com Web www.panlab.com United Kingdom Biochrom 1020 Cambourne Business Park Cambourne, Cambridge, CB23 6DW UK Phone (44) 1223.423.723 Fax (44) 1223.420.164 E-mail enquiries@biochrom.co.uk Web www.biochrom.co.uk China Harvard Apparatus China Room 1902E 19F, Building B Zhong Shan Plaza 1065 West Zhong Shan Road Changning District Shanghai, China 200051 Phone +86 21 2230 5128