TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

Similar documents
TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

TH-1800-T TRX-700-CNG Converter

Integral type Differential pressure flowmeter VNT Series

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

Design Features. General Description

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Mass Flow Controllers

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Mass Flowmeters. Mass Flowmeters for Gases

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

2/2-Way Solenoid Control Valve

Mass Flow Meter (MFM) for Gases

Flow Meters and Flow Controllers

UNDERSTANDING, ACCELERATED

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

RCD - Ultra-Rugged Differential Pressure Flowmeter

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Features. Description

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Ultrasonic level transmitter and indicator

2/2-Way Proportional Valve (motor-driven)

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Flow metering in gases Introduction to COMBIMASS family

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Mass Flow Meter (MFM) for gases

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SITRANS P measuring instruments for pressure

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Gas Mass Flow Meter SUS/SUS316

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Mass Flow Controller (MFC) for Gases

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Level transmitter LT 100

Electro-Pneumatic Converter YT-940 SERIES

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

C-Flow Coriolis Mass Flow Meters

Programmable pressure and temperature transmitters PTM/RS485

780S Ultra High Purity Series

2/2-Way Solenoid Control Valve

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Flow Controller (MFC) for Gases

Series IRV1000/2000/3000

2/2-way proportional valve

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Pro-V Multivariable Flowmeter

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

2/2-way proportional valve

Mass Flow Controller (MFC) for Gases

Model 4000 Pressure Controller

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

analytical bulk flow distance FLOW level pressure temperature industrial communication

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

How to specify a product. Process Sensors and Mechanical Instruments

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Code Basic module and level control complete with optionals code

Liquid level instruments BM 24 /BM 51

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Differential Pressure Transmiter

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

TKF Mass Flow Controller. FCS Thermal Series. Digital interface 준비장비 (RS-485)

Best Practice Guide, Servomex 2700

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Orifice Plate Flow Meter

INSTALLATION & MAINTENANCE INSTRUCTIONS

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Model 601CV. Mass Flow Controller. Product Features:

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Bypass Mass Flow Controller (MFC) for gases

PS100 Series. Pressure-Based PI Mass Flow Controller. Catalog

MDM490 Piezoresistive Differential Pressure Transmitter

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

SonoMeter 30 Energy Meters

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Transcription:

FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC automatically controls the mass flow rate of various kinds of gases with high accuracy. General purpose of TC-1 upto.99mpa and high pressure version of TC 2 upto 1MPa are available. FEATURES WIND FLOW RANGE Minimum to 5mL/min(nor), Maximum to 5L/min(nor) ( to 5mL/min(nor) to to 1L/min(nor) for High pressure version) HIGH ACCURACY ±1% F.S. control accuracy. QUICK RESPONSE 3sec. response for 98% FREE FROM PRESSURE AND TEMPERATURE VARIATION Negligible ZERO and SPAN drift for pressure and temperature. HIGH RELIABILITY Special stainless steel with high anti-corrosive capability is used for solenoid valve actuator. Durable for long time operation. HIGH FUNCTION Theoretically, Mass flow measurement. Then, the bridge circuit outputs electric signal. Theoretically, the heat transfer is proportional to the moving mass of the gas to be measured and its specific heat. The specific heat of the gas is not affected by its pressure and within reasonable range of temperature, it can be observed to be as stable. Thus, by measuring the heat transfer through bridge output, the mass flow rate of the gas can be measured. The output signal from the bridge circuit is amplified to DC to 5V and sent to indicator and as comparison circuit. At the comparison circuit, the output is compared to the external setting signal. The control valve is actuated to open or to close to make the output and setting signal equal. The control valve has an electromagnetic type actuator for Normal close action. OPERATION PRINCIPLE The gas to be measured is directed to by-pass sensing path by flow restriction. At the by-pass sensing path, two resistance coils are wound which consist a bridge circuit with resistance circuit in electric compartment. In case of no flow passing through the by-pass sensing path, the bridge circuit is in balanced condition. When the gas moves, the heat at the up stream coils is transferred to down stream coil and thus upsetting the original heat balance. TCP POWER SUPPLY UNIT DC±15V AMPLTFIER CIRCUIT TCDU INDICATOR FLOW SIGNAL TCDU SETTING DEVICE COMPARISON CIRCUIT CONTROL VALVE FLOW SETTING SIGNAL BY-PASS SENSOR BRIDGE CIRCUIT SPRING GAS INLET RESTRICTION GAS OUTLET ORIFICE OCT. 27K

TC-1 GENERAL PURPOSE THERMAL MASS FLOW CONTROLLER MODEL CODE STANDARD SPECIFICATIONS TC-1 - - - GAS TYPE TC-11 TC-12 FLOW RANGE 1 2 3 35 4 53 55 5 1 2 3 1L/min(nor) 2L/min(nor) 8L/min(nor) 1L/min(nor) 3L/min(nor) 3L/min(nor) 5L/min(nor) 5mL/min(nor) 1mL/min(nor) 2mL/min(nor) 3mL/min(nor) FLOW RENGE (FULL SCALE) FLOW CONTROL RANGE RESPONSE TIME (98% RESPONSE) FLOW RATE OUTPUT SIGNAL SETTING SIGNAL ACCURACY CONTROL P(MPa). GAS PRESS(MPa) GAS. TEMP 5mL/min(nor) to 1L/min(nor) 1 to 2L/min(nor).66 to.3.66 to.3 5 11 5mL/min(nor) 1mL/min(nor) TEMP.DRIFT 21 31 51 12 22 32 52 2mL/min(nor) 3mL/min(nor) 5mL/min(nor) 1L/min(nor) 2L/min(nor) 3L/min(nor) 5L/min(nor) TC-11 PRESS.DRIFT GAS CONTACT MATERIAL CONNECTON WEIGHT(kg) DC+15V 25mA Max. DC 15V 2mA Max. Rc1/4, OD1/4SW, VCR, VCO 1.1 1.4 FULL SCALE 13 153 23 1L/min(nor) 15L/min(nor) 2L/min(nor) TC-12 DIMENSION 33 3L/min(nor) 53 73 5L/min(nor) 7L/min(nor) TC-13 TC-11 83 8L/min(nor) 14 1L/min(nor) TC-135 154 15L/min(nor) 24 254 2L/min(nor) 25L/min(nor) TC-14 34 3L/min(nor) 44 54 4L/min(nor) 5L/min(nor) TC-155 P Rc N NPT CONNECTION S SW R VCR O 4 VCO 1/4" TC-11, 12 TC-12 6 3/8" TC-13, 135 CONNECTION SIZE 8 1/2" TC-14 12 16 3/4" 1" TC-14, 15 2 TOKYO KEISO CO., LTD.

TC-13 TC-135 TC-14 TC-155 2 to 8L/min(nor) 8 to 1L/min(nor) 1 to 15L/min(nor) 15 to 2L/min(nor) 2 to 3L/min(nor) 4 to 5L/min(nor) 2 to 1% OF FULL SCALE WITHIN 3 sec. WITHIN 4 sec. DC to 5V DC to 5V ±1%F.S.(at 25 C).7 to.3.1 to.45.12 to.35.15 to.35.18 to.5 9.9(.99) 5 to 5 C SPAN.1%F.S./ C Max. ZERO.5%F.S./ C Max..25%F.S. (WITHIN OPERATING PRESSURE RANGE) DC+15V 25mA Max. DC 15V 32mA Max. DC+15V 25mA Max. DC 15V 2mA Max. SUS316, SHOMAC*2, PTFE, FKM or CR OD 3/8SW, VCR, VCO Rc3/4, 1, OD 1/2, 3/4 SW Rc 3/4, 1 2. 3.2 6. 6.2 *(1) Flow rate with Nitrogen. Refer to MODEL CODE for details *(2) Ferrite Stainless Steel material TC-13 TC-135 TC-14 TC-155 TOKYO KEISO CO., LTD. 3

TC-2 HIGH PRESSURE THERMAL MASS FLOW CONTROLLER MODEL CODE STANDARD SPECIFICATIONS TC-2 - - - GAS FLOW RANGE 1 2 3 FULL SCALE CONNECTION 5 11 21 31 51 12 22 32 52 13 153 23 33 53 73 83 14 CONNECTION SIZE P N S 4 6 1L/min(nor) 2L/min(nor) 1L/min(nor) 5mL/min(nor) 1mL/min(nor) 2mL/min(nor) 3mL/min(nor) 5mL/min(nor) 1L/min(nor) 2L/min(nor) 3L/min(nor) 5L/min(nor) 1L/min(nor) 15L/min(nor) 2L/min(nor) 3L/min(nor) 5L/min(nor) 7L/min(nor) 8L/min(nor) 1L/min(nor) Rc NPT SW 1/4" 3/8" TC-21 TC-22 TC-23 TC-21/TC-22 TC-23 FLOW RANGE*(1) (FULL SCALE) FLOW CONTROL RANGE RESPONSE TIME FLOW RATE OUTPUT SIGNAL SETTING INPUT SIGNAL ACCURACY. GAS PRESS (MPa) CONTROL P kg/cm 2 (MPa) GAS. TEMP TEMP. DRIFT PRESS DRIFT GAS CONTACT CONNECTION MODEL SPAN ZERO SIZE TYPE TC-21 5mL/min(nor) to 1L/min(nor) TC-22 1 to 2 L/min(nor) TC-23 2 to 1 L/min(nor) 2 to 1% OF FULL SCALE WITHIN 3 sec. (98% RESPONSE) DC to 5V DC to 5V ±1%F.S.(at 25 ) 1MPa 5 to 8% of Primary pressure*(3) 5 to 5 C.1%F.S./ Cmax.5%F.S./ Cmax.1%F.S./(.1MPa)max DC+15V 25mA DC 15V 32mA SUS316, SHOMAC *(2), PTFE, FKM or CR OD 1/4 OD 3/8 Swagelok Rc (=PT), NPT *(1) Flow rate with Nitrogen. In case of measurement of hydrogen (H2) Minimum flow range will be 25mL/min(nor). *(2) Ferrite Stainless Steel material 4 TOKYO KEISO CO., LTD.

DIMENSION TC-21 TC-22 TC-23 TOKYO KEISO CO., LTD. 5

SUPPORTING INSTRUMENTS EXCLUSIVE CABLES Connection cables are available as follow. Cable ends are properly terminated for immediate connection to devices. TYPE OF CABLE USAGE STANDARD LENGTH SC-T TC-1/TC-2 TCP 2m SC-DS SC-CM- TCP TCSU TCDU TC-1/TC-2 TM-14 2m 2m (Max.1m) TCP UNIT TCP supplies necessary power to TC Controller and TCDU indicator. Also, TCP scales the output from TC controller and feeds to TDCU to indicate flow rate in actual scale. TYPE TCP-1 TCP-3 TCP-5 FOR TC-1/2 FOR TDCU FLOW SETTING OUTPUT +15V 1mA 15V 35mA +5V 2mA +5V±.1% FOR 3 LOOPS FOR 5 LOOPS AC1V±1% 5/6Hz DIMENSION 6 1 12 14 1 144 226 1 144 TCP-1 *L=226, =18 for TCP-5 TCP-3 Fixture TCDU INDICATOR TCDU is a "Digital Panel Meter" with 3 1/2 digit indication. Flow rate of the gas is indicated actual industrial unit such as L/min(nor). MODEL INDICATION DIGIT HEIGHT TCDU-8 3 1 /2digit 8mm +5V 1mA Panel cut TCSU SETTING DEVICE TCSC is a potentio-meter with 2 digit setting counter. Flow rate can be set with 1/1 resolvability. MODEL SPECIFICATION RESISTANCE TCSU Potentio-Merer with 2 digit setting counter 1k / 1 rotation Panel cut 6 TOKYO KEISO CO., LTD.

1 5 9 SCALE ZERO REF EXT1 EXT2 DIRECT FULL ZERO SET 2 3 4 1 1 5 9 9 6 8 7 SCALE ZERO EXT1 REF EXT2 DIRECT FLOW SET FULL SET ZERO 2 3 4 1 1 5 9 9 6 8 7 TC THERMAL MASS FLOW CONTROLLER TM-14 CONVERTER UNIT TM-14 MINI CONVERTER UNIT is power supply and indication unit which is used in combination with Tokyo Keiso s TC-1, 2 series mass flow controllers. All necessary functions of power supply to the mass flow controllers and scaling indication of flow signal, and flow rate setting function with the change of external/manual setting are provided in DIN 72mm compact housing. Additionally, totalizing pulse output is provided as option for easy composition of the flow-rate regulating system of various gases. 72 25 5.5 147 12 Panel cut and installation interval More than 9 TM-1 CONVERTER 67 +.7-72 SCALE ZERO REF EXT1 EXT2 DIRECT FLOW SET FULL SET ZERO 2 3 4 1 9 TOKYO KEISO 6 8 7 More than 1 67 +.7 - SYSTEM CONFIGURATION By using separate units CABLE SC-DS UNIT AC 1V TCDU INDICATOR TCSU SETTING DEVICE TC-1 CON- TROLLER CABLE SC-T TCP-1 FOR 1 LOOP TCP-3 FOR 3 LOOPS TCP-5 FOR 5 LOOPS With TM-14 CONVERTOR UNIT PROPORTIONAL MIXING PROCESS A GAS FLOW SIGNAL Exclusive cable (SC-CM- ) POWER SUPPLY TM-1 CONVERTER TOKYO KEISO TM-14 Analog output (Totalizing pulse output) AC power supply TM-1 CONVERTER FLOW SET Analog output (Totalizing pulse output) AC power supply TF-5/TF-6 MASS FLOWMETER TOKYO KEISO TC-1, TC-2 TM-14 TC-1/2 CONTROLLER TOKYO KEISO CO., LTD. 7

ORDERING INFORMATION Specify the following for order/inquiry THERMAL MASS FLOW CONTROLLER TYPE TC- - - GAS TO BE MEASURED PRIMARY PRESS.. MPa Nor. MPa Min. MPa DIFFERENTIAL PRESS. TEMP. to C MPa FULL SCALE ml/min(nor) L/min(nor) CONNECTION SIZE CONNECTION TYPE 1/4" 3/8" 1/2" 3/4" 1" Swagelok Rc (=PT) NPT VCR VCO SUPPORTING INSTUMENTS UNIT TCP-1 TCP-3 TCP-5 Not required INDICATOR SETTING DEVICE CONVERTER TCDU-8 TCSU TM-14 - (Indication+Setting) Not required Not required Not required EXCLUSIVE CABLE SC-DS SC-T SC-CM- STD. 2m m (Max.2m) STD. 2m m (Max.1m) STD. 2m m (Max.1m) * Specification is subject to change without notice. Head Office : Shiba Toho Building, 1 7 24 Shibakoen, Minato-ku, Tokyo 15 8558 Tel : +81-3 3431 1625 (KEY) ; Fax : +81-3 3433 4922 e-mail : overseas.sales@tokyokeiso.co.jp ; URL : http://www.tokyokeiso.co.jp 8 TOKYO KEISO CO., LTD.