Akvasmart Sensors USER MANUAL. Oxygen - Temperature - Current tilt

Similar documents
PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Portable Massage Table User Manual

M S I C R A N E S C A L E

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

INSTALLATION PROCEDURES FOR COATED RAYATEN MOULDED PARTS ONTO D-SUBMINIATURE CONNECTORS

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

Simrad GD10P Extended On-site Maintenance

92831 TEL: (714) FAX:

Table of Contents Documentation for PIT TROLLEY A4

User s Manual. USB Golf Simulator. Contents

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Product Name: Concrete Anchor Strap

MODEL 100 NITROGEN INFLATION CART

Heavy Duty Dissolved Oxygen Meter

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

889P & 889P/B Backboard

T EK-SUB 4800C 19 mm Submersible Level Transmitter

GAS FUEL VALVE FORM AGV5 OM 8-03

Tripod Series OPERATOR S MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Najo Backboards. by Ferno. Users Manual. February 2006 GLO Pub. No Najo RediBoard. Najo Lite. Najo. Najo RediHold. RediWide.

INSTRUCTION MANUAL Pressure Relief Device LPT

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Stainless Steel Rescue Litters

Service Calibration are you doing it properly?

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

NEULOG OXYGEN LOGGER SENSOR GUIDE

! Warning, refer to accompanying documents.

GasSense NDIR User Manual

Geotech 1.66 Reclaimer

AQQWALKING TREAD MILL

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Q2: Which instruments are necessary for monitoring the groundwater level?

Pressure Injection Cell Operator s Manual

Page 1. Single Scull Car Rack Assembly and User s Manual " "

UsER manual for Watersens ph -REDOX

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141

LDO II AQ 2/2014, Edition 1.5

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

INSTALLATION & MAINTENANCE INSTRUCTIONS

Instructions for Dual Retractable Web lanyards Type 1. Instructions for E6 Energy Absorbing Y, Bypass Lanyards. For Worker Mass Range of 90 to 175 kg

RAM 4021 Operation Manual

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Operating Manual VSA100A. tina29e1 ( )

Oxygen Sensor with Electrode

Model 6812C Dual Lane Scoreboard Owner s Manual

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Fingertip Pulse Oximeter

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

Versie Date: USAGE AND SAFETY MANUAL SPREADERBEAMS

92831 TEL: (714) FAX:

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Instruction Manual Contact Pressure Vacuum Gauge

OPERATION AND INSTRUCTION MANUAL

DISCLAIMER & COPYRIGHT CONTENTS

BoatWasher Swede, , MS Float

INSTRUCTIONS FOR USE

Expert Hydrostatic Level Transmitters

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

6 digital caliper with case

Product Name: Edge Series Web SRL

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

OBELISK & TRIBUS Locking Pin 50mm

HYDRAULIC TOOLS: CABLE CUTTER CC0260

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

CONTENTS AIRBERTH OWNER S MANUAL I 3

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

INSTRUCTIONS FOR USE

SIDE 16 Sidemount System User Manual

Optical Dissolved Oxygen Meter

LM6 LEATHER MOISTURE METER

Product Name: Angel Anchor

Instructions for Use Wire Rope Hoist SAT 08 / SAT 16 / SAT 32

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

CLASS CYCLE P8000 OWNER'S MANUAL JOHNSON HEALTH TECH. CO., LTD.

Transmitter CS 21 Operation Manual

Transcription:

USER MANUAL Akvasmart Sensors Oxygen - Temperature - Current tilt B 07.04.14 Corrections temperature sensor EBL IL A 27.03.14 Second edition, with RDO Sensor EBL IL / PÅN Rev Date Issued Issued by Approved Document no.: DC10000536 Project no.: 88073-01 Page 1 of 29

The information in this document is subject to change without notice and should not be construed as a commitment by AKVA group ASA. AKVA group ASA assumes no responsibility for any errors that may appear in this document. In no event shall AKVA group ASA be liable for incidental or consequential damages arising from use of this document or of the software and hardware described in this document. We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Additional copies of this document may be obtained from AKVA group ASA at its current charge. 2014 AKVA group ASA (NO) AKVA group ASA Page 2 of 29

Table of contents 1 Safety...4 1.1 Safety symbols used in the manual...4 1.2 Receiving new equipment...5 1.3 Plug caps...5 1.4 Disinfecting the equipment...5 1.5 Cable...6 1.6 Bad weather...6 2 Introduction...7 2.1 Contact information...8 3 Sensors...9 3.1 Current sensor... 10 3.2 Oxygen sensors... 12 3.3 Temperature sensor... 14 4 Flow diagram for sensors...16 5 Installation and suspension...17 5.1 Current sensor... 17 5.2 Oxygen sensor... 17 5.3 All sensors... 17 6 Power supply...18 7 Handling the cable...19 8 Maintenance...20 8.1 Daily inspection... 20 8.2 Weekly inspection and maintenance... 20 8.3 Monthly inspection and maintenance... 21 8.4 Recommended maintenance plan... 21 8.5 Maintenance plans... 22 Appendix A - Index...26 Appendix B - Deviation form...27 Appendix C - Notes...28 Page 3 of 29

1 Safety Safety for the users of our equipment is top focus when AKVA group ASA develop new products and product manuals. We therefor strongly recommend that everyone that use the equipment, all that perform any type of repairs, service or other maintenance to the product, and all that work in areas where the product is installed read this entire manual and at least this safety chapter. This recommendation is based on both personnel safety as well as a desire to keep the products in order and avoid damages risked if the safety instructions are not followed. 1.1 Safety symbols used in the manual The following symbols are used in this manual: Information Important information Show caution, danger of damaging equipment and mild injuries to personnel 1.1.1 Other symbols used in the manua See chapter or page for more information or further instructions. Page 4 of 29

1.2 Receiving new equipment Always check that the delivery is complete according to the service note. If the order is not complete or if any other errors are discovered, contact AKVA group immediately. AKVA group ASA provides a 1 year warranty covering manufacturer s defects. The warranty is effective upon date of shipment to original recipient. The following are reasons for a void of warranty: - Poor treatment of the system due to negligence of preventive recommendations or from improper usage of power sources - If the sensor units are opened without express written consent of an AKVA group employee 1.3 Plug caps Always keep plug-caps safe after installing equipment. We recommend that all plug caps are kept in one, safe place inside the barge so that the caps are easy to locate when taking the equipment out of use for maintenance, repairs and similar tasks. To avoid moisture and salt water sprout in the connections, it is important to replace all plug caps to the EAP or the CSU as well as in cable ends immediately after removing the equipment. 1.4 Disinfecting the equipment If equipment, cables, suspensions and other things that belong to this equipment is going to be moved from one site to another, it is decreeded by law to disinfect everything to prohibit contamination. We recommend rinsing everything with fresh water after disinfection, because the disinfecting medium may be corrosive to the equipment. Page 5 of 29

1.5 Cable Make sure that the sensor cables are never twirled! Coil them according to instructions in chapter 7. Make sure that the cable is in order, without any tears or damages, when it is connected to power. The cable must not be used if it has any bends, tears or breaks. To make sure that there is no tension to the cable when the sensor is in the water, and to avoid lifting the sensor by its cable, always use lifting ropes, one for each sensor. Instructions for these ropes are found in chapter 5.2. 1.6 Bad weather Always make sure that all of the ropes and all of the equipment are ok after bad weather and storms. These may cause the ropes and cables to twirl, the equipment may to loosen, it may even cause damages to the equipment. Therefore, it is important to check that everything is in order after stormy weather. If anything is out of order or damaged, contact AKVA immediately. Page 6 of 29

2 Introduction This user manual is part of the equipment delivered with AKVAsmart sensors. Preserve the manual for as long as the equipment is being used, and make sure that all changes done to the equipment are being noted in this manual. Thank you for choosing AKVA group ASA as supplier for your sensor. Do not hesitate contacting us if you need more information regarding installation, use or maintenance for your product. With four main brands, AKVA group ASA is a world leading supplier of technical aquaculture equipment. Since 1980 we have developed and produced fish farming equipment, both for cages at sea and for land based hatcheries. AKVA represents an industrial standard, which is presumed to be the key to the future. Research, project management, fast deliveries and customer follow-up have been our focus to ensure that we contribute to a positive development within the aquaculture industry. Our goal is to deliver the best possible and most cost efficient equipment in order to keep preserving sustainable farming. We have a wide variety of products, for example: plastic and steel cages, high pressure washers, net washers, boats, feed barges, feeding systems, cameras, sensor systems, under water lighting, software for fish farming and recycling systems. We practice continuous product development to improve the equipment s safety, functions, manner of operation and working reliability. This User Manual enables the operator to run and maintain the Akvasmart Sensors in a safe and economically way. All of our equipment is pre-installed, tested and delivered from our own production department or from authorized collaborating companies. User manual AOS AKVA Sensor Buoy Current Document no. DC10000684 Page 7 of 29

Our production staff consists of people with great expertise and enthusiasm to produce the best possible products for you. Having our own production site gives you excellent service in case something should go wrong, or if you are in need of any assistance. We hold most of the parts for your equipment in stock, and our service staff is available on the telephone or on location in order to assist you if necessary. This entire manual and especially the safety chapter must be read and understood before commencing any work on the equipment. Prior to operating, repairing, performing maintenance or any other operations related to the sensor, we recommend that the personnel attend proper training by AKVA group ASA. This manual must be read and maintenance must be performed as described to ensure reliable operation. The Operating manual will give answers to most of the day to day question and operating procedures. 2.1 Contact information AKVA group ASA - Bryne (Head Office) Nordlysveien 4 PO. Box 271 4340 Bryne Norway tel. +47-51 77 85 00 fax. +47-51 77 85 01 Support Hardware and AKVAconnect tel. + 47-51 77 85 03 supportakvasmart@akvagroup.com Support Fishtalk tel. +47-73 84 28 20 supportfishtalk@akvagroup.com User manual AOS AKVA Sensor Buoy Current Document no. DC10000684 Page 8 of 29

3 Sensors Controlling environmental data as temperature, oxygen level and current speed are important inputs when feeding fish. In the Akvasmart CCS Feed System, all these factors can be set to automatically control or adjust the feeding amount and its speed. All environmental data will be logged and can be used in further analyses either in AkvaControl or in Fishtalk. Accurate real time measurements are shown and logged in the control program and AkvaControl will calculate expected daily feed amount based on feeding tables and invited sensor data. The system can be wireless and signals are transferred between the cage edge (via CSU or EAP) and the base unit. Therefore, cables are only necessary from the cage edge and down to the sensors. Each cage may be adjusted individually, and the entire system is connected to the Akvasmart CCS Feeding System. The entire system is an aid for the feeding operators, so that they, with correct use of this system and AKVA s specifications, can optimize the feeding and thereby exploit full potential from the feed. This gives best possible growth and the lowest feed factor. Correct feeding is turnkey for achieving good fish breeding results Excellent environmental conditions are a smart investment, that will improve the bottom line Page 9 of 29

3.1 Current sensor Two types of the current sensors: - one measuring currents from 0-50cm/sec - one larger sensor measuring currents from 0-100cm/sec Current sensor, type 0-50 cm/sec 0-100 cm/sec Accuracy +/- 1 cm/sec +/- 2 cm/sec Measurement range 0-50 cm/sec (0-1 knots) 0-100 cm/sec (0- knots) Measuring principle Electronic tilt sensor Electronic tilt sensor Materials Acrylic/POM/Aluminum Acrylic/POM/Aluminum Power consumption 75mA 75mA Cable 30m polyurethane cable 30m polyurethane cable Plug Amphenol (water proof, potted plug) Amphenol (water proof, potted plug) Max. depth range 30m* 30m* Size - L x W x H 165x165x200mm 165x165x200mm Weight 5kg - 12kg** 5,3kg - 12,3kg** *Limited by cable length ** Including stainless steel stabiliser weight and cable Page 10 of 29

The Akvasmart Current sensor is one of several tools developed for the fish farming industry to optimize feeding and thereby cost benefits. The current sensor is directly connected to the Akvasmart CCS Feeding System, and signals participate in regulating the feeding rate and amount. The sensor also contribute in preventing feed from being carried out from the cage before the fish gets the chance to eat it. Sensors are placed strategically, and maximum current speed for feed termination as well as which cages are controlled by the specific sensor, is programmed. When the current exceeds this given limit, the feeding stops automatically in the specified cages, and starts again when current is back below the limit. When the sensor is affected by currents, the angle changes like a pendulum. The angle is electronically measured and is converted to cm/sec (feeding limit is given in cm/sec). The current sensor has no moveable parts. This gives it longevity and a minimum of maintenance. A centre weight must be attached to the current sensor. See instructions in chapter 5.1 for more information. Page 11 of 29

3.2 Oxygen sensors RDO Oxygen Sensor Accuracy: Operating temp.range Measurement range Measuring principle Materials Power consumption Cable Plug Max depth rating Size - L x Ø Weight +/- 0.1mg/L 0-8mg/L +/- 0.2mg/L 8-20mg/L +/- 10% 20-50mg/L 0-50 C (32-122 F) 0-50 mg/l Optical luminescent Polyethylene 50mA at 12 VDC 10m or 50m Amphenol (water proof) 210m (689 ) limited by cable 203mm x 47mm 0,9kg with 10m cable Page 12 of 29

Oxygen sensors are one of several tools developed for the fish farming industry to optimize feeding and thereby the fish farms cost benefits. Oxygen is an important factor for growth and fish welfare. With this sensor connected to the feeding system, feed amount may be stopped when the waters oxygen level is too low. The RDO oxygen sensor is a robust and reliable membrane free sensor whose measurements are based on optical readings. This reduces the need for calibrations, gives high accuracy degree and can be used for long periods without loss of measurement accuracy. Simple, regularly cleaning is all the only maintenance needed for this device. AKVA group s optical oxygen sensors have short response time and maintains stable, even in dynamically changing conditions. The measurement principle is to send a blue modulated light through a foil and measure the reflected red light. The signal is then linearised and temperature compensated. This principle makes this sensor working in stationary water, no currents are necessary for correct oxygen measurements. Optical sensors react quickly to changes and stay stable even in dynamically changing conditions. The RDO Oxygen sensor stores all logged measurement information in the replaceable cap tip for one year at a time. The tip holds a calibrated cap covering the sensor. This is fresh produce, and has an expiration date. After this expiration date (up to 12 months after installation), a new user code must be ordered and installed. Note the date for when the sensor is installed, and make sure to order a new code before the old one expires. AKVA part no. for the code: 10000855 Page 13 of 29

3.3 Temperature sensor Resolution +/- 0,1 C Accuracy +/- 0,5 C Measurement range 0-50 C Housing materials Cable Depth rating Machined bronze 30m (100 ), urethane cable 30m (100 ), limited by cable Size - L x Ø 80mm x 50mm (3.15 x 2 ) Weight Connection plug 3,5kg (7.7lbs) with cable Amphenol waterproof plug (potted with epoxy) Page 14 of 29

The Akvasmart temperature sensor is the foundation for all feeding regimes and growth tables. It is a robust and reliable sensor made to measure temperatures at different depths. The real time measurements are continuously shown on the surveillance computer screen and are logged in Akvacontrol. With temperature measurements and integrated feed and growth tables, Akvacontrol calculate expected daily feed. This is a good estimate for setting up the feeding. Sensor may be connected to the wireless system via CSU to an environment station (EAP) or directly to the selector in the feeding system. Akvasmart temperature sensors are produced in bronze, which prevents sprout and gives minimal maintenance, and also gives quick response to temperature changes. Page 15 of 29

4 Flow diagram for sensors The temperature sensor can also be connected directly to a CCS Feeding system. Page 16 of 29

5 Installation and suspension 5.1 Current sensor Before the current sensor is placed in the water, the weight needs to be attached about 100cm from the cable coupling. Use the Unbraco keys and make sure that it is properly attached. 5.2 Oxygen sensor Before installing the oxygen sensor, write down the date of installation, so that new code for the cap is ready for use when the old one expires. 5.3 All sensors All sensor cables have to be attached to ropes before launched in the water to avoid stretch and tension to the cable when raising them out from the water. Fasten the lifting ropes to the cable as close to the sensor as possible, using a rolling hitch. Mark the lifting ropes with knots, pieces of tape or other water proof markers for every or every other meter to manually indicate the sensors depths. This can also be marked on the cable, however NOT with knots! When all these preparations are executed, launch the sensors in desired depth in- or outside of the cages or by the barge. Page 17 of 29

6 Power supply The sensors are connected to either CSU or EAP for transfer of power and signals. The sensor cables have their own plug caps attached to the cable ends. Make sure that these connections never break, in order to have full control of the caps whereabouts. If the connections should be loosened from the cable and the cable-input in CSU and EAP has to be taken care of by the site personnel, so that they can be replaced when the sensors are taken away from the cage area. We recommend collecting all loose plug caps together in a safe place in the barge. Page 18 of 29

7 Handling the cable When the sensor cables are coiled, it is important not to twirl them. These cables do not tolerate any twirling. Do not coil a sensor cable up like a rope, but follow these instructions: 1 Make a loop and fasten the loop with strips or something similar 2 Roll the coil around this loop 3 If twines appear, the entire coil must be rotated. This way you avoid twirling to the cable, and this also leads to prolonged operating time for the cable 4 If you end up with excessive cable after launching the sensor in the water, fasten the coil with tape or strips and hang it to the cage edge and out of the walking path around the cage. Make sure that the attaching lifting ropes are long enough to avoid stretching the cables when suspending them. Page 19 of 29

8 Maintenance The sensors are maintenance free, but we recommend checking and wiping them off regularly in order to achieve correct measurements. When the temperatures are high and in brighter seasons, cleaning off sprout will be necessary more often. Clean the sensor with a moist cloth or a soft brush, to avoid scrapes in the sensors materials. We recommend taking the sensors out of the water once a month to check both the sensor and the cable thoroughly for external damages. 8.1 Daily inspection - control the ropes and suspensions that are attached to the sensor for tearings and wearings - control that the cable hangs free and is not exposed to gnawing - check all equipment and suspensions during and after periods of bad weather Add these daily routines into a daily maintenance form along with other daily maintenance routines. 8.2 Weekly inspection and maintenance - weekly cleaning of the sensors during bright and warm seasons (sprout-season) - shells, barnacle and similar has to be removed in order to maintain correct measurements - control suspensions and lifting ropes - oxygen sensor: clean the sensor measurement window very gently with a soft, moist cloth or a soft brush Page 20 of 29

8.3 Monthly inspection and maintenance - Control and check all suspensions and ropes thoroughly - Control cable thoroughly. If any wear and tear is discovered, find the cause for this and hang the cable in a way that avoids further tearings. If there is any risk of breakage, contact AKVA for a cable change - Control the sensors cable strain relief - In case of corrosion detection, contact AKVA immediately! 8.4 Recommended maintenance plan Parameter Daily Weekly Monthly Comments Check ropes for tearings Check that the cable hangs freely X X Clean sensor Remove shells, barnacle etc. Check lifting ropes thoroughly X X X Place ropes somewhere else if gnawing occurs, change rope if necessary Control the power cable X Place cable somewhere else if gnawing occurs. Change power cable if necessary Control lifting rope Control sensors for corrosion X X Contact AKVA in case of corrosion Page 21 of 29

8.5 Maintenance plans 8.5.1 Instructions ALWAYS make copies of the maintenance forms! Use one form per sensor. Fill in: - week number in the daily maintenance forms - name of the month in the weekly forms - correct year in the monthly maintenance forms This is important in order to maintain regularly maintenance. After each task is performed, sign with your initials in the correct box. Make copies of the next two pages and keep these copies in a maintenance binder. It may be smart to mark the last copy with a note that says This is the last copy, make more before using this in order to always have access to at least one copy. Page 22 of 29

8.5.2 Daily maintenance for sensor (fill in correct type) Make copies of this form before filling anything in. Use one form per sensor. Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Week Mon Tue Wed Thu Fri Sat Sun Check ropes for tearings Check that the cable hangs freely Page 23 of 29

8.5.3 Weekly maintenance for sensor (fill in correct type) Make copies of this form before filling anything in. Use one form per sensor. Month Week Week Week Week Clean sensor, remove sprout, shells and similar Check lifting ropes thoroughly Month Week Week Week Week Clean sensor, remove sprout, shells and similar Check lifting ropes thoroughly Month Week Week Week Week Clean sensor, remove sprout, shells and similar Check lifting ropes thoroughly Month Week Week Week Week Clean sensor, remove sprout, shells and similar Check lifting ropes thoroughly Month Week Week Week Week Clean sensor, remove sprout, shells and similar Check lifting ropes thoroughly Page 24 of 29

8.5.4 Monthly maintenance for sensor (fill in correct type) Make copies of this form before filling anything in. Use one form per sensor. Year Jan Feb Mar Apr May Jun Check power cable thoroughly Change lifting ropes if necessary Control sensor for corrosion Year July Aug Sept Oct Nov Dec Check power cable thoroughly Change lifting ropes if necessary Control sensor for corrosion Year Jan Feb Mar Apr May Jun Check power cable thoroughly Change lifting ropes if necessary Control sensor for corrosion Year July Aug Sept Oct Nov Dec Check power cable thoroughly Change lifting ropes if necessary Control sensor for corrosion Page 25 of 29

Appendix A - Index A accuracy 9, 11, 13 B bad weather 5, 19 C cable 5, 8, 9, 11, 13, 16-20 coil 5, 18 corrosion 5, 20 CSU 5, 8, 14, 15, 17 current 8, 9, 10, 12, 16 D damage 4, 5, 19 depth 9, 11, 13, 14, 16 disinfecting 5 E EAP 5, 8, 14, 15, 17 environmental 6, 8, 14 F feed factor 8 feeding system 14 I information 4, 6, 7, 12 injuries 4 L lifting rope 16, 18, 19 logged 8, 12, 14 M maintenance 5-7, 10, 12, 14, 19-24 materials 9, 11, 13, 19 O oxygen 8, 12 P plug caps 5, 17 power 4, 5, 9, 11, 17 R repairs 5, 7 rope 4, 5, 7, 16, 18-20 S sensor data 8 service note 4 signal 8, 10, 17 size 9, 11, 13 sprout 5, 14, 19 suspension 5, 16, 19, 20 T tables 8, 14 temperature 8, 12, 14, 19 twirl 5, 18 W warranty 4 weight 9, 11, 13, 16 Page 26 of 29

of 29 Appendix B - Deviation form Make copies of this form before filling anything in. Use one form per sensor. Deviation control nr.: Unit: Producer: Prod.no.: Purchase year: Deviation description: Follow up proposition: Date and signature, declarer: Follow up directed: Status: New action for deviation no.: Date and signature, follow up: Page 27 of 29

of 29 Appendix C - Notes Page 28 of 29

of 29 Page 29 of 29