Selection of Electrical PPE Tables

Similar documents
Appendix A: Energized Work Permit

Electrical Hazards: Overhead and underground power lines. tools. Ungrounded electrical systems and tools. in wet/damp environments

Electrical Safety Program

IWU PHYSICAL PLANT SAFETY PROGRAM. Revision: 1 ELECTRICAL SAFETY Section: 4

Environmental, Health and Safety. Electrical Safety in the Workplace Program

NECA Personal Protective Equipment (PPE) Selector

CALIFORNIA STATE UNIVERSITY, LOS ANGELES ELECTRICAL SAFETY PROGRAM

Arc Flash 101. presented by Arc Flash Blaster LLC

The Pennsylvania State University Energized Electrical Safety Program

ARC FLASH INTRODUCTION. Injuries

Electrical & Arc Flash Safety Program 2007

Leader s Guide ERI Safety Videos

Campus Safety Procedure Electrical Safety

Electrical Safety Program

Why do I need to do an Arc-Flash Analysis?

Leader s Guide ERI Safety Videos

Electrical Safety Program

arc flash hazard analysis

ARC FLASH HAZARD ANALYSIS

The following general approach will be used when conducting energized electrical work.

KMU SUBSTATION WORKSHOP

2012 NFPA 70E: Electrical Safety In The Workplace

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE

Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized

D Square Construction LLC

Removing Yourself from Hazards During Equipment Operation

Duke University - Facilities Management Department Environmental Safety and Health Program ELECTRICAL SAFETY PROGRAM

USA Mobile, AL Electrical Safe Working Practices

Progressive Safety Services LLC - All Rights Reserved

WHAT IS THE N.F.P.A. 70E

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

ELECTRICAL SAFE WORK PRACTICES

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment

Portland Community College Facilities Management Services ENERGIZED ELECTRICAL WORK PERMIT AND WORK PLAN

ELECTRICAL SAFETY PROCEDURE

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

By: Bruce Bowman, P.E.

Risk Assessment Procedure

Chapter 14 (Rev )

POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH

Management Plan for Electrical Safety ISD #535

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager

Innovative Techniques for Mitigating Arc Flash Exposure

MANAGING ARC FLASH: A Risk Management Approach. Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane

Definitions found in several locations:

Electrical Safety Program

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program.

Electrical Safety Program

Chapter 7 - Electrical Safety

Individual employees are responsible for their own and their co-workers' safety. This means:

ELECTRICAL FLASHOVER HAZARDS AND SAFETY MEASURES REFERENCE TO DESIGN AND MAINTENANCE. Intrduction: B.MAHARANA, AGM(EM)/HOD NTPC,RAMAGUNDAM

Electrical Safety Program

Pulp & Paper Electrical Safety

Public Comment No. 151-NFPA 70E-2016 [ Global Input ]

MANAGING ARC FLASH RISKS: A Strategic Approach. Steve Williams Rockwell Automation TechED March 2016, Auckland

COMPANY SAFETY PROGRAM

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

Table of Contents. Note. Contents 1 through 13 are for non-authorized employees. Contents 14 through 16 are for authorized employees.

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard

Original Date of Issue: 04/09

CSA Z462 2 nd TO 3 rd EDITION DIFFERENCES CHANGES & UPDATES

Electrical. OSHA Office of Training and Education 1

100 Questions on Electrical Safety Study Guide

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING. Presented By Rick Edel

NFPA 70E, Proposed Changes. Electrical Safety in the Workplace NFPA Conference & Expo

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

NFPA 70E What Changed? Keeping People Safe from Electrical Hazards for over 50 Years

Electrical Hazard Assessments: OSHA & The NFPA 70E?

2018 NFPA 70E Significant Changes 7/27/2017. EFCOG Electrical Safety Task Group Workshop, July 2017

DuPont Arc Guide An Integrated Methodology to Mitigating Electric Arc Hazards

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

NESC WORKSHOP Revisions to Part 4 (Work Rules) Sam Stonerock. October 18, 2016

Electrical Safety Program

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Why an Effective Safety Program is Essential

Electrical Safety Program

Electrical Safety Work Practices

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

Arc flash versus arc resistant; different concerns

This presentation provides an overview of modern methods for minimizing the arc-flash hazard.

2100 ELECTRICAL SAFETY PROGRAM

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

In the electrical industry the phrase arc flash is generating a lot of

Dealing with Electrical Hazards in the Workplace


Electrical Safety Program

Electrical Safety Program February 2, 2016

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

ELECTRICAL SAFETY PROGRAM

Electrical Safety Guide

(1) Minimum Required. At least one entrance of sufficient area shall be provided to

Session Seven: Arc Flash Hazard (AFH) Rio Tinto Bell Bay Site

Blue Demon TIG Torch OWNER S MANUAL

Transcription:

Selection of Electrical PPE Tables Instructions Table 1 - Starting with Table 1, select the task you plan to do (right-hand column) and the condition of the equipment you will be working on, (center column). The equipment condition can be in any of three states of condition. The first condition that is described is as follows. All of the following must be true about the equipment state in question for this to apply to it: The equipment is properly installed The equipment is properly maintained All equipment doors are closed and secured All equipment covers are in place and secured There is no evidence of impending failure The second condition state that is described is as follows and if only one of these conditions is true, it indicates the overall default condition of the equipment. The equipment is not properly installed The equipment is not properly maintained Equipment doors are open or not secured Equipment covers are off or not secured There is evidence of impending failure The third state of equipment condition is any. This means that the condition of the equipment has no bearing on whether PPE is required. In this situation the task is the sole factor in determining if you require PPE. Once you determine the task and condition of the equipment you are working on, the right hand column of Table 1 indicates whether or not you need arc-rated PPE or not. If you need PPE, move to Table 2. On Table 2, determine the equipment type you ll be working with and arc flash category that you would be exposed to, e.g., category 1, 2, 3 or 4. NOTE: Table 2 has separate pages for AC systems and DC systems, so ensure you are on the correct page according to your system. When you find the equipment type and its correct voltage range you will be exposed to (left side column), the center column will provide the associated arch flash category. Then, look to the right-hand column to establish the distance from the source where you must be wearing the arc-rated clothing and gear. Table 3 - Once you have the arc flash category and distance from the source that the PPE is needed, go to Table 3 to determine what you are required to wear for the arc flash category you are working with. The abbreviations in the text can be found described in the notes below.

Selection of Personal Protective Equipment for Arc Flash Table 1 Determine Task + Equipment Condition

Table 1 - Arc Flash Hazard Identification for Alternating Current (ac) and Direct Current dc) Systems Task Equipment Condition* Arc Flash PPE Required Reading a panel meter while operating a meter switch rmal operation of a circuit breaker (CB), switch, contactor, or starter For ac systems: Work on energized electrical conductors and circuit parts, including voltage testing For dc systems: Work on energized electrical conductors and circuit parts of series-connected battery cells, including voltage testing Voltage testing on individual battery cells or individual multi-cell units All of the following: The equipment is properly installed The equipment is properly maintained All equipment doors are closed and secured All equipment covers are in place and secured There is no evidence of impending failure One or more of the following: The equipment is not properly installed The equipment is not properly maintained Equipment doors are open or not secured Equipment covers are off or not secured There is evidence of impending failure All of the following: The equipment is properly installed The equipment is properly maintained Covers for all other equipment are in place and secured There is no evidence of impending failure One or more of the following: The equipment is not properly installed The equipment is not properly maintained Equipment doors are open or not secured Equipment covers are off or not secured There is evidence of impending failure Removal or installation of CBs or switches Removal or installation of covers for equipment such as wireways, junction boxes, and cable trays that does not expose bare energized electrical conductors and circuit parts Removal of bolted covers (to expose bare energized electrical conductors and circuit parts). For dc systems, this includes bolted covers, such as battery terminal covers. All of the following: The equipment is properly installed The equipment is properly maintained There is no evidence of impending failure of the following: The equipment is not properly installed The equipment is not properly maintained There is evidence of impending failure (continues)

Table 1 Continued Task Removal of battery intercell connector covers Opening hinged door(s) or cover(s) (to expose bare energized electrical conductors and circuit parts) Perform infrared thermography and other noncontact inspections outside the restricted approach boundary. This activity does not include opening of doors or covers. Application of temporary protective grounding equipment after voltage test Work on control circuits with exposed energized electrical conductors and circuit parts, 120 volts or below without any other exposed energized equipment over 120 V including opening of hinged covers to gain access Work on control circuits with exposed energized electrical conductors and circuit parts, greater than 120 V Insertion or removal of individual starter buckets from motor control center (MCC) Insertion or removal (racking) of CBs or starters from cubicles, doors open or closed Equipment Condition* All of the following: The equipment is properly installed. The equipment is properly maintained Covers for all other equipment are in place and secured There is no evidence of impending failure One or more of the following: The equipment is not properly installed The equipment is not properly maintained Equipment doors are open or not secured Equipment covers are off or not secured There is evidence of impending failure Arc Flash PPE Required Insertion or removal of plug-in devices into or from busways Insulated cable examination with no manipulation of cable Insulated cable examination with manipulation of cable Work on exposed energized electrical conductors and circuit parts of equipment directly supplied by a panelboard or motor control center Insertion and removal of revenue meters (kw-hour, at primary voltage and current) For dc systems, insertion or removal of individual cells or multi-cell units of a battery system in an enclosure For dc systems, insertion or removal of individual cells or multi-cell units of a battery system in an open rack

Table 1 Continued Task For dc systems, maintenance on a single cell of a battery system or multi-cell units in an open rack For dc systems, work on exposed energized electrical conductors and circuit parts of utilization equipment directly supplied by a dc source Arc-resistant switchgear Type 1 or 2 (for clearing times of <0.5 sec with a prospective fault current not to exceed the arc-resistant rating of the equipment) and metal enclosed interrupter switchgear, fused or unfused of arc resistant type construction, tested in accordance with IEEE C37.20.7: Insertion or removal (racking) of CBs from cubicles Insertion or removal (racking) of ground and test device Insertion or removal (racking) of voltage transformers on or off the bus Equipment Condition* All of the following: The equipment is properly installed The equipment is properly maintained All equipment doors are closed and secured All equipment covers are in place and secured There is no evidence of impending failure Arc Flash PPE Required Opening voltage transformer or control power transformer compartments Outdoor disconnect switch operation (hookstick operated) at 1 kv through 15 kv Outdoor disconnect switch operation (gang-operated, from grade) at 1 kv through 15 kv One or more of the following: The equipment is not properly installed The equipment is not properly maintained Equipment doors are open or not secured Equipment covers are off or not secured There is evidence of impending failure te: Hazard identification is one component of risk assessment. Risk assessment involves a determination of the likelihood of occurrence of an incident, resulting from a hazard that could cause injury or damage to health. The assessment of the likelihood of occurrence contained in this table does not cover every possible condition or situation. Where this table indicates that arc flash PPE is not required, an arc flash is not likely to occur. *The phrase properly installed, as used in this table, means that the equipment is installed in accordance with applicable industry codes and standards and the manufacturer s recommendations. The phrase properly maintained, as used in this table, means that the equipment has been maintained in accordance with the manufacturer s recommendations and applicable industry codes and standards. The phrase evidence of impending failure, as used in this table, means that there is evidence of arcing, overheating, loose or bound equipment parts, visible damage, deterioration, or other damage.

Table 2 Determine Equipment Type + Arc Flash Category

Table 2 Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems Equipment Arc Flash PPE Category Arc-Flash Boundary Panelboards or other equipment rated 240 V and below Parameters: Maximum of 25 ka short-circuit current available; maximum of 0.03 sec (2 cycles) fault clearing time; working distance 455 mm (18 in.) Panelboards or other equipment rated >240 V and up to 600 V Parameters: Maximum of 25 ka short-circuit current available; maximum of 0.03 sec (2 cycles) fault clearing time; working distance 455 mm (18 in.) 600-V class motor control centers (MCCs) Parameters: Maximum of 65 ka short-circuit current available; maximum of 0.03 sec (2 cycles) fault clearing time; working distance 455 mm (18 in.) 600-V class motor control centers (MCCs) Parameters: Maximum of 42 ka short-circuit current available; maximum of 0.33 sec (20 cycles) fault clearing time; working distance 455 mm (18 in.) 600-V class switchgear (with power circuit breakers or fused switches) and 600 V class switchboards Parameters: Maximum of 35 ka short-circuit current available; maximum of up to 0.5 sec (30 cycles) fault clearing time; working distance 455 mm (18 in.) Other 600-V class (277 V through 600 V, nominal) equipment Parameters: Maximum of 65 ka short circuit current available; maximum of 0.03 sec (2 cycles) fault clearing time; working distance 455 mm (18 in.) NEMA E2 (fused contactor) motor starters, 2.3 kv through 7.2 kv Parameters: Maximum of 35 ka short-circuit current available; maximum of up to 0.24 sec (15 cycles) fault clearing time; working distance 910 mm (36 in.) Metal-clad switchgear, 1 kv through 15 kv Parameters: Maximum of 35 ka short-circuit current available; maximum of up to 0.24 sec (15 cycles) fault clearing time; working distance 910 mm (36 in.) 485 mm 1 (19 in.) 900 mm 2 (3 ft) 1.5 m 2 (5 ft) 4.3 m 4 (14 ft) 4 6 m (20 ft) 1.5 m 2 (5 ft) 4 12 m (40 ft) 12 m 4 (40 ft) Arc-resistant switchgear Type 1 or 2 [for clearing times of < 0.5 sec (30 cycles) with a perspective fault current not to exceed the arc-resistant rating of the equipment], and metal-enclosed interrupter switchgear, fused or unfused of arc-resistant-type construction, tested in accordance with IEEE C37.20.7, 1 kv through 15 kv N/A (doors closed) N/A (doors closed) Parameters: Maximum of 35 ka short-circuit current available; maximum of up to 0.24 sec (15 cycles) fault clearing time; working distance 910 mm (36 in.) Other equipment 1 kv through 15 kv Parameters: Maximum of 35 ka short-circuit current available; maximum of up to 0.24 sec (15 cycles) fault clearing time; working distance 910 mm (36 in.) 4 (doors open) 12 m (40 ft) 4 12 m (40 ft) te: For equipment rated 600 volts and below, and protected by upstream current-limiting fuses or current-limiting circuit breakers sized at 200 amperes or less, the arc flash PPE category can be reduced by one number but not below arc flash PPE category 1.

Table 2 Arc-Flash Hazard PPE Categories for Direct Current (dc) Systems Storage batteries, dc switchboards, and other dc supply sources Equipment Arc Flash PPE Category Arc-Flash Boundary 100 V > Voltage < 250 V Parameters: Voltage: 250 V Maximum arc duration and working distance: 2 sec @ 455 mm (18 in.) Short-circuit current < 4 ka 1 4 ka short-circuit current < 7 ka 2 7 ka short-circuit current < 15 ka 3 900 mm (3 ft) 1.2 m (4 ft) 1.8 m (6 ft) Storage batteries, dc switchboards, and other dc supply sources 250 V Voltage 600 V Parameters: Voltage: 600 V Maximum arc duration and working distance: 2 sec @ 455 mm (18 in.) Short-circuit current 1.5 ka 1 1.5 ka short-circuit current < 3 ka 2 3 ka short-circuit current < 7 ka 3 7 ka short-circuit current < 10 ka 4 900 mm (3 ft) 1.2 m (4 ft) 1.8 m (6 ft.) 2.5 m (8 ft) te: Apparel that can be expected to be exposed to electrolyte must meet both of the following conditions: (1) Be evaluated for electrolyte protection in accordance with ASTM F1296, Standard Guide for Evaluating Chemical Protective Clothing (2) Be arc-rated in accordance with ASTM F1891, Standard Specification for Arc Rated and Flame Resistant Rainwear, or equivalent

Table 3 - PPE Selection by Arc Flash Category

Table 3 Personal Protective Equipment (PPE) PPE Category (1) Arc-Rated Clothing, Minimum Arc Rating of 4 cal/cm 2 (see te 1) Arc-rated long-sleeve shirt and pants or arc-rated coverall Arc-rated face shield (see te 2) or arc flash suit hood Arc-rated jacket, parka, rainwear, or hard hat liner (AN) Protective Equipment Hard hat Safety glasses or safety goggles (SR) Hearing protection (ear canal inserts) Heavy duty leather gloves (see te 3) Leather footwear (AN) (2) Arc-Rated Clothing, Minimum Arc Rating of 8 cal/cm 2 (see te 1) Arc-rated long-sleeve shirt and pants or arc-rated coverall Arc-rated flash suit hood or arc-rated face shield (see te 2) and arc-rated balaclava Arc-rated jacket, parka, rainwear, or hard hat liner (AN) Protective Equipment Hard hat Safety glasses or safety goggles (SR) Hearing protection (ear canal inserts) Heavy duty leather gloves (see te 3) Leather footwear (3) Arc-Rated Clothing Selected so That the System Arc Rating Meets the Required Minimum Arc Rating of 25 cal/cm 2 (see te 1) Arc-rated long-sleeve shirt (AR) Arc-rated pants (AR) Arc- rated coverall (AR) Arc-rated arc flash suit jacket (AR) Arc-rated arc flash suit pants (AR) Arc-rated arc flash suit hood Arc-rated gloves (see te 1) Arc-rated jacket, parka, rainwear, or hard hat liner (AN) Protective Equipment Hard hat Safety glasses or safety goggles (SR) Hearing protection (ear canal inserts) Leather footwear ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4 Arc-Rated Clothing Selected so That the System Arc Rating Meets the Required Minimum Arc Rating of 40 cal/cm 2 (see te 1) Arc-rated long-sleeve shirt (AR) Arc-rated pants (AR) Arc-rated coverall (AR) Arc-rated arc flash suit jacket (AR) Arc-rated arc flash suit pants (AR) Arc-rated arc flash suit hood ` Arc-rated gloves (see te 1) Arc-rated jacket, parka, rainwear, or hard hat liner (AN) Protective Equipment Hard hat Safety glasses or safety goggles (SR) Hearing protection (ear canal inserts) Leather footwear ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- AN: as needed (optional). AR: as required. SR: selection required. tes: (1) Arc rating is defined in Article 100. (2) Face shields are to have wrap-around guarding to protect not only the face but also the forehead, ears, and neck, or, alternatively, an arc-rated arc flash suit hood is required to be worn. (3) If rubber insulating gloves with leather protectors are used, additional leather or arc-rated gloves are not required. The combination of rubber insulating gloves with leather protectors satisfies the arc flash protection requirement.