CATALOGUE EXTRACT SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC

Similar documents
London Underground - Section 12 approved Switch Disconnectors

Zelio Relays RSL Slim Interface Plug-In Relays

TERMINAL BLOCK SUMMARY

Position switches FP series

Meta-MEC Manual Motor Starters

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Prewired position switches FA series

Electromechanical pressure switches

CMC Series Moulded Case Circuit Breaker Cielo Electric

Junction Boxes Series 8118

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

Prewired position switches FA series

Meta-MEC Manual Motor Starters

TeSys protection components

Circuit breakers PR 60

PRODUCT SPECIFICATION

CFSW. Hinges with built-in safety multiple switch

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Conductor Bushings Series 8174

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

S(U)200 series SU200M, SU200MR, and S200UDC UL 489 series

CFSW. Hinges with built-in safety multiple switch

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

Pushbuttons and Indicating Lights

F series Foot Switches

METEOR LSR0640 UNDERWATER POOL LIGHT. Operating Instructions

Current transformers Measurement devices from 5 to 5000 A

[Instruments for vacuum measurement, checking and adjustment] 3

Aquacom Diving Equipment

Miniature controls. Contactors. Overload relays. Starters. Control relays

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

ibridge and ibridge Ultra

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

Differential pressure switch MP 54, MP 55 and MP 55A

Protection of motor circuits

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

SonoMeter 30 Energy Meters

MaxSB - Low Voltage Switchboard

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

Pressure Switch for gas and air

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Electromechanical pressure switches

Installation, use and maintenance instructions. Gas burner (5)

Pressure Switch for gas and air

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Guidelines to the standard IEC60601

Dräger P7 Pressure, Leak and Leak Rate Measurement

Pneumatic spool valve islands

e2c 20 - easy to connect

Pressure switches for air and water CS

Alhambra Arabic design, British engineering

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Pressure switch for gas and air

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

HydroCOM: High energy savings and excellent controllability

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Galaxy Shore Connection 500 kva Installation 04/

Relative pressure switch type 521

RPS900W Redundant Power Supply. Installation Guide.

Torque Tube TB300 Digital Transmitters

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

GENERAL APPLICATION NOTES

Emergency Stop Devices/Rope Pull Switches

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Gas Pressure Switch for DMV safety shutoff valves

Selection of Electrical PPE Tables

POWR-BLOKS Distribution/Splicer Blocks and Covers

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Operating Instructions

Differential pressure controls, Type MP 54, 55 and 55A

GAS FUEL VALVE FORM AGV5 OM 8-03

Pressure Switch for gas and air GGAO-A4

Max Sort Sortation Option - Letters

Short Form Brochure. Terminal Blocks &Accessories

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Gas Pressure Switch for DMV safety shutoff valves

Operating Instructions

C645A-E Pressure Switches

Remote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004

Operating Instructions Rope Pull Switches RPS...

Differential pressure switch / Lube oil protection control MP 54 and MP 55

German Machine Tool Industry - Key Figures

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Technical Data. Dimensions

Gas Pressure Switch for DMV safety shutoff valves

Transcription:

2013 2014 CATALOGUE EXTRACT SIRCO PV Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC 60947-3

Load break switches sirco-pv_058_a_1_cat SIRCO PV UL98B sirco-pv_059_a_1_cat Strong points > Patented switching technology. > Positive break indication. > Up to 1000 VDC as per characteristics by UL98B. > Up to 1500 VDC as per characteristics by IEC 60947-3. > Suitable for use in accordance with NEC Art. 690 2011 issue. Conformity to standards Function SIRCO PV UL98B are manually operated multipole load break switches. They make and break on load and provide safety isolation for any PV circuit up to 1000 VDC (as per UL98B standard). They comply with NEC Art. 690 (US National Electrical Code) concerning photovoltaic installations. They are compliant for use within solar inverters and enclosures governed by UL1741 standard. SIRCO PV are extremely durable switches that have been tested and approved for use in the most demanding environments. They have been designed and tested for all types of applications such as earthing, floating or bipolar. > UL98B Guide WHVA, file E346418 > CSA C22.2#4, Class 4651-02, file 112964 > NEC Art 690 Issue 2011 > IEC 60947-3 Approvals and certifications (1) Advantages Performance A glass fibre reinforced polyester break chamber with an arc extinguishing system provides a patented safety disconnection system offering rapid extinguishing of the electric arc up to 1500 VDC with current interruption of up to 2000 A. Back-to-back double load break switch Back-to-back double switches enables: - simultanuous on load operation of two switches with a single handle, - a compact solution when connecting two separate photovoltaic circuits compared with the use of two separate switches, - easy connection, - voltages above 1000 VDC are safety broken by the use of two poles in. (1) Product reference on request. 2 Catalogue Extract 2013-2014

Typical PV architecture The SIRCO PV range provides safe disconnection and isolation at all levels within your PV installation. SIRCO-PV 054 A The SOCOMEC solutions Combiner box LEVEL OF INSTALLATION SOCOMEC SOLUTIONS SIRCO PV One circuit 100 to 400 A up to 1500 VDC Recombiner box SIRCO PV 4 circuits 100 to 400 A at 1000 VDC 2 circuits 100 to 400 A at 1500 VDC Inverter SIRCO PV One circuit 100 to 2000 A at 1000 VDC 100 to 900 A at 1500 VDC Catalogue Extract 2013-2014 3

References 1000 VDC - Back plate mounting Rating (A) poles Switch body External handle 1 PV circuit 100 A B4 27PV 2009 200 A B4 27PV 2019 250 A B4 2 P 27PV 2024 325 A B5 27PV 2032 400 A B5 27PV 2039 600 A B6 27PV 4060 800 A B7 27DC 4081 4 P 1200 A B7 DS 27DC 4121 2000 A B7 DS 27DC 4201 100 A B4 DS 2 PV circuits 27PV 5009 250 A B4 DS 27PV 5024 325 A B5 27PV 4032 4 P 400 A B5 27PV 4039 600 A B6 DS 27PV 8060 800 A B7 DS 8 P 27DC 8081 1200 A B7 DS 27DC 8101 S2 type Black 1, 3R, 12 142F 2111 (1) Red/Yellow 1, 3R, 12 142G 2111 (1) Black 4, 4X 142D 2111 (1) Red/Yellow 4, 4X 142E 2111 (1) S3 type Black 4, 4X 143D 3111 (1) Red/Yellow 4, 4X 143E 3111 (1) S4 type Black 4, 4X 144D 3111 (1) Red/Yellow 4, 4X 144E 3111 (1) V1 type Black 3R, 12 2799 7145 S2 type Black 1, 3R, 12 142F 2111 (1) Red/Yellow 1, 3R, 12 142G 2111 (1) Black 4, 4X 142D 2111 (1) Red/Yellow 4, 4X 142E 2111 (1) V1 type Black 3R, 12 2799 7145 Shaft for external handle 200 mm 7.9 inches 1400 1020 320 mm 12.6 inches 1400 1032 400 mm 15.7 inches 1400 1040 (2) 200 mm 7.9 inches 1401 1520 320 mm 12.6 inches 1401 1532 400 mm 15.7 inches 1401 1540 (2) 320 mm 12.6 inches 4199 3018 200 mm 7.9 inches 1400 1020 320 mm 12.6 inches 1400 1032 400 mm 15.7 inches 1400 1040 (2) 320 mm 12.6 inches 4199 3018 Bridging bar (single polarity switching) 1x 2709 1020 1x 2709 1041 2x 2709 1041 2x 2709 0062 2x 2709 0081 2x 2709 0121 2x 2709 1020 4x 2709 1020 2x 2709 0027 2x 2709 0045 4x 2709 0062 4x 2709 0121 4 PV circuits 350 A B5 DS 8 P 27PV 8039 (1) Defeatable handle. (2) Shaft guide reference 1429 0000 is required for shaft length over 15.7 inches (400mm). S3 type Black 4, 4X 143D 3111 (1) Red/Yellow 4, 4X 143E 3111 (1) 200 mm 7.9 inches 1401 1520 320 mm 12.6 inches 1401 1532 400 mm 15.7 inches 1401 1540 (2) 4x 2709 0045 4 Catalogue Extract 2013-2014

1500 VDC - Back plate mounting Rating (A) poles Switch body External handle 1 PV circuit Shaft for external handle Bridging bar (single polarity switching) 275 A B5 27PV 3026 325 A B5 3 P 27PV 3032 400 A B5 27PV 3039 S2 type Black 1, 3R, 12 142F 2111 (1) Red/Yellow 1, 3R, 12 142G 2111 (1) Black 4, 4X 142D 2111 (1) Red/Yellow 4, 4X 142E 2111 (1) 200 mm 7.9 inches 1400 1020 320 mm 12.6 inches 1400 1032 400 mm 15.7 inches 1400 1040 (2) 2x 2709 0027 2x 2709 0045 600 A B6 DS 27PV 8060 4x 2709 0062 800 A B7 DS 8 P 27DC 8081 V1 type Black 3R, 12 2799 7145 320 mm 12.6 inches 4199 3018 4x 2709 0121 1000 A B7 DS 27DC 8101 2 PV circuits 275 A B5 DS 6 P 27PV 6026 350 A B5 DS 27PV 6039 S3 type Black 4, 4X 143D 3111 (1) Red/Yellow 4, 4X 143E 3111 (1) 200 mm 7.9 inches 1401 1520 320 mm 12.6 inches 1401 1532 400 mm 15.7 inches 1401 1540 (2) 4x 2709 0027 4x 2709 0045 (1) Defeatable handle. (2) Shaft guide reference 1429 0000 is required for shaft length over 15.7 inches (400mm). Catalogue Extract 2013-2014 5

Accessories External operation Use In a combiner box, located close to the solar cell strings, or located close to the inverter, we recommend to use a door interlocked external handle for its safety features. Door interlocked external operation handles include an escutcheon, are padlockable and must be utilised with an extension shaft. Example The locking function of the enclosure in the "ON" position will force the operator to safely disconnect and isolate the solar cell strings prior to any intervention. Opening the door when the switch is on "ON" position is possible by defeating the locking function using a tool (authorized persons only). The interlocking function is restored when the door is closed back. acces_150_a_2_cat S2 type handle acces_236_a_2_cat Reinforced S2 type handle Handle type Handle colour NEMA degree of protection Reference B4 B5 - B4 DS S2 Black 142F 2111 1, 3R, 12 B4 B5 - B4 DS S2 Red/Yellow 142G 2111 B4 B5 - B4 DS S2 Black 142D 2111 B4 B5 - B4 DS S2 Red/Yellow 142E 2111 B5 DS - B6 S3 Black 143D 3111 4, 4X B5 DS - B6 S3 Red/Yellow 143E 3111 B7 S4 Black 144D 3111 B7 S4 Red/Yellow 144E 3111 B6 DS B7 DS V1 Black 1, 3R, 12 2799 7145 acces_166_a_2_cat acces_152_a_2_cat access_189_a_2_cat S3 type handle S4 type handle V1 type handle Shaft for external handle Use Standard lengths: - 7.9 in / 200 mm, - 12.6 in / 320 mm, - 15.7 in / 400 mm. Other lengths: please consult us. acces_144_b_1_cat Handle type Dimension (inches) Dimension X (mm) Length (inches) Length (mm) Reference B4 S2 6 11.6 150 295 7.9 200 1400 1020 B4 S2 6 16.3 150 415 12.6 320 1400 1032 B4 S2 6 19.4 150 495 15.7 400 1400 1040 B5 S2 8 12.9 203 328 7.9 200 1400 1020 B5 S2 8 17.6 203 448 12.6 320 1400 1032 B5 S2 8 20.7 203 525 15.7 400 1400 1040 B6 S3 8.70 13.50 220 343 7.9 200 1401 1520 B6 S3 8.70 18.23 220 463 12.6 320 1401 1532 B6 S3 8.70 21.38 220 543 15.7 400 1401 1540 B7 S4 12 14.4 305 366 7.9 200 1401 1520 B7 S4 12 19.1 305 485 12.6 320 1401 1532 B7 S4 12 22.2 305 564 15.7 400 1401 1540 B4 DS S2 12 14.3 305 363 7.9 200 1400 1020 B4 DS S2 12 19 305 483 12.6 320 1400 1032 B4 DS S2 12 22.10 305 561 15.7 400 1400 1040 B5 DS S3, S4 16 18.4 406 467 7.9 200 1401 1520 B5 DS S3, S4 16 23.1 406 589 12.6 320 1401 1532 B5 DS S3, S4 16 26.3 406 668 15.7 400 1401 1540 B6 DS V1 20 28.1 508 714 12.6 320 4199 3018 B6 DS V1 20 31.3 508 795 15.7 400 4199 3019 B7 DS V1 20 28.1 508 714 12.6 320 4199 3018 B7 DS V1 20 39.4 508 795 15.7 400 4199 3019 X acces_369_a_1_cat acces_202_a_1_x_cat 6 Catalogue Extract 2013-2014

S type handle adapter Use For handles S2, S3 and S4. Dimensions Increases the distance between the handle grip and the door by 12 mm, for better handling. Colour NEMA degree of protection To be ordered in multiples of Reference Black 1, 3R, 12 10 1493 0000 acces_187_a_3_cat Alternative S type handle cover colours Use For handles S2, S3 and S4. Handle colour Other colours: please consult us. To be ordered in multiples of Handle type Reference Light grey S2, S3 50 1401 0001 Dark grey S2, S3 50 1401 0011 Light grey S4 50 1401 0031 Dark grey S4 50 1401 0041 acces_198_a_3_cat Auxiliary contact Use Pre-break and signalling of positions 0 and I: - 1 to 2 NO/NC auxiliary contacts, - 1 to 2 low level NO/NC auxiliary contacts. Electrical characteristics A300. NO/NC contact Position AC Type Reference B4 B7 1 contact 2799 0021 B4 B7 2 contacts NO/NC 2799 0022 B4 DS B7 DS 1 contact 4159 0021 Low level NO/NC auxiliary contacts Position AC Type Reference B4 B7 1 contact 2799 0121 B4 B7 2 contacts NO/NC 2799 0122 B4 DS B7 DS 1 contact 4199 0022 acces_076_a_1_cat Terminal screen Use Top or bottom protection against direct contact with terminals or connection parts. No. of pole Position Pack Reference B4 2 P top or bottom 1 unit 2798 3021 B5 3 P top or bottom 1 unit 2798 3041 B5 4 P top or bottom 1 unit 2798 4041 B6 4 P top or bottom 1 unit 2798 4061 B7 4 P top or bottom 1 unit 2798 4121 B4 DS 2 P top or bottom 1 unit 4158 3021 B5 DS 6 P top or bottom 1 unit 4158 3041 B5 DS 8 P top or bottom 1 unit 4158 4041 B6 DS 8 P top and bottom 2 units 2798 8061 B7 DS 8 P top or bottom 1 unit 2798 4121 acces_079_a_1_cat Catalogue Extract 2013-2014 7

Accessories (continued) Bridging bars for connecting poles in Use The bridging bars will make easy the connection of the poles in, allowing the following configurations (1). (1) Other connections: refer to mounting instructions. 1000 VDC Rating (A) Quantity to be ordered to connect two poles in Fig. Reference 1 PV circuit B4 100 1 1 2709 1020 B4 200 1 1 2709 1020 B4 250 1 1 2709 1020 B5 325 1 1 2709 1041 B5 400 2 2 2709 1041 B6 600 2 3 2709 0062 B7 800 2 3 2709 0081 B7 1200 2 3 2709 0121 B7 DS 2000 2 3 2709 0121 2 PV circuits B4 DS 100 2 1 2709 1020 B4 DS 250 4 4 2709 1020 B5 325 2 5 2709 0027 B5 400 2 6 2709 0045 B5 400 2 6 2709 0045 B6 DS 600 4 3 2709 0062 B7 DS 800 4 3 2709 0121 B7 DS 1200 4 3 2709 0121 4 PV circuits B5 DS 350 2 6 2709 0045 1500 VDC Rating (A) Quantity to be ordered to connect two poles in Fig. Reference 1 PV circuit B5 275 2 5 2709 0027 B5 325 2 5 2709 0027 B5 400 2 6 2709 0045 B6 DS 600 4 3 2709 0062 B7 DS 800 4 3 2709 0121 B7 DS 1000 4 3 2709 0121 2 PV circuits B5 DS 275 4 5 2709 0027 B5 DS 350 4 6 2709 0045 8 Catalogue Extract 2013-2014

Bridging bars for connecting poles in (continued) acces_381_a_1_x_cat Fig. 1 acces_382_a_1_x_cat Fig. 2 acces_374_a_1_x_cat Fig. 4 acces_383_a_1_x_cat Fig. 3 acces_386_a_1_x_cat acces_378_a_1_x_cat Fig. 5 Fig. 6 Catalogue Extract 2013-2014 9

Accessories (continued) Cage terminals Use For the connection of bare copper cables onto the terminals (without lugs). Optional fan out kit for ratings of 800 to 1200 A for connecting several cables to the switch. Rating max (A) Numbrer and size of cables Max. number of connections per terminal Type of cable Quantity Reference B4 - B4 DS 100 250 1 conductor (#6-300MCM) 1 Cu / Al 2 lugs 3954 2020 B4 - B4 DS 100 250 2 conductors (#4-2/0) 1 Cu / Al 2 lugs 3954 2025 B4 - B4 DS 325 400 1 conductor (#2-600MCM) 1 Cu / Al 2 lugs 3954 2040 B4 - B4 DS 325 400 2 conductors (#6-350MCM) 1 Cu / Al 2 lugs 3954 2041 B6 - B6 DS 600 2 conductors (#2-600MCM) 1 Cu / Al 2 lugs 3954 2060 B7 800 1200 2 conductors (#2-600MCM) 2 Cu / Al 2 lugs 3954 2060 B7 800 1200 2 conductors (#2-600MCM) 3 (1) Cu / Al 3 lugs 3954 3060 B7 DS 2000 2 conductors (#2-600MCM) 2 (2) Cu / Al 2 lugs 3954 2060 B7 DS 2000 2 conductors (#2-600MCM) 3 (3) Cu / Al 3 lugs 3954 3060 (1) Order a fan out kit reference 2709 1203 for connecting 3 connectors per terminal (6 in total for the switch). (2) 2 connectors per terminal with the connection kit 2729 1200. (3) 3 connectors per terminal with the connection kits 2729 1201 and 2709 1202. ul_032_a Copper bar connection kits Use To allow connection between the two power terminals from a same pole for 2000 A ratings. (Fig. 1, Fig. 2 and Fig. 3) Fig. 1 Top or bottom flat connection Rating (A) Figure B7 DS Quantity to order per pole terminals Reference 800 1000 1 1 2 2729 1200 800 1000 2 1 3 2729 1202 2000 1 1 2 2729 1200 2000 2 1 3 2729 1202 acces_312_b_1_x_cat Fig. 2 Fig. 3 Top or bottom edgewise connection Rating (A) Figure Quantity to order per pole terminals Reference B7 DS 800 2000 3 1 3 2729 1201 acces_313_b_1_x_cat acces_314_b_1_x_cat 10 Catalogue Extract 2013-2014

Characteristics as per UL98B standards Rating (A) 100 A 200 A circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 100 2 P 2 P B4 200 2 P 2 P B4 2 circuits 600 VDC 100 1 P 2 P B4 130 1 P 2 P B4 2 circuits 1000 VDC 100 2 P 4 P B4 DS 200 2 P 4 P B4 DS 4 circuits 600 VDC 100 1 P 4 P B4 DS 130 1 P 4 P B4 DS Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) 10 (1) Connection terminals Min. connection wire range/ AWG #6 #6 Max. connection wire range/ AWG 300MCM 300MCM Mechanical characteristics Durability (number of operating cycles) 10 000 10 000 Operating effort (lbs.in/nm) 88.5/10 88.5/10 Auxiliary contact Electrical characteristics A300 A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 160 250 Thermal current at 50 C (A) 160 250 Thermal current at 60 C (A) 160 250 Rated insulation voltage U i (V) 1500 1500 Rated impulse withstand voltage U imp (kv) 12 12 circuits Rated voltage (A) (1) Without fuse during 50 ms. the switch (A) the switch 1 circuit 1000 VDC 160 2 P 2 P B4 250 2 P 2 P B4 1 circuit 1500 VDC 160 4 P 4 P B4 DS 250 4 P 4 P B4 DS 2 circuits 1000 VDC 160 2 P 4 P B4 DS 250 2 P 4 P B4 DS 4 circuits 600 VDC 125 1 P 4 P B4 DS 160 1 P 4 P B4 DS Catalogue Extract 2013-2014 11

Characteristics (continued) as per UL98B standards Rating (A) 250 A 275 A circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 250 2 P 2 P B4 275 2 P 2 P B5 2 circuits 600 VDC 130 1 P 2 P B4 215 1 P 2 P B5 2 circuits 1000 VDC 250 2 P 4 P B4 DS 275 2 P 4 P B5 4 circuits 600 VDC 130 1 P 4 P B4 DS 215 1 P 4 P B5 4 circuits 1000 VDC - - - - 215 2 P 8 P B5 DS 6 circuits 600 VDC - - - - 215 1 P 6 P B5 DS 8 circuits 600 VDC - - - - 215 1 P 8 P B5 DS Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) 10 (1) Connection terminals Min. connection wire range/ AWG #6 2x#6 Max. connection wire range/ AWG 300MCM 600MCM Mechanical characteristics Durability (number of operating cycles) 10 000 6 000 Operating effort (lbs.in/nm) 88.5/10 128.3/14.5 Auxiliary contact Electrical characteristics A300 A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 315 275 Thermal current at 50 C (A) 315 275 Thermal current at 60 C (A) 315 275 Rated insulation voltage U i (V) 1500 1500 Rated impulse withstand voltage U imp (kv) 12 12 circuits Rated voltage (A) (1) Without fuse during 50 ms. the switch (A) the switch 1 circuit 1000 VDC 315 2 P 2 P B4 275 2 P 2 P B5 1 circuit 1500 VDC 315 4 P 4 P B4 DS 275 2 P 3 P B5 2 circuits 1000 VDC 315 2 P 4 P B4 DS 275 2 P 4 P B5 4 circuits 600 VDC 160 1 P 4 P B4 DS 275 1 P 4 P B5 4 circuits 1000 VDC - - - - 275 2 P 8 P B5 DS 6 circuits 600 VDC - - - - 275 1 P 6 P B5 DS 8 circuits 600 VDC - - - - 275 1 P 8 P B5 DS 12 Catalogue Extract 2013-2014

as per UL98B standards Rating (A) 325 A 350 A circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 325 2 P 2 P B5 - - - - 2 circuits 600 VDC 215 1 P 2 P B5 - - - - 2 circuits 1000 VDC 325 2 P 4 P B5 350 3 P 6 P B5 DS 4 circuits 600 VDC 215 1 P 4 P B5 - - - - 4 circuits 1000 VDC 325 2 P 8 P B5 DS 350 2 P 8 P B5 DS 6 circuits 600 VDC 215 1 P 6 P B5 DS 215 1 P 6 P B5 DS 8 circuits 600 VDC 215 1 P 8 P B5 DS 215 1 P 8 P B5 DS Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) 10 (1) Connection terminals Min. connection wire range/ AWG 2x#6 2x#6 Max. connection wire range/ AWG 600MCM 600MCM Mechanical characteristics Durability (number of operating cycles) 6 000 6 000 Operating effort (lbs.in/nm) 128.3/14.5 128.3/14.5 Auxiliary contact Electrical characteristics A300 A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 400 500 Thermal current at 50 C (A) 400 500 Thermal current at 60 C (A) 400 500 Rated insulation voltage U i (V) 1500 1500 Rated impulse withstand voltage U imp (kv) 12 12 circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 400 2 P 2 P B5 - - - - 2 circuits 1000 VDC 400 2 P 4 P B5 500 3 P 6 P B5 DS 4 circuits 600 VDC 275 1 P 4 P B5 - - - - 4 circuits 1000 VDC 400 2 P 8 P B5 DS 500 2 P 8 P B5 DS 6 circuits 600 VDC 275 1 P 6 P B5 DS 275 1 P 6 P B5 DS 8 circuits 600 VDC 275 1 P 8 P B5 DS 275 1 P 8 P B5 DS (1) Without fuse during 50 ms. Catalogue Extract 2013-2014 13

Characteristics (continued) as per UL98B standards Rating (A) 400 A 600 A circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 400 2 P 2 P B5 600 4 P 4 P B6 2 circuits 600 VDC 215 1 P 2 P B5 600 3 P 6 P B6 DS 2 circuits 1000 VDC 400 2 P 4 P B5 600 4 P 8 P B6 DS 4 circuits 600 VDC 215 1 P 4 P B5 - - - - Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) 10 (1) Connection terminals Min. connection wire range/ AWG 2x#6 2x#2 Max. connection wire range/ AWG 600MCM 2 x 600MCM Mechanical characteristics Durability (number of operating cycles) 6 000 6 000 Operating effort (lbs.in/nm) 128.3/14.5 327.5/37 Auxiliary contact Electrical characteristics A300 A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 500 800 Thermal current at 50 C (A) 500 - Thermal current at 60 C (A) 500 - Rated insulation voltage U i (V) 1500 1500 (2) Rated impulse withstand voltage U imp (kv) 12 12 circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 500 2 P 2 P B5 800 4 P 4 P B6 1 circuit 1500 VDC 500 2 P 3 P B5 800 8 P 8 P B6 DS 2 circuits 1000 VDC 500 2 P 4 P B5 800 4 P 8 P B6 DS 4 circuits 600 VDC 275 1 P 4 P B5 - - - - (1) Without fuse during 50 ms. (2) 1200 VDC for B6. 14 Catalogue Extract 2013-2014

as per UL98B standards Rating (A) 800 A 1200 A circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 800 4 P 4 P B7 1200 4 P 4 P B7 2 circuits 600 VDC 800 3 P 6 P B7 DS 1200 3 P 6 P B7 DS 2 circuits 1000 VDC 800 4 P 8 P B7 DS 1200 4 P 8 P B7 DS Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) 10 (1) Connection terminals Min. connection wire range/ AWG 4x#2 4x#2 Max. connection wire range/ AWG 6x 600MCM (2) 6x 600MCM (2) Mechanical characteristics Durability (number of operating cycles) 3 500 3 500 Operating effort (lbs.in/nm) 495.7/56 663.9/75 Auxiliary contact Electrical characteristics A300 A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 1000 1400 Rated insulation voltage U i (V) 1500 (3) 1500 (3) Rated impulse withstand voltage U imp (kv) 12 12 circuits Rated voltage (A) the switch (A) the switch 1 circuit 1000 VDC 1000 4 P 4 P B7 1400 4 P 4 P B7 DS 1 circuit 1500 VDC 1000 8 P 8 P B7 DS 1000 8 P 8 P B7 DS 2 circuits 1000 VDC 1000 4 P 8 P B7 DS 1000 4 P 8 P B7 DS (1) Without fuse during 50 ms. (2) Maximum 6 x 600MCM with fan out kit 2729 1203. (3) 1200 VDC for B7. Catalogue Extract 2013-2014 15

Characteristics (continued) as per UL98B standards Rating (A) circuits Rated voltage (A) 2000 A the switch 1 circuit 1000 VDC 2000 8 P 8 P B7 DS Short-circuit capacity at 1000 VDC (any circuit breaker) Prospective short-circuit current (ka rms DC) 10 (1) Connection terminals Min. connection wire range/ AWG 4x#2 Max. connection wire range/ AWG 6x 600MCM (2) Mechanical characteristics Durability (number of operating cycles) 3 500 Operating effort (lbs.in/nm) 663.9/75 Auxiliary contact Electrical characteristics A300 as per IEC 60947-3 standard Thermal current at 40 C (A) 2200 Rated insulation voltage U i (V) 1200 Rated impulse withstand voltage U imp (kv) 12 circuits Rated voltage (A) the switch 1 circuit 1000 VDC 2000 8 P 8 P B7 DS (1) Without fuse during 50 ms. (2) Maximum 6 x 600MCM with fan out kit 2729 1203. 16 Catalogue Extract 2013-2014

Dimensions (in / mm) B4-B5 J1 J 0.29 7.5 Ø 0.35 Ø 9 Ø 0.27 Ø 7 Y 0.53 13.3 B4 0.98 25 Ø 0.43 Ø 11 K K1 H 1.18 30 B B5 0.79 20 1.77 45 H H1 Ø 0.51 Ø 13 sirco-ul_054_a_1_x_cat J2 J3 A C 1.96 50 No. of pole Measurement A B C H H1 max. J J1 J2 J3 K K1 Y B4 2 P inches 7.08 6.30 3.74 5.21 4.21 6.30 2.16-3.94 5.31 1.89 1.51 B4 2 P mm 180 160 95 132.5 107 160 55-100 135 48 38.5 B5 2 P inches 9.05 1.23 4.92 8 6.53 8.26 2.95-5.12 7.67 2.65 2.08 B5 2 P mm 230 260 128 203 166 210 75-130 195 67.5 53 B5 3 P inches 9.05 10.23 4.98 8 6.53 8.26 2.95 2.56-7.67 2.65 2.02 B5 3 P mm 230 260 126.5 203 166 210 75 65-195 67.5 51.5 B5 4 P inches 11.41 10.23 4.98 8 6.53 10.63 5.31 2.56-7.67 2.65 2.02 B5 4 P mm 290 260 126.5 203 166 270 135 65-195 67.5 51.5 B4 DS -B5 DS J1 J 0.29 7.5 Ø 0.35 Ø 9 Ø 0.27 Ø 7 Y Y1 C 0.53 13.3 B4 DS 0.98 25 Ø 0.43 Ø 11 K1 H 1.18 30 B5 DS B K 0.79 20 1.77 45 H H2 Ø 0.51 Ø 13 sirco-ul_055_a_1_x_cat A J3 J2 H1 1.96 50 No. of pole Measurement A B C H H1 H1 max. J J1 J2 J3 K K1 Y Y1 B4 DS 4 P inches 9.60 6.30 6.37 5.08 6.93 4.21 6.30 1.37-3.93 5.31 2.65 1.51 5.21 B4 DS 4 P mm 244 160 162 129 176 107 160 35-100 135 67.5 38.5 132.5 B5 DS 6 P inches 11.85 10.23 9.39 8 6.51 6.53 6.26 1.37 2.56-7.67 2.70 2.02 7.44 B5 DS 6 P mm 301 260 238.5 203 165.5 166 210 35 65-195 68.5 51.5 189 B5 DS 8 P inches 14.21 10.23 9.39 8 6.51 6.53 10.63 1.37 2.56-7.67 2.70 2.02 7.44 B5 DS 8 P mm 361 260 238.5 203 165.5 166 270 35 65-195 68.5 51.5 189 Catalogue Extract 2013-2014 17

Dimensions (in / mm) (continued) B6 J C J1 Y 0.82 21 1.97 50 Ø 0.41 Ø 10.5 H K2 K1 K B H 1.95 49.5 sirco-ul_056_a_1_x_cat 2.75 70 Ø 0,35 Ø 9 3.15 80 A H1 B6 No. of pole Measurement A B C H H1 J J1 K K1 K2 Y 4 P inches 14.17 13.38 5.47 10.63 5.70 13.19 6.59 6.88 2.34 1.10 1.83 4 P mm 630 340 139 270 145 335 167.5 175 59.5 28 46.5 B6 DS C J J1 Y Y1 0.82 21 1.97 50 Ø 0.41 Ø 10.5 sirco-ul_057_a_1_x_cat B K K1 H H 1.95 49.5 2.75 70 A 3.15 80 H1 No. of pole Measurement A B C H H1 J J1 K K1 Y Y1 B6 ds 8 P inches 18.34 13.8 14.56 10.63 13.66 13.18 2.02 9.84 4.92 2.61 9.98 8 P mm 466 340 370 270 347 335 51.5 250 125 66.5 253.5 18 Catalogue Extract 2013-2014

B7 J1 J 1.73 44 0.82 20.85 3.54 90 Y C Ø 0.41 Ø 10.5 B7 DS C J1 J 1.73 44 0.82 20.85 3.54 90 Y1 Ø 0.41 Ø 10.5 B K K1 0.35 9 H H H H2 K2 K sirco-ul_058_a_1_x_cat B K1 H 4.72 120 A H1 B7 No. of pole Measurement A B C H H1 H2 J J1 K K1 K2 Y 4 P inches 20.19 11.33 7.97 11.89 8.30 8.01 18.38 9.19 9.84 3.82 1.10 4.23 sirco-ul_061_a_1_x_cat 4 P mm 513 288 200 302 211 203.5 467 233.5 250 97 28 107.5 4.72 120 A H1 No. of pole Measurement A B C H H1 J J1 K K1 Y Y1 B7 DS 8 P inches 23.95 11.33 13.11 11.85 15.31 18.38 2.02 9.84 4.92 4.23 11.55 8 P mm 608.5 288 333 301 389 467 51.5 250 125 107.5 293.5 Catalogue Extract 2013-2014 19

Dimensions for external handles (in / mm) B4 - B4 DS - B5 Handle type S2 type Front operation Direction of operation 0 Door drilling 40 Ø 78 90 4 Ø 7 poign_013_a_1_gb_cat 45 125 I Ø 37 28 B5 DS - B6 Front operation Handle type Direction of operation Door drilling S3 type Ø 78 90 Ø 37 0 40 poign_035_a_1_gb_cat 61 210 28 4 Ø 7 20 Catalogue Extract 2013-2014

B7 Handle type S4 type Front operation Direction of operation Door drilling I Ø78 90 Ø 37 poign_036_a_1_gb_cat 350 0 28 4 Ø 7 60 40 B6 DS - B7 DS Handle type V1 type Front operation Direction of operation I Door drilling 50 4 Ø 6,5 poign_037_a_1_gb_cat 122 545 0 Ø 31 50 Catalogue Extract 2013-2014 21

Bridging bars (in / mm) B4 - B4 DS 2709 1020 12.5 100 ±0.3 B5 - B5 DS 2709 1041 Ø13 sirco-ul_062_a_1_x_cat 43.5 27 Ø11 135 125 71 3 19 ±0.2 22.5 130 ±0.3 175 5 50 sirco-ul_062_a_1_x_cat 2709 0045 B6 - B6 DS 110 2709 0062 Ø13 R 6 sirco-ul_047_b_1_x_cat sirco-ul_048_b_1_x_cat 3.44 87.5 0.55 3.94 14 100 B7 2709 0081 0.98 3.15 25 80 0.98 25 Ø 0.43 Ø 11 0.2 5 Ø 0.41 Ø 10.5 1.02 1.49 26 8.27 38 0.315 210 8 1.69 43 14 ±0.2 6 10 2709 0027 45 19 ±0.35 26 22.5 65 ±0,2 46.5 17 22.5 65 ± 0.3 5 53 Ø13 5 90 57.06 sirco-ul_062_a_1_x_cat sirco-ul_062_a_1_x_cat B7 - B7 DS 2709 0121 4.82 122.5 Ø 0.41 Ø 10.5 sirco-ul_049_b_1_x_cat 1.02 1.49 26 8.27 38 0.315 210 8 2.8 71 22 Catalogue Extract 2013-2014

Mounting orientation All frames B4 DS - B5 DS B6 DS - B7 DS Terminal lugs (in / mm) 100 to 250 A 100 to 250 A 1.52 38.8 1 25 0.45 Ø11.6 1.26 32 1.476 0.63 37.5 16 0.27 7 1.3 35 2.8 71.5 Ø 0.4 Ø 4.7 0.63 15.88 sirco_115_b_1_x_cat sirco-ul_028_a_1_x_cat 1.12 28.6 sirco-ul_029_a_1_x_cat sirco-ul_030_a_1_x_cat 400 A sirco-ul_038_a_1_x_cat 0.2 5 0.79 20 sirco-ul_010_a_1_x_cat 1.8 46 0.44 11.13 300MCM 2/0 600MCM 400 A 600 to 2000 A 2.88 2 73.15 51 0.53 13.46 1.49 38 1.94 49.30 0.40 Ø10.2 1.19 30.23 3.15 80 sirco-ul_026_b_1_cat 0.25 6.35 1.25 31.75 sirco_116_b_1_x_cat 2.87 73 2 x 350MCM 2 x 600MCM Catalogue Extract 2013-2014 23

Socomec worldwide In north AMERICA USA, CANADA & MEXICO SOCOMEC Inc 222 Third Street - Suite 1221 Cambridge, MA 02142 USA Tel. 617 245 0447 - Fax 617 245 0437 info.us@socomec.com www.socomec.us In western EUROpE In EASTERn EUROpE, MIDDLE EAST, AFRICA In ASIA BELGIUM B - 1070 Bruxelles Tel. +32 2 340 02 30 info.be@socomec.com NETHERLANDS NL - 3991 CD Houten Tel. +31 30 760 0900 info.nl@socomec.com POLAND 01-625 Warszawa Tel. +48 91 442 64 11 info.scp.pl@socomec.com CHINA P.R.C 200052 Shanghai - China Tel. +86 21 52 98 95 55 info.cn@socomec.com FRANCE F - 94132 Fontenay-sous-Bois Cedex Tel. +33 1 45 14 63 30 info.scp.fr@socomec.com GERMANY D - 76275 Ettlingen Tel. +49 7243 65292 0 info.scp.de@socomec.com ITALY I - 20098 San Giuliano Milanese (MI) Tel. +39 02 98 49 821 info.scp.it@socomec.com head OFFICE SOCOMEC GROUP S.A. SOCOMEC capital 10 816 800 R.C.S. Strasbourg B 548 500 149 B.P. 60010-1, rue de Westhouse F-67235 Benfeld Cedex - FRANCE VALID FOR FRANCE www.socomec.com SPAIN E - 08329 Teià (Barcelona) Tel. +34 93 540 75 75 info.es@socomec.com UNITED KINGDOM Hitchin Hertfordshire SG4 0TY Tel. +44 1462 440 033 info.scp.uk@socomec.com InTERnATIOnAL SALES DEpARTMEnT SOCOMEC 1, rue de Westhouse - B.P. 60010 F - 67235 Benfeld Cedex - FRANCE Tel. +33 (0)3 88 57 41 41 Fax +33 (0)3 88 74 08 00 info.scp.isd@socomec.com ROMANIA 023383 Bucharest Tel. +40 21 319 36 88 info.ro@socomec.com RUSSIA 125167 - Moscow Tel. +7 495 775 19 85 info.ru@socomec.com SLOVENIA SI - 1000 Ljubljana Tel. +386 1 5807 860 info.si@socomec.com TURKEY 34775 Istanbul Tel. +90 216 540 71 20-21-22 info.tr@socomec.com UNITED ARAB EMIRATES Dubai, U.A.E. Tel. +971 4 29 98 441 info.ae@socomec.com YOUR DISTRIBUTOR INDIA 122001 Gurgaon, Haryana - India Tel. +91 124 4027210 info.scp.in@socomec.com SINGAPORE Singapore 408723 Tel. +65 6506 7600 info.sg@socomec.com Non contractual document. 2013, Socomec SA. All rights reserved. - To help protect the environment, this document has been printed on PEFC paper (Programme for the Endorsement of Forest Certification) dcg_135 01 3us - 10/13